메뉴 건너뛰기




Volumn 69, Issue 4, 2010, Pages 156-163

Effects of blood and saliva contamination on shear bond strength of metal orthodontic brackets and evaluating certain methods for reversing the effect of contamination

Author keywords

Blood saliva contamination; Drying rinsing drying re etching surface treatments; Resin modified glass ionomer cement (RMGIC); Self etchant primer (SEP); Shear bond strength (SBS)

Indexed keywords


EID: 78149358051     PISSN: 13440241     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.odw.2010.06.001     Document Type: Article
Times cited : (16)

References (35)
  • 1
    • 0141956392 scopus 로고    scopus 로고
    • Effect of saliva on shear bond strength of an orthodontic adhesive used with moisture-insensitive and self-etching primers
    • Zeppieri I., Chung C., Mante F. Effect of saliva on shear bond strength of an orthodontic adhesive used with moisture-insensitive and self-etching primers. Am J Orthod Dentofacial Orthop 2003, 124(4):414-419.
    • (2003) Am J Orthod Dentofacial Orthop , vol.124 , Issue.4 , pp. 414-419
    • Zeppieri, I.1    Chung, C.2    Mante, F.3
  • 3
    • 0033290187 scopus 로고    scopus 로고
    • Effect of water, saliva and blood contamination on bonding of metal brackets with a 4-META/MMA/TBB resin to etched enamel
    • Itoh T., Fukushima T., Inoue Y., Arita S., Miyazaki K. Effect of water, saliva and blood contamination on bonding of metal brackets with a 4-META/MMA/TBB resin to etched enamel. Am J Dent 1999, 12(6):299.
    • (1999) Am J Dent , vol.12 , Issue.6 , pp. 299
    • Itoh, T.1    Fukushima, T.2    Inoue, Y.3    Arita, S.4    Miyazaki, K.5
  • 4
    • 78149359456 scopus 로고    scopus 로고
    • The effect of surface contamination on shear bond strength of self etching bonding systems. Master's Thesis. Iowa City, Iowa: The University of Iowa;
    • Oonsombat C. The effect of surface contamination on shear bond strength of self etching bonding systems. Master's Thesis. Iowa City, Iowa: The University of Iowa; 2002.
    • (2002)
    • Oonsombat, C.1
  • 5
    • 0037831048 scopus 로고    scopus 로고
    • Effect of water and saliva contamination on shear bond strength of brackets bonded with conventional, hydrophilic, and self-etching primers* 1
    • Cacciafesta V., Sfondrini M., De Angelis M., Scribante A., Klersy C. Effect of water and saliva contamination on shear bond strength of brackets bonded with conventional, hydrophilic, and self-etching primers* 1. Am J Orthod Dentofacial Orthop 2003, 123(6):633-640.
    • (2003) Am J Orthod Dentofacial Orthop , vol.123 , Issue.6 , pp. 633-640
    • Cacciafesta, V.1    Sfondrini, M.2    De Angelis, M.3    Scribante, A.4    Klersy, C.5
  • 6
    • 15944369718 scopus 로고    scopus 로고
    • Effect of moisture contamination on bracket bond strength of hydrophilic bonding materials
    • Crane M., Smart C., Moon H. Effect of moisture contamination on bracket bond strength of hydrophilic bonding materials. J Dent Res 2000, 79:548.
    • (2000) J Dent Res , vol.79 , pp. 548
    • Crane, M.1    Smart, C.2    Moon, H.3
  • 7
    • 0036719297 scopus 로고    scopus 로고
    • Bond strength comparison of moisture-insensitive primers
    • Schaneveldt S., Foley T. Bond strength comparison of moisture-insensitive primers. Am J Orthod Dentofacial Orthop 2002, 122(3):267-273.
    • (2002) Am J Orthod Dentofacial Orthop , vol.122 , Issue.3 , pp. 267-273
    • Schaneveldt, S.1    Foley, T.2
  • 8
    • 36949017073 scopus 로고    scopus 로고
    • An in vitro comparative assessment of different enamel contaminants during bracket bonding
    • Faltermeier A., Behr M., Rosentritt M., Reicheneder C., Mussig D. An in vitro comparative assessment of different enamel contaminants during bracket bonding. Eur J Orthod 2007, 29(6):559.
    • (2007) Eur J Orthod , vol.29 , Issue.6 , pp. 559
    • Faltermeier, A.1    Behr, M.2    Rosentritt, M.3    Reicheneder, C.4    Mussig, D.5
  • 9
    • 3042626796 scopus 로고    scopus 로고
    • Efficacy of using self-etching primer with a 4-META/MMA-TBB resin cement in bonding orthodontic brackets to human enamel and effect of saliva contamination on shear bond strength
