메뉴 건너뛰기




Volumn 8, Issue 3, 2007, Pages 1-20

Quantitative assessment of four-dimensional computed tomography image acquisition quality

Author keywords

4D imaging; Computed tomography; Image assessment; Organ motion

Indexed keywords


EID: 34548274489     PISSN: None     EISSN: 15269914     Source Type: Journal    
DOI: 10.1120/jacmp.v8i3.2362     Document Type: Article
Times cited : (20)

References (15)
  • 1
    • 1242338927 scopus 로고    scopus 로고
    • 4D-CT imaging of a volume influenced by respiratory motion on multi-slice CT
    • Pan T, Lee TY, Rietzel E, Chen GTY. 4D-CT imaging of a volume influenced by respiratory motion on multi-slice CT. Med Phys. 2004;31(2):333-340.
    • (2004) Med Phys , vol.31 , Issue.2 , pp. 333-340
    • Pan, T.1    Lee, T.Y.2    Rietzel, E.3    Chen, G.T.Y.4
  • 2
    • 0141559032 scopus 로고    scopus 로고
    • Helical cardiac cone beam reconstruction using retrospective ECG gating
    • Grass M, Manzke R, Nielsen T, et al. Helical cardiac cone beam reconstruction using retrospective ECG gating. Phys Med Biol. 2003;48(18):3069-3084.
    • (2003) Phys Med Biol , vol.48 , Issue.18 , pp. 3069-3084
    • Grass, M.1    Manzke, R.2    Nielsen, T.3
  • 3
    • 2942545968 scopus 로고    scopus 로고
    • Acquiring 4D thoracic CT scans using a multislice helical method
    • Keall PJ, Starkschall G, Shukla H, et al. Acquiring 4D thoracic CT scans using a multislice helical method. Phys Med Biol. 2004;49(10):2053-2067.
    • (2004) Phys Med Biol , vol.49 , Issue.10 , pp. 2053-2067
    • Keall, P.J.1    Starkschall, G.2    Shukla, H.3
  • 4
    • 85024981693 scopus 로고    scopus 로고
    • A novel phantom simulating irregular motion to enhance assessment of respiration-correlated radiation therapy procedures
    • Fitzpatrick MJ, Starkschall G, Balter P, et al. A novel phantom simulating irregular motion to enhance assessment of respiration-correlated radiation therapy procedures. J Appl Clin Med Phys. 2005;6(1):13-21.
    • (2005) J Appl Clin Med Phys , vol.6 , Issue.1 , pp. 13-21
    • Fitzpatrick, M.J.1    Starkschall, G.2    Balter, P.3
  • 5
    • 34548251303 scopus 로고    scopus 로고
    • Development of an independent audit device for remote verification of 4D radiotherapy [Abstract]
    • Shoales J, Followill D, Ibbott G, Balter P, Tolani N. Development of an independent audit device for remote verification of 4D radiotherapy [Abstract]. Med Phys. 2005;32(6):2138.
    • (2005) Med Phys , vol.32 , Issue.6 , pp. 2138
    • Shoales, J.1    Followill, D.2    Ibbott, G.3    Balter, P.4    Tolani, N.5
  • 6
    • 17844371743 scopus 로고    scopus 로고
    • Four-dimensional computed tomography: Image formation and clinical protocol
    • Rietzel E, Pan T, Chen GTY. Four-dimensional computed tomography: image formation and clinical protocol. Med Phys. 2005;32(4):874-889.
    • (2005) Med Phys , vol.32 , Issue.4 , pp. 874-889
    • Rietzel, E.1    Pan, T.2    Chen, G.T.Y.3
  • 7
    • 28644434542 scopus 로고    scopus 로고
    • Optimization of multi-slice helical respiration-correlated CT: The effects of table speed and rotation time
    • Wink NM, McNitt-Gray W, Solberg TD. Optimization of multi-slice helical respiration-correlated CT: the effects of table speed and rotation time. Phys Med Biol. 2005;50(23):5717-5729.
