메뉴 건너뛰기




Volumn 18, Issue 7, 2010, Pages 26-36

Care after chemical, biological, radiation or nuclear events

Author keywords

Airway management; Biological; Chemical; Radiation or nuclear incidents

Indexed keywords

CHEMICAL WARFARE AGENT;

EID: 78349296091     PISSN: 13545752     EISSN: None     Source Type: Journal    
DOI: 10.7748/en2010.11.18.7.26.c8086     Document Type: Article
Times cited : (4)

References (93)
  • 1
    • 0024789102 scopus 로고
    • Assessing the position of the tracheal tube: The reliability of different methods
    • Anderson K, Hald A (1989) Assessing the position of the tracheal tube: the reliability of different methods. Anaesthesia. 44, 12, 984-985.
    • (1989) Anaesthesia , vol.44 , Issue.12 , pp. 984-985
    • Anderson, K.1    Hald, A.2
  • 2
    • 0036843037 scopus 로고    scopus 로고
    • Efficacy of the laryngeal tube by inexperienced personnel
    • DOI 10.1016/S0300-9572(02)00170-3, PII S0300957202001703
    • Asai T, Hidaka I, Kawachi S (2002a) Efficacy of the laryngeal tube by inexperienced personnel. Resuscitation. 55, 2, 171-175. (Pubitemid 35284451)
    • (2002) Resuscitation , vol.55 , Issue.2 , pp. 171-175
    • Asai, T.1    Hidaka, I.2    Kawachi, S.3
  • 3
    • 0036841940 scopus 로고    scopus 로고
    • The laryngeal tube compared with the laryngeal mask: Insertion, gas leak pressure and gastric inflation
    • Asai T, Kawashima A, Hidaka I, Kawach S (2002b) The laryngeal tube compared with the laryngeal mask: insertion, gas leak pressure and gastric inflation. British Journal of Anaesthesia. 89, 5, 729-732.
    • (2002) British Journal of Anaesthesia , vol.89 , Issue.5 , pp. 729-732
    • Asai, T.1    Kawashima, A.2    Hidaka, I.3    Kawach, S.4
  • 4
    • 0033719585 scopus 로고    scopus 로고
    • Efficacy of the laryngeal tube during intermittent positive-pressure ventilation
    • Asai T, Murao K, Shingu K (2000c) Efficacy of the laryngeal tube during intermittent positive-pressure ventilation. Anaesthesia. 55, 11, 1099-1102.
    • (2000) Anaesthesia , vol.55 , Issue.11 , pp. 1099-1102
    • Asai, T.1    Murao, K.2    Shingu, K.3
  • 5
    • 0027249525 scopus 로고
    • Ability of paramedics to use the Combitube in prehospital cardiac arrest
    • Atherton GL, Johnson JC (1993) Ability of paramedics to use the Combitube in prehospital cardiac arrest. Annals of Emergency Medicine. 22, 8, 27-32.
    • (1993) Annals of Emergency Medicine , vol.22 , Issue.8 , pp. 27-32
    • Atherton, G.L.1    Johnson, J.C.2
  • 7
    • 57149102921 scopus 로고    scopus 로고
    • Cuffed oropharyngeal airway (COPA ) placement is delayed by wearing antichemical protective gear
    • Ben-Abraham R, Flaishon R, Sotman A et al (2008) Cuffed oropharyngeal airway (COPA ) placement is delayed by wearing antichemical protective gear. Emergency Medical Journal. 25, 847-850.
    • (2008) Emergency Medical Journal , vol.25 , pp. 847-850
    • Ben-Abraham, R.1    Flaishon, R.2    Sotman, A.3
  • 8
    • 38549181011 scopus 로고    scopus 로고
    • A comparison of seal in seven supraglottic airway devices using a cadaver model of elevated esophageal pressure
    • Bercker S, Schmidbauer W, Volk T et al (2008) A comparison of seal in seven supraglottic airway devices using a cadaver model of elevated esophageal pressure. Anesthesia and Analgesia. 106, 2, 445-448.
    • (2008) Anesthesia and Analgesia , vol.106 , Issue.2 , pp. 445-448
    • Bercker, S.1    Schmidbauer, W.2    Volk, T.3
  • 9
    • 0034110143 scopus 로고    scopus 로고
    • The LMA 'ProSeal': A laryngeal mask with an oesophageal vent
    • Brain AIJ, Verghese C, Strube PJ (2000) The LMA 'ProSeal': a laryngeal mask with an oesophageal vent. British Journal of Anaesthesia. 84, 5, 650-654.
    • (2000) British Journal of Anaesthesia , vol.84 , Issue.5 , pp. 650-654
    • Aij, B.1    Verghese, C.2    Strube, P.J.3
  • 10
    • 0036164067 scopus 로고    scopus 로고
    • A multicentre study comparing the Proseal and classic laryngeal mask airway in anesthetized nonparalyzed patients
    • Brimacombe J, Keller C, Fullekrug B et al (2002a) A multicentre study comparing the Proseal and classic laryngeal mask airway in anesthetized nonparalyzed patients. Anesthesiology. 96, 2, 289-295.
    • (2002) Anesthesiology , vol.96 , Issue.2 , pp. 289-295
    • Brimacombe, J.1    Keller, C.2    Fullekrug, B.3
  • 11
    • 0036712121 scopus 로고    scopus 로고
    • A comparison of the Laryngeal Mask Airway ProSeal and the Laryngeal Tube Airway in paralyzed anesthetized adult patients undergoing pressure-controlled ventilation
    • Brimacombe JR, Keller C and Brimacombe L (2002b) A comparison of the Laryngeal Mask Airway ProSeal and the Laryngeal Tube Airway in paralyzed anesthetized adult patients undergoing pressure-controlled ventilation. Anesthesia and Analgesia. 95, 3, 770-776.
