메뉴 건너뛰기




Volumn 20, Issue 10, 1999, Pages 933-941

Measurement and evaluation of galvanic corrosion between titanium/Ti6Al4V implants and dental alloys by electrochemical techniques and auger spectrometry

Author keywords

[No Author keywords available]

Indexed keywords

AUGER ELECTRON SPECTROSCOPY; CORROSION; DENTAL ALLOYS; ELECTRIC CURRENT MEASUREMENT; ELECTROCHEMISTRY; MECHANICAL VARIABLES MEASUREMENT; TITANIUM ALLOYS;

EID: 0033135435     PISSN: 01429612     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0142-9612(98)00248-8     Document Type: Article
Times cited : (134)

References (33)
  • 1
    • 0347155335 scopus 로고
    • Titanium. Process industries corrosion - The theory and practice
    • Schutz RW. Titanium. Process industries corrosion - The theory and practice. National Association of Corrosion Engineers. 1986:503-27.
    • (1986) National Association of Corrosion Engineers , pp. 503-527
    • Schutz, R.W.1
  • 2
    • 0000174683 scopus 로고
    • Corrosion of titanium and titanium alloys
    • Metals Park, Ohio: ASM International, Corrosion
    • Schutz RW, Thomas DE. Corrosion of titanium and titanium alloys. Metals Handbook, 9th Edn. Metals Park, Ohio: ASM International, 1978, vol. 13, Corrosion, 669-706.
    • (1978) Metals Handbook, 9th Edn. , vol.13 , pp. 669-706
    • Schutz, R.W.1    Thomas, D.E.2
  • 3
    • 0001064914 scopus 로고
    • Titanium for surgical implants
    • Hille GH. Titanium for surgical implants. J Mat 1966;1:373-83.
    • (1966) J Mat , vol.1 , pp. 373-383
    • Hille, G.H.1
  • 4
    • 0013550815 scopus 로고
    • Titanium: Properties
    • Michael BB, editor. Oxford: Pergamon Press
    • Rosenberg HW. Titanium: Properties. In: Michael BB, editor. Encyclopedia of Materials Science and Engineering, vol 7. Oxford: Pergamon Press, 1986:5109-10.
    • (1986) Encyclopedia of Materials Science and Engineering , vol.7 , pp. 5109-5110
    • Rosenberg, H.W.1
  • 5
    • 0013550816 scopus 로고
    • Titanium and its applications
    • Kyoto. 18-19 January
    • ITO Yoshimasa. Titanium and its applications. Proc. 2nd Int Symp on Titanium in Dentistry, Kyoto. 18-19 January 1992:27-9.
    • (1992) Proc. 2nd Int Symp on Titanium in Dentistry , pp. 27-29
  • 6
    • 0013556953 scopus 로고
    • Tissue reactions of titanium and its alloys. Titanium science and technology
    • Lütjering G, Zwicker U, Bunk W, editors. Munich, 10-14 September, Oberusel, Deutsche Gesellschaft für Metalkunde EV, 1985
    • Pesch HJ, Glueckert K, Tuemmler HP, Thull R. Tissue reactions of titanium and its alloys. Titanium science and technology. In: Lütjering G, Zwicker U, Bunk W, editors. Proc 5th Int Conf on Titanium, vol 2. Munich, 10-14 September 1984:1387-92, Oberusel, Deutsche Gesellschaft für Metalkunde EV, 1985.
    • (1984) Proc 5th Int Conf on Titanium , vol.2 , pp. 1387-1392
    • Pesch, H.J.1    Glueckert, K.2    Tuemmler, H.P.3    Thull, R.4
  • 7
    • 0017564248 scopus 로고
    • Osseointegrated implants in the treatment of the edentulous jaw. Experience from a 10-year period
    • and as a monograph from Almqvist & Wiksell International, Stockholm
    • Branemark PI, Hansson BO, Adell R, Breine U, Lindstrom J, Hallen O, Ohman A. Osseointegrated implants in the treatment of the edentulous jaw. Experience from a 10-year period. Scand J Plast Reconstr Surg 1977; 11 (Suppl. 16) (and as a monograph from Almqvist & Wiksell International, Stockholm).
