메뉴 건너뛰기




Volumn 4, Issue , 2010, Pages 156-161

Patient-specific unicompartmental knee resurfacing arthroplasty: Use of a novel interference lock to reduce tibial insert micromotion and backside wear

Author keywords

Knee; Micromotion; Patient specific; Polyethylene wear; Unicompartment

Indexed keywords

KNEE; MICROMOTION; PATIENT-SPECIFIC; POLYETHYLENE WEAR; UNICOMPARTMENT;

EID: 78249234732     PISSN: None     EISSN: 18741207     Source Type: Journal    
DOI: 10.2174/1874120701004010156     Document Type: Article
Times cited : (1)

References (10)
  • 1
    • 0032201263 scopus 로고    scopus 로고
    • Modular tibial insert micromotion
    • Nov
    • N.L. Parks, G.A. Engh, L.D. Topoleski, and J. Emparado, Modular tibial insert micromotion, CORR, vol. 356, pp. 10-15, Nov. 1998.
    • (1998) CORR , vol.356 , pp. 10-15
    • Parks, N.L.1    Engh, G.A.2    Topoleski, L.D.3    Emparado, J.4
  • 2
    • 0031457130 scopus 로고    scopus 로고
    • Tibial insert undersurface as a contributing source of polyethylene wear debris
    • Dec
    • R.C. Wasielewski, "Tibial insert undersurface as a contributing source of polyethylene wear debris," CORR, vol. 345, pp 53-59, Dec. 1997.
    • (1997) CORR , vol.345 , pp. 53-59
    • Wasielewski, R.C.1
  • 3
    • 13444249465 scopus 로고    scopus 로고
    • Backside wear of polyethylene tibial inserts: Mechanisms and magnitude of material loss
    • Feb
    • M.A. Conditt, M.T. Thompson, M.M. Usrey, S.K. Ismaily, and P.C. Noble, "Backside wear of polyethylene tibial inserts: mechanisms and magnitude of material loss," J. Bone Joint Surg. Am., vol. 87, pp. 326-331, Feb. 2005.
    • (2005) J. Bone Joint Surg. Am , vol.87 , pp. 326-331
    • Conditt, M.A.1    Thompson, M.T.2    Usrey, M.M.3    Ismaily, S.K.4    Noble, P.C.5
  • 4
    • 8644226074 scopus 로고    scopus 로고
    • Factors influencing wear and osteolysis in press-fit condylar modular total knee replacements
    • Nov
    • T.K. Fehring, J.A. Murphy, T.D. Hayes, D.W. Roberts, and D.L. Pomeroy, W.L. Griffin, "Factors influencing wear and osteolysis in press-fit condylar modular total knee replacements," CORR, vol. 428, pp. 40-50, Nov. 2004.
    • (2004) CORR , vol.4 , pp. 40-50
    • Fehring, T.K.1    Murphy, J.A.2    Hayes, D.H.3    Roberts, D.W.4    Pomeroy, D.L.5    Griffin, W.L.6
  • 5
    • 33846889008 scopus 로고    scopus 로고
    • Backside wear in modern total knee designs
    • Feb
    • P. Jayabalan, B.D. Furman, J.M. Cottrel, and T.M. Wright, "Backside wear in modern total knee designs," HSS J, vol. 3, pp. 30-34, Feb. 2007.
    • (2007) HSS J , vol.3 , pp. 30-34
    • Jayabalan, P.1    Furman, B.D.2    Cottrel, J.M.3    Wright, T.M.4
  • 6
    • 77951978186 scopus 로고    scopus 로고
    • Material and surface factors influencing backside fretting wear in total knee replacement tibial components
    • May
    • F. Billi, S.N. Sangiorgio, S. Aust, and E. Ebramzadeh, "Material and surface factors influencing backside fretting wear in total knee replacement tibial components," J. Biomech., vol. 43, pp. 1310-1315, May 2010.
    • (2010) J. Biomech , vol.43 , pp. 1310-1315
    • Billi, F.1    Sangiorgio, S.N.2    Aust, S.3    Ebramzadeh, E.4
  • 10
    • 2442490781 scopus 로고    scopus 로고
    • Backside wear of modular ultra-high molecular weight polyethylene tibial inserts
    • May
    • M.A. Conditt, S.K. Ismaily, J.W. Alexander, and P.C. Noble "Backside wear of modular ultra-high molecular weight polyethylene tibial inserts," J. Bone Joint Surg. Am., vol. 86-A, pp. 1031-7, May 2004.
    • (2004) J. Bone Joint Surg. Am , vol.86 A , pp. 1031-1037
    • Conditt, M.A.1    Ismaily, S.K.2    Alexander, J.W.3    Noble, P.C.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.