메뉴 건너뛰기




Volumn 41, Issue 12, 2010, Pages 1312-1316

Predictive factors for cutting-out in femoral intramedullary nailing

Author keywords

Cut out; Cutting out; Extracapsular; Femoral; Fracture; Hip; Multivariant; Nailing; Predictive; Tip apex

Indexed keywords

ADULT; AGED; ARTICLE; BONE SCREW; CASE CONTROL STUDY; CLINICAL ASSESSMENT; CONTROLLED STUDY; CUTTING OUT; DEMOGRAPHY; DISEASE CLASSIFICATION; DISEASE SEVERITY; FEMALE; FEMUR FRACTURE; FEMUR INTERTROCHANTERIC FRACTURE; FEMUR SUBTROCHANTERIC FRACTURE; FRACTURE FIXATION; HIP FRACTURE; HUMAN; INTRAMEDULLARY NAIL; INTRAMEDULLARY NAILING; MAJOR CLINICAL STUDY; MALE; MEDICAL SOCIETY; OSTEOPOROSIS; POSTOPERATIVE COMPLICATION; PREDICTION; PREOPERATIVE EVALUATION; PRIORITY JOURNAL; RISK FACTOR; TREATMENT FAILURE; WALKING;

EID: 78149357421     PISSN: 00201383     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.injury.2010.08.009     Document Type: Article
Times cited : (124)

References (39)
  • 1
    • 0000045607 scopus 로고
    • New classification of physical status
    • ASA: American Society of Anaesthesiologists
    • ASA: American Society of Anaesthesiologists New classification of physical status Anesthesiology 23 1963 111
    • (1963) Anesthesiology , vol.23 , pp. 111
  • 2
    • 0041321380 scopus 로고    scopus 로고
    • Implant-related complications in the treatment of unstable intertrochanteric fractures: Meta-analysis of dynamic screw-plate versus dynamic screw-intramedullary nail devices
    • L. Audigé, B. Hanson, and M.F. Swiontkowski Implant-related complications in the treatment of unstable intertrochanteric fractures: meta-analysis of dynamic screw-plate versus dynamic screw-intramedullary nail devices Int Orthop 27 4 2003 197 203
    • (2003) Int Orthop , vol.27 , Issue.4 , pp. 197-203
    • Audigé, L.1    Hanson, B.2    Swiontkowski, M.F.3
  • 3
    • 0033938154 scopus 로고    scopus 로고
    • Costs induced by hip fractures: A prospective controlled study in Belgium
    • P. Autier, P. Haentjens, and J. Bentin Costs induced by hip fractures: a prospective controlled study in Belgium Osteopor Int 11 2000 373 380
    • (2000) Osteopor Int , vol.11 , pp. 373-380
    • Autier, P.1    Haentjens, P.2    Bentin, J.3
  • 4
    • 0027347366 scopus 로고
    • Healing complications after internal fixation of trochanteric hip fractures: The prognostic value of osteoporosis
    • C. Barrios, L.A. Broström, A. Stark, and G. Walheim Healing complications after internal fixation of trochanteric hip fractures: The prognostic value of osteoporosis J Orthop Trauma 7 1993 438 442
    • (1993) J Orthop Trauma , vol.7 , pp. 438-442
    • Barrios, C.1    Broström, L.A.2    Stark, A.3    Walheim, G.4
  • 5
    • 0029012764 scopus 로고
    • The value of the tip-apex distance in predicting failure of fixation of peritrochanteric fractures of the hip
    • JULY
    • M.R. Baumgaertner, S.L. Curtin, D.M. Lindskog, and J.M. Keggi The value of the tip-apex distance in predicting failure of fixation of peritrochanteric fractures of the hip J Bone Joint Surg Am 77 July (7) 1995 1058 1064
    • (1995) J Bone Joint Surg Am , vol.77 , Issue.7 , pp. 1058-1064
    • Baumgaertner, M.R.1    Curtin, S.L.2    Lindskog, D.M.3    Keggi, J.M.4
  • 6
    • 0031924186 scopus 로고    scopus 로고
    • Intramedullary versus extramedullary fixation for the treatment of intertrochanteric hip fractures
    • MARCH
    • M.R. Baumgaertner, S.L. Curtin, and D.M. Lindskog Intramedullary versus extramedullary fixation for the treatment of intertrochanteric hip fractures Clin Orthop Relat Res March (348) 1998 87 94
