메뉴 건너뛰기




Volumn 22, Issue 10, 2010, Pages 862-867

Comparison of Helical and Average Computed Tomography for Stereotactic Body Radiation Treatment Planning and Normal Tissue Contouring in Lung Cancer

Author keywords

Average computed tomography; Four dimensional computed tomography; Lung cancer; Organs at risk; Stereotactic body radiation therapy

Indexed keywords

ARTICLE; BRONCHUS; CANCER STAGING; CLINICAL ARTICLE; COMPUTER ASSISTED TOMOGRAPHY; DOSIMETRY; ESOPHAGUS; HEART; HUMAN; LUNG NON SMALL CELL CANCER; PRIORITY JOURNAL; RISK FACTOR; SPINAL CORD; STEREOTACTIC BODY RADIATION THERAPY; TRACHEA; TREATMENT PLANNING;

EID: 78149495739     PISSN: 09366555     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.clon.2010.08.010     Document Type: Article
Times cited : (22)

References (22)
  • 2
    • 0842327786 scopus 로고    scopus 로고
    • Artifacts in computed tomography scanning of moving objects
    • Chen G.T., Kung J.H., Beaudette K.P. Artifacts in computed tomography scanning of moving objects. Semin Radiat Oncol 2004, 14:19-26.
    • (2004) Semin Radiat Oncol , vol.14 , pp. 19-26
    • Chen, G.T.1    Kung, J.H.2    Beaudette, K.P.3
  • 4
    • 0034654424 scopus 로고    scopus 로고
    • Impact of respiratory movement on the computed tomographic images of small lung tumors in three-dimensional (3D) radiotherapy
    • Shimizu S., Shirato H., Kagei K., et al. Impact of respiratory movement on the computed tomographic images of small lung tumors in three-dimensional (3D) radiotherapy. Int J Radiat Oncol Biol Phys 2000, 46:1127-1133.
    • (2000) Int J Radiat Oncol Biol Phys , vol.46 , pp. 1127-1133
    • Shimizu, S.1    Shirato, H.2    Kagei, K.3
  • 5
    • 37549062637 scopus 로고    scopus 로고
    • Dosimetric impact of motion in free-breathing and gated lung radiotherapy: a 4D Monte Carlo study of intrafraction and interfraction effects
    • Seco J., Sharp G.C., Wu Z., Gierga D., Buettner F., Paganetti H. Dosimetric impact of motion in free-breathing and gated lung radiotherapy: a 4D Monte Carlo study of intrafraction and interfraction effects. Med Phys 2008, 35:356-366.
    • (2008) Med Phys , vol.35 , pp. 356-366
    • Seco, J.1    Sharp, G.C.2    Wu, Z.3    Gierga, D.4    Buettner, F.5    Paganetti, H.6
  • 6
    • 27144511689 scopus 로고    scopus 로고
    • A feasibility study for image guided radiotherapy using low dose, high speed, cone beam X-ray volumetric imaging
    • Sykes J.R., Amer A., Czajka J., Moore C.J. A feasibility study for image guided radiotherapy using low dose, high speed, cone beam X-ray volumetric imaging. Radiother Oncol 2005, 77:45-52.
    • (2005) Radiother Oncol , vol.77 , pp. 45-52
    • Sykes, J.R.1    Amer, A.2    Czajka, J.3    Moore, C.J.4
  • 7
    • 34247134028 scopus 로고    scopus 로고
    • Delineation of moving targets with slow MVCT scans: implications for adaptive non-gated lung tomotherapy
    • Smeenk C., Gaede S., Battista J.J. Delineation of moving targets with slow MVCT scans: implications for adaptive non-gated lung tomotherapy. Phys Med Biol 2007, 52:1119-1134.
    • (2007) Phys Med Biol , vol.52 , pp. 1119-1134
    • Smeenk, C.1    Gaede, S.2    Battista, J.J.3
  • 8
    • 33749438007 scopus 로고    scopus 로고
    • An "in silico" clinical trial comparing free breathing, slow and respiration correlated computed tomography in lung cancer patients
    • Bosmans G., Buijsen J., Dekker A., et al. An "in silico" clinical trial comparing free breathing, slow and respiration correlated computed tomography in lung cancer patients. Radiother Oncol 2006, 81:73-80.
    • (2006) Radiother Oncol , vol.81 , pp. 73-80
    • Bosmans, G.1    Buijsen, J.2    Dekker, A.3
  • 10
    • 4744343520 scopus 로고    scopus 로고
    • Measurement of lung tumor motion using respiration-correlated CT
    • Mageras G.S., Pevsner A., Yorke E.D., et al. Measurement of lung tumor motion using respiration-correlated CT. Int J Radiat Oncol Biol Phys 2004, 60:933-941.
    • (2004) Int J Radiat Oncol Biol Phys , vol.60 , pp. 933-941
    • Mageras, G.S.1    Pevsner, A.2    Yorke, E.D.3
  • 11
    • 41849136081 scopus 로고    scopus 로고
    • An evaluation of planning techniques for stereotactic body radiation therapy in lung tumors
    • Wu J., Li H., Shekhar R., Suntharalingam M., D'Souza W. An evaluation of planning techniques for stereotactic body radiation therapy in lung tumors. Radiother Oncol 2008, 87:35-43.
