메뉴 건너뛰기




Volumn 29, Issue 5, 2010, Pages 542-553

Study of corrosion of combinations of titanium/Ti-6Al-4V implants and dental alloys

Author keywords

Dissolution of metal ions; Implant; Micro structure of titanium

Indexed keywords

ACID SOLUTIONS; FIXING METHODS; GRAIN SIZE; IMPLANT;

EID: 78149388700     PISSN: 02874547     EISSN: None     Source Type: Journal    
DOI: 10.4012/dmj.2010-005     Document Type: Article
Times cited : (19)

References (40)
  • 2
    • 0034151536 scopus 로고    scopus 로고
    • Passivity of fit and marginal opening in screw- or cement-retained implant fixed partial denture designs
    • Guichet DL, Caputo AA, Choi H, Sorensen JA. Passivity of fit and marginal opening in screw- or cement-retained implant fixed partial denture designs. Int J Oral Maxillofac Implants 2000; 15: 239-246.
    • (2000) Int J Oral Maxillofac Implants , vol.15 , pp. 239-246
    • Guichet, D.L.1    Caputo, A.A.2    Choi, H.3    Sorensen, J.A.4
  • 3
    • 15944423262 scopus 로고    scopus 로고
    • Static implant loading caused by as-cast metal and ceramicveneered superstructures
    • Karl M, Rosch M, Graef F, Taylor TD, Heckmann SM. Static implant loading caused by as-cast metal and ceramicveneered superstructures. J Prosthet Dent 2005; 93: 324-330.
    • (2005) J Prosthet Dent , vol.93 , pp. 324-330
    • Karl, M.1    Rosch, M.2    Graef, F.3    Taylor, T.D.4    Heckmann, S.M.5
  • 4
    • 33846344006 scopus 로고    scopus 로고
    • Fracture resistance of implant-supported screw- versus cement-retained porcelain fused to metal single crowns
    • Zarone F, Sorrentino R, Traini T, Lorio DD, Caputi S. Fracture resistance of implant-supported screw- versus cement-retained porcelain fused to metal single crowns: SEM fractographic analysis. Dent Mater 2007; 23: 296-301.
    • (2007) SEM Fractographic Analysis. Dent Mater , vol.23 , pp. 296-301
    • Zarone, F.1    Sorrentino, R.2    Traini, T.3    Lorio, D.D.4    Caputi, S.5
  • 5
    • 33947545112 scopus 로고    scopus 로고
    • In vitro effects of load cycling on metal-ceramic cement- and screw-retained implant restorations
    • Karl M, Graef F, Taylor TD, Heckmann SM. In vitro effects of load cycling on metal-ceramic cement- and screw-retained implant restorations. J Prosthet Dent 2007; 97: 137-140.
    • (2007) J Prosthet Dent , vol.97 , pp. 137-140
    • Karl, M.1    Graef, F.2    Taylor, T.D.3    Heckmann, S.M.4
  • 7
    • 0024723970 scopus 로고
    • Corrosion of dental copper, nickel, and gold alloys in artificial saliva and saline solutions
    • Johansson BI, Lemons JE, Hao SQ. Corrosion of dental copper, nickel, and gold alloys in artificial saliva and saline solutions. Dent Mater 1989; 5: 324-328.
    • (1989) Dent Mater , vol.5 , pp. 324-328
    • Johansson, B.I.1    Lemons, J.E.2    Hao, S.Q.3
  • 9
    • 0034910625 scopus 로고    scopus 로고
    • The corrosion resistance of pure titanium in organic acids
    • Koike M, Fujii H. The corrosion resistance of pure titanium in organic acids. Biomaterials 2001; 22: 2931-2936.
    • (2001) Biomaterials , vol.22 , pp. 2931-2936
    • Koike, M.1    Fujii, H.2
  • 10
    • 0038384453 scopus 로고    scopus 로고
    • Ion release from NiTi orthodontic wires in artificial saliva with various acidities
    • Huang HH, Chiu YH, Lee TH, Wu SC, Yang HW, Su KH, Hsu CC. Ion release from NiTi orthodontic wires in artificial saliva with various acidities. Biomaterials 2003; 24: 3585-3592.
    • (2003) Biomaterials , vol.24 , pp. 3585-3592
    • Huang, H.H.1    Chiu, Y.H.2    Lee, T.H.3    Wu, S.C.4    Yang, H.W.5    Su, K.H.6    Hsu, C.C.7
  • 11
    • 0004418238 scopus 로고
    • Released metallic ion from Ti, Ti-6Al-4V alloy and Ni-Ti alloy
    • Yoneyama T, Doi H, Hamanaka H. Released metallic ion from Ti, Ti-6Al-4V alloy and Ni-Ti alloy. Seitai Zairyo 1993; 11: 71-78.
    • (1993) Seitai Zairyo , vol.11 , pp. 71-78
    • Yoneyama, T.1    Doi, H.2    Hamanaka, H.3