    • (2002) Anesthesia and Analgesia , vol.95 , Issue.3 , pp. 770-776
    • Brimacombe, J.R.1    Keller, C.2    Brimacombe, L.3
  • 12
    • 78349273893 scopus 로고    scopus 로고
    • Emergency airway placement by EMS providers: Comparison between Ling LT supralaryngeal airway and endotracheal intubation
    • Burns JB, Branson R, Barnes SL et al (2010) Emergency airway placement by EMS providers: comparison between Ling LT supralaryngeal airway and endotracheal intubation. Prehospital Disaster Medicine. 25, 1, 92-95.
    • (2010) Prehospital Disaster Medicine , vol.25 , Issue.1 , pp. 92-95
    • Burns, J.B.1    Branson, R.2    Barnes, S.L.3
  • 13
    • 33746095464 scopus 로고    scopus 로고
    • Success and complications rates with prehospital placement of an esophageal-tracheal Combitube as a rescue airway
    • Calkins TR, Miller K, Langdorf M (2006) Success and complications rates with prehospital placement of an esophageal-tracheal Combitube as a rescue airway. Prehospital and Disaster Medicine. 21, 2, 97-100.
    • (2006) Prehospital and Disaster Medicine , vol.21 , Issue.2 , pp. 97-100
    • Calkins, T.R.1    Miller, K.2    Langdorf, M.3
  • 14
    • 70350009630 scopus 로고    scopus 로고
    • Impact of chemical, biological, radiation, and nuclear personal protective equipment on the performance of low- and high-dexterity airway skills
    • Castle N, Owen R, Hann M et al (2009) Impact of chemical, biological, radiation, and nuclear personal protective equipment on the performance of low- and high-dexterity airway skills. Resuscitation. 80, 11, 1290-1295.
    • (2009) Resuscitation , vol.80 , Issue.11 , pp. 1290-1295
    • Castle, N.1    Owen, R.2    Hann, M.3
  • 15
    • 78349266744 scopus 로고    scopus 로고
    • Assessment of the speed and ease of insertion of three supraglottic airway devices by paramedics: A manikin study
    • doi:10.1136/emj.2009.084343
    • Castle N, Owen R, Hann M et al (2010) Assessment of the speed and ease of insertion of three supraglottic airway devices by paramedics: a manikin study. Emergency Medical Journal. doi:10.1136/emj.2009.084343.
    • (2010) Emergency Medical Journal
    • Castle, N.1    Owen, R.2    Hann, M.3
  • 18
    • 0035073784 scopus 로고    scopus 로고
    • A comparison of the intubating and standard laryngeal mask airways for airway management by inexperienced personnel
    • Choyce A, Avidan MS, Aguila M et al (2001) A comparison of the intubating and standard laryngeal mask airways for airway management by inexperienced personnel. Anaesthesia. 56, 4, 357-360.
    • (2001) Anaesthesia , vol.56 , Issue.4 , pp. 357-360
    • Choyce, A.1    Avidan, M.S.2    Aguila, M.3
  • 19
    • 78349267831 scopus 로고    scopus 로고
    • A comparative study of the COP RA perilaryngeal airway and Proseal laryngeal mask airway during laparoscopic cholecystectomy
    • Chung CJ, Jang MK, Choi SR et al (2009) A comparative study of the COP RA perilaryngeal airway and Proseal laryngeal mask airway during laparoscopic cholecystectomy. Korean Journal of Anesthesiology. 56, 2, 151-155.
    • (2009) Korean Journal of Anesthesiology , vol.56 , Issue.2 , pp. 151-155
    • Chung, C.J.1    Jang, M.K.2    Choi, S.R.3
  • 20
    • 61349150582 scopus 로고    scopus 로고
    • Decontamination of multiple casualties who are chemically contaminated: A challenge for acute hospitals
    • Clarke SFJ, Chilcott RP, Wilson JC et al (2008) Decontamination of multiple casualties who are chemically contaminated: a challenge for acute hospitals. Prehospital Disaster Medicine. 23, 2, 175-181.
    • (2008) Prehospital Disaster Medicine , vol.23 , Issue.2 , pp. 175-181
    • Clarke, S.F.J.1    Chilcott, R.P.2    Wilson, J.C.3
  • 21
    • 34548242591 scopus 로고    scopus 로고
    • ™ by one anaesthetist at a district general hospital
    • ™ by one anaesthetist at a district general hospital. British Journal of Anaesthesia. 99, 3, 436-439.
    • (2007) British Journal of Anaesthesia , vol.99 , Issue.3 , pp. 436-439
    • Cook, T.M.1    Gibbison, B.2
  • 22
    • 33646880431 scopus 로고    scopus 로고
    • New airways for resuscitation
    • Cook TM, Hommers C (2006) New Airways for Resuscitation. Resuscitation. 68, 3, 371-387.
    • (2006) Resuscitation , vol.68 , Issue.3 , pp. 371-387
    • Cook, T.M.1    Hommers, C.2
  • 23
    • 0036209037 scopus 로고    scopus 로고
    • Randomized crossover comparison of the ProSeal with the classic laryngeal mask airway in unparalysed anaethetized patients
    • Cook TM, Nolan JP, Verghese PJ et al (2002) Randomized crossover comparison of the ProSeal with the classic laryngeal mask airway in unparalysed anaethetized patients. British Journal of Anaesthesia. 88, 4, 537-533.
    • (2002) British Journal of Anaesthesia , vol.88 , Issue.4 , pp. 537-533
    • Cook, T.M.1    Nolan, J.P.2    Verghese, P.J.3
  • 24
    • 0242467651 scopus 로고    scopus 로고
    • Randomized crossover comparison of the ProSeal laryngeal mask airway with the laryngeal tube during anaesthesia with controlled ventilation
    • Cook TM, McKinstry C, Hardy R et al (2003a) Randomized crossover comparison of the ProSeal laryngeal mask airway with the laryngeal tube during anaesthesia with controlled ventilation. British Journal Anaesthesia. 91, 5, 678-683.