    • (2008) Radiother Oncol , vol.87 , pp. 35-43
    • Wu, J.1    Li, H.2    Shekhar, R.3    Suntharalingam, M.4    D'Souza, W.5
  • 12
    • 36349030205 scopus 로고    scopus 로고
    • Quantification of incidental dose to potential clinical target volume (CTV) under different stereotactic body radiation therapy (SBRT) techniques for non-small cell lung cancer - tumor motion and using internal target volume (ITV) could improve dose distribution in CTV
    • Jin J.Y., Ajlouni M., Chen Q., Kong F.M., Ryu S., Movsas B. Quantification of incidental dose to potential clinical target volume (CTV) under different stereotactic body radiation therapy (SBRT) techniques for non-small cell lung cancer - tumor motion and using internal target volume (ITV) could improve dose distribution in CTV. Radiother Oncol 2007, 85:267-276.
    • (2007) Radiother Oncol , vol.85 , pp. 267-276
    • Jin, J.Y.1    Ajlouni, M.2    Chen, Q.3    Kong, F.M.4    Ryu, S.5    Movsas, B.6
  • 13
    • 34548274489 scopus 로고    scopus 로고
    • Quantitative assessment of four-dimensional computed tomography image acquisition quality
    • Starkschall G., Desai N., Balter P., et al. Quantitative assessment of four-dimensional computed tomography image acquisition quality. J Appl Clin Med Phys 2007, 8:2362.
    • (2007) J Appl Clin Med Phys , vol.8 , pp. 2362
    • Starkschall, G.1    Desai, N.2    Balter, P.3
  • 14
    • 34247630225 scopus 로고    scopus 로고
    • The impact of temporal inaccuracies on 4DCT image quality
    • Mutaf Y.D., Antolak J.A., Brinkmann D.H. The impact of temporal inaccuracies on 4DCT image quality. Med Phys 2007, 34:1615-1622.
    • (2007) Med Phys , vol.34 , pp. 1615-1622
    • Mutaf, Y.D.1    Antolak, J.A.2    Brinkmann, D.H.3
  • 15
    • 33845232182 scopus 로고    scopus 로고
    • Comparison of helical, maximum intensity projection (MIP), and averaged intensity (AI) 4D CT imaging for stereotactic body radiation therapy (SBRT) planning in lung cancer
    • Bradley J.D., Nofal A.N., El Naqa I.M., et al. Comparison of helical, maximum intensity projection (MIP), and averaged intensity (AI) 4D CT imaging for stereotactic body radiation therapy (SBRT) planning in lung cancer. Radiother Oncol 2006, 81:264-268.
    • (2006) Radiother Oncol , vol.81 , pp. 264-268
    • Bradley, J.D.1    Nofal, A.N.2    El Naqa, I.M.3
  • 19
    • 78149498615 scopus 로고    scopus 로고
    • Monte Carlo calculations of dose distribution in NSCLC patients planned for stereotactic body radiation therapy. Proceedings of 50th Annual AAPM Meeting, Houston, Texas, 27-31 July
    • Moiseenko V, Popescu IA, Liu M, et al. Monte Carlo calculations of dose distribution in NSCLC patients planned for stereotactic body radiation therapy. Proceedings of 50th Annual AAPM Meeting, Houston, Texas, 27-31 July 2008.
    • (2008)
    • Moiseenko, V.1    Popescu, I.A.2    Liu, M.3
  • 20
    • 38349073468 scopus 로고    scopus 로고
    • A study of tumor motion management in the conformal radiotherapy of lung cancer
    • Burnett S.S.C., Sixel K.E., Cheung P.C., Hoisak J.D.P. A study of tumor motion management in the conformal radiotherapy of lung cancer. Radiother Oncol 2008, 86:77-85.
    • (2008) Radiother Oncol , vol.86 , pp. 77-85
    • Burnett, S.S.C.1    Sixel, K.E.2    Cheung, P.C.3    Hoisak, J.D.P.4
  • 21
    • 33744804817 scopus 로고    scopus 로고
    • Estimation of the delivered patient dose in lung IMRT treatment based on deformable registration of 4D-CT data and Monte Carlo simulations
    • Flampouri S., Jiang S.B., Sharp G.C., Wolfgang J., Patel A.A., Choi N.C. Estimation of the delivered patient dose in lung IMRT treatment based on deformable registration of 4D-CT data and Monte Carlo simulations. Phys Med Biol 2006, 51:2763-2779.
    • (2006) Phys Med Biol , vol.51 , pp. 2763-2779
    • Flampouri, S.1    Jiang, S.B.2    Sharp, G.C.3    Wolfgang, J.4    Patel, A.A.5    Choi, N.C.6
  • 22
    • 52049095720 scopus 로고    scopus 로고
    • Lung 4D-IMRT treatment planning: an evaluation of three methods applied to four-dimensional data sets
    • Ehler E.D., Tome W.A. Lung 4D-IMRT treatment planning: an evaluation of three methods applied to four-dimensional data sets. Radiother Oncol 2008, 88:319-385.
    • (2008) Radiother Oncol , vol.88 , pp. 319-385
    • Ehler, E.D.1    Tome, W.A.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.