-
1
-
-
33845220491
-
Dosimetric verification of the anisotropic analytical algorithm for radiotherapy treatment planning
-
Bragg C M and Conway J 2006 Dosimetric verification of the anisotropic analytical algorithm for radiotherapy treatment planning Radiother. Oncol. 81 315-23
-
(2006)
Radiother. Oncol.
, vol.81
, pp. 315-323
-
-
Bragg, C.M.1
Conway, J.2
-
2
-
-
51849154948
-
Monte Carlo simulation of RapidArc radiotherapy delivery
-
Bush K, Townson R and Zavgorodni S 2008 Monte Carlo simulation of RapidArc radiotherapy delivery Phys. Med. Biol. 53 N359-70
-
(2008)
Phys. Med. Biol.
, vol.53
-
-
Bush, K.1
Townson, R.2
Zavgorodni, S.3
-
3
-
-
34347393495
-
Impact of inhomogeneity corrections on dose coverage in the treatment of lung cancer using stereotactic body radiation therapy
-
Ding G X, Duggan D M, Lu B, Hallahan D E, Cmelak A, Malcolm A, Newton J, Deeley M and Coffey C W 2007 Impact of inhomogeneity corrections on dose coverage in the treatment of lung cancer using stereotactic body radiation therapy Med. Phys. 34 2985-94
-
(2007)
Med. Phys.
, vol.34
, pp. 2985-2994
-
-
Ding, G.X.1
Duggan, D.M.2
Lu, B.3
Hallahan, D.E.4
Cmelak, A.5
Malcolm, A.6
Newton, J.7
Deeley, M.8
Coffey, C.W.9
-
4
-
-
33644694219
-
Dosimetric validation of the anisotropic analytical algorithm for photon dose calculation: Fundamental characterization in water
-
Fogliata A, Nicolini G, Vanetti E, Clivio A and Cozzi L 2006 Dosimetric validation of the anisotropic analytical algorithm for photon dose calculation: fundamental characterization in water Phys. Med. Biol. 51 1421-38
-
(2006)
Phys. Med. Biol.
, vol.51
, pp. 1421-1438
-
-
Fogliata, A.1
Nicolini, G.2
Vanetti, E.3
Clivio, A.4
Cozzi, L.5
-
6
-
-
58149236841
-
A Monte Carlo evaluation of RapidArc dose calculations for oropharynx radiotherapy
-
Gagne I M, Ansbacher W, Zavgorodni S, Popescu C and Beckham W A 2008 A Monte Carlo evaluation of RapidArc dose calculations for oropharynx radiotherapy Phys. Med. Biol. 53 7167-85
-
(2008)
Phys. Med. Biol.
, vol.53
, pp. 7167-7185
-
-
Gagne, I.M.1
Ansbacher, W.2
Zavgorodni, S.3
Popescu, C.4
Beckham, W.A.5
-
7
-
-
34247337632
-
Evaluation of the analytical anisotropic algorithm (AAA) in an extreme water-lung interface phantom using Monte Carlo dose calculations
-
Gagne I M and Zavgorodni S F 2007 Evaluation of the analytical anisotropic algorithm (AAA) in an extreme water-lung interface phantom using Monte Carlo dose calculations J. Appl. Clin. Med. Phys. 8 33-46
-
(2007)
J. Appl. Clin. Med. Phys.
, vol.8
, pp. 33-46
-
-
Gagne, I.M.1
Zavgorodni, S.F.2
-
8
-
-
34250350470
-
Collapsed cone convolution and analytical anisotropic algorithm dose calculations compared to VMC++ Monte Carlo simulations in clinical cases
-
Hasenbalg F, Neuenschwander H, Mini R and Born E J 2007 Collapsed cone convolution and analytical anisotropic algorithm dose calculations compared to VMC++ Monte Carlo simulations in clinical cases Phys. Med. Biol. 52 3679-91
-
(2007)
Phys. Med. Biol.
, vol.52
, pp. 3679-3691
-
-
Hasenbalg, F.1
Neuenschwander, H.2
Mini, R.3
Born, E.J.4
-
10
-
-
0035058901
-
Monte Carlo dose calculations for dynamic IMRT treatments
-
Keall P J, Siebers J V, Arnfield M, Kim J O and Mohan R 2001 Monte Carlo dose calculations for dynamic IMRT treatments Phys. Med. Biol. 46 929-41
-
(2001)
Phys. Med. Biol.
, vol.46
, pp. 929-941
-
-
Keall, P.J.1
Siebers, J.V.2
Arnfield, M.3
Kim, J.O.4
Mohan, R.5
-
11
-
-
33846882623
-
Comparison of dose calculation algorithms for treatment planning in external photon beam therapy for clinical situations
-
Knöös T, Wieslander E, Cozzi L, Brink C, Fogliata A, Albers D, Nyström H and Lassen S 2006 Comparison of dose calculation algorithms for treatment planning in external photon beam therapy for clinical situations Phys. Med. Biol. 51 5785-807
-
(2006)
Phys. Med. Biol.
, vol.51
, pp. 5785-5807
-
-
Knöös, T.1
Wieslander, E.2
Cozzi, L.3
Brink, C.4
Fogliata, A.5
Albers, D.6
Nyström, H.7
Lassen, S.8
-
12
-
-
60749097121
-
Vega library for processing DICOM data required in Monte Carlo verification of radiotherapy treatment plans
-
Locke C and Zavgorodni S 2008 Vega library for processing DICOM data required in Monte Carlo verification of radiotherapy treatment plans Australas. Phys. Eng. Sci. Med. 31 290-9
-
(2008)
Australas. Phys. Eng. Sci. Med.
