메뉴 건너뛰기




Volumn 96, Issue 22, 2010, Pages 1849-1856

Transcatheter valve implantation for patients with aortic stenosis

Author keywords

[No Author keywords available]

Indexed keywords

ANGIOCARDIOGRAPHY; AORTA VALVE PROSTHESIS; AORTA VALVE REPLACEMENT; AORTA VALVE STENOSIS; EDWARDS SAPIEN VALVE PROSTHESIS; HEART CATHETERIZATION; HIGH RISK PATIENT; HUMAN; MORTALITY; MULTIDETECTOR COMPUTED TOMOGRAPHY; PATIENT SELECTION; PRIORITY JOURNAL; REVIEW; SURGICAL TECHNIQUE; TRANSCATHETER AORTIC VALVE IMPLANTATION; TRANSESOPHAGEAL ECHOCARDIOGRAPHY; TRANSTHORACIC ECHOCARDIOGRAPHY; TREATMENT CONTRAINDICATION; TREATMENT OUTCOME;

EID: 78349296392     PISSN: 13556037     EISSN: 1468201X     Source Type: Journal    
DOI: 10.1136/hrt.2009.183319     Document Type: Review
Times cited : (10)

References (20)
  • 1
    • 33847134400 scopus 로고    scopus 로고
    • Guidelines on the management of valvular heart disease: The Task Force on the Management of Valvular Heart Disease of the European Society of Cardiology
    • Task Force on the Management of Valvular Hearth Disease of the European Society of Cardiology; ESC Committee for Practice Guidelines
    • Vahanian A, Baumgartner H, Bax J, et al. Task Force on the Management of Valvular Hearth Disease of the European Society of Cardiology; ESC Committee for Practice Guidelines. Guidelines on the management of valvular heart disease: The Task Force on the Management of Valvular Heart Disease of the European Society of Cardiology. Eur Heart J 2007;28:230-68.
    • (2007) Eur Heart J , vol.28 , pp. 230-268
    • Vahanian, A.1    Baumgartner, H.2    Bax, J.3
  • 2
    • 58249086539 scopus 로고    scopus 로고
    • Isolated aortic valve replacement in North America comprising 108,687 patients in 10 years: Changes in risks, valve types, and outcomes in the Society of Thoracic surgeons national database
    • Brown JM, O'Brian SM, Wu C, et al. Isolated aortic valve replacement in North America comprising 108,687 patients in 10 years: changes in risks, valve types, and outcomes in the Society of Thoracic surgeons national database. J Thorac Cardiovasc Surg 2009;137:82-90.
    • (2009) J Thorac Cardiovasc Surg , vol.137 , pp. 82-90
    • Brown, J.M.1    O'Brian, S.M.2    Wu, C.3
  • 3
    • 28544435658 scopus 로고    scopus 로고
    • Decision-making in elderly patients with severe aortic stenosis: Why are so many denied surgery?
    • Iung B, Cachier A, Baron G, et al. Decision-making in elderly patients with severe aortic stenosis: why are so many denied surgery? Eur Heart J 2005;26:2714-20.
    • (2005) Eur Heart J , vol.26 , pp. 2714-2720
    • Iung, B.1    Cachier, A.2    Baron, G.3
  • 4
    • 0037058854 scopus 로고    scopus 로고
    • Percutaneous transcatheter implantation of an aortic valve prosthesis for calcific aortic stenosis: First human case description
    • Cribier A, Eltchaninoff H, Bash A, et al. Percutaneous transcatheter implantation of an aortic valve prosthesis for calcific aortic stenosis: first human case description. Circulation 2002;106:3006-8. Description of the first transcatheter aortic valve implantation procedure in a human.
    • (2002) Circulation , vol.106 , pp. 3006-3008
    • Cribier, A.1    Eltchaninoff, H.2    Bash, A.3
  • 5
    • 44949107279 scopus 로고    scopus 로고
    • Transcatheter valve implantation for patients with aortic stenosis: A position statement from the European Association of Cardio-Thoracic Surgery (EACTS) and the European Society of Cardiology (ESC) in collaboration with the European Association of Percutaneous Cardiovascular Interventions (EAPCI)
