메뉴 건너뛰기




Volumn 95, Issue 1, 2010, Pages 218-224

Bone properties surrounding hydroxyapatite-coated custom osseous integrated dental implants

Author keywords

bone; dental implants; hydroxyapatite; nanoindentation

Indexed keywords

AVERAGE VALUES; BACKSCATTERED ELECTRON IMAGING; BIOMECHANICAL PROPERTIES; BONE-IMPLANT INTERFACES; COATED IMPLANTS; DENTAL IMPLANTS; GRAY LEVELS; HISTOMORPHOMETRIC ANALYSIS; IMPLANT INTERFACES; IN-VIVO; LONG TERM; MINERAL CONTENT;

EID: 78449266294     PISSN: 15524973     EISSN: 15524981     Source Type: Journal    
DOI: 10.1002/jbm.b.31693     Document Type: Article
Times cited : (37)

References (36)
  • 2
    • 0034801327 scopus 로고    scopus 로고
    • Material fundamentals and clinical performance of plasma-sprayed hydroxyapatite coatings: A review
    • Sun L, Berndt CC, Gross KA, Kucuk A,. Material fundamentals and clinical performance of plasma-sprayed hydroxyapatite coatings: A review. J Biomed Mater Res 2001; 58: 570-592.
    • (2001) J Biomed Mater Res , vol.58 , pp. 570-592
    • Sun, L.1    Berndt, C.C.2    Gross, K.A.3    Kucuk, A.4
  • 4
    • 7644236296 scopus 로고    scopus 로고
    • Dentin adhesion and microleakage of a resin-based calcium phosphate pulp capping and basing cement
    • Dickens SH, Kelly SR, Flaim GM, Giuseppetti AA,. Dentin adhesion and microleakage of a resin-based calcium phosphate pulp capping and basing cement. Eur J Oral Sci 2004; 112: 452-457.
    • (2004) Eur J Oral Sci , vol.112 , pp. 452-457
    • Dickens, S.H.1    Kelly, S.R.2    Flaim, G.M.3    Giuseppetti, A.A.4
  • 6
    • 0344740571 scopus 로고    scopus 로고
    • Bone cements and fillers: A review
    • Kenny SM, Buggy M,. Bone cements and fillers: A review. J Mater Sci Mater Med 2003; 14: 923-938.
    • (2003) J Mater Sci Mater Med , vol.14 , pp. 923-938
    • Kenny, S.M.1    Buggy, M.2
  • 10
    • 0026456047 scopus 로고
    • The advantages of coated titanium implants prepared by radiofrequency sputtering from hydroxyapatite
    • Cooley DR, Van Dellen AF, Burgess JO, Windeler AS,. The advantages of coated titanium implants prepared by radiofrequency sputtering from hydroxyapatite. J Prosthet Dent 1992; 67: 93-100.
    • (1992) J Prosthet Dent , vol.67 , pp. 93-100
    • Cooley, D.R.1    Van Dellen, A.F.2    Burgess, J.O.3    Windeler, A.S.4
  • 11
    • 0023982042 scopus 로고
    • Calcium phosphate-coated porous titanium implants for enhanced skeletal fixation
    • Rivero DP, Fox J, Skipor AK, Urban RM, Galante JO,. Calcium phosphate-coated porous titanium implants for enhanced skeletal fixation. J Biomed Mater Res 1988; 22: 191-201.
    • (1988) J Biomed Mater Res , vol.22 , pp. 191-201
    • Rivero, D.P.1    Fox, J.2    Skipor, A.K.3    Urban, R.M.4    Galante, J.O.5
  • 13
    • 0034998825 scopus 로고    scopus 로고
    • Hydroxyapatite-coated acetabular components. Histological and histomorphometric analysis of six cups retrieved at autopsy between three and seven years after successful implantation
    • Tonino A, Oosterbos C, Rahmy A, Therin M, Doyle C,. Hydroxyapatite-coated acetabular components. Histological and histomorphometric analysis of six cups retrieved at autopsy between three and seven years after successful implantation. J Bone Joint Surg Am A 2001; 83: 817-825.
    • (2001) J Bone Joint Surg Am A , vol.83 , pp. 817-825
    • Tonino, A.1    Oosterbos, C.2    Rahmy, A.3    Therin, M.4    Doyle, C.5
  • 14
    • 59649116722 scopus 로고    scopus 로고
    • Bone remodeling and hydroxyapatite resorption in coated primary hip prostheses
    • Tonino AJ, van der Wal BC, Heyligers IC, Grimm B,. Bone remodeling and hydroxyapatite resorption in coated primary hip prostheses. Clin Orthop Relat Res 2009; 467: 478-484.
    • (2009) Clin Orthop Relat Res , vol.467 , pp. 478-484
    • Tonino, A.J.1    Van Der Wal, B.C.2    Heyligers, I.C.3    Grimm, B.4
  • 15
    • 0034584540 scopus 로고    scopus 로고
    • A methodological study for the analysis of apatite-coated dental implants retrieved from humans
    • MacDonald DE, Betts F, Doty SB, Boskey AL,. A methodological study for the analysis of apatite-coated dental implants retrieved from humans. Ann Periodontol 2000; 5: 175-184.
