메뉴 건너뛰기




Volumn 27, Issue 9, 2010, Pages 1141-1146

Transesophageal echocardiography for the diagnosis of pulmonary vein stenosis after catheter ablation of atrial fibrillation: A systematic review

Author keywords

atrial fibrillation; pulmonary vein stenosis; transesophageal echocardiography

Indexed keywords

CATHETER ABLATION; CAVOGRAPHY; CLINICAL ASSESSMENT TOOL; COMPUTER ASSISTED TOMOGRAPHY; DIAGNOSTIC ACCURACY; DIAGNOSTIC VALUE; DISEASE SEVERITY; DOPPLER FLOWMETRY; HEART ATRIUM FIBRILLATION; HUMAN; IMAGE QUALITY; NUCLEAR MAGNETIC RESONANCE IMAGING; PRIORITY JOURNAL; PULMONARY VEIN ANGIOGRAPHY; PULMONARY VEIN OBSTRUCTION; QUALITY CONTROL; REVIEW; SENSITIVITY AND SPECIFICITY; SYSTEMATIC REVIEW; TRANSESOPHAGEAL ECHOCARDIOGRAPHY;

EID: 78349252042     PISSN: 07422822     EISSN: 15408175     Source Type: Journal    
DOI: 10.1111/j.1540-8175.2010.01250.x     Document Type: Review
Times cited : (21)

References (34)
  • 1
    • 0035832261 scopus 로고    scopus 로고
    • Prevalence of diagnosed atrial fibrillation in adults: National implications for rhythm management and stroke prevention: The AnTicoagulation and Risk Factors in Atrial Fibrillation (ATRIA) Study
    • Go AS, Hylek EM, Phillips KA, et al,: Prevalence of diagnosed atrial fibrillation in adults: National implications for rhythm management and stroke prevention: The AnTicoagulation and Risk Factors in Atrial Fibrillation (ATRIA) Study. JAMA 2001; 285: 2370-2375.
    • (2001) JAMA , vol.285 , pp. 2370-2375
    • Go, A.S.1    Hylek, E.M.2    Phillips, K.A.3
  • 2
    • 0032497292 scopus 로고    scopus 로고
    • Impact of atrial fibrillation on the risk of death: The Framingham Heart Study
    • Benjamin EJ, Wolf PA, D'Agostino RB, et al,: Impact of atrial fibrillation on the risk of death: The Framingham Heart Study. Circulation 1998; 98: 946-952.
    • (1998) Circulation , vol.98 , pp. 946-952
    • Benjamin, E.J.1    Wolf, P.A.2    D'Agostino, R.B.3
  • 3
    • 0032480265 scopus 로고    scopus 로고
    • Spontaneous initiation of atrial fibrillation by ectopic beats originating from pulmonary veins
    • Haissaguerre M, Jais P, Shah DC, et al,: Spontaneous initiation of atrial fibrillation by ectopic beats originating from pulmonary veins. N Engl J Med 1998; 339: 659-666.
    • (1998) N Engl J Med , vol.339 , pp. 659-666
    • Haissaguerre, M.1    Jais, P.2    Shah, D.C.3
  • 4
    • 0033517860 scopus 로고    scopus 로고
    • Initiation of atrial fibrillation by ectopic beats originating from the pulmonary veins: Electrophysiological characteristics, pharmacological responses, and effects of radiofrequency ablation
    • Chen SA, Hsieh MH, Tai CT, et al,: Initiation of atrial fibrillation by ectopic beats originating from the pulmonary veins: Electrophysiological characteristics, pharmacological responses, and effects of radiofrequency ablation. Circulation 1999; 100: 1879-1886.
    • (1999) Circulation , vol.100 , pp. 1879-1886
    • Chen, S.A.1    Hsieh, M.H.2    Tai, C.T.3
  • 5
    • 0038300657 scopus 로고    scopus 로고
    • Mortality, morbidity, and quality of life after circumferential pulmonary vein ablation for atrial fibrillation: Outcomes from a controlled nonrandomized long-term study
    • Pappone C, Rosanio S, Augello G, et al,: Mortality, morbidity, and quality of life after circumferential pulmonary vein ablation for atrial fibrillation: Outcomes from a controlled nonrandomized long-term study. J Am Coll Cardiol 2003; 42: 185-197.