    • (2003) British Journal Anaesthesia , vol.91 , Issue.5 , pp. 678-683
    • Cook, T.M.1    McKinstry, C.2    Hardy, R.3
  • 25
    • 0041327830 scopus 로고    scopus 로고
    • Use of the ProSeal Laryngeal Mask Airway to initiate ventilation during intensive care and subsequent percutaneous tracheotomy
    • Cook TM, Taylor M, McKinstry C et al (2003b) Use of the ProSeal Laryngeal Mask Airway to initiate ventilation during intensive care and subsequent percutaneous tracheotomy. Anesthesia and Analgesia. 97, 3, 848-850.
    • (2003) Anesthesia and Analgesia , vol.97 , Issue.3 , pp. 848-850
    • Cook, T.M.1    Taylor, M.2    McKinstry, C.3
  • 26
    • 66049086029 scopus 로고    scopus 로고
    • Evaluation of the LMA Supreme in 100 non-paralysed patients
    • Cook TM, Gatward JJ, Handel J et al (2009) Evaluation of the LMA Supreme in 100 non-paralysed patients. Anaesthesia. 64, 11, 555-562.
    • (2009) Anaesthesia , vol.64 , Issue.11 , pp. 555-562
    • Cook, T.M.1    Gatward, J.J.2    Handel, J.3
  • 27
    • 0032983085 scopus 로고    scopus 로고
    • Airway management during cardiopulmonary resuscitation: A comparative study of bag-valve-mask, laryngeal mask airway and Combitube in a bench model
    • Dörges V, Sauer C, Ocker H et al (1999) Airway management during cardiopulmonary resuscitation: a comparative study of bag-valve-mask, laryngeal mask airway and Combitube in a bench model. Resuscitation. 41, 1, 63-69.
    • (1999) Resuscitation , vol.41 , Issue.1 , pp. 63-69
    • Dörges, V.1    Sauer, C.2    Ocker, H.3
  • 28
    • 0035192091 scopus 로고    scopus 로고
    • Intubating laryngeal mask airway, laryngeal tube, 1100ml self-inflating bag-alternatives for basic life support
    • Dörges V, Wenzel V, Schumann T et al (2001) Intubating laryngeal mask airway, laryngeal tube, 1100ml self-inflating bag-alternatives for basic life support. Resuscitation. 51, 2, 185-191.
    • (2001) Resuscitation , vol.51 , Issue.2 , pp. 185-191
    • Dörges, V.1    Wenzel, V.2    Schumann, T.3
  • 29
    • 1642540172 scopus 로고    scopus 로고
    • Antichemical protective gear prolongs time to successful airway management: A randomized, crossover study in humans
    • Flaishon R, Sotman A, Ben-Abraham R et al (2004) Antichemical protective gear prolongs time to successful airway management: a randomized, crossover study in humans. Anaesthesiology. 100, 2, 260-266.
    • (2004) Anaesthesiology , vol.100 , Issue.2 , pp. 260-266
    • Flaishon, R.1    Sotman, A.2    Ben-Abraham, R.3
  • 30
    • 70349328372 scopus 로고    scopus 로고
    • A comparison of the i-gel with the LMA-Unique in non-paralysed anaesthetised adult patients
    • Francksen H, Renner J, Hanss R et al (2009) A comparison of the i-gel with the LMA-Unique in non-paralysed anaesthetised adult patients. Anaesthesia. 64, 10, 1118-1124.
    • (2009) Anaesthesia , vol.64 , Issue.10 , pp. 1118-1124
    • Francksen, H.1    Renner, J.2    Hanss, R.3
  • 31
    • 33847369136 scopus 로고    scopus 로고
    • The iGEL supraglottic airway: A potential role for resuscitation?
    • Gabbott DA, Beringer R (2007) The iGEL supraglottic airway: a potential role for resuscitation? Resuscitation. 73, 1, 161-162.
    • (2007) Resuscitation , vol.73 , Issue.1 , pp. 161-162
    • Gabbott, D.A.1    Beringer, R.2
  • 32
    • 51349155510 scopus 로고    scopus 로고
    • ™ airway in one hundred non-paralysed patients
    • ™ airway in one hundred non-paralysed patients. Anaesthesia. 63, 10, 1124-1130.
    • (2008) Anaesthesia , vol.63 , Issue.10 , pp. 1124-1130
    • Gatward, J.J.1    Cook, T.M.2    Seller, C.3
  • 33
    • 0035055389 scopus 로고    scopus 로고
    • Case report: Nosocomial poisoning associated with emergency department treatment of organophosphate toxicity
    • Geller RJ, Singleton KL, Drenzek CL (2001) Case report: nosocomial poisoning associated with emergency department treatment of organophosphate toxicity. Clinical Toxology. 39, 1, 109-111.
    • (2001) Clinical Toxology , vol.39 , Issue.1 , pp. 109-111
    • Geller, R.J.1    Singleton, K.L.2    Drenzek, C.L.3
  • 34
    • 0036176297 scopus 로고    scopus 로고
    • Use of the laryngeal tube for out-of-hospital resuscitation
    • DOI 10.1016/S0300-9572(01)00472-5, PII S0300957201004725
    • Genzwuerker HV, Dhonau S, Ellinger K (2002) Use of the laryngeal tube for out-of-hospital resuscitation. Resuscitation. 53, 2, 221-224. (Pubitemid 34159034)
    • (2002) Resuscitation , vol.52 , Issue.2 , pp. 221-224
    • Genzwuerker, H.V.1    Dhonau, S.2    Ellinger, K.3
  • 35
    • 35348929442 scopus 로고    scopus 로고
    • Prospective randomized comparison of the new laryngeal tube suction LTS II and the LMA-ProSeal for elective surgical interventions
    • Genzwuerker HV, Altmayer S, Hinkelbein J et al (2007) Prospective randomized comparison of the new laryngeal tube suction LTS II and the LMA-ProSeal for elective surgical interventions. Acta Anaesthesiol Scandinavia. 51, 10, 1373-1377.