    • Vahanian A, Alfieri OR, Al-Attar N, et al. Transcatheter valve implantation for patients with aortic stenosis: a position statement from the European Association of Cardio-Thoracic Surgery (EACTS) and the European Society of Cardiology (ESC) in collaboration with the European Association of Percutaneous Cardiovascular Interventions (EAPCI). Eur Heart J 2008;29:1463-70. Document issued by both medical and surgical scientific societies to set the stage for the use of transcatheter aortic valve implantation.
    • (2008) Eur Heart J , vol.29 , pp. 1463-1470
    • Vahanian, A.1    Alfieri, O.R.2    Al-Attar, N.3
  • 6
    • 37549026426 scopus 로고    scopus 로고
    • Reliability of risk algorithms in predicting early and late operative outcomes in high-risk patients undergoing aortic valve replacement
    • Dewey TM, Brown D, Ryan WH, et al. Reliability of risk algorithms in predicting early and late operative outcomes in high-risk patients undergoing aortic valve replacement. J Thorac Cardiovasc Surg 2008;135:180-7. Comparative evaluation of the predictive value of the risk scores for aortic valve replacement.
    • (2008) J Thorac Cardiovasc Surg , vol.135 , pp. 180-187
    • Dewey, T.M.1    Brown, D.2    Ryan, W.H.3
  • 7
    • 32644444587 scopus 로고    scopus 로고
    • Development and validation of a prognostic index for 4-year mortality in older adults
    • Erratum in: JAMA 2006;295:1900
    • Lee SJ, Lindquist K, Segal MR, et al. Development and validation of a prognostic index for 4-year mortality in older adults. JAMA 2006;295:801-8. Erratum in: JAMA 2006;295:1900. Semi-quantitative score for evaluation of life expectancy.
    • (2006) JAMA , vol.295 , pp. 801-808
    • Lee, S.J.1    Lindquist, K.2    Segal, M.R.3
  • 9
    • 43649086862 scopus 로고    scopus 로고
    • Non-invasive evaluation of the aortic root with multislice computed tomography: Implications for transcatheter aortic valve replacement
    • Tops L, Wood D, Delgado V, et al. Non-invasive evaluation of the aortic root with multislice computed tomography: implications for transcatheter aortic valve replacement. J Am Coll Cardiol Img 2008;1:321-30. Pioneering work on the role of MSCT during transcatheter aortic valve implantation.
    • (2008) J Am Coll Cardiol Img , vol.1 , pp. 321-330
    • Tops, L.1    Wood, D.2    Delgado, V.3
  • 10
    • 75749129479 scopus 로고    scopus 로고
    • Comparison of aortic root dimensions and geometries before and after transcatheter aortic valve implantation by 2- and 3-dimensional transesophageal echocardiography and multi-slice computed tomography
    • Ng ACT, Delgado V, van de Kley F, et al. Comparison of aortic root dimensions and geometries before and after transcatheter aortic valve implantation by 2- and 3-dimensional transesophageal echocardiography and multi-slice computed tomography. Circ Cardiovasc Imaging 2010;3:94-102.
    • (2010) Circ Cardiovasc Imaging , vol.3 , pp. 94-102
    • Ng, A.C.T.1    Delgado, V.2    Van De Kley, F.3
  • 11
    • 57749202934 scopus 로고    scopus 로고
    • Transapical aortic valve implantation: Step by step
    • Walther T, Dewey T, Borger MA, et al. Transapical aortic valve implantation: step by step. Ann Thorac Surg 2009;87:276-83.
    • (2009) Ann Thorac Surg , vol.87 , pp. 276-283
    • Walther, T.1    Dewey, T.2    Borger, M.A.3
  • 12
    • 67649532220 scopus 로고    scopus 로고
    • Transcatheter aortic valve implantation: Impact on clinical and valve-related outcomes
    • Webb JG, Altwegg L, Boone RH, et al. Transcatheter aortic valve implantation: impact on clinical and valve-related outcomes. Circulation 2009;119:3009-16. The largest single centre series using the balloon expandable prosthesis.
    • (2009) Circulation , vol.119 , pp. 3009-3016
    • Webb, J.G.1    Altwegg, L.2    Boone, R.H.3
  • 13
    • 60849121992 scopus 로고    scopus 로고