    • (1998) Clin Orthop Relat Res , Issue.348 , pp. 87-94
    • Baumgaertner, M.R.1    Curtin, S.L.2    Lindskog, D.M.3
  • 7
    • 26944492288 scopus 로고    scopus 로고
    • Treatment strategies for proximal femur fractures in osteoporotic patients
    • MARCH
    • F. Bonnaire, H. Zenker, and C. Lill Treatment strategies for proximal femur fractures in osteoporotic patients Osteoporos Int 16 March (Suppl. 2) 2005 S93 S102 Epub 2004 Oct 16
    • (2005) Osteoporos Int , vol.16 , Issue.SUPPL. 2
    • Bonnaire, F.1    Zenker, H.2    Lill, C.3
  • 8
    • 20444382386 scopus 로고    scopus 로고
    • Reverse obliquity and transverse fractures of the trochanteric region of the femur; A review of 101 cases
    • JULY
    • T.J. Brammar, J. Kendrew, R.J. Khan, and M.J. Parker Reverse obliquity and transverse fractures of the trochanteric region of the femur; a review of 101 cases Injury 36 July (7) 2005 851 857
    • (2005) Injury , vol.36 , Issue.7 , pp. 851-857
    • Brammar, T.J.1    Kendrew, J.2    Khan, R.J.3    Parker, M.J.4
  • 9
    • 0028082060 scopus 로고
    • Proximal femoral fractures: A biomechanical study to compare intramedullary and extramedullary fixation
    • MARCH
    • M.J. Curtis, R.H. Jinnah, V. Wilson, and B.W. Cunningham Proximal femoral fractures: a biomechanical study to compare intramedullary and extramedullary fixation Injury 25 March (2) 1994 99 104
    • (1994) Injury , vol.25 , Issue.2 , pp. 99-104
    • Curtis, M.J.1    Jinnah, R.H.2    Wilson, V.3    Cunningham, B.W.4
  • 10
    • 0025034792 scopus 로고
    • Intertrochanteric femoral fractures. Mechanical failure after internal fixation
    • T.R. Davis, J.L. Sher, and A. Horsman Intertrochanteric femoral fractures. Mechanical failure after internal fixation J Bone Joint Surg 72-B 1990 26 31
    • (1990) J Bone Joint Surg , vol.72 , pp. 26-31
    • Davis, T.R.1    Sher, J.L.2    Horsman, A.3
  • 11
    • 78149360666 scopus 로고    scopus 로고
    • Tip-apex distance of intramedullary devices as a predictor of cut-out failure in the treatment of peritrochanteric elderly hip fractures
    • J.A. Geller, C. Saifi, T.A. Morrison, and W. Macaulay Tip-apex distance of intramedullary devices as a predictor of cut-out failure in the treatment of peritrochanteric elderly hip fractures Int Orthop 2009 July 18 [Epub ahead of print]
    • (2009) Int Orthop
    • Geller, J.A.1    Saifi, C.2    Morrison, T.A.3    MacAulay, W.4
  • 12
    • 0028844606 scopus 로고
    • How to minimize failures of fixation of unstable intertrochanteric fractures
    • R. Gundle, M.F. Gargan, and A.H. Simpson How to minimize failures of fixation of unstable intertrochanteric fractures Injury 26 1995 611 614
    • (1995) Injury , vol.26 , pp. 611-614
    • Gundle, R.1    Gargan, M.F.2    Simpson, A.H.3
  • 13
    • 0345451574 scopus 로고    scopus 로고
    • Failure of femoral head fixation: A cadaveric analysis of lag screw cut-out with the gamma locking nail and AO dynamic hip screw
    • JUNE-JULY
    • R.C. Haynes, R.G. Pöll, A.W. Miles, and R.B. Weston Failure of femoral head fixation: a cadaveric analysis of lag screw cut-out with the gamma locking nail and AO dynamic hip screw Injury 28 June-July (5-6) 1997 337 341
    • (1997) Injury , vol.28 , Issue.5-6 , pp. 337-341
    • Haynes, R.C.1    Pöll, R.G.2    Miles, A.W.3    Weston, R.B.4
  • 14
    • 0036935224 scopus 로고    scopus 로고
    • A comparative study of trochanteric fractures treated with the Gamma nail or the proximal femoral nail