    • (1977) Scand J Plast Reconstr Surg , vol.11 , Issue.SUPPL. 16
    • Branemark, P.I.1    Hansson, B.O.2    Adell, R.3    Breine, U.4    Lindstrom, J.5    Hallen, O.6    Ohman, A.7
  • 9
    • 0019663098 scopus 로고
    • A 15 year study of osseointegrated implants in the treatment of the edentulous jaw
    • Adell R, Lekholm U, Rocker B, Branemark PI. A 15 year study of osseointegrated implants in the treatment of the edentulous jaw. Int J Oral Surg 1981;6:387-416.
    • (1981) Int J Oral Surg , vol.6 , pp. 387-416
    • Adell, R.1    Lekholm, U.2    Rocker, B.3    Branemark, P.I.4
  • 10
    • 0022702345 scopus 로고
    • A clinical evaluation of fixed bridge restorations supported by the combination of teeth and osseointegrated titanium implants
    • Ericsson I, Lekholm U, Branemark PI, Lindhe J, Glantz PO, Nyman S. A clinical evaluation of fixed bridge restorations supported by the combination of teeth and osseointegrated titanium implants. J Clin Periodontol 1986;13:307-12.
    • (1986) J Clin Periodontol , vol.13 , pp. 307-312
    • Ericsson, I.1    Lekholm, U.2    Branemark, P.I.3    Lindhe, J.4    Glantz, P.O.5    Nyman, S.6
  • 11
    • 0001705753 scopus 로고
    • Corrosion-reistant alloys in chloride solution: Materials for surgical implants
    • London
    • Hoar TP, Mears DC. Corrosion-reistant alloys in chloride solution: Materials for surgical implants. Proc R Soc (London) 1966; SCRA294 (1439):486-510.
    • (1966) Proc R Soc , vol.SCRA294 , Issue.1439 , pp. 486-510
    • Hoar, T.P.1    Mears, D.C.2
  • 12
    • 0014580251 scopus 로고
    • Corrosion behaviour of surgical implant materials: I. Effects of sterilization
    • Revie RW, Greene. Corrosion behaviour of surgical implant materials: I. Effects of sterilization. Corros Sci 1969;9:755-62.
    • (1969) Corros Sci , vol.9 , pp. 755-762
    • Revie, R.W.1    Greene2
  • 13
    • 0014580953 scopus 로고
    • Corrosion behaviour of surgical implant materials: II. Effects of surface preparation
    • Revie RW, Greene. Corrosion behaviour of surgical implant materials: II. Effects of surface preparation. Corros Sci 1969;9: 763-70.
    • (1969) Corros Sci , vol.9 , pp. 763-770
    • Revie, R.W.1    Greene2
  • 14
    • 0014747184 scopus 로고
    • Polarization studies of surgical materials in Ringer's solution
    • Mueller HJ, Greener HE. Polarization studies of surgical materials in Ringer's solution. J Biomed Mater Res 1970;4:29-41.
    • (1970) J Biomed Mater Res , vol.4 , pp. 29-41
    • Mueller, H.J.1    Greener, H.E.2
  • 15
    • 0013531455 scopus 로고
    • Corrosion of titanium alloys in physiological solutions
    • New York: Plenumm press
    • Fraker AC, Ruff AW, Yeager MP. Corrosion of titanium alloys in physiological solutions. Proc 2nd Int Titanium Conf., New York: Plenumm press, 1973:2447-57.
    • (1973) Proc 2nd Int Titanium Conf. , pp. 2447-2457
    • Fraker, A.C.1    Ruff, A.W.2    Yeager, M.P.3
  • 16
    • 0018766972 scopus 로고
    • Corrosion resistance of titanium surgical implant alloys: A review
    • Syrett BC, Acharya A, editors. American Society for Testing Materials