  • 12
    • 2942604622 scopus 로고    scopus 로고
    • Comparison of metal concentrations in rat tibia tissues with various metallic implants
    • Okazaki Y, Gotoh E, Manabe T, Kobayashi K. Comparison of metal concentrations in rat tibia tissues with various metallic implants. Biomaterials 2004; 25: 5913-5920.
    • (2004) Biomaterials , vol.25 , pp. 5913-5920
    • Okazaki, Y.1    Gotoh, E.2    Manabe, T.3    Kobayashi, K.4
  • 13
    • 0028450707 scopus 로고
    • Study of corrosion between a titanium implant and dental alloys
    • Reclaru L, Meyer JM. Study of corrosion between a titanium implant and dental alloys. J Dent 1994; 22: 159-168.
    • (1994) J Dent , vol.22 , pp. 159-168
    • Reclaru, L.1    Meyer, J.M.2
  • 14
    • 0345962022 scopus 로고    scopus 로고
    • Corrosion mechanism of coupled dental alloys
    • Tanaka K. Corrosion mechanism of coupled dental alloys. Tohoku Univ Dent J 1996; 14: 119-138.
    • (1996) Tohoku Univ Dent J , vol.14 , pp. 119-138
    • Tanaka, K.1
  • 15
    • 78149378272 scopus 로고    scopus 로고
    • Galvanic corrosion of various dental alloys and centrifugally cast new titanium alloy couples
    • Nakada H, Okazaki Y, Saeki H, Kobayashi K, Tateishi T. Galvanic corrosion of various dental alloys and centrifugally cast new titanium alloy couples. Seitai Zairyo 1998; 16: 243-253.
    • (1998) Seitai Zairyo , vol.16 , pp. 243-253
    • Nakada, H.1    Okazaki, Y.2    Saeki, H.3    Kobayashi, K.4    Tateishi, T.5
  • 16
    • 0032083038 scopus 로고    scopus 로고
    • Evaluation of restorative and implant alloys galvanically coupled to titanium
    • Venugopalan R, Lucas LC. Evaluation of restorative and implant alloys galvanically coupled to titanium. Dent Mater 1998; 14: 165-172.
    • (1998) Dent Mater , vol.14 , pp. 165-172
    • Venugopalan, R.1    Lucas, L.C.2
  • 18
    • 78149394126 scopus 로고    scopus 로고
    • Electrochemical behavior of coupled dental implant alloys
    • Kitamura T, Yoshinari M, Oda Y. Electrochemical behavior of coupled dental implant alloys. Shikwa Gakuho 2002; 102: 665-675.
    • (2002) Shikwa Gakuho , vol.102 , pp. 665-675
    • Kitamura, T.1    Yoshinari, M.2    Oda, Y.3
  • 22
    • 0026922624 scopus 로고
    • Biodegradation of restorative metallic systems
    • Lucas LC, Lemons JE. Biodegradation of restorative metallic systems. Adv Dent Res 1992; 6: 32-37.
    • (1992) Adv Dent Res , vol.6 , pp. 32-37
    • Lucas, L.C.1    Lemons, J.E.2
  • 23
    • 0019396832 scopus 로고
    • Tarnish and corrosion behavior of dental gold alloys
    • Laub LW, Stanford JW. Tarnish and corrosion behavior of dental gold alloys. Gold Bull 1981; 14: 13-18
    • (1981) Gold Bull , vol.14 , pp. 13-18
    • Laub, L.W.1    Stanford, J.W.2
  • 24
    • 30844471935 scopus 로고    scopus 로고
    • The Japan Institute of Metals, 4th ed. Tokyo: Maruzen Co
    • The Japan Institute of Metals. Kinzoku data book. 4th ed. Tokyo: Maruzen Co; 2004. p. 519.
    • (2004) Kinzoku Data Book , pp. 519
  • 26
    • 78149391737 scopus 로고
    • 1st ed. Tokyo: The Nikkan Kogyo Shinbun
    • Kusamichi H. Application of titanium metal. 1st ed. Tokyo: The Nikkan Kogyo Shinbun; 1987. p. 218-223.
    • (1987) Application of Titanium Metal , pp. 218-223
    • Kusamichi, H.1
  • 27
    • 0033141622 scopus 로고    scopus 로고
    • Polymetallism and osseointegration in oral implantology: Pilot study on primate
    • Foti B, Tavitian P, Tosello A, Bonfil JJ, Franquin JC. Polymetallism and osseointegration in oral implantology: pilot study on primate. J Oral Rehabil 1999; 26: 495-502.
    • (1999) J Oral Rehabil , vol.26 , pp. 495-502
    • Foti, B.1    Tavitian, P.2    Tosello, A.3    Bonfil, J.J.4    Franquin, J.C.5
  • 28
    • 0033135435 scopus 로고    scopus 로고
    • Measurement and evaluation of galvanic corrosion between titanium/ Ti6Al4V implants and dental alloys by electrochemical techniques and auger spectrometry