    • (2007) Acta Anaesthesiol Scandinavia , vol.51 , Issue.10 , pp. 1373-1377
    • Genzwuerker, H.V.1    Altmayer, S.2    Hinkelbein, J.3
  • 36
    • 40949114936 scopus 로고    scopus 로고
    • Case series: Protection from aspiration and failure of protection from aspiration with the i-gel airway
    • Gibson B, Cook TM, Seller C (2008) Case series: Protection from aspiration and failure of protection from aspiration with the i-gel airway. British Journal of Anaesthesia. 100, 3, 415-417.
    • (2008) British Journal of Anaesthesia , vol.100 , Issue.3 , pp. 415-417
    • Gibson, B.1    Cook, T.M.2    Seller, C.3
  • 37
    • 0036176322 scopus 로고    scopus 로고
    • The use of the laryngeal mask airway and Combitube in cardiopulmonary resuscitation: A national survey
    • Grayling M, Wilson IH, Thomas B (2002) The use of the laryngeal mask airway and Combitube in cardiopulmonary resuscitation: a national survey. Resuscitation. 52, 2, 183-186.
    • (2002) Resuscitation , vol.52 , Issue.2 , pp. 183-186
    • Grayling, M.1    Wilson, I.H.2    Thomas, B.3
  • 38
    • 0033922590 scopus 로고    scopus 로고
    • The oesophageal-tracheal Combitube Small Adult
    • Hartmann T, Krenn CG, Zoeggeler Z et al (2000) The oesophageal-tracheal Combitube Small Adult. Anaesthesia. 55, 7, 670-675.
    • (2000) Anaesthesia , vol.55 , Issue.7 , pp. 670-675
    • Hartmann, T.1    Krenn, C.G.2    Zoeggeler, Z.3
  • 39
    • 77953696687 scopus 로고    scopus 로고
    • A proposed framework for deciding suitable extraglottic airway devices for paramedic use
    • Hein C, Owen H, Plummer J (2010) A proposed framework for deciding suitable extraglottic airway devices for paramedic use. Resuscitation. 81, 7, 914.
    • (2010) Resuscitation , vol.81 , Issue.7 , pp. 914
    • Hein, C.1    Owen, H.2    Plummer, J.3
  • 40
    • 0025042186 scopus 로고
    • An evaluation of volume delivered by selected adult disposable resuscitators: The effects of hand size, number of hands used, and use of disposable medical gloves
    • Hess D, Spahr C (1990) An evaluation of volume delivered by selected adult disposable resuscitators: The effects of hand size, number of hands used, and use of disposable medical gloves. Respiratory Care. 35, 8, 800-805.
    • (1990) Respiratory Care , vol.35 , Issue.8 , pp. 800-805
    • Hess, D.1    Spahr, C.2
  • 41
    • 76149121811 scopus 로고    scopus 로고
    • Initial ventilation through laryngeal tube instead of facemask in out-of-hospital cardiopulmonary arrest is effective and safe
    • Heuer JF, Barwing J, Eich C et al (2010) Initial ventilation through laryngeal tube instead of facemask in out-of-hospital cardiopulmonary arrest is effective and safe. European Journal of Emergency Medicine. 17, 1, 10-15.
    • (2010) European Journal of Emergency Medicine , vol.17 , Issue.1 , pp. 10-15
    • Heuer, J.F.1    Barwing, J.2    Eich, C.3
  • 42
    • 67649992330 scopus 로고    scopus 로고
    • Students insert the laryngeal tube quicker and more often successful than the esophageal-tracheal Combitube in a manikin
    • Hüter L, Schwarzkopf K, Rodiger J et al (2009) Students insert the laryngeal tube quicker and more often successful than the esophageal-tracheal Combitube in a manikin. Resuscitation. 80, 8, 930-934.
    • (2009) Resuscitation , vol.80 , Issue.8 , pp. 930-934
    • Hüter, L.1    Schwarzkopf, K.2    Rodiger, J.3
  • 43
    • 0031979985 scopus 로고    scopus 로고
    • Use of tube condensation as an indicator of endotracheal tube placement
    • Kelly JJ, Eynon CA, Kaplan JL et al (1998) Use of tube condensation as an indicator of endotracheal tube placement. Annals of Emergency Medicine. 31, 5, 575-578.
    • (1998) Annals of Emergency Medicine , vol.31 , Issue.5 , pp. 575-578
    • Kelly, J.J.1    Eynon, C.A.2    Kaplan, J.L.3
  • 44
    • 21544445586 scopus 로고    scopus 로고
    • The use of laryngeal tube by nurses in out-of-hospital emergencies: Preliminary experience
    • Kette F, Reffo I, Giordani G et al (2005) The use of laryngeal tube by nurses in out-of-hospital emergencies: preliminary experience. Resuscitation. 66, 1, 21-25.
    • (2005) Resuscitation , vol.66 , Issue.1 , pp. 21-25
    • Kette, F.1    Reffo, I.2    Giordani, G.3
  • 45
    • 0030854420 scopus 로고    scopus 로고
    • Esophageal rupture associated with the use of the Combitube
    • Klein H, Williamson M, Sue-Ling H et al (1997) Esophageal rupture associated with the use of the Combitube. Anesthesia and Analgesia. 85, 4, 937-939.