    • Solar JR. Corrosion resistance of titanium surgical implant alloys: A review. In: Syrett BC, Acharya A, editors. Corrosion and Degradation of Implant Materials, ASTM STP 684. American Society for Testing Materials, 1979:259-73.
    • (1979) Corrosion and Degradation of Implant Materials, ASTM STP 684 , pp. 259-273
    • Solar, J.R.1
  • 17
    • 0018753213 scopus 로고
    • Titanium release from implants: A proposed mechanism
    • Syrett BC, Acharya A, editors. American Society for Testing Materials
    • Solar JR, Pollack SR, Korostoff E. Titanium release from implants: A proposed mechanism. In: Syrett BC, Acharya A, editors. Corrosion and Degradation of Implant Materials, ASTM STP 684. American Society for Testing Materials, 1979:161-72.
    • (1979) Corrosion and Degradation of Implant Materials, ASTM STP 684 , pp. 161-172
    • Solar, J.R.1    Pollack, S.R.2    Korostoff, E.3
  • 18
    • 0018449066 scopus 로고
    • In vitro corrosion testing of titanium surgical implant alloys: An approach to understanding titanium release from implants
    • Solar JR, Pollack SR, Korostoff E. In vitro corrosion testing of titanium surgical implant alloys: An approach to understanding titanium release from implants. J Biomed Mater Res 1979; 13:217-50.
    • (1979) J Biomed Mater Res , vol.13 , pp. 217-250
    • Solar, J.R.1    Pollack, S.R.2    Korostoff, E.3
  • 19
    • 0018739369 scopus 로고
    • Fundamental aspects of the corrosion of metallic implants
    • Syrett BC, Acharya A, editors. American Society for Testing Materials
    • Kruger J. Fundamental aspects of the corrosion of metallic implants In: Syrett BC, Acharya A, editors. Corrosion and Degradation of Implant Materials, STP 684. American Society for Testing Materials, 1979:107-27.
    • (1979) Corrosion and Degradation of Implant Materials, STP 684 , pp. 107-127
    • Kruger, J.1
  • 20
  • 22
    • 0028450707 scopus 로고
    • Study of corrosion between a titanium implant and dental alloys
    • Reclaru L, Meyer JM. Study of corrosion between a titanium implant and dental alloys. J Dent 1994;22:159-68.
    • (1994) J Dent , vol.22 , pp. 159-168
    • Reclaru, L.1    Meyer, J.M.2
  • 23
    • 75449149598 scopus 로고
    • Corrosion of gold and amalgam placed in contact with each other
    • Fusayama T, Katayori T, Nomoto S. Corrosion of gold and amalgam placed in contact with each other. J Dent Res 1963; 42:1183-97.
    • (1963) J Dent Res , vol.42 , pp. 1183-1197
    • Fusayama, T.1    Katayori, T.2    Nomoto, S.3
  • 24
    • 0001054275 scopus 로고
    • Influence of artificial salivas on the corrosion of dental alloys
    • abstr. No. 76
    • Meyer JM, Nally JN. Influence of artificial salivas on the corrosion of dental alloys. J Dent Res 1975;54:678 (abstr. No. 76).
    • (1975) J Dent Res , vol.54 , pp. 678
    • Meyer, J.M.1    Nally, J.N.2
  • 25
    • 84946282516 scopus 로고
    • Laboratory studies of galvanic corrosion of aluminium alloys
    • Baboian R, France Jr WD, Roew Lc, Rynewicz JF, editors. Philadelphia: American Society for Testing and Materials
    • Mansfeld F, Kenkel JV. Laboratory studies of galvanic corrosion of aluminium alloys. In: Baboian R, France Jr WD, Roew Lc, Rynewicz JF, editors. Galvanic and Pitting Corrosion - Field and Laboratory Studies, ASTM STP 576. Philadelphia: American Society for Testing and Materials, 1976:20-47.