    • (2003) J Am Coll Cardiol , vol.42 , pp. 185-197
    • Pappone, C.1    Rosanio, S.2    Augello, G.3
  • 6
    • 21144444031 scopus 로고    scopus 로고
    • Radiofrequency ablation vs antiarrhythmic drugs as first-line treatment of symptomatic atrial fibrillation: A randomized trial
    • Wazni OM, Marrouche NF, Martin DO, et al,: Radiofrequency ablation vs antiarrhythmic drugs as first-line treatment of symptomatic atrial fibrillation: A randomized trial. JAMA 2005; 293: 2634-2640.
    • (2005) JAMA , vol.293 , pp. 2634-2640
    • Wazni, O.M.1    Marrouche, N.F.2    Martin, D.O.3
  • 7
    • 54949104627 scopus 로고    scopus 로고
    • Pulmonary-vein isolation for atrial fibrillation in patients with heart failure
    • Khan MN, Jaàs P, Cummings J, et al,: Pulmonary-vein isolation for atrial fibrillation in patients with heart failure. N Engl J Med 2008; 359: 1778-1785.
    • (2008) N Engl J Med , vol.359 , pp. 1778-1785
    • Khan, M.N.1    Jaàs, P.2    Cummings, J.3
  • 8
    • 9144219758 scopus 로고    scopus 로고
    • Pulmonary vein stenosis after radiofrequency ablation of atrial fibrillation: Functional characterization, evolution, and influence of the ablation strategy
    • Saad EB, Rossillo A, Saad CP, et al,: Pulmonary vein stenosis after radiofrequency ablation of atrial fibrillation: Functional characterization, evolution, and influence of the ablation strategy. Circulation 2003; 108: 3102-3107.
    • (2003) Circulation , vol.108 , pp. 3102-3107
    • Saad, E.B.1    Rossillo, A.2    Saad, C.P.3
  • 9
    • 0034886462 scopus 로고    scopus 로고
    • Acquired pulmonary vein stenosis after radiofrequency catheter ablation of paroxysmal atrial fibrillation
    • Yu WC, Hsu TL, Tai CT, et al,: Acquired pulmonary vein stenosis after radiofrequency catheter ablation of paroxysmal atrial fibrillation. J Cardiovasc Electrophysiol 2001; 12: 887-892.
    • (2001) J Cardiovasc Electrophysiol , vol.12 , pp. 887-892
    • Yu, W.C.1    Hsu, T.L.2    Tai, C.T.3
  • 10
    • 0343729318 scopus 로고    scopus 로고
    • Electrophysiological endpoint for catheter ablation of atrial fibrillation initiated from multiple pulmonary venous foci
    • Haàssaguerre M, Jaàs P, Shah DC, et al,: Electrophysiological endpoint for catheter ablation of atrial fibrillation initiated from multiple pulmonary venous foci. Circulation 2000; 101: 1409-1417.
    • (2000) Circulation , vol.101 , pp. 1409-1417
    • Haàssaguerre, M.1    Jaàs, P.2    Shah, D.C.3
  • 11
    • 34247523351 scopus 로고    scopus 로고
    • Venice Chart international consensus document on atrial fibrillation ablation
    • Natale A, Raviele A, Arentz T, et al,: Venice Chart international consensus document on atrial fibrillation ablation. J Cardiovasc Electrophysiol 2007; 18: 560-580.
    • (2007) J Cardiovasc Electrophysiol , vol.18 , pp. 560-580
    • Natale, A.1    Raviele, A.2    Arentz, T.3
  • 12
    • 27644543081 scopus 로고    scopus 로고
    • Pulmonary vein stenosis following catheter ablation of atrial fibrillation
    • DOI 10.1097/01.hco.0000179816.80576.3c
    • Purerfellner H, Martinek M,: Pulmonary vein stenosis following catheter ablation of atrial fibrillation. Curr Opin Cardiol 2005; 20: 484-490. (Pubitemid 41565330)
    • (2005) Current Opinion in Cardiology , vol.20 , Issue.6 , pp. 484-490
    • Purerfellner, H.1    Martinek, M.2
  • 13
    • 1642576079 scopus 로고    scopus 로고
    • Pulmonary vein stenosis after catheter ablation of atrial fibrillation: Emergence of a new clinical syndrome
    • Saad EB, Marrouche NF, Saad CP, et al,: Pulmonary vein stenosis after catheter ablation of atrial fibrillation: Emergence of a new clinical syndrome. Ann Intern Med 2003; 138: 634-638.
