메뉴 건너뛰기




Volumn 28, Issue 12, 2010, Pages 1665-1670

Benefits of thin-shelled acetabular components for metal-on-metal hip resurfacing arthroplasty

Author keywords

bilateral; biomechanics; hip; metal on metal; resurfacing

Indexed keywords

ABDUCTION; ACETABULUM; ADULT; ARTICLE; BIOMECHANICS; CLINICAL ARTICLE; FEMALE; FEMUR; HIP ARTHROPLASTY; HUMAN; MALE; OUTCOME ASSESSMENT; PAIN ASSESSMENT; PRIORITY JOURNAL; RADIOGRAPHY; RANGE OF MOTION; AGED; HIP OSTEOARTHRITIS; HIP PROSTHESIS; METHODOLOGY; MIDDLE AGED; OBSERVER VARIATION; PROSTHESIS; TREATMENT OUTCOME;

EID: 78149485011     PISSN: 07360266     EISSN: 1554527X     Source Type: Journal    
DOI: 10.1002/jor.21176     Document Type: Article
Times cited : (10)

References (22)
  • 1
    • 0018186561 scopus 로고
    • Surface replacement of the hip joint
    • Tanaka S,. 1978. Surface replacement of the hip joint. Clin Orthop 134: 75 -79.
    • (1978) Clin Orthop , vol.134 , pp. 75-79
    • Tanaka, S.1
  • 2
    • 0018628510 scopus 로고
    • Histomorphological investigations of coxa femoral ends following double-cup arthroplasty according to Freeman
    • Cserhati MD, Oliveira LG, Jacob HA, et al. 1979. Histomorphological investigations of coxa femoral ends following double-cup arthroplasty according to Freeman. Arch Orthop Trauma Surg 94-4: 233 -240.
    • (1979) Arch Orthop Trauma Surg , vol.944 , pp. 233-240
    • Cserhati, M.D.1    Oliveira, L.G.2    Jacob, H.A.3
  • 3
    • 0018134433 scopus 로고
    • The Paltrinieri-Trentani hip joint resurface arthroplasty
    • Trentani C, Vaccarino F,. 1978. The Paltrinieri-Trentani hip joint resurface arthroplasty. Clin Orthop 134: 36 -40.
    • (1978) Clin Orthop , vol.134 , pp. 36-40
    • Trentani, C.1    Vaccarino, F.2
  • 4
    • 33746415222 scopus 로고    scopus 로고
    • The development of the Durom metal-on-metal hip resurfacing
    • Grigoris P, Roberts P, Panousis K,. 2006. The development of the Durom metal-on-metal hip resurfacing. Hip Int 16-2 (Suppl 4): 65 -72.
    • (2006) Hip Int , vol.162 , Issue.SUPPL. 4 , pp. 65-72
    • Grigoris, P.1    Roberts, P.2    Panousis, K.3
  • 5
    • 33845489113 scopus 로고    scopus 로고
    • Hip resurfacing arthroplasty
    • Amstutz H,. Hip resurfacing arthroplasty. J Am Acad Orthop Surg 2006. 14-8: 452 -453.
    • (2006) J Am Acad Orthop Surg , vol.148 , pp. 452-453
    • Amstutz, H.1
  • 6
    • 33646169136 scopus 로고    scopus 로고
    • The effect of the diameter of metal-on-metal bearings on systemic exposure to cobalt and chromium
    • Daniel J, Ziaee H, Salama A, et al. 2006. The effect of the diameter of metal-on-metal bearings on systemic exposure to cobalt and chromium. J Bone Joint Surg 88B-4: 443 -448.
    • (2006) J Bone Joint Surg , vol.884 , pp. 443-448
    • Daniel, J.1    Ziaee, H.2    Salama, A.3
  • 7
    • 33846818683 scopus 로고    scopus 로고
    • Results of metal-on-metal hybrid hip resurfacing for Crowe type i and II developmental dysplasia
    • Amstutz H, Antoniades J, Le Duff M,. 2007. Results of metal-on-metal hybrid hip resurfacing for Crowe type I and II developmental dysplasia. J Bone Joint Surg Am 89-2: 339 -346.
    • (2007) J Bone Joint Surg Am , vol.892 , pp. 339-346
