메뉴 건너뛰기




Volumn 55, Issue 6, 2010, Pages 1582-1591

Using gas chromatography with ion mobility spectrometry to resolve explosive compounds in the presence of interferents

Author keywords

Contraband; Explosives; Forensic science; Gas chromatography; Ion mobility; Ion mobility spectrometry; Portable; Screening

Indexed keywords


EID: 78149316897     PISSN: 00221198     EISSN: 15564029     Source Type: Journal    
DOI: 10.1111/j.1556-4029.2010.01522.x     Document Type: Article
Times cited : (72)

References (38)
  • 1
    • 0001042806 scopus 로고
    • Qualitative studies of trace constituents by plasma chromatography
    • Karasek FW, Kilpatrick WD, Cohen MJ. Qualitative studies of trace constituents by plasma chromatography. Anal Chem 1971;43:1441-7.
    • (1971) Anal Chem , vol.43 , pp. 1441-1447
    • Karasek, F.W.1    Kilpatrick, W.D.2    Cohen, M.J.3
  • 2
    • 84963092310 scopus 로고
    • Gas chromatograph/plasma chromatograph interface and its performance in the detection of musk ambrette
    • Karasek FW, Keller RA. Gas chromatograph/plasma chromatograph interface and its performance in the detection of musk ambrette. J Chromatogr Sci 1972;10:626-8.
    • (1972) J Chromatogr Sci , vol.10 , pp. 626-628
    • Karasek, F.W.1    Keller, R.A.2
  • 3
    • 33845560326 scopus 로고
    • Comparison of the negative reactant ions formed in the plasma chromatograph by nitrogen, air, and sulfur hexafluoride as the drift gas with air as the carrier gas
    • Carr TW. Comparison of the negative reactant ions formed in the plasma chromatograph by nitrogen, air, and sulfur hexafluoride as the drift gas with air as the carrier gas. Anal Chem 1979;51(6):705-11.
    • (1979) Anal Chem , vol.51 , Issue.6 , pp. 705-711
    • Carr, T.W.1
  • 4
    • 0020549887 scopus 로고
    • Halogenated compound response in an oxygen doped ion mobility detector for capillary gas chromatography
    • Baim MA, Hill HH. Halogenated compound response in an oxygen doped ion mobility detector for capillary gas chromatography. J High Resolut Chromatogr Chromatogr Commun 1983;6:4-10.
    • (1983) J High Resolut Chromatogr Chromatogr Commun , vol.6 , pp. 4-10
    • Baim, M.A.1    Hill, H.H.2
  • 5
    • 0033181259 scopus 로고    scopus 로고
    • Ion mobility spectrometry: arriving on site and moving beyond low profile
    • Baumbach JI, Eiceman GA. Ion mobility spectrometry: arriving on site and moving beyond low profile. Appl Spectrosc 1999;53(9):338A-55A.
    • (1999) Appl Spectrosc , vol.53 , Issue.9
    • Baumbach, J.I.1    Eiceman, G.A.2
  • 6
    • 78149290687 scopus 로고    scopus 로고
    • The utilization of ion mobility spectrometry in a criminal justice field
    • Mieczkowski T. The utilization of ion mobility spectrometry in a criminal justice field. Drug Test Technol 1999;67:73-89.
    • (1999) Drug Test Technol , vol.67 , pp. 73-89
    • Mieczkowski, T.1
  • 7
    • 0035837523 scopus 로고    scopus 로고
    • A critical review of ion mobility spectrometry for the detection of explosives and explosive related compounds
    • Ewing RG, Atkinson DA, Eiceman GA, Ewing GJ. A critical review of ion mobility spectrometry for the detection of explosives and explosive related compounds. Talanta 2001;54(3):515-29.