    • (2003) Ann Intern Med , vol.138 , pp. 634-638
    • Saad, E.B.1    Marrouche, N.F.2    Saad, C.P.3
  • 14
    • 20444375811 scopus 로고    scopus 로고
    • Transesophageal echocardiography in comparison with magnetic resonance imaging in the diagnosis of pulmonary vein stenosis after radiofrequency ablation therapy
    • Jander N, Minners J, Arentz T, et al,: Transesophageal echocardiography in comparison with magnetic resonance imaging in the diagnosis of pulmonary vein stenosis after radiofrequency ablation therapy. J Am Soc Echocardiogr 2005; 18: 654-659.
    • (2005) J Am Soc Echocardiogr , vol.18 , pp. 654-659
    • Jander, N.1    Minners, J.2    Arentz, T.3
  • 15
    • 34247273983 scopus 로고    scopus 로고
    • Detection of pulmonary vein stenosis by transesophageal echocardiography: Comparison with multidetector computed tomography
    • Sigurdsson G, Troughton RW, Xu XF, et al,: Detection of pulmonary vein stenosis by transesophageal echocardiography: Comparison with multidetector computed tomography. Am Heart J 2007; 153: 800-806.
    • (2007) Am Heart J , vol.153 , pp. 800-806
    • Sigurdsson, G.1    Troughton, R.W.2    Xu, X.F.3
  • 16
    • 34249700838 scopus 로고    scopus 로고
    • Transesophageal echocardiography: A follow-up tool after catheter ablation of atrial fibrillation and interventional therapy of pulmonary vein stenosis and occlusion
    • Schneider C, Ernst S, Malisius R, et al,: Transesophageal echocardiography: A follow-up tool after catheter ablation of atrial fibrillation and interventional therapy of pulmonary vein stenosis and occlusion. J Interv Card Electrophysiol 2007; 18: 195-205.
    • (2007) J Interv Card Electrophysiol , vol.18 , pp. 195-205
    • Schneider, C.1    Ernst, S.2    Malisius, R.3
  • 17
    • 33750437424 scopus 로고    scopus 로고
    • Transesophageal echocardiography: A screening method for pulmonary vein stenosis after catheter ablation of atrial fibrillation
    • Schneider C, Ernst S, Bahlmann E, et al,: Transesophageal echocardiography: A screening method for pulmonary vein stenosis after catheter ablation of atrial fibrillation. Eur J Echocardiogr 2006; 7: 447-456.
    • (2006) Eur J Echocardiogr , vol.7 , pp. 447-456
    • Schneider, C.1    Ernst, S.2    Bahlmann, E.3
  • 18
    • 10744231880 scopus 로고    scopus 로고
    • ACC/AHA/ASE 2003 Guideline Update for the Clinical Application of Echocardiography: Summary article. A report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (ACC/AHA/ASE Committee to Update the 1997 Guidelines for the Clinical Application of Echocardiography)
    • Cheitlin MD, Armstrong WF, Aurigemma GP, et al,: ACC/AHA/ASE 2003 Guideline Update for the Clinical Application of Echocardiography: Summary article. A report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (ACC/AHA/ASE Committee to Update the 1997 Guidelines for the Clinical Application of Echocardiography). J Am Soc Echocardiogr 2003; 16: 1091-1110.
    • (2003) J Am Soc Echocardiogr , vol.16 , pp. 1091-1110
    • Cheitlin, M.D.1    Armstrong, W.F.2    Aurigemma, G.P.3
  • 19
    • 34248664839 scopus 로고    scopus 로고
    • American College of Cardiology; American Heart Association Task Force; European Society of Cardiology Committee for Practice Guidelines; European Heart Rhythm Association; Heart Rhythm Society. ACC/AHA/ESC 2006 guidelines for the management of patients with atrial fibrillation: A report of the American College of Cardiology
    • e354 /American Heart Association Task Force on practice guidelines and the European Society of Cardiology Committee for Practice Guidelines (Writing Committee to Revise the 2001 Guidelines for the Management of Patients with Atrial Fibrillation) Developed in collaboration with the European Heart Rhythm Association and the Heart Rhythm Society
    • Fuster V, Rydén LE, Cannom DS, et al,: American College of Cardiology; American Heart Association Task Force; European Society of Cardiology Committee for Practice Guidelines; European Heart Rhythm Association; Heart Rhythm Society. ACC/AHA/ESC 2006 guidelines for the management of patients with atrial fibrillation: A report of the American College of Cardiology/American Heart Association Task Force on practice guidelines and the European Society of Cardiology Committee for Practice Guidelines (Writing Committee to Revise the 2001 Guidelines for the Management of Patients With Atrial Fibrillation) Developed in collaboration with the European Heart Rhythm Association and the Heart Rhythm Society. Circulation 2006; 114: e257-e354.
