Volumn 43, Issue 7, 2010, Pages 1310-1315

Material and surface factors influencing backside fretting wear in total knee replacement tibial components

Author keywords

Cobalt alloy; Fretting; Knee replacement; Micromotion; Polyethylene; Surface roughness; Titanium alloy

Indexed keywords

FRETTING WEAR; KNEE REPLACEMENT; METAL ALLOYS; METAL SURFACES; MICROMOTION; PIN ON DISC; POLYETHYLENE WEAR; TIBIAL COMPONENT; TIBIAL TRAY; TOTAL KNEE REPLACEMENT; WEAR DEBRIS;

EID: 77951978186     PISSN: 00219290     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.jbiomech.2010.01.015     Document Type: Article
Times cited : (31)

References (24)
  • 2
    • 0034767304 scopus 로고    scopus 로고
    • Factors affecting the wear of irradiated UHMWPE
    • Burroughs B.R., Blanchet T.A. Factors affecting the wear of irradiated UHMWPE. Tribology Transactions 2001, 44:215-223.
    • (2001) Tribology Transactions , vol.44 , pp. 215-223
    • Burroughs, B.R.1    Blanchet, T.A.2
  • 10
    • 34247862235 scopus 로고    scopus 로고
    • Backside damage corresponding to articular damage in retrieved tibial polyethylene inserts
    • Harman M.K., Banks S.A., Hodge W.A. Backside damage corresponding to articular damage in retrieved tibial polyethylene inserts. h 2007, 458:137-144.
    • (2007) h , vol.458 , pp. 137-144
    • Harman, M.K.1    Banks, S.A.2    Hodge, W.A.3
  • 11
    • 0035482037 scopus 로고    scopus 로고
    • The effect of displacement control input parameters on tibiofemoral prosthetic knee wear
    • Johnson T.S., Laurent M.P., Yao J.Q., Gilbertson L.N. The effect of displacement control input parameters on tibiofemoral prosthetic knee wear. Wear 2001, 250:222-226.
    • (2001) Wear , vol.250 , pp. 222-226
    • Johnson, T.S.1    Laurent, M.P.2    Yao, J.Q.3    Gilbertson, L.N.4
  • 14
    • 0033647807 scopus 로고    scopus 로고
    • Wear of ultra-high molecular weight polyethylene (UHMWPE) in total knee prostheses: a review of key influences
    • McGloughlin T.M., Kavanagh A.G. Wear of ultra-high molecular weight polyethylene (UHMWPE) in total knee prostheses: a review of key influences. Proceedings of the Institute of Mechanical Engineers H 2000, 214:349-359.
    • (2000) Proceedings of the Institute of Mechanical Engineers H , vol.214 , pp. 349-359
    • McGloughlin, T.M.1    Kavanagh, A.G.2
  • 22
    • 0345735675 scopus 로고    scopus 로고
    • Contact stresses and fatigue life in a knee prosthesis: comparison between in vitro measurements and computational simulations
    • Villa T., Migliavacca F., Gastaldi D., Colombo M., Pietrabissa R. Contact stresses and fatigue life in a knee prosthesis: comparison between in vitro measurements and computational simulations. Journal of Biomechanics 2004, 37:45-53.
    • (2004) Journal of Biomechanics , vol.37 , pp. 45-53
    • Villa, T.1    Migliavacca, F.2    Gastaldi, D.3    Colombo, M.4    Pietrabissa, R.5
  • 23
    • 0035280295 scopus 로고    scopus 로고
    • A unified theory of wear for ultra-high molecular weight polyethylene in multi-directional sliding
    • Wang A. A unified theory of wear for ultra-high molecular weight polyethylene in multi-directional sliding. Wear 2001, 248:38-47.
    • (2001) Wear , vol.248 , pp. 38-47
    • Wang, A.1