, vol.31
, pp. 290-299
-
-
Locke, C.1
Zavgorodni, S.2
-
13
-
-
33645506880
-
Analytic IMRT dose calculations utilizing Monte Carlo to predict MLC fluence modulation
-
Mihaylov I B, Lerma F A, Wu Y and Siebers J V 2006 Analytic IMRT dose calculations utilizing Monte Carlo to predict MLC fluence modulation Med. Phys. 33 828-39
-
(2006)
Med. Phys.
, vol.33
, pp. 828-839
-
-
Mihaylov, I.B.1
Lerma, F.A.2
Wu, Y.3
Siebers, J.V.4
-
14
-
-
48349131853
-
Evaluation of dose prediction errors and optimization convergence errors of deliverable-based head-and-neck IMRT plans computed with a superposition/convolution dose algorithm
-
Mihaylov I B and Siebers J V 2008 Evaluation of dose prediction errors and optimization convergence errors of deliverable-based head-and-neck IMRT plans computed with a superposition/convolution dose algorithm Med. Phys. 35 3722-7
-
(2008)
Med. Phys.
, vol.35
, pp. 3722-3727
-
-
Mihaylov, I.B.1
Siebers, J.V.2
-
15
-
-
37549049393
-
Volumetric modulated arc therapy: IMRT in a single gantry arc
-
Otto K 2008 Volumetric modulated arc therapy: IMRT in a single gantry arc Med. Phys. 35 310-7
-
(2008)
Med. Phys.
, vol.35
, pp. 310-317
-
-
Otto, K.1
-
17
-
-
0029035150
-
BEAM: A Monte Carlo code to simulate radiotherapy treatment units
-
Rogers D W, Faddegon B A, Ding G X, Ma C M, We J and Mackie T R 1995 BEAM: a Monte Carlo code to simulate radiotherapy treatment units Med. Phys. 22 503-24
-
(1995)
Med. Phys.
, vol.22
, pp. 503-524
-
-
Rogers, D.W.1
Faddegon, B.A.2
Ding, G.X.3
Ma, C.M.4
We, J.5
Mackie, T.R.6
-
18
-
-
31844436389
-
Monte Carlo-based dosimetry of head-and-neck patients treated with SIB-IMRT
-
Sakthi N, Keall P J, Mihaylov I, Wu Q, Wu Y, Williamson J F, Schmidt-Ullrich R K and Siebers J V 2006 Monte Carlo-based dosimetry of head-and-neck patients treated with SIB-IMRT Int. J. Radiat. Oncol. Biol. Phys. 64 968-77
-
(2006)
Int. J. Radiat. Oncol. Biol. Phys.
, vol.64
, pp. 968-977
-
-
Sakthi, N.1
Keall, P.J.2
Mihaylov, I.3
Wu, Q.4
Wu, Y.5
Williamson, J.F.6
Schmidt-Ullrich, R.K.7
Siebers, J.V.8
-
19
-
-
0037037135
-
A method for photon beam Monte Carlo multileaf collimator particle transport
-
Siebers J V, Keall P J, Kim J O and Mohan R 2002 A method for photon beam Monte Carlo multileaf collimator particle transport Phys. Med. Biol. 47 3225-49
-
(2002)
Phys. Med. Biol.
, vol.47
, pp. 3225-3249
-
-
Siebers, J.V.1
Keall, P.J.2
Kim, J.O.3
Mohan, R.4
-
20
-
-
0034036210
-
Converting absorbed dose to medium to absorbed dose to water for Monte Carlo based photon beam dose calculations
-
Siebers J V, Keall P J, Nahum A E and Mohan R 2000 Converting absorbed dose to medium to absorbed dose to water for Monte Carlo based photon beam dose calculations Phys. Med. Biol. 45 983-95
-
(2000)
Phys. Med. Biol.
, vol.45
, pp. 983-995
-
-
Siebers, J.V.1
Keall, P.J.2
Nahum, A.E.3
Mohan, R.4
-
21
-
-
14544306963
-
Implementation of random set-up errors in Monte Carlo calculated dynamic IMRT treatment plans
-
Stapleton S, Zavgorodni S, Popescu I A and Beckham W A 2005 Implementation of random set-up errors in Monte Carlo calculated dynamic IMRT treatment plans Phys. Med. Biol. 50 429-39
-
(2005)
Phys. Med. Biol.
, vol.50
, pp. 429-439
-
-
Stapleton, S.1
Zavgorodni, S.2
Popescu, I.A.3
Beckham, W.A.4
-
22
-
-
22844450224
-
A 3D photon superposition/convolution algorithm and its foundation on results of Monte Carlo calculations
-
Ulmer W, Pyyry J and Kaissl W 2005 A 3D photon superposition/convolution algorithm and its foundation on results of Monte Carlo calculations Phys. Med. Biol. 50 1767-90
-
(2005)
Phys. Med. Biol.
, vol.50
, pp. 1767-1790
-
-
Ulmer, W.1
Pyyry, J.2
Kaissl, W.3
-
23
-
-
33750574559
-
Testing of the analytical anisotropic algorithm for photon dose calculation
-
Van Esch A, Tillikainen L, Pyykkonen J, Tenhunen M, Helminen H, Siljamäki S, Alakuijala J, Paiusco M, Lori M and Huyskens D P 2006 Testing of the analytical anisotropic algorithm for photon dose calculation Med. Phys. 33 4130-48
-
(2006)
Med. Phys.
, vol.33
, pp. 4130-4148
-
-
Van Esch, A.1
Tillikainen, L.2
Pyykkonen, J.3
Tenhunen, M.4
Helminen, H.5
Siljamäki, S.6
Alakuijala, J.7
Paiusco, M.8
Lori, M.9
Huyskens, D.P.10
|