    • (1976) Galvanic and Pitting Corrosion - Field and Laboratory Studies, ASTM STP 576 , pp. 20-47
    • Mansfeld, F.1    Kenkel, J.V.2
  • 26
    • 0004282914 scopus 로고
    • Instrumentation for corrosion studies
    • Technical Report, Rockwell International
    • Mansfeld F, Myers RL, Lauer G. Instrumentation for corrosion studies. Low Conductivity Media. 1973, Technical Report, Rockwell International.
    • (1973) Low Conductivity Media
    • Mansfeld, F.1    Myers, R.L.2    Lauer, G.3
  • 27
    • 85169128477 scopus 로고
    • Electrochemical techniques for predicting galvanic corrosion
    • Baboian R, France Jr WD, Roew Lc, Rynewicz JF, editors. Philadelphia: American Society for Testing and Materials
    • Baboian R. Electrochemical techniques for predicting galvanic corrosion. In: Baboian R, France Jr WD, Roew Lc, Rynewicz JF, editors. Galvanic and Pitting Corrosion - Field and Laboratory Studies, ASTM STP 576. Philadelphia: American Society for Testing and Materials, 1976:20-47.
    • (1976) Galvanic and Pitting Corrosion - Field and Laboratory Studies, ASTM STP 576 , pp. 20-47
    • Baboian, R.1
  • 28
    • 0000070650 scopus 로고
    • Uber die deutung von korrosionsvorgängen durch uberlagerung von elektrochemischen teillvorängen und über die potentialbildung an mischelektroden
    • Wagner C, Traud W. Uber die deutung von korrosionsvorgängen durch uberlagerung von elektrochemischen teillvorängen und über die potentialbildung an mischelektroden. Z Electrochem 1938;44:391-454.
    • (1938) Z Electrochem , vol.44 , pp. 391-454
    • Wagner, C.1    Traud, W.2
  • 30
    • 0016981816 scopus 로고
    • Adhésion des peintures sur le titane anodisé. Etude des films d'oxyde
    • Dalard F, Montella C, Sohm JC. Adhésion des peintures sur le titane anodisé. Etude des films d'oxyde. Surf Techn 1976;4:367-80.
    • (1976) Surf Techn , vol.4 , pp. 367-380
    • Dalard, F.1    Montella, C.2    Sohm, J.C.3
  • 31
    • 0020905617 scopus 로고
    • Surface preparation and corrosion of titanium alloys for surgical implants
    • Luckey HA, Fred Kubli Jr, editors. American Society for Testing and Materials
    • Fraker AC, Ruff WA, Sung P, Van Orden AC, Speck KM. Surface preparation and corrosion of titanium alloys for surgical implants. In: Luckey HA, Fred Kubli Jr, editors. ASTM STP 796. American Society for Testing and Materials, 1983:206-19.
    • (1983) ASTM STP 796 , pp. 206-219
    • Fraker, A.C.1    Ruff, W.A.2    Sung, P.3    Van Orden, A.C.4    Speck, K.M.5
  • 32
    • 0030175875 scopus 로고    scopus 로고
    • A preliminary investigation into microscopic depassivation of passive titanium implant materials in vitro
    • Souto RM, Burstein GT. A preliminary investigation into microscopic depassivation of passive titanium implant materials in vitro. J Mater Sci Mater Med 1996;7:337-43.
    • (1996) J Mater Sci Mater Med , vol.7 , pp. 337-343
    • Souto, R.M.1    Burstein, G.T.2
  • 33
    • 0024752457 scopus 로고
    • Technical note: Corrosion behavior of rapidly solidified Al-Ti base alloys in chloride environment
    • Mozhi TA, Jha SC, Ray R. Technical note: Corrosion behavior of rapidly solidified Al-Ti base alloys in chloride environment. Corr Sci 1989;4:811-3.
    • (1989) Corr Sci , vol.4 , pp. 811-813
    • Mozhi, T.A.1    Jha, S.C.2    Ray, R.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.