    • Sirirungrojying S., Saito K., Hayakawa T., Kasai K. Efficacy of using self-etching primer with a 4-META/MMA-TBB resin cement in bonding orthodontic brackets to human enamel and effect of saliva contamination on shear bond strength. Angle Orthod 2004, 74(2):251-258.
    • (2004) Angle Orthod , vol.74 , Issue.2 , pp. 251-258
    • Sirirungrojying, S.1    Saito, K.2    Hayakawa, T.3    Kasai, K.4
  • 10
    • 10144246592 scopus 로고    scopus 로고
    • Bonding durability between orthodontic brackets and human enamel treated with megabond self-etching primer using 4-META/MMA-TBB resin cement
    • Sirirungrojying S., Hayakawa T., Saito K., Meguro D., Nemoto K., Kasai K. Bonding durability between orthodontic brackets and human enamel treated with megabond self-etching primer using 4-META/MMA-TBB resin cement. Dent Mater J 2004, 23(3):251-257.
    • (2004) Dent Mater J , vol.23 , Issue.3 , pp. 251-257
    • Sirirungrojying, S.1    Hayakawa, T.2    Saito, K.3    Meguro, D.4    Nemoto, K.5    Kasai, K.6
  • 11
    • 52949091177 scopus 로고    scopus 로고
    • Effect of re-etching after blood contamination on the shear bond strength of light-cured resin-modified glass ionomer cement
    • Shi Y., Xiao T., Ping Y., Song J., Shan L. Effect of re-etching after blood contamination on the shear bond strength of light-cured resin-modified glass ionomer cement. Zhongguo Zuzhi Gongcheng Yanjiu yu Linchuang Kangfu 2008, 12(27):5279-5282.
    • (2008) Zhongguo Zuzhi Gongcheng Yanjiu yu Linchuang Kangfu , vol.12 , Issue.27 , pp. 5279-5282
    • Shi, Y.1    Xiao, T.2    Ping, Y.3    Song, J.4    Shan, L.5
  • 12
    • 0038282590 scopus 로고    scopus 로고
    • The effect of blood contamination on the shear bond strength of orthodontic brackets with the use of a new self-etch primer
    • Oonsombat C., Bishara S., Ajlouni R. The effect of blood contamination on the shear bond strength of orthodontic brackets with the use of a new self-etch primer. Am J Orthod Dentofacial Orthop 2003, 123(5):547-550.
    • (2003) Am J Orthod Dentofacial Orthop , vol.123 , Issue.5 , pp. 547-550
    • Oonsombat, C.1    Bishara, S.2    Ajlouni, R.3
  • 13
    • 1542327254 scopus 로고    scopus 로고
    • Effect of blood contamination on shear bond strength of brackets bonded with conventional and self-etching primers
    • Sfondrini M., Cacciafesta V., Scribante A., De Angelis M., Klersy C. Effect of blood contamination on shear bond strength of brackets bonded with conventional and self-etching primers. Am J Orthod Dentofacial Orthop 2004, 125(3):357-360.
    • (2004) Am J Orthod Dentofacial Orthop , vol.125 , Issue.3 , pp. 357-360
    • Sfondrini, M.1    Cacciafesta, V.2    Scribante, A.3    De Angelis, M.4    Klersy, C.5
  • 14
    • 10044292828 scopus 로고    scopus 로고
    • Effect of blood contamination on shear bond strength of brackets bonded with a self-etching primer combined with a resin-modified glass ionomer
    • Cacciafesta V., Francesca Sfondrini M., Scribante A., De Angelis M., Klersy C. Effect of blood contamination on shear bond strength of brackets bonded with a self-etching primer combined with a resin-modified glass ionomer. Am J Orthod Dentofacial Orthop 2004, 126(6):703-708.
    • (2004) Am J Orthod Dentofacial Orthop , vol.126 , Issue.6 , pp. 703-708
    • Cacciafesta, V.1    Francesca Sfondrini, M.2    Scribante, A.3    De Angelis, M.4    Klersy, C.5
  • 15
    • 33846602855 scopus 로고    scopus 로고
    • Effect of blood and saliva contamination on shear bond strength of brackets bonded with 4 adhesives
    • Öztoprak M., Isik F., Say nsu K., Arun T., Aydemir B. Effect of blood and saliva contamination on shear bond strength of brackets bonded with 4 adhesives. Am J Orthod Dentofacial Orthop 2007, 131(2):238-242.
    • (2007) Am J Orthod Dentofacial Orthop , vol.131 , Issue.2 , pp. 238-242
    • Öztoprak, M.1    Isik, F.2    Say nsu, K.3    Arun, T.4    Aydemir, B.5
  • 17
    • 0041419904 scopus 로고    scopus 로고
    • Evaluation of cetylpyridinium chloride for infection control in storage solution