    • (1997) Anesthesia and Analgesia , vol.85 , Issue.4 , pp. 937-939
    • Klein, H.1    Williamson, M.2    Sue-Ling, H.3
  • 46
    • 10344259692 scopus 로고    scopus 로고
    • Alternative management techniques for the difficult airway: Esophageal-tracheal Combitube
    • Kraft P, Schebesta K (2004) Alternative management techniques for the difficult airway: esophageal-tracheal Combitube. Current Opinion in Anaesthesiology. 17, 6, 499-504.
    • (2004) Current Opinion in Anaesthesiology , vol.17 , Issue.6 , pp. 499-504
    • Kraft, P.1    Schebesta, K.2
  • 47
    • 0033983618 scopus 로고    scopus 로고
    • Use of the intubating laryngeal mask airway by medical and nonmedical personnel
    • Levitan RM, Ochroch EA, Stuart S et al (2000) Use of the intubating laryngeal mask airway by medical and nonmedical personnel. American Journal of Emergency Medicine. 18, 1, 12-16.
    • (2000) American Journal of Emergency Medicine , vol.18 , Issue.1 , pp. 12-16
    • Levitan, R.M.1    Ochroch, E.A.2    Stuart, S.3
  • 48
    • 34147168645 scopus 로고    scopus 로고
    • The intubating laryngeal mask: Is there a role for paramedics?
    • Menzies R, Manji H (2007) The intubating laryngeal mask: is there a role for paramedics? Emergency Medicine Journal. 24, 3, 198-199.
    • (2007) Emergency Medicine Journal , vol.24 , Issue.3 , pp. 198-199
    • Menzies, R.1    Manji, H.2
  • 49
    • 68049139570 scopus 로고    scopus 로고
    • ™ Laryngeal mask airways in anaesthetized neonates and infants
    • ™ Laryngeal mask airways in anaesthetized neonates and infants. British Journal of Anaesthesia. 103, 2, 263-267.
    • (2009) British Journal of Anaesthesia , vol.103 , Issue.2 , pp. 263-267
    • Micaglio, M.1    Denardin, B.R.2
  • 50
    • 39749097284 scopus 로고    scopus 로고
    • Mass casualty chemical exposure and implications for respiratory failure
    • Muskat PC (2008) Mass casualty chemical exposure and implications for respiratory failure. Respiratory Care. 53, 1, 58-66.
    • (2008) Respiratory Care , vol.53 , Issue.1 , pp. 58-66
    • Muskat, P.C.1
  • 51
    • 0030807303 scopus 로고    scopus 로고
    • Sarin poisoning of a rescue team in the Matsumoto Sarin incident in Japan
    • Nakajima T, Sato S, Morita H et al (1997) Sarin poisoning of a rescue team in the Matsumoto Sarin incident in Japan. Occupational and Environmental Medicine. 54, 10, 697-701.
    • (1997) Occupational and Environmental Medicine , vol.54 , Issue.10 , pp. 697-701
    • Nakajima, T.1    Sato, S.2    Morita, H.3
  • 52
    • 78349249323 scopus 로고    scopus 로고
    • National Poisons Information Service, Last accessed: October 18 2010
    • National Poisons Information Service (2009) Health Protection Agency Annual Report 2008-2009. http://tiny.cc/gihxg (Last accessed: October 18 2010.)
    • (2009) Health Protection Agency Annual Report 2008-2009
  • 53
    • 28444490018 scopus 로고    scopus 로고
    • European Resuscitation Council guidelines for resuscitation 2005: Adult advanced life support
    • Nolan JP, Deakin CD, Soar J et al (2005) European Resuscitation Council guidelines for resuscitation 2005: adult advanced life support. Resuscitation. 67, Supplement 1, 39-86.
    • (2005) Resuscitation , vol.67 , Issue.SUPPL. 1 , pp. 39-86
    • Nolan, J.P.1    Deakin, C.D.2    Soar, J.3
  • 54
    • 0029564150 scopus 로고
    • Secondary exposure of medical staff to sarin vapour in the emergency department
    • Nozaki H, Hori S, Shinozawa Y et al (1995) Secondary exposure of medical staff to sarin vapour in the emergency department. Intensive Care Medicine. 21, 12, 1032-1035.
    • (1995) Intensive Care Medicine , vol.21 , Issue.12 , pp. 1032-1035
    • Nozaki, H.1    Hori, S.2    Shinozawa, Y.3
  • 55
    • 0033791861 scopus 로고    scopus 로고
    • Successful prehospital airway management by EMT-Ds using the Combitube
    • Ochs M, Vilke GM, Chan TC et al (2000) Successful prehospital airway management by EMT-Ds using the Combitube. Prehospital Emergency Care. 4, 4, 333-337.
    • (2000) Prehospital Emergency Care , vol.4 , Issue.4 , pp. 333-337
    • Ochs, M.1    Vilke, G.M.2    Chan, T.C.3
  • 56
    • 0036784844 scopus 로고    scopus 로고
    • A comparison of the laryngeal tube with the laryngeal mask airway during routine surgical procedures
    • Ocker H, Wenzel V, Schmucker P et al (2002) A comparison of the laryngeal tube with the laryngeal mask airway during routine surgical procedures. Anesthesia and Analgesia. 95, 4, 1094-1097.
    • (2002) Anesthesia and Analgesia , vol.95 , Issue.4 , pp. 1094-1097
    • Ocker, H.1    Wenzel, V.2    Schmucker, P.3
  • 57
    • 0032754991 scopus 로고    scopus 로고
    • Complications following the use of the Combitube, tracheal tube and laryngeal mask airway
    • Oczenski W, Krenn H, Dahaba AA et al (1999) Complications following the use of the Combitube, tracheal tube and laryngeal mask airway. Anaesthesia. 54, 12, 1161-1165.