    • Amstutz, H.1    Antoniades, J.2    Le Duff, M.3
  • 8
    • 33745677639 scopus 로고    scopus 로고
    • Resurfacing arthroplasty of the hip in osteopetrosis
    • Girard J, Lavigne M, Vendittoli P, et al. 2006. Resurfacing arthroplasty of the hip in osteopetrosis. J Bone Joint Surg Br 88-6: 818 -821.
    • (2006) J Bone Joint Surg Br , vol.886 , pp. 818-821
    • Girard, J.1    Lavigne, M.2    Vendittoli, P.3
  • 9
    • 31144462750 scopus 로고    scopus 로고
    • Removal of acetabular bone in resurfacing arthroplasty of the hip: A comparison with hybrid total hip arthroplasty
    • Loughead J, Starks I, Chesney D, et al. 2006. Removal of acetabular bone in resurfacing arthroplasty of the hip: a comparison with hybrid total hip arthroplasty. J Bone Joint Surg 88 B-1: 31 -34.
    • (2006) J Bone Joint Surg , vol.88 B , Issue.1 , pp. 31-34
    • Loughead, J.1    Starks, I.2    Chesney, D.3
  • 10
    • 41149099079 scopus 로고    scopus 로고
    • Birmingham hip resurfacing: Is acetabular bone conserved?
    • Moonot P, Singh P, Cronin M, et al. 2008. Birmingham hip resurfacing: Is acetabular bone conserved? J Bone Joint Surg Br 90-3: 319 -323.
    • (2008) J Bone Joint Surg Br , vol.903 , pp. 319-323
    • Moonot, P.1    Singh, P.2    Cronin, M.3
  • 11
    • 33846816830 scopus 로고    scopus 로고
    • Metal-on-metal hybrid surface arthroplasty-surgical technique
    • Amstutz H, Beaulé P, Dorey F, et al. 2006. Metal-on-metal hybrid surface arthroplasty-surgical technique. J Bone Joint Surg 88 A (Suppl 1 part 2): 234 -249.
    • (2006) J Bone Joint Surg , vol.88 A , Issue.SUPPL. 1 AND PART 2 , pp. 234-249
    • Amstutz, H.1    Beaulé, P.2    Dorey, F.3
  • 12
    • 0347594037 scopus 로고    scopus 로고
    • The biomechanical results of total hip resurfacing arthroplasty
    • Silva M, Lee K, Heisel C, et al. 2004. The biomechanical results of total hip resurfacing arthroplasty. J Bone Joint Surg 86-A: 40 -46.
    • (2004) J Bone Joint Surg , vol.86 , pp. 40-46
    • Silva, M.1    Lee, K.2    Heisel, C.3
  • 13
    • 49549093602 scopus 로고    scopus 로고
    • Eleven years of experience with metal-on-metal hybrid hip resurfacing: A review of 1000 conserve plus
    • Amstutz H, Le Duff M,. 2008. Eleven years of experience with metal-on-metal hybrid hip resurfacing: a review of 1000 conserve plus. J Arthroplasty 23-6 (Suppl 1): 36 -43.
    • (2008) J Arthroplasty , vol.236 , Issue.SUPPL. 1 , pp. 36-43
    • Amstutz, H.1    Le Duff, M.2
  • 14
    • 20844454380 scopus 로고    scopus 로고
    • Reducing the risk of dislocation after total hip arthroplasty: The effect of orientation of the acetabular component
    • Biedermann R, Tonin A, Krismer M, et al. 2005. Reducing the risk of dislocation after total hip arthroplasty: the effect of orientation of the acetabular component. J Bone Joint Surg Br 87-6: 762 -769.
    • (2005) J Bone Joint Surg Br , vol.876 , pp. 762-769
    • Biedermann, R.1    Tonin, A.2    Krismer, M.3
  • 15
    • 0025758756 scopus 로고
    • Proximal placement of the acetabular component in total hip arthroplasty
    • Russotti G, Harris W,. 1991. Proximal placement of the acetabular component in total hip arthroplasty. J Bone Joint Surg 73A-4: 587 -592.