    • (2006) Circulation , vol.114 , pp. 257
    • Fuster, V.1    Rydén, L.E.2    Cannom, D.S.3
  • 20
    • 34249814933 scopus 로고    scopus 로고
    • HRS/EHRA/ECAS expert Consensus Statement on catheter and surgical ablation of atrial fibrillation: Recommendations for personnel, policy, procedures and follow-up. A report of the Heart Rhythm Society (HRS) Task Force on catheter and surgical ablation of atrial fibrillation
    • Calkins H, Brugada J, Packer DL, et al,: HRS/EHRA/ECAS expert Consensus Statement on catheter and surgical ablation of atrial fibrillation: Recommendations for personnel, policy, procedures and follow-up. A report of the Heart Rhythm Society (HRS) Task Force on catheter and surgical ablation of atrial fibrillation. Heart Rhythm 2007; 4: 816-861.
    • (2007) Heart Rhythm , vol.4 , pp. 816-861
    • Calkins, H.1    Brugada, J.2    Packer, D.L.3
  • 21
    • 2942700307 scopus 로고    scopus 로고
    • The development of QUADAS: A tool for the quality assessment of studies of diagnostic accuracy included in systematic reviews
    • Whiting P, Rutjes AW, Reitsma JB, et al,: The development of QUADAS: A tool for the quality assessment of studies of diagnostic accuracy included in systematic reviews. BMC Med Res Methodol 2003; 3: 25-37.
    • (2003) BMC Med Res Methodol , vol.3 , pp. 25-37
    • Whiting, P.1    Rutjes, A.W.2    Reitsma, J.B.3
  • 22
    • 0002477735 scopus 로고    scopus 로고
    • Rationale, potentials, and promise of systematic reviews
    • In Egger M., Smith G.D., and Altman D.G. (eds):, 2nd Ed. London: BMJ Publishing Group, pp.
    • Egger M, Smith GD, O'Rourke K,: Rationale, potentials, and promise of systematic reviews. In, Egger M, Smith GD, and, Altman DG, (eds): Systematic Reviews in Health Care: Meta-analysis in Context, 2nd Ed. London: BMJ Publishing Group, 2001, pp. 4-5.
    • (2001) Systematic Reviews in Health Care: Meta-analysis in Context , pp. 4-5
    • Egger, M.1    Smith, G.D.2    O'Rourke, K.3
  • 23
    • 13444259334 scopus 로고    scopus 로고
    • Clinical presentation, investigation, and management of pulmonary vein stenosis complicating ablation for atrial fibrillation
    • Packer DL, Keelan P, Munger TM, et al,: Clinical presentation, investigation, and management of pulmonary vein stenosis complicating ablation for atrial fibrillation. Circulation 2005; 111: 546-554.
    • (2005) Circulation , vol.111 , pp. 546-554
    • Packer, D.L.1    Keelan, P.2    Munger, T.M.3
  • 24
    • 0037991427 scopus 로고    scopus 로고
    • Incidence of pulmonary vein stenosis 2 years after radiofrequency catheter ablation of refractory atrial fibrillation
    • Arentz T, Jander N, Von Rosenthal J, et al,: Incidence of pulmonary vein stenosis 2 years after radiofrequency catheter ablation of refractory atrial fibrillation. Eur Heart J 2003; 24: 963-969.
    • (2003) Eur Heart J , vol.24 , pp. 963-969
    • Arentz, T.1    Jander, N.2    Von Rosenthal, J.3
  • 25
    • 55249126036 scopus 로고    scopus 로고
    • Role of transesophageal echocardiography in evaluating the effect of catheter ablation of atrial fibrillation on anatomy and function of the pulmonary veins
    • De Piccoli B, Rossillo A, Zanella C, et al,: Role of transesophageal echocardiography in evaluating the effect of catheter ablation of atrial fibrillation on anatomy and function of the pulmonary veins. Europace 2008; 10: 1079-1084.
    • (2008) Europace , vol.10 , pp. 1079-1084
    • De Piccoli, B.1    Rossillo, A.2    Zanella, C.3
  • 26
    • 0035139668 scopus 로고    scopus 로고
    • Identification of pulmonary vein stenosis after radiofrequency ablation for atrial fibrillation using MRI
    • Yang M, Akbari H, Reddy GP, et al,: Identification of pulmonary vein stenosis after radiofrequency ablation for atrial fibrillation using MRI. J Comp Assist Tomogr 2001; 25: 34-35.