    • (1999) Anaesthesia , vol.54 , Issue.12 , pp. 1161-1165
    • Oczenski, W.1    Krenn, H.2    Dahaba, A.A.3
  • 58
    • 0029848513 scopus 로고    scopus 로고
    • Report on 640 victims of the Tokyo subway sarin attack
    • Okumura T, Takasu N, Ishimatsu S et al (1996) Report on 640 victims of the Tokyo subway sarin attack. Annals of Emergency Medicine. 28, 2, 129-136.
    • (1996) Annals of Emergency Medicine , vol.28 , Issue.2 , pp. 129-136
    • Okumura, T.1    Takasu, N.2    Ishimatsu, S.3
  • 59
    • 0035178395 scopus 로고    scopus 로고
    • Airway management with the Combitube during anaesthesia and in an emergency
    • Paventi S, Liturri S, Colio B et al (2001) Airway management with the Combitube during anaesthesia and in an emergency. Resuscitation. 51, 2, 129-133.
    • (2001) Resuscitation , vol.51 , Issue.2 , pp. 129-133
    • Paventi, S.1    Liturri, S.2    Colio, B.3
  • 60
    • 1142287490 scopus 로고    scopus 로고
    • Evaluation of the Intubating Laryngeal Mask Airway used by occasional intubators in simulated trauma
    • Reeves MD, Skinner MW, Ginifer CJ (2004) Evaluation of the Intubating Laryngeal Mask Airway used by occasional intubators in simulated trauma. Anaesthesia in Intensive Care. 32, 1, 73-76.
    • (2004) Anaesthesia in Intensive Care , vol.32 , Issue.1 , pp. 73-76
    • Reeves, M.D.1    Skinner, M.W.2    Ginifer, C.J.3
  • 62
    • 41349109832 scopus 로고    scopus 로고
    • A new single use supraglottic airway device with a noninflatable cuff and an esophageal vent: An observational study of the i-gel
    • Richez B, Saltel L, Banchereau F et al (2008) A new single use supraglottic airway device with a noninflatable cuff and an esophageal vent: an observational study of the i-gel. Anesthesia and Analgesia. 106, 4, 1137-1139.
    • (2008) Anesthesia and Analgesia , vol.106 , Issue.4 , pp. 1137-1139
    • Richez, B.1    Saltel, L.2    Banchereau, F.3
  • 63
    • 0142106944 scopus 로고    scopus 로고
    • A review of emergency equipment carried and procedures performed by UK front line paramedics
    • Roberts K, Allison KP, Porter KM (2003) A review of emergency equipment carried and procedures performed by UK front line paramedics. Resuscitation. 58, 2, 153-158.
    • (2003) Resuscitation , vol.58 , Issue.2 , pp. 153-158
    • Roberts, K.1    Allison, K.P.2    Porter, K.M.3
  • 64
    • 0042338743 scopus 로고    scopus 로고
    • Nerve agent attacks on children: Diagnosis and management
    • Rotenberg JS, Newman J (2003) Nerve agent attacks on children: diagnosis and management. Pediatrics. 112, 3, 648-658 .
    • (2003) Pediatrics , vol.112 , Issue.3 , pp. 648-658
    • Rotenberg, J.S.1    Newman, J.2
  • 65
    • 0030622475 scopus 로고    scopus 로고
    • The PTL , Combitube, Laryngeal Mask and oral airway: A randomized prehospital comparative study of ventilatory device effectiveness and cost-effectiveness in 470 cases of cardiorespiratory arrests
    • Rumball CJ, MacDonald D (1997) The PTL , Combitube, Laryngeal Mask and oral airway: a randomized prehospital comparative study of ventilatory device effectiveness and cost-effectiveness in 470 cases of cardiorespiratory arrests. Prehospital Emergency Care. 1, 1, 1-10.
    • (1997) Prehospital Emergency Care , vol.1 , Issue.1 , pp. 1-10
    • Rumball, C.J.1    MacDonald, D.2
  • 67
    • 77951917486 scopus 로고    scopus 로고
    • Out-of-hospital airway management by paramedics and emergency physicians using laryngeal tubes
    • Schalk R, Byhahn C, Fausel F et al (2010) Out-of-hospital airway management by paramedics and emergency physicians using laryngeal tubes. Resuscitation. 81, 3, 323-326.
    • (2010) Resuscitation , vol.81 , Issue.3 , pp. 323-326
    • Schalk, R.1    Byhahn, C.2    Fausel, F.3
  • 68
    • 67349198919 scopus 로고    scopus 로고
    • Laryngeal tube suction II for difficult airway management in neonates and small infants
    • Scheller B, Schalt R, Byhahn C et al (2009) Laryngeal tube suction II for difficult airway management in neonates and small infants. Resuscitation. 80, 7, 805-810.
    • (2009) Resuscitation , vol.80 , Issue.7 , pp. 805-810
    • Scheller, B.1    Schalt, R.2    Byhahn, C.3
  • 69
    • 0037038392 scopus 로고    scopus 로고
    • Hostage deaths put gas weapons in spotlight
    • Schiermeier Q (2002) Hostage deaths put gas weapons in spotlight. Nature. 420, 6911, 7.
    • (2002) Nature , vol.420 , Issue.6911 , pp. 7
    • Schiermeier, Q.1
  • 70
    • 66349096639 scopus 로고    scopus 로고
    • Prehospital airway management on rescue helicopters in the United Kingdom
    • Schmid M, Mang H, Ely K et al (2009) Prehospital airway management on rescue helicopters in the United Kingdom. Anaesthesia. 64, 6, 625-631.
    • (2009) Anaesthesia , vol.64 , Issue.6 , pp. 625-631
    • Schmid, M.1    Mang, H.2    Ely, K.3
  • 71
    • 57349166088 scopus 로고    scopus 로고
    • Oesophageal seal of the novel supralaryngeal airway device Igel in comparison with laryngeal mask airways classic and Proseal using cadaver model
    • Schmidbauer W, Bercker S, Volk T et al (2009) Oesophageal seal of the novel supralaryngeal airway device Igel in comparison with laryngeal mask airways classic and Proseal using cadaver model. British Journal of Anaesthesia. 102, 1, 135-139.