    • (2000) Ann Periodontol , vol.5 , pp. 175-184
    • MacDonald, D.E.1    Betts, F.2    Doty, S.B.3    Boskey, A.L.4
  • 16
    • 35649020744 scopus 로고    scopus 로고
    • Anorganic bone matrix retrieved 14 years after a sinus augmentation procedure: A histologic and histomorphometric evaluation
    • Iezzi G, Degidi M, Scarano A, Petrone G, Piattelli A,. Anorganic bone matrix retrieved 14 years after a sinus augmentation procedure: A histologic and histomorphometric evaluation. J Periodontol 2007; 78: 2057-2061.
    • (2007) J Periodontol , vol.78 , pp. 2057-2061
    • Iezzi, G.1    Degidi, M.2    Scarano, A.3    Petrone, G.4    Piattelli, A.5
  • 18
    • 0030631536 scopus 로고    scopus 로고
    • Resorption of hydroxyapatite and fluorapatite ceramic coatings on weight-bearing implants: A quantitative and morphological study in dogs
    • Overgaard S, Lind M, Josephsen K, Maunsbach AB, Bunger C, Soballe K,. Resorption of hydroxyapatite and fluorapatite ceramic coatings on weight-bearing implants: a quantitative and morphological study in dogs. J Biomed Mater Res 1998; 39: 141-152.
    • (1998) J Biomed Mater Res , vol.39 , pp. 141-152
    • Overgaard, S.1    Lind, M.2    Josephsen, K.3    Maunsbach, A.B.4    Bunger, C.5    Soballe, K.6
  • 19
    • 70349730646 scopus 로고    scopus 로고
    • Histologic and histomorphometric evaluation of the bone response around a hydroxyapatite-coated implant retrieved after 15 years
    • Iezzi G, Orlandi S, Pecora G, Piattelli A,. Histologic and histomorphometric evaluation of the bone response around a hydroxyapatite-coated implant retrieved after 15 years. Int J Periodontics Restorative Dent 2009; 29: 99-105.
    • (2009) Int J Periodontics Restorative Dent , vol.29 , pp. 99-105
    • Iezzi, G.1    Orlandi, S.2    Pecora, G.3    Piattelli, A.4
  • 20
    • 0028401595 scopus 로고
    • Bone response to hydroxyapatite-coated and commercially pure titanium implants in the human arthritic knee
    • Carlsson L, Regner L, Johansson C, Gottlander M, Herberts P,. Bone response to hydroxyapatite-coated and commercially pure titanium implants in the human arthritic knee. J Orthop Res 1994; 12: 274-285.
    • (1994) J Orthop Res , vol.12 , pp. 274-285
    • Carlsson, L.1    Regner, L.2    Johansson, C.3    Gottlander, M.4    Herberts, P.5
  • 21
    • 0031260276 scopus 로고    scopus 로고
    • Elastic properties of human cortical and trabecular lamellar bone measured by nanoindentation
    • Rho JY, Tsui TY, Pharr GM,. Elastic properties of human cortical and trabecular lamellar bone measured by nanoindentation. Biomaterials 1997; 18: 1325-1330.
    • (1997) Biomaterials , vol.18 , pp. 1325-1330
    • Rho, J.Y.1    Tsui, T.Y.2    Pharr, G.M.3
  • 22
    • 30344467213 scopus 로고    scopus 로고
    • An application of nanoindentation technique to measure bone tissue Lamellae properties
    • Hoffler CE, Guo XE, Zysset PK, Goldstein SA,. An application of nanoindentation technique to measure bone tissue Lamellae properties. J Biomech Eng 2005; 127: 1046-1053.
    • (2005) J Biomech Eng , vol.127 , pp. 1046-1053
    • Hoffler, C.E.1    Guo, X.E.2    Zysset, P.K.3    Goldstein, S.A.4
  • 23
    • 0033213750 scopus 로고    scopus 로고
    • Elastic modulus and hardness of cortical and trabecular bone lamellae measured by nanoindentation in the human femur
    • Zysset PK, Guo XE, Hoffler CE, Moore KE, Goldstein SA,. Elastic modulus and hardness of cortical and trabecular bone lamellae measured by nanoindentation in the human femur. J Biomech 1999; 32: 1005-1012.
    • (1999) J Biomech , vol.32 , pp. 1005-1012
    • Zysset, P.K.1    Guo, X.E.2    Hoffler, C.E.3    Moore, K.E.4    Goldstein, S.A.5
  • 24
    • 0031969826 scopus 로고    scopus 로고
    • Microhardness and anisotropy of the vital osseous interface and endosseous implant supporting bone
    • Huja SS, Katona TR, Moore BK, Roberts WE,. Microhardness and anisotropy of the vital osseous interface and endosseous implant supporting bone. J Orthop Res 1998; 16: 54-60.
    • (1998) J Orthop Res , vol.16 , pp. 54-60
    • Huja, S.S.1    Katona, T.R.2    Moore, B.K.3    Roberts, W.E.4
  • 25
    • 34249945828 scopus 로고    scopus 로고