    • Ziskind D., Gleitman J., Rotstein I., Friedman M. Evaluation of cetylpyridinium chloride for infection control in storage solution. J Oral Rehabil 2003, 30(5):477-481.
    • (2003) J Oral Rehabil , vol.30 , Issue.5 , pp. 477-481
    • Ziskind, D.1    Gleitman, J.2    Rotstein, I.3    Friedman, M.4
  • 18
    • 10044238829 scopus 로고    scopus 로고
    • Effect of primer precuring on the shear bond strength of orthodontic brackets
    • December
    • Oesterle L.J., Shellhart W.C., Fisher A. Effect of primer precuring on the shear bond strength of orthodontic brackets. Am J Orthod Dentofacial Orthop 2004, 126(December (6)):699-702.
    • (2004) Am J Orthod Dentofacial Orthop , vol.126 , Issue.6 , pp. 699-702
    • Oesterle, L.J.1    Shellhart, W.C.2    Fisher, A.3
  • 20
    • 0037669775 scopus 로고
    • A review of direct orthodontic bonding
    • Reynolds I. A review of direct orthodontic bonding. Br J Orthod 1975, 2(2):171-178.
    • (1975) Br J Orthod , vol.2 , Issue.2 , pp. 171-178
    • Reynolds, I.1
  • 21
    • 0141887447 scopus 로고    scopus 로고
    • Use of a self-etching primer in combination with a resin-modified glass ionomer: effect of water and saliva contamination on shear bond strength
    • Cacciafesta V., Sfondrini M., Baluga L., Scribante A., Klersy C. Use of a self-etching primer in combination with a resin-modified glass ionomer: effect of water and saliva contamination on shear bond strength. Am J Orthod Dentofacial Orthop 2003, 124(4):420-426.
    • (2003) Am J Orthod Dentofacial Orthop , vol.124 , Issue.4 , pp. 420-426
    • Cacciafesta, V.1    Sfondrini, M.2    Baluga, L.3    Scribante, A.4    Klersy, C.5
  • 22
    • 33644650177 scopus 로고    scopus 로고
    • Light curing the primer-beneficial when working in problem areas?
    • Sayinsu K., Isik F., Sezen S., Aydemir B. Light curing the primer-beneficial when working in problem areas?. Angle Orthod 2006, 76(2):310-313.
    • (2006) Angle Orthod , vol.76 , Issue.2 , pp. 310-313
    • Sayinsu, K.1    Isik, F.2    Sezen, S.3    Aydemir, B.4
  • 23
    • 33847394622 scopus 로고    scopus 로고
    • Effect of blood and saliva contamination on bond strength of brackets bonded with a protective liquid polish and a light-cured adhesive
    • Sayinsu K., Isik F., Sezen S., Aydemir B. Effect of blood and saliva contamination on bond strength of brackets bonded with a protective liquid polish and a light-cured adhesive. Am J Orthod Dentofacial Orthop 2007, 131(3):391-394.
    • (2007) Am J Orthod Dentofacial Orthop , vol.131 , Issue.3 , pp. 391-394
    • Sayinsu, K.1    Isik, F.2    Sezen, S.3    Aydemir, B.4
  • 24
    • 0037310804 scopus 로고    scopus 로고
    • Bond strength for orthodontic brackets contaminated by blood: composite versus resin-modified glass ionomer cements
    • Reddy L., Marker V., Ellis E. Bond strength for orthodontic brackets contaminated by blood: composite versus resin-modified glass ionomer cements. J Oral Maxillofac Surg 2003, 61(2):206-213.
    • (2003) J Oral Maxillofac Surg , vol.61 , Issue.2 , pp. 206-213
    • Reddy, L.1    Marker, V.2    Ellis, E.3
  • 25
    • 33644788603 scopus 로고    scopus 로고
    • Shear/peel bond strength of orthodontic attachments to moist and dry enamel
    • Nemeth B., Wiltshire W., Lavelle C. Shear/peel bond strength of orthodontic attachments to moist and dry enamel. Am J Orthod Dentofacial Orthop 2006, 129(3):396-401.
    • (2006) Am J Orthod Dentofacial Orthop , vol.129 , Issue.3 , pp. 396-401
    • Nemeth, B.1    Wiltshire, W.2    Lavelle, C.3
  • 26
    • 33646168545 scopus 로고    scopus 로고
    • An investigation into the use of a single component self-etching primer adhesive system for orthodontic bonding: a randomized controlled clinical trial
    • House K., Ireland A., Sherriff M. An investigation into the use of a single component self-etching primer adhesive system for orthodontic bonding: a randomized controlled clinical trial. J Orthod 2006, 33(1):38-44.
    • (2006) J Orthod , vol.33 , Issue.1 , pp. 38-44
    • House, K.1    Ireland, A.2    Sherriff, M.3
  • 27
    • 18844399112 scopus 로고    scopus 로고