    • (2009) British Journal of Anaesthesia , vol.102 , Issue.1 , pp. 135-139
    • Schmidbauer, W.1    Bercker, S.2    Volk, T.3
  • 72
    • 77953744572 scopus 로고    scopus 로고
    • The supraglottic airway I-gel in comparison with ProSeal laryngeal mask airway and classic laryngeal mask airway in anaesthetized patients
    • Shin WJ, Cheong YS, Yang HS et al (2009) The supraglottic airway I-gel in comparison with ProSeal laryngeal mask airway and classic laryngeal mask airway in anaesthetized patients. European Journal of Anaesthesiology. 27, 7, 598-601.
    • (2009) European Journal of Anaesthesiology , vol.27 , Issue.7 , pp. 598-601
    • Shin, W.J.1    Cheong, Y.S.2    Yang, H.S.3
  • 73
    • 34250020474 scopus 로고    scopus 로고
    • The Igel supraglottic and resuscitation: Some initial thoughts
    • Soar J (2007) The Igel supraglottic and resuscitation: some initial thoughts. Resuscitation. 74, 1, 197.
    • (2007) Resuscitation , vol.74 , Issue.1 , pp. 197
    • Soar, J.1
  • 74
    • 77951891309 scopus 로고    scopus 로고
    • Gastric perforation after cardiopulmonary resuscitation: Review of the literature
    • Spoormans I, Van Hoorenbeeck K, Balliu L et al (2010) Gastric perforation after cardiopulmonary resuscitation: Review of the literature. Resuscitation. 81, 3, 272-280.
    • (2010) Resuscitation , vol.81 , Issue.3 , pp. 272-280
    • Spoormans, I.1    Van Hoorenbeeck, K.2    Balliu, L.3
  • 75
    • 1242319381 scopus 로고    scopus 로고
    • Secondary contamination in organophosphate poisioning: Analysis of an incident
    • Stacey R, Morfey D, Payne S (2004) Secondary contamination in organophosphate poisioning: analysis of an incident. Quarterly Journal of Medicine. 97, 10, 75-80.
    • (2004) Quarterly Journal of Medicine , vol.97 , Issue.10 , pp. 75-80
    • Stacey, R.1    Morfey, D.2    Payne, S.3
  • 76
    • 0031725203 scopus 로고    scopus 로고
    • The incidence of regurgitation during cardiopulmonary resuscitation: A comparison between the bag valve mask and laryngeal mask
    • Stone BJ, Chantler PJ, Baskett PJ (1998) The incidence of regurgitation during cardiopulmonary resuscitation: a comparison between the bag valve mask and laryngeal mask. Resuscitation. 38, 1, 3-6.
    • (1998) Resuscitation , vol.38 , Issue.1 , pp. 3-6
    • Stone, B.J.1    Chantler, P.J.2    Baskett, P.J.3
  • 77
    • 0242469049 scopus 로고    scopus 로고
    • Intubating laryngeal mask airway verses laryngoscope and endotracheal intubation in the nuclear, biological, and chemical environment
    • Talbot TS, Cuena PJ, Wedmore IS (2003) Intubating laryngeal mask airway verses laryngoscope and endotracheal intubation in the nuclear, biological, and chemical environment. Military Medicine. 168, 11, 876-879.
    • (2003) Military Medicine , vol.168 , Issue.11 , pp. 876-879
    • Talbot, T.S.1    Cuena, P.J.2    Wedmore, I.S.3
  • 78
    • 70449703317 scopus 로고    scopus 로고
    • Pre-hospital resuscitation using the Igel
    • Thomas M, Benger J (2009) Pre-hospital resuscitation using the Igel. Resuscitation. 80, 12, 1437.
    • (2009) Resuscitation , vol.80 , Issue.12 , pp. 1437
    • Thomas, M.1    Benger, J.2
  • 79
    • 34547887992 scopus 로고    scopus 로고
    • Intubating laryngeal mask airway for difficult out-of-hospital airway management: A prospective evaluation
    • Timmermann A, Russo SG, Rosenblatt WH et al (2007) Intubating laryngeal mask airway for difficult out-of-hospital airway management: a prospective evaluation. British Journal of Anaesthesia. 99, 2, 286-291.
    • (2007) British Journal of Anaesthesia , vol.99 , Issue.2 , pp. 286-291
    • Timmermann, A.1    Russo, S.G.2    Rosenblatt, W.H.3
  • 80
    • 69849105213 scopus 로고    scopus 로고
    • The King LT versus the Combitube: Flight crew performance and preference
    • Tumpach EA, Lutes ML, Ford D et al (2009) The King LT versus the Combitube: flight crew performance and preference. Prehospital Emergency Care. 13, 3, 324-328.
    • (2009) Prehospital Emergency Care , vol.13 , Issue.3 , pp. 324-328
    • Tumpach, E.A.1    Lutes, M.L.2    Ford, D.3
  • 81
    • 71749104416 scopus 로고    scopus 로고
    • Randomised crossover comparison between the i-gel and the LMA-Unique in anaesthetized, paralysed adults
    • Uppal V, Gangaiah S, Fletcher G et al (2009) Randomised crossover comparison between the i-gel and the LMA-Unique in anaesthetized, paralysed adults. British Journal of Anaesthesia. 103, 6, 882-885.
    • (2009) British Journal of Anaesthesia , vol.103 , Issue.6 , pp. 882-885
    • Uppal, V.1    Gangaiah, S.2    Fletcher, G.3
  • 82
    • 2642707487 scopus 로고    scopus 로고
    • Complications associated with the use of the esophageal-tracheal Combitube
    • Vézina D, Lessard MR, Bussieres J et al (1998) Complications associated with the use of the esophageal-tracheal Combitube. Canadian Journal of Anaesthesia. 45, 1, 76-80.