    • (2005) Phys Med Biol , vol.50 , Issue.23 , pp. 5717-5729
    • Wink, N.M.1    McNitt-Gray, W.2    Solberg, T.D.3
  • 8
    • 4744367365 scopus 로고    scopus 로고
    • Automated model-based organ delineation for radiotherapy planning in prostatic region
    • Pekar V, McNutt TR, Kaus MR. Automated model-based organ delineation for radiotherapy planning in prostatic region. Int J Radiat Oncol Biol Phys. 2004;60(3):973-980.
    • (2004) Int J Radiat Oncol Biol Phys , vol.60 , Issue.3 , pp. 973-980
    • Pekar, V.1    McNutt, T.R.2    Kaus, M.R.3
  • 9
    • 22544437829 scopus 로고    scopus 로고
    • Ragan D, Starkschall G, McNutt T, Kaus M, Guerrero T, Stevens CW. Semi-automated four-dimensional computed tomography segmentation using deformable models. Med Phys. 2905;32(7):2254-2261.
    • Ragan D, Starkschall G, McNutt T, Kaus M, Guerrero T, Stevens CW. Semi-automated four-dimensional computed tomography segmentation using deformable models. Med Phys. 2905;32(7):2254-2261.
  • 10
    • 33745645302 scopus 로고    scopus 로고
    • Radiation dose reduction in 4D computed tomography [Abstract]
    • Li T, Schreibmann E, Thomdyke B, Xing L. Radiation dose reduction in 4D computed tomography [Abstract]. Med Phys. 2005;32(6):2094.
    • (2005) Med Phys , vol.32 , Issue.6 , pp. 2094
    • Li, T.1    Schreibmann, E.2    Thomdyke, B.3    Xing, L.4
  • 12
    • 85024404123 scopus 로고    scopus 로고
    • The effect of a novel amplitude/phase binning algorithm on commercial 4DCT quality [Abstract]
    • Olsen JR, Parikh PJ, Lu W, et al. The effect of a novel amplitude/phase binning algorithm on commercial 4DCT quality [Abstract]. Int J Radiat Oncol Biol Phys. 2006;66(3 Suppl):S56-S57.
    • (2006) Int J Radiat Oncol Biol Phys , vol.66 , Issue.3 SUPPL.
    • Olsen, J.R.1    Parikh, P.J.2    Lu, W.3
  • 13
    • 0037422708 scopus 로고    scopus 로고
    • Acquiring a four-dimensional computed tomography dataset using an external respiratory signal
    • Vedam, SS, Keall PJ, Kini VR, Mostafavi H, Shukla HP, Mohan R. Acquiring a four-dimensional computed tomography dataset using an external respiratory signal. Phys Med Biol. 2003;48(1):45-62.
    • (2003) Phys Med Biol , vol.48 , Issue.1 , pp. 45-62
    • Vedam, S.S.1    Keall, P.J.2    Kini, V.R.3    Mostafavi, H.4    Shukla, H.P.5    Mohan, R.6
  • 14
    • 0037237809 scopus 로고    scopus 로고
    • Respiration-correlated spiral CT. a method of measuring respiratory-induced anatomic motion for radiation treatment planning
    • Ford EC, Mageras GS, Yorke E, Ling CC. Respiration-correlated spiral CT. a method of measuring respiratory-induced anatomic motion for radiation treatment planning. Med Phys. 2003;30(1):88-97.
    • (2003) Med Phys , vol.30 , Issue.1 , pp. 88-97
    • Ford, E.C.1    Mageras, G.S.2    Yorke, E.3    Ling, C.C.4
  • 15
    • 11244329184 scopus 로고    scopus 로고
    • The impact of tumor motion upon CT image integrity and target delineation
    • Gagne IM, Robinson DM. The impact of tumor motion upon CT image integrity and target delineation. Med Phys. 2004;31(12):3378-3392.
    • (2004) Med Phys , vol.31 , Issue.12 , pp. 3378-3392
    • Gagne, I.M.1    Robinson, D.M.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.