    • Grosgogeat B, Reclaru L, Lissac M, Dalard F. Measurement and evaluation of galvanic corrosion between titanium/ Ti6Al4V implants and dental alloys by electrochemical techniques and auger spectrometry. Biomaterials 1999; 20: 933-941.
    • (1999) Biomaterials , vol.20 , pp. 933-941
    • Grosgogeat, B.1    Reclaru, L.2    Lissac, M.3    Dalard, F.4
  • 29
    • 78149370240 scopus 로고
    • Epidemiological survey of metal allergy and its relationship with oral metal restorations. Grant-in-Aid for Co-operative Research (A)
    • Inoue M. Epidemiological survey of metal allergy and its relationship with oral metal restorations. Grant-in-Aid for Co-operative Research (A). Research Project Number: 01304047 Final Research Report, 1992.
    • (1992) Research Project Number: 01304047 Final Research Report
    • Inoue, M.1
  • 30
    • 35748977958 scopus 로고    scopus 로고
    • Japan: Ministry of health, Labor and welfare
    • Dietary reference intakes for Japanese (2010), Japan: Ministry of health, Labor and welfare; 2009. p. 218-275.
    • (2010) Dietary Reference Intakes for Japanese , pp. 218-275
  • 31
    • 0032008208 scopus 로고    scopus 로고
    • Cytotoxicity evaluation of 43 metal salts using murine fibroblasts and osteoblasttic cells
    • Yamamoto A, Honda R, Sumita M. Cytotoxicity evaluation of 43 metal salts using murine fibroblasts and osteoblasttic cells. J Biomed Mater Res 1998; 39: 331-340.
    • (1998) J Biomed Mater Res , vol.39 , pp. 331-340
    • Yamamoto, A.1    Honda, R.2    Sumita, M.3
  • 32
    • 78149387846 scopus 로고
    • An Experimental Study of Ti-Ni binary alloy as the material for implant
    • Fujimoto K. An Experimental Study of Ti-Ni binary alloy as the material for implant. J Jpn Soc Oral Implant 1986; 7: 25-55.
    • (1986) J Jpn Soc Oral Implant , vol.7 , pp. 25-55
    • Fujimoto, K.1
  • 33
    • 78149382179 scopus 로고
    • Experimental study on corrosion behavior in total Joint prosthesis employing different metals
    • Roppongi S, Higo Y. Experimental study on corrosion behavior in total Joint prosthesis employing different metals. Seitai Zairyo 1995; 13: 5-13.
    • (1995) Seitai Zairyo , vol.13 , pp. 5-13
    • Roppongi, S.1    Higo, Y.2
  • 34
    • 0015683182 scopus 로고
    • Changes in nonosseous tissue adjacent to titanium implants
    • Meachim G, Williams DF. Changes in nonosseous tissue adjacent to titanium implants. J Biomed Mater Res 1973; 7: 555-572.
    • (1973) J Biomed Mater Res , vol.7 , pp. 555-572
    • Meachim, G.1    Williams, D.F.2
  • 35
    • 0001429912 scopus 로고    scopus 로고
    • First report of a titanium allergy
    • Schweitzer A. First report of a titanium allergy. Dermatosen 1997; 45: 190.
    • (1997) Dermatosen , vol.45 , pp. 190
    • Schweitzer, A.1
  • 37
    • 0035234463 scopus 로고    scopus 로고
    • A Case of allergic reaction to surgical metal clips inserted for postoperative boost irradiation in a patient undergoing breast-conserving therapy
    • Tamai K, Mitsumori M, Fujishiro S, Kokubo M, Ooya N, Nagata Y, Sasai K, Hiraoka M, Inamoto T. A Case of allergic reaction to surgical metal clips inserted for postoperative boost irradiation in a patient undergoing breast-conserving therapy. Breast Cancer 2001; 8: 90-92.
    • (2001) Breast Cancer , vol.8 , pp. 90-92
    • Tamai, K.1    Mitsumori, M.2    Fujishiro, S.3    Kokubo, M.4    Ooya, N.5    Nagata, Y.6    Sasai, K.7    Hiraoka, M.8    Inamoto, T.9
  • 39
    • 0031246610 scopus 로고    scopus 로고
    • Effect of friction on the corrosion resistance for implant alloys in physiological saline solution
    • Okazaki Y, Kyo K, Ito Y, Tateishi T. Effect of friction on the corrosion resistance for implant alloys in physiological saline solution. J Japan Inst Metals 1997; 61: 1122-1131.
    • (1997) J Japan Inst Metals , vol.61 , pp. 1122-1131
    • Okazaki, Y.1    Kyo, K.2    Ito, Y.3    Tateishi, T.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.