    • (2001) Talanta , vol.54 , Issue.3 , pp. 515-529
    • Ewing, R.G.1    Atkinson, D.A.2    Eiceman, G.A.3    Ewing, G.J.4
  • 8
    • 0036062587 scopus 로고    scopus 로고
    • Field detection and monitoring of explosives
    • Yinon J. Field detection and monitoring of explosives. Trends Analyt Chem 2002;21(4):292-301.
    • (2002) Trends Analyt Chem , vol.21 , Issue.4 , pp. 292-301
    • Yinon, J.1
  • 9
    • 0042669862 scopus 로고    scopus 로고
    • Characterization of the explosive triacetone triperoxide and detection by ion mobility spectrometry
    • Buttigieg GA, Knight AK, Denson S, Pommier C, Bonner Denton M. Characterization of the explosive triacetone triperoxide and detection by ion mobility spectrometry. Forensic Sci Int 2003;135:53-9.
    • (2003) Forensic Sci Int , vol.135 , pp. 53-59
    • Buttigieg, G.A.1    Knight, A.K.2    Denson, S.3    Pommier, C.4    Bonner Denton, M.5
  • 10
    • 7644233200 scopus 로고    scopus 로고
    • Ion mobility spectrometers in national defense
    • Eiceman GA, Stone JA. Ion mobility spectrometers in national defense. Anal Chem 2004;76(21):390A-6A.
    • (2004) Anal Chem , vol.76 , Issue.21
    • Eiceman, G.A.1    Stone, J.A.2
  • 11
    • 2442704333 scopus 로고    scopus 로고
    • Secondary electrospray ionization-ion mobility spectrometry for explosive vapor detection
    • Tam M, Hill HH. Secondary electrospray ionization-ion mobility spectrometry for explosive vapor detection. Anal Chem 2004;76:2741-7.
    • (2004) Anal Chem , vol.76 , pp. 2741-2747
    • Tam, M.1    Hill, H.H.2
  • 12
    • 0004269112 scopus 로고    scopus 로고
    • Ion mobility spectrometry
    • 2nd rev. edn. Boca Rotan, FL: Taylor and Francis
    • Eiceman GA, Karpas Z. Ion mobility spectrometry, 2nd rev. edn. Boca Rotan, FL: Taylor and Francis, 2005.
    • (2005)
    • Eiceman, G.A.1    Karpas, Z.2
  • 13
    • 14944377507 scopus 로고    scopus 로고
    • Solid phase microextraction ion mobility spectrometer interface for explosive and taggant detection
    • Perr JM, Furton KG, Almirall JR. Solid phase microextraction ion mobility spectrometer interface for explosive and taggant detection. J Sep Sci 2006;28(2):177-83.
    • (2006) J Sep Sci , vol.28 , Issue.2 , pp. 177-183
    • Perr, J.M.1    Furton, K.G.2    Almirall, J.R.3
  • 14
    • 33745254226 scopus 로고    scopus 로고
    • Ion mobility spectrometry: principles and applications
    • Borsdorf H, Eiceman GA. Ion mobility spectrometry: principles and applications. Appl Spectrosc Rev 2006;41(4):323-75.
    • (2006) Appl Spectrosc Rev , vol.41 , Issue.4 , pp. 323-375
    • Borsdorf, H.1    Eiceman, G.A.2
  • 16
    • 46149122501 scopus 로고    scopus 로고
    • Determination of gas phase triacetone triperoxide with aspiration ion mobility spectrometry and gas chromatography-mass spectrometry
    • Rasanen RM, Nousiainen M, Perakorpi K, Sillanpaa M, Polari L, Annttalainen O, et al. Determination of gas phase triacetone triperoxide with aspiration ion mobility spectrometry and gas chromatography-mass spectrometry. Anal Chim Acta 2008;623:59-65.
    • (2008) Anal Chim Acta , vol.623 , pp. 59-65
    • Rasanen, R.M.1    Nousiainen, M.2    Perakorpi, K.3    Sillanpaa, M.4    Polari, L.5    Annttalainen, O.6