    • (2001) J Comp Assist Tomogr , vol.25 , pp. 34-35
    • Yang, M.1    Akbari, H.2    Reddy, G.P.3
  • 27
    • 0034513778 scopus 로고    scopus 로고
    • Can we avoid pulmonary vein stenosis following ablation of atrial fibrillation?
    • Chen SA, Yu WC, Tai CT,: Can we avoid pulmonary vein stenosis following ablation of atrial fibrillation? J Interv Card Electrophysiol 2000; 4: 633-634.
    • (2000) J Interv Card Electrophysiol , vol.4 , pp. 633-634
    • Chen, S.A.1    Yu, W.C.2    Tai, C.T.3
  • 28
    • 33645749654 scopus 로고    scopus 로고
    • Radiation dose estimates from cardiac multislice computed tomography in daily practice: Impact of different scanning protocols on effective dose estimates
    • Hausleiter J, Meyer T, Hadamitzky M, et al,: Radiation dose estimates from cardiac multislice computed tomography in daily practice: Impact of different scanning protocols on effective dose estimates. Circulation 2006; 113: 1305-1310.
    • (2006) Circulation , vol.113 , pp. 1305-1310
    • Hausleiter, J.1    Meyer, T.2    Hadamitzky, M.3
  • 29
    • 64949151537 scopus 로고    scopus 로고
    • Recurrent CT, cumulative radiation exposure, and associated radiation-induced cancer risks from CT of adults
    • Sodickson A, Baeyens PF, Andriole KP, et al,: Recurrent CT, cumulative radiation exposure, and associated radiation-induced cancer risks from CT of adults. Radiology 2009; 251: 175-184.
    • (2009) Radiology , vol.251 , pp. 175-184
    • Sodickson, A.1    Baeyens, P.F.2    Andriole, K.P.3
  • 30
    • 0036216936 scopus 로고    scopus 로고
    • Safety issues in magnetic resonance imaging
    • Chung SM,. Safety issues in magnetic resonance imaging. J Neuroopthalmol 2002; 22: 35-39.
    • (2002) J Neuroopthalmol , vol.22 , pp. 35-39
    • Chung, S.M.1
  • 31
    • 33751029003 scopus 로고    scopus 로고
    • Cardiovascular imaging in the management of atrial fibrillation
    • Wazni OM, Tsao HM, Chen SA, et al,: Cardiovascular imaging in the management of atrial fibrillation. J Am Coll Cardiol 2006; 48: 2077-2084.
    • (2006) J Am Coll Cardiol , vol.48 , pp. 2077-2084
    • Wazni, O.M.1    Tsao, H.M.2    Chen, S.A.3
  • 32
    • 0029398988 scopus 로고
    • Evaluation of pulmonary vein stenosis by transesophageal echocardiography
    • Obeid AI, Carlson RJ,: Evaluation of pulmonary vein stenosis by transesophageal echocardiography. J Am Soc Echocardiogr 1995; 8: 888-896.
    • (1995) J Am Soc Echocardiogr , vol.8 , pp. 888-896
    • Obeid, A.I.1    Carlson, R.J.2
  • 33
    • 0036852209 scopus 로고    scopus 로고
    • Intracardiac Doppler echocardiographic quantification of pulmonary vein flow velocity: An effective technique for monitoring pulmonary vein ostia narrowing during focal atrial fibrillation ablation
    • Ren JF, Marchlinski FE, Callans DJ, et al,: Intracardiac Doppler echocardiographic quantification of pulmonary vein flow velocity: An effective technique for monitoring pulmonary vein ostia narrowing during focal atrial fibrillation ablation. J Cardiovasc Electrophysiol 2002; 13: 1076-1081.
    • (2002) J Cardiovasc Electrophysiol , vol.13 , pp. 1076-1081
    • Ren, J.F.1    Marchlinski, F.E.2    Callans, D.J.3
  • 34
    • 0347063910 scopus 로고    scopus 로고
    • A comparison of pulmonary vein ostial anatomy by computerized tomography, echocardiography, and venography in patients with atrial fibrillation having radiofrequency catheter ablation
    • Wood MA, Wittkamp M, Henry D, et al,: A comparison of pulmonary vein ostial anatomy by computerized tomography, echocardiography, and venography in patients with atrial fibrillation having radiofrequency catheter ablation. Am J Cardiol 2004; 93: 49-53.
    • (2004) Am J Cardiol , vol.93 , pp. 49-53
    • Wood, M.A.1    Wittkamp, M.2    Henry, D.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.