    • Examination of local variations in viscous, elastic, and plastic indentation responses in healing bone
    • Oyen ML, Ko CC,. Examination of local variations in viscous, elastic, and plastic indentation responses in healing bone. J Mater Sci Mater Med 2007; 18: 623-628.
    • (2007) J Mater Sci Mater Med , vol.18 , pp. 623-628
    • Oyen, M.L.1    Ko, C.C.2
  • 26
    • 33847177316 scopus 로고    scopus 로고
    • Nanoscale characterization of bone-implant interface and biomechanical modulation of bone ingrowth
    • Clark PA, Clark AM, Rodriguez A, Hussain MA, Mao JJ,. Nanoscale characterization of bone-implant interface and biomechanical modulation of bone ingrowth. Mater Sci Eng C 2007; 27: 382-393.
    • (2007) Mater Sci Eng C , vol.27 , pp. 382-393
    • Clark, P.A.1    Clark, A.M.2    Rodriguez, A.3    Hussain, M.A.4    Mao, J.J.5
  • 28
    • 78449307447 scopus 로고    scopus 로고
    • Personal communication
    • Martin DM,. Personal communication, 2008.
    • (2008)
    • Martin, D.M.1
  • 29
    • 0026875935 scopus 로고
    • An improved technique for determining hardness and elastic modulus using load and displacement sensing indentation experiments
    • Oliver WC, Pharr GM,. An improved technique for determining hardness and elastic modulus using load and displacement sensing indentation experiments. J Mater Res 1992; 7: 1564-1583.
    • (1992) J Mater Res , vol.7 , pp. 1564-1583
    • Oliver, W.C.1    Pharr, G.M.2
  • 30
    • 0033140443 scopus 로고    scopus 로고
    • In vivo bone response to biomechanical loading at the bone/dental-implant interface
    • Brunski JB,. In vivo bone response to biomechanical loading at the bone/dental-implant interface. Adv Dent Res 1999; 13: 99-119.
    • (1999) Adv Dent Res , vol.13 , pp. 99-119
    • Brunski, J.B.1
  • 31
    • 0028066776 scopus 로고
    • Mechanical loading thresholds for lamellar and woven bone formation
    • Turner CH, Forwood MR, Rho JY, Yoshikawa T,. Mechanical loading thresholds for lamellar and woven bone formation. J Bone Miner Res 1994; 9: 87-97.
    • (1994) J Bone Miner Res , vol.9 , pp. 87-97
    • Turner, C.H.1    Forwood, M.R.2    Rho, J.Y.3    Yoshikawa, T.4
  • 32
    • 0031604726 scopus 로고    scopus 로고
    • Tripodal mandibular subperiosteal implant: Basic sciences, operational procedures, and clinical data
    • Linkow LI, Wagner JR, Chanavaz M,. Tripodal mandibular subperiosteal implant: Basic sciences, operational procedures, and clinical data. J Oral Implantol 1998; 24: 16-36.
    • (1998) J Oral Implantol , vol.24 , pp. 16-36
    • Linkow, L.I.1    Wagner, J.R.2    Chanavaz, M.3
  • 33
    • 4143049300 scopus 로고    scopus 로고
    • A descriptive 18-year retrospective review of subperiosteal implants for patients with severely atrophied edentulous mandibles
    • Moore DJ, Hansen PA,. A descriptive 18-year retrospective review of subperiosteal implants for patients with severely atrophied edentulous mandibles. J Prosthet Dent 2004; 92: 145-150.
    • (2004) J Prosthet Dent , vol.92 , pp. 145-150
    • Moore, D.J.1    Hansen, P.A.2
  • 34
    • 0042570752 scopus 로고    scopus 로고
    • Analysis of HA-coated subperiosteal implants
    • discussion 117-119
    • Minichetti JC,. Analysis of HA-coated subperiosteal implants. J Oral Implantol 2003; 29: 111-116; discussion 117-119.
    • (2003) J Oral Implantol , vol.29 , pp. 111-116
    • Minichetti, J.C.1
  • 35
    • 0030096985 scopus 로고    scopus 로고
    • The mandibular subperiosteal implant denture: A prospective survival study
    • Amet EM,. The mandibular subperiosteal implant denture: A prospective survival study. J Prosthet Dent 1996; 75: 347-348.
    • (1996) J Prosthet Dent , vol.75 , pp. 347-348
    • Amet, E.M.1
  • 36
    • 0026352034 scopus 로고
    • Hydroxyapatite-coated femoral stems. Histological analysis of components retrieved at autopsy
    • Bauer TW, Geesink RC, Zimmerman R, McMahon JT,. Hydroxyapatite-coated femoral stems. Histological analysis of components retrieved at autopsy. J Bone Joint Surg Am 1991; 73: 1439-1452.
    • (1991) J Bone Joint Surg Am , vol.73 , pp. 1439-1452
    • Bauer, T.W.1    Geesink, R.C.2    Zimmerman, R.3    McMahon, J.T.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.