    • Effect of self-etching primer and adhesive formulations on the shear bond strength of orthodontic brackets
    • Cehreli Z., Kecik D., Kocadereli I. Effect of self-etching primer and adhesive formulations on the shear bond strength of orthodontic brackets. Am J Orthod Dentofacial Orthop 2005, 127(5):573-579.
    • (2005) Am J Orthod Dentofacial Orthop , vol.127 , Issue.5 , pp. 573-579
    • Cehreli, Z.1    Kecik, D.2    Kocadereli, I.3
  • 28
    • 3843123305 scopus 로고    scopus 로고
    • Bond strength of a sealant to primary and permanent enamel: phosphoric acid versus self-etching adhesive
    • Peutzfeldt A., Nielsen L. Bond strength of a sealant to primary and permanent enamel: phosphoric acid versus self-etching adhesive. Pediatr Dent 2004, 26(3):240-244.
    • (2004) Pediatr Dent , vol.26 , Issue.3 , pp. 240-244
    • Peutzfeldt, A.1    Nielsen, L.2
  • 30
    • 33645466461 scopus 로고    scopus 로고
    • Self-etching primer and a non-rinse conditioner versus phosphoric acid: alternative methods for bonding brackets
    • Vicente A., Bravo L., Romero M. Self-etching primer and a non-rinse conditioner versus phosphoric acid: alternative methods for bonding brackets. Eur J Orthod 2006, 28(2):173-178.
    • (2006) Eur J Orthod , vol.28 , Issue.2 , pp. 173-178
    • Vicente, A.1    Bravo, L.2    Romero, M.3
  • 31
    • 42449088573 scopus 로고    scopus 로고
    • Treated enamel surface patterns associated with five orthodontic adhesive systems-surface morphology and shear bond strength
    • Shinya M., Shinya A., Lassila L., Gomi H., Varrela J., Vallittu K.P. Treated enamel surface patterns associated with five orthodontic adhesive systems-surface morphology and shear bond strength. Dent Mater J 2008, 27(1):1-6.
    • (2008) Dent Mater J , vol.27 , Issue.1 , pp. 1-6
    • Shinya, M.1    Shinya, A.2    Lassila, L.3    Gomi, H.4    Varrela, J.5    Vallittu, K.P.6
  • 32
    • 0024722777 scopus 로고
    • An evaluation of the bond strengths of four organosilane materials in response to thermal stress
    • September
    • Diaz-Arnold A.M., Aquilino S.A. An evaluation of the bond strengths of four organosilane materials in response to thermal stress. J Prosthet Dent 1989, 62(September (3)):257-260.
    • (1989) J Prosthet Dent , vol.62 , Issue.3 , pp. 257-260
    • Diaz-Arnold, A.M.1    Aquilino, S.A.2
  • 33
    • 0034131799 scopus 로고    scopus 로고
    • Effect of light-cure time on the initial shear bond strength of a glass-ionomer adhesive
    • February
    • Bishara S.E., VonWald L., Olsen M.E., Laffoon J.F., Jakobsen J.R. Effect of light-cure time on the initial shear bond strength of a glass-ionomer adhesive. Am J Orthod Dentofacial Orthop 2000, 117(February (2)):164-168.
    • (2000) Am J Orthod Dentofacial Orthop , vol.117 , Issue.2 , pp. 164-168
    • Bishara, S.E.1    VonWald, L.2    Olsen, M.E.3    Laffoon, J.F.4    Jakobsen, J.R.5
  • 34
    • 38349009099 scopus 로고    scopus 로고
    • Effect of acidulated phosphate fluoride and casein phosphopeptide-amorphous calcium phosphate application on shear bond strength of orthodontic brackets
    • January
    • Kecik D., Cehreli S.B., Sar C., Unver B. Effect of acidulated phosphate fluoride and casein phosphopeptide-amorphous calcium phosphate application on shear bond strength of orthodontic brackets. Angle Orthod 2008, 78(January (1)):129-133.
    • (2008) Angle Orthod , vol.78 , Issue.1 , pp. 129-133
    • Kecik, D.1    Cehreli, S.B.2    Sar, C.3    Unver, B.4
  • 35
    • 40149090381 scopus 로고    scopus 로고
    • Shear bond strength and FEM of a resin-modified glass ionomer cement-effects of tooth enamel shape and orthodontic bracket base configuration
    • Hioki M., Shin-Ya A., Nakahara R., Vallittu P., Nakasone Y. Shear bond strength and FEM of a resin-modified glass ionomer cement-effects of tooth enamel shape and orthodontic bracket base configuration. Dent Mater J 2007, 26(5):700-707.
    • (2007) Dent Mater J , vol.26 , Issue.5 , pp. 700-707
    • Hioki, M.1    Shin-Ya, A.2    Nakahara, R.3    Vallittu, P.4    Nakasone, Y.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.