    • Progress and current status of percutaneous aortic valve replacement: Results of three device generations of the CoreValve revalving system
    • Grube E, Buellesfeld L, Mueller R, et al. Progress and current status of percutaneous aortic valve replacement: results of three device generations of the CoreValve revalving system. Circ Cardiovasc Interv 2008;1:167-75. The largest single centre study using the self expandable device.
    • (2008) Circ Cardiovasc Interv , vol.1 , pp. 167-175
    • Grube, E.1    Buellesfeld, L.2    Mueller, R.3
  • 14
    • 67650088413 scopus 로고    scopus 로고
    • Results of transfemoral or transapical aortic valve implantation following a uniform assessment in high-risk patients with aortic stenosis
    • Himbert D, Descoutures F, Al-Attar N, et al. Results of transfemoral or transapical aortic valve implantation following a uniform assessment in high-risk patients with aortic stenosis. J Am Coll Cardiol 2009;54:303-11.
    • (2009) J Am Coll Cardiol , vol.54 , pp. 303-311
    • Himbert, D.1    Descoutures, F.2    Al-Attar, N.3
  • 15
    • 55849132881 scopus 로고    scopus 로고
    • Procedural and 30-day outcomes following transcatheter aortic valve implantation using the third generation (18 Fr) CoreValve ReValving System: Results from the multicentre, expanded evaluation registry 1-year following CE mark approval
    • on behalf of the clinical centres who actively participated in the registry
    • Piazza N, Grube E, Gerckens U, et al; on behalf of the clinical centres who actively participated in the registry. Procedural and 30-day outcomes following transcatheter aortic valve implantation using the third generation (18 Fr) CoreValve ReValving System: results from the multicentre, expanded evaluation registry 1-year following CE mark approval. EuroIntervention 2008;4:242-9.
    • (2008) EuroIntervention , vol.4 , pp. 242-249
    • Piazza, N.1    Grube, E.2    Gerckens, U.3
  • 16
    • 34748910153 scopus 로고    scopus 로고
    • Transapical minimally invasive aortic valve implantation: Multicenter experience
    • Walther T, Simon P, Dewey T, et al. Transapical minimally invasive aortic valve implantation: multicenter experience. Circulation 2007;116(11 Suppl):I240-5. The largest report on the transapical approach.
    • (2007) Circulation , vol.116 , Issue.11 SUPPL.
    • Walther, T.1    Simon, P.2    Dewey, T.3
  • 17
    • 47049087117 scopus 로고    scopus 로고
    • United States feasibility study of transcatheter insertion of a stented aortic valve by the left ventricular apex
    • Svensson L, Dewey T, Kapadia S, et al. United States feasibility study of transcatheter insertion of a stented aortic valve by the left ventricular apex. Ann Thorac Surg 2008;86:46-55. Largest North American registry on the transapical approach.
    • (2008) Ann Thorac Surg , vol.86 , pp. 46-55
    • Svensson, L.1    Dewey, T.2    Kapadia, S.3
  • 18
    • 65149088915 scopus 로고    scopus 로고
    • Comparison of the hemodynamic performance of purcutaneous and surgical bioprotheses for the treatment of severe aortic stenosis
    • Clavel MA, Webb JG, Pibarot P, et al. Comparison of the hemodynamic performance of purcutaneous and surgical bioprotheses for the treatment of severe aortic stenosis. J Am Coll Cardiol 2009;53:1883-91.
    • (2009) J Am Coll Cardiol , vol.53 , pp. 1883-1891
    • Clavel, M.A.1    Webb, J.G.2    Pibarot, P.3
  • 20
    • 67651097904 scopus 로고    scopus 로고
    • Quality of life assessment after percutaneous aortic valve implantation
    • Ussia GP, Mulè M, Barbanti M, et al. Quality of life assessment after percutaneous aortic valve implantation. Eur Heart J 2009;30:1790-6.
    • (2009) Eur Heart J , vol.30 , pp. 1790-1796
    • Ussia, G.P.1    Mulè, M.2    Barbanti, M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.