    • A. Herrera, L.J. Domingo, and A. Calvo A comparative study of trochanteric fractures treated with the Gamma nail or the proximal femoral nail Int Orthop 26 6 2002 365 369
    • (2002) Int Orthop , vol.26 , Issue.6 , pp. 365-369
    • Herrera, A.1    Domingo, L.J.2    Calvo, A.3
  • 15
    • 67349169045 scopus 로고    scopus 로고
    • Changes in population demographics and the future incidence of hip fracture
    • JULY
    • G. Holt, R. Smith, and K. Duncan Changes in population demographics and the future incidence of hip fracture Injury 40 July (7) 2009 722 726
    • (2009) Injury , vol.40 , Issue.7 , pp. 722-726
    • Holt, G.1    Smith, R.2    Duncan, K.3
  • 16
    • 33645286249 scopus 로고    scopus 로고
    • Are short femoral nails superior to the sliding hip screw? A meta-analysis of 24 studies involving 3279 fractures
    • APRIL
    • H.W. Jones, P. Johnston, and M. Parker Are short femoral nails superior to the sliding hip screw? A meta-analysis of 24 studies involving 3279 fractures Int Orthop 30 April (2) 2006 69 78
    • (2006) Int Orthop , vol.30 , Issue.2 , pp. 69-78
    • Jones, H.W.1    Johnston, P.2    Parker, M.3
  • 17
    • 0031925810 scopus 로고    scopus 로고
    • Cutting-out of the lag screw after internal fixation with the Asiatic gamma nail
    • JANUARY
    • S. Kawaguchi, K. Sawada, and Y. Nabeta Cutting-out of the lag screw after internal fixation with the Asiatic gamma nail Injury 29 January (1) 1998 47 53
    • (1998) Injury , vol.29 , Issue.1 , pp. 47-53
    • Kawaguchi, S.1    Sawada, K.2    Nabeta, Y.3
  • 18
    • 0035666280 scopus 로고    scopus 로고
    • Failure of intertrochanteric fracture fixation with a dynamic hip screw in relation to pre-operative fracture stability and osteoporosis
    • W.Y. Kim, C.H. Han, J.I. Park, and J.Y. Kim Failure of intertrochanteric fracture fixation with a dynamic hip screw in relation to pre-operative fracture stability and osteoporosis Int Orthop 25 6 2001 360 362
    • (2001) Int Orthop , vol.25 , Issue.6 , pp. 360-362
    • Kim, W.Y.1    Han, C.H.2    Park, J.I.3    Kim, J.Y.4
  • 19
    • 0029798690 scopus 로고    scopus 로고
    • Evaluation of the Singh index for measuring osteoporosis
    • V.C. Koot, S.M. Kesselaer, and G.J. Clevers Evaluation of the Singh index for measuring osteoporosis J Bone Joint Surg Br 78 1996 831 834
    • (1996) J Bone Joint Surg Br , vol.78 , pp. 831-834
    • Koot, V.C.1    Kesselaer, S.M.2    Clevers, G.J.3
  • 20
    • 33947625144 scopus 로고    scopus 로고
    • Epidemiology of hip fractures in Belgrade, Serbia Montenegro, 1990-2000
    • APRIL
    • A. Lesić, M. Jarebinski, and T. Pekmezović Epidemiology of hip fractures in Belgrade, Serbia Montenegro, 1990-2000 Arch Orthop Trauma Surg 127 April (3) 2007 179 183
    • (2007) Arch Orthop Trauma Surg , vol.127 , Issue.3 , pp. 179-183
    • Lesić, A.1    Jarebinski, M.2    Pekmezović, T.3
  • 21
    • 53649088337 scopus 로고    scopus 로고
    • A prospective trial comparing the Holland nail with the dynamic hip screw in the treatment of intertrochanteric fractures of the hip
    • AUGUST
    • N.J. Little, V. Verma, and C. Fernando A prospective trial comparing the Holland nail with the dynamic hip screw in the treatment of intertrochanteric fractures of the hip J Bone Joint Surg Br 90 August (8) 2008 1073 1078
    • (2008) J Bone Joint Surg Br , vol.90 , Issue.8 , pp. 1073-1078
    • Little, N.J.1    Verma, V.2    Fernando, C.3
  • 22
    • 33746805868 scopus 로고    scopus 로고
    • Increased incidence of hip fractures. A population based-study in Finland
    • SEPTEMBER