    • (1991) J Bone Joint Surg , vol.734 , pp. 587-592
    • Russotti, G.1    Harris, W.2
  • 16
    • 0017047304 scopus 로고
    • Radiological demarcation of cemented sockets in total hip replacement
    • DeLee JG, Charnley J,. 1976. Radiological demarcation of cemented sockets in total hip replacement. Clin Orthop 121: 20 -32.
    • (1976) Clin Orthop , vol.121 , pp. 20-32
    • Delee, J.G.1    Charnley, J.2
  • 17
    • 0033813755 scopus 로고    scopus 로고
    • Use of a magnet to retrieve a broken scalpel blade
    • Prasad R, Amstutz HC, Sparling EA,. 2000. Use of a magnet to retrieve a broken scalpel blade. J Arthroplasty 15-6: 806 -808.
    • (2000) J Arthroplasty , vol.156 , pp. 806-808
    • Prasad, R.1    Amstutz, H.C.2    Sparling, E.A.3
  • 18
    • 33645219347 scopus 로고    scopus 로고
    • Metal-on-metal bearings surfaces: Materials, manufacture, design, optimization, and alternatives
    • Isaac G, Thompson J, Williams S, et al. 2006. Metal-on-metal bearings surfaces: materials, manufacture, design, optimization, and alternatives. Proc Inst Mech Eng [H] 220-2: 119 -133.
    • (2006) Proc Inst Mech Eng [H] , vol.2202 , pp. 119-133
    • Isaac, G.1    Thompson, J.2    Williams, S.3
  • 19
    • 33745646707 scopus 로고    scopus 로고
    • Biomechanical reconstruction of the hip: A randomised study comparing total hip resurfacing and total hip arthroplasty
    • Girard J, Lavigne M, Vendittoli P, et al. 2006. Biomechanical reconstruction of the hip: a randomised study comparing total hip resurfacing and total hip arthroplasty. J Bone Joint Surg Br 88-6: 721 -726.
    • (2006) J Bone Joint Surg Br , vol.886 , pp. 721-726
    • Girard, J.1    Lavigne, M.2    Vendittoli, P.3
  • 20
    • 0348223830 scopus 로고    scopus 로고
    • Metal-on-metal hybrid surface arthroplasty: Two to six year follow-up
    • Amstutz H, Beaulé P, Dorey F, et al. 2004. Metal-on-metal hybrid surface arthroplasty: two to six year follow-up. J Bone Joint Surg 86 A: 28 -39.
    • (2004) J Bone Joint Surg , vol.88 A , pp. 28-39
    • Amstutz, H.1    Beaulé, P.2    Dorey, F.3
  • 21
    • 0030627631 scopus 로고    scopus 로고
    • Analysis of fluid film lubrication in artificial hip joint replacements with surfaces of high elastic modulus
    • Jin ZM, Dowson D, Fisher J,. 1997. Analysis of fluid film lubrication in artificial hip joint replacements with surfaces of high elastic modulus. Proc Inst Mech Eng [H] 211-3: 247 -256.
    • (1997) Proc Inst Mech Eng [H] , vol.2113 , pp. 247-256
    • Jin, Z.M.1    Dowson, D.2    Fisher, J.3
  • 22
    • 52449102219 scopus 로고    scopus 로고
    • Effect of bearing size on the long-term wear, wear debris, and ion levels of large diameter metal-on-metal hip replacements-an in vitro study
    • Leslie I, Williams S, Brown C, et al. 2008. Effect of bearing size on the long-term wear, wear debris, and ion levels of large diameter metal-on-metal hip replacements-an in vitro study. J Biomed Mater Res B Appl Biomater 87: 163 -172.
    • (2008) J Biomed Mater Res B Appl Biomater , vol.87 , pp. 163-172
    • Leslie, I.1    Williams, S.2    Brown, C.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.