    • (1998) Canadian Journal of Anaesthesia , vol.45 , Issue.1 , pp. 76-80
    • Vézina, D.1    Lessard, M.R.2    Bussieres, J.3
  • 83
    • 33947719191 scopus 로고    scopus 로고
    • Complications associated with the Esophageal-Tracheal Combitube in the prehospital setting
    • Vézina M, Trepanier CA, Nicole PC et al (2007) Complications associated with the Esophageal-Tracheal Combitube in the prehospital setting. Canadian Journal of Anaesthesia. 54, 2, 124-128.
    • (2007) Canadian Journal of Anaesthesia , vol.54 , Issue.2 , pp. 124-128
    • Vézina, M.1    Trepanier, C.A.2    Nicole, P.C.3
  • 84
    • 0029951072 scopus 로고    scopus 로고
    • Sarin: Guidelines on the management of victims of a nerve gas attack
    • Volans AP (1996) Sarin: guidelines on the management of victims of a nerve gas attack. Journal of Accident and Emergency Medicine. 13, 6, 202-206.
    • (1996) Journal of Accident and Emergency Medicine , vol.13 , Issue.6 , pp. 202-206
    • Volans, A.P.1
  • 85
    • 0035192091 scopus 로고    scopus 로고
    • Intubating laryngeal mask airway, laryngeal tube, 1100ml self-inflating bag-alternatives for basic life support
    • Volker D, Volker W, Schumann T et al (2001) Intubating laryngeal mask airway, laryngeal tube, 1100ml self-inflating bag-alternatives for basic life support. Resuscitation. 51, 2, 185-191.
    • (2001) Resuscitation , vol.51 , Issue.2 , pp. 185-191
    • Volker, D.1    Volker, W.2    Schumann, T.3
  • 86
    • 0028795957 scopus 로고
    • Effectiveness of the self-inflating bulb for verification of proper placement of the Esophageal Tracheal Combitube
    • Wafai Y, Salem MR, Baraka AB et al (1995) Effectiveness of the self-inflating bulb for verification of proper placement of the Esophageal Tracheal Combitube. Anesthesia and Analgesia. 80, 1, 122-126.
    • (1995) Anesthesia and Analgesia , vol.80 , Issue.1 , pp. 122-126
    • Wafai, Y.1    Salem, M.R.2    Baraka, A.B.3
  • 87
    • 66049110561 scopus 로고    scopus 로고
    • Tracheal intubation and alternative airway management devices used by healthcare professionals with different level of pre-existing skills: A manikin study
    • Wahlen BM, Roewer N, Lange M et al (2009) Tracheal intubation and alternative airway management devices used by healthcare professionals with different level of pre-existing skills: a manikin study. Anaesthesia. 64, 5, 549-554.
    • (2009) Anaesthesia , vol.64 , Issue.5 , pp. 549-554
    • Wahlen, B.M.1    Roewer, N.2    Lange, M.3
  • 89
    • 0037407650 scopus 로고    scopus 로고
    • Unexpected 'gas' casualties in Moscow: A medical toxicology perspective
    • Wax PM, Becker CE, Curry SC (2003) Unexpected 'gas' casualties in Moscow: a medical toxicology perspective. Annals of Emergency Medicine. 41, 5, 700-705.
    • (2003) Annals of Emergency Medicine , vol.41 , Issue.5 , pp. 700-705
    • Wax, P.M.1    Becker, C.E.2    Curry, S.C.3
  • 90
    • 0029286550 scopus 로고
    • Assessment of pulmonary mechanics and gastric inflation pressure during mask ventilation
    • Weiler N, Heinrichs W, Dick W (1995) Assessment of pulmonary mechanics and gastric inflation pressure during mask ventilation. Prehospital Disaster Medicine. 10, 2, 101-105.
    • (1995) Prehospital Disaster Medicine , vol.10 , Issue.2 , pp. 101-105
    • Weiler, N.1    Heinrichs, W.2    Dick, W.3
  • 91
    • 0035016287 scopus 로고    scopus 로고
    • The respiratory system during resuscitation: A review of the history, risk of infection during assisted ventilation, respiratory mechanics and ventilation strategies for patients with unprotected airway
    • Wenzel V, Idris AH, Dorges V et al (2001) The respiratory system during resuscitation: a review of the history, risk of infection during assisted ventilation, respiratory mechanics and ventilation strategies for patients with unprotected airway. Resuscitation. 49, 2, 123-134.
    • (2001) Resuscitation , vol.49 , Issue.2 , pp. 123-134
    • Wenzel, V.1    Idris, A.H.2    Dorges, V.3
  • 92
    • 0031031588 scopus 로고    scopus 로고
    • A comparison of three methods of bag valve mask ventilation
    • Wheatley S, Thomas AN, Taylor RJ et al (1997) A comparison of three methods of bag valve mask ventilation. Resuscitation. 33, 3, 207-210.
    • (1997) Resuscitation , vol.33 , Issue.3 , pp. 207-210
    • Wheatley, S.1    Thomas, A.N.2    Taylor, R.J.3
  • 93
    • 36649033157 scopus 로고    scopus 로고
    • A comparison of the laryngeal tube-S and Proseal laryngeal mask during outpatient surgical procedures
    • Zand F, Amini A, Sadeghi S, et al (2007) A comparison of the laryngeal tube-S and Proseal laryngeal mask during outpatient surgical procedures. European Journal of Anaesthesia. 24, 10, 847-852.
    • (2007) European Journal of Anaesthesia , vol.24 , Issue.10 , pp. 847-852
    • Zand, F.1    Amini, A.2    Sadeghi, S.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.