    • E. Lönnroos, H. Kautiainen, and P. Karppi Increased incidence of hip fractures. A population based-study in Finland Bone 39 September (3) 2006 623 627
    • (2006) Bone , vol.39 , Issue.3 , pp. 623-627
    • Lönnroos, E.1    Kautiainen, H.2    Karppi, P.3
  • 23
    • 0942290614 scopus 로고    scopus 로고
    • Osteoporotic pertrochanteric hip fractures. Management and current controversies
    • D.G. Lorich, D.S. Geller, and J.H. Nielson Osteoporotic pertrochanteric hip fractures. Management and current controversies J Bone Joint Surg Am 86 2004 398 410
    • (2004) J Bone Joint Surg Am , vol.86 , pp. 398-410
    • Lorich, D.G.1    Geller, D.S.2    Nielson, J.H.3
  • 24
    • 0024580353 scopus 로고
    • Implant failures in patients with proximal fractures of the femur treated with a sliding screw device
    • C.C. Mainds, and R.J. Newman Implant failures in patients with proximal fractures of the femur treated with a sliding screw device Injury 20 1989 98 100
    • (1989) Injury , vol.20 , pp. 98-100
    • Mainds, C.C.1    Newman, R.J.2
  • 25
    • 39149129995 scopus 로고    scopus 로고
    • Fracture and dislocation classification compendium - 2007: Orthopaedic trauma association classification, database and outcomes committee
    • NOVEMBER-DECEMBER
    • J.L. Marsh, T.F. Slongo, and J. Agel Fracture and dislocation classification compendium - 2007: orthopaedic trauma association classification, database and outcomes committee J Orthop Trauma 21 November-December (10 Suppl.) 2007 S1 S133
    • (2007) J Orthop Trauma , vol.21 , Issue.10 SUPPL.
    • Marsh, J.L.1    Slongo, T.F.2    Agel, J.3
  • 26
    • 62549086509 scopus 로고    scopus 로고
    • The AO/ASIF proximal femoral nail antirotation (PFNA): A new design for the treatment of unstable proximal femoral fractures
    • APRIL
    • P. Mereddy, S. Kamath, and M. Ramakrishnan The AO/ASIF proximal femoral nail antirotation (PFNA): a new design for the treatment of unstable proximal femoral fractures Injury 40 April (4) 2009 428 432
    • (2009) Injury , vol.40 , Issue.4 , pp. 428-432
    • Mereddy, P.1    Kamath, S.2    Ramakrishnan, M.3
  • 27
    • 56949100948 scopus 로고    scopus 로고
    • What's new in the management of proximal femoral fractures?
    • DECEMBER
    • V.S. Nikolaou, A. Papathanasopoulos, and P.V. Giannoudis What's new in the management of proximal femoral fractures? Injury 39 December (12) 2008 1309 1318
    • (2008) Injury , vol.39 , Issue.12 , pp. 1309-1318
    • Nikolaou, V.S.1    Papathanasopoulos, A.2    Giannoudis, P.V.3
  • 28
    • 0033868742 scopus 로고    scopus 로고
    • The cost and implications of reoperation after surgery for fracture of the hip
    • S.J. Palmer, M.J. Parker, and W. Hollingworth The cost and implications of reoperation after surgery for fracture of the hip J Bone Joint Surg 82B 2000 864 866
    • (2000) J Bone Joint Surg , vol.82 , pp. 864-866
    • Palmer, S.J.1    Parker, M.J.2    Hollingworth, W.3
  • 29
    • 0026764040 scopus 로고
    • Cutting out of the dynamic hip screw related to its position
    • M.J. Parker Cutting out of the dynamic hip screw related to its position J Bone Joint Surg 74B 1992 625
    • (1992) J Bone Joint Surg , vol.74 , pp. 625
    • Parker, M.J.1
  • 30
    • 85046499999 scopus 로고    scopus 로고
    • Failure of femoral head fixation: A cadaveric analysis of lag screw cut-out with the gamma locking nail and the AO dynamic hip screw
    • SEPTEMBER
    • M.J. Parker Failure of femoral head fixation: a cadaveric analysis of lag screw cut-out with the gamma locking nail and the AO dynamic hip screw Injury 29 September (7) 1998 596
    • (1998) Injury , vol.29 , Issue.7 , pp. 596
    • Parker, M.J.1
  • 31
    • 0027196249 scopus 로고
    • Valgus reduction of trochanteric fractures
    • MAY
    • M.J. Parker Valgus reduction of trochanteric fractures Injury 24 May (5) 1993 313 316
    • (1993) Injury , vol.24 , Issue.5 , pp. 313-316
    • Parker, M.J.1
  • 32
    • 21744461436 scopus 로고    scopus 로고
    • Review of methods to quantify lag screw placement in hip fracture fixation
    • JUNE
    • V. Parmar, S. Kumar, A. Aster, and W.H. Harper Review of methods to quantify lag screw placement in hip fracture fixation Acta Orthop Belg 71 June (3) 2005 260 263
    • (2005) Acta Orthop Belg , vol.71 , Issue.3 , pp. 260-263
    • Parmar, V.1    Kumar, S.2    Aster, A.3    Harper, W.H.4
  • 33
    • 4444241897 scopus 로고    scopus 로고
    • Prediction of fixation failure after sliding hip screw fixation
    • OCTOBER
    • H. Pervez, M.J. Parker, and S. Vowler Prediction of fixation failure after sliding hip screw fixation Injury 35 October (10) 2004 994 998
    • (2004) Injury , vol.35 , Issue.10 , pp. 994-998
    • Pervez, H.1    Parker, M.J.2    Vowler, S.3
  • 34
    • 0027170493 scopus 로고
    • A prospective randomised comparison of the dynamic hip screw and the gamma locking nail
    • SEPTEMBER
    • P.J. Radford, M. Needoff, and J.K. Webb A prospective randomised comparison of the dynamic hip screw and the gamma locking nail J Bone Joint Surg Br 75 September (5) 1993 789 793
    • (1993) J Bone Joint Surg Br , vol.75 , Issue.5 , pp. 789-793
    • Radford, P.J.1    Needoff, M.2    Webb, J.K.3
  • 35
    • 0014775852 scopus 로고
    • Changes in trabecular pattern of the upper end of the femur as an index of osteoporosis
    • APRIL
    • M. Singh, A.R. Nagrath, and P.S. Maini Changes in trabecular pattern of the upper end of the femur as an index of osteoporosis J Bone Joint Surg Am 52 April (3) 1970 457 467
    • (1970) J Bone Joint Surg Am , vol.52 , Issue.3 , pp. 457-467
    • Singh, M.1    Nagrath, A.R.2    Maini, P.S.3
  • 36
    • 37549061451 scopus 로고    scopus 로고
    • Are there advances in the treatment of extracapsular hip fractures in the elderly?
    • JANUARY
    • R. Stern Are there advances in the treatment of extracapsular hip fractures in the elderly? Injury 39 January (1) 2008 140
    • (2008) Injury , vol.39 , Issue.1 , pp. 140
    • Stern, R.1
  • 37
    • 0035728321 scopus 로고    scopus 로고
    • Prevention of hip lag screw cut-out in osteoporotic patients. Rationale and review of the literature
    • M. Szpalski, and R. Gunzburg Prevention of hip lag screw cut-out in osteoporotic patients. Rationale and review of the literature Bull Hosp Jt Dis 60 2 2001-2002 84 88
    • (2001) Bull Hosp Jt Dis , vol.60 , Issue.2 , pp. 84-88
    • Szpalski, M.1    Gunzburg, R.2
  • 38
    • 0026071143 scopus 로고
    • Dynamic hip screws that fail
    • A.P. Thomas Dynamic hip screws that fail Injury 22 1991 45 46
    • (1991) Injury , vol.22 , pp. 45-46
    • Thomas, A.P.1
  • 39
    • 26444544187 scopus 로고    scopus 로고
    • Femoral neck-shaft angle in extra-capsular proximal femoral fracture fixation; Does it make a TAD of difference?
    • NOVEMBER
    • N.P. Walton, H. Wynn-Jones, M.S. Ward, and J.A. Wimhurst Femoral neck-shaft angle in extra-capsular proximal femoral fracture fixation; does it make a TAD of difference? Injury 36 November (11) 2005 1361 1364
    • (2005) Injury , vol.36 , Issue.11 , pp. 1361-1364
    • Walton, N.P.1    Wynn-Jones, H.2    Ward, M.S.3    Wimhurst, J.A.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.