  • 17
    • 0002619377 scopus 로고
    • The plasma chromatograph research/development
    • Karasek FW. The plasma chromatograph research/development. Research/Development 1970;21:34-7.
    • (1970) Research/Development , vol.21 , pp. 34-37
    • Karasek, F.W.1
  • 18
    • 78149310400 scopus 로고
    • Analysis of organic surface contamination by plasma chromatography/mass spectroscopy
    • New York, NY: Plenum Publishing Corporation
    • Carr TW, Needham CD. Analysis of organic surface contamination by plasma chromatography/mass spectroscopy. New York, NY: Plenum Publishing Corporation, 1979.
    • (1979)
    • Carr, T.W.1    Needham, C.D.2
  • 19
    • 0026442206 scopus 로고
    • Ion mobility spectrometry of drugs of abuse in customs scenarios: concentration and temperature study
    • Fytche LM, Hupe M, Kovar JB, Pilon P. Ion mobility spectrometry of drugs of abuse in customs scenarios: concentration and temperature study. J Forensic Sci 1992;37(6):1550-66.
    • (1992) J Forensic Sci , vol.37 , Issue.6 , pp. 1550-1566
    • Fytche, L.M.1    Hupe, M.2    Kovar, J.B.3    Pilon, P.4
  • 20
    • 0028914261 scopus 로고
    • Enhanced selectivity in ion mobility spectrometry analysis of complex mixtures by alternate reagent gas chemistry
    • Eiceman GA, Wang YF, Harden CS, Shoff DB. Enhanced selectivity in ion mobility spectrometry analysis of complex mixtures by alternate reagent gas chemistry. Anal Chem 1995;306:21-33.
    • (1995) Anal Chem , vol.306 , pp. 21-33
    • Eiceman, G.A.1    Wang, Y.F.2    Harden, C.S.3    Shoff, D.B.4
  • 21
    • 0022060984 scopus 로고
    • Recent advances in ion mobility spectrometry for explosives vapor detection
    • Spangler GE, Carrico JP, Campbell DN. Recent advances in ion mobility spectrometry for explosives vapor detection. J Test Eval 1985;13:234-40.
    • (1985) J Test Eval , vol.13 , pp. 234-240
    • Spangler, G.E.1    Carrico, J.P.2    Campbell, D.N.3
  • 22
    • 0025582389 scopus 로고
    • Ion mobility spectrometry
    • December 1, 1990.
    • Hill HH, Siems WF, Louis RH. Ion mobility spectrometry. Anal Chem 1990;62(23):1201A-9A. December 1, 1990.
    • (1990) Anal Chem , vol.62 , Issue.23
    • Hill, H.H.1    Siems, W.F.2    Louis, R.H.3
  • 23
    • 0000171258 scopus 로고
    • Portable hand-held gas chromatography/ion mobility spectrometry device
    • Snyder AP, Harden CS. Portable hand-held gas chromatography/ion mobility spectrometry device. Anal Chem 1993;65:299-306.
    • (1993) Anal Chem , vol.65 , pp. 299-306
    • Snyder, A.P.1    Harden, C.S.2
  • 24
    • 0035970938 scopus 로고    scopus 로고
    • Evaluation of suspected interferents for TNT detection by ion mobility spectrometry
    • Matz LM, Tornatore PS, Hill HH. Evaluation of suspected interferents for TNT detection by ion mobility spectrometry. Talanta 2004;54:171-9.
    • (2004) Talanta , vol.54 , pp. 171-179
    • Matz, L.M.1    Tornatore, P.S.2    Hill, H.H.3
  • 25
    • 0019897852 scopus 로고
    • Tunable selective detection for capillary gas chromatography
    • Baim MA, Herbert HH. Tunable selective detection for capillary gas chromatography. Anal Chem 1982;54:38-43.
    • (1982) Anal Chem , vol.54 , pp. 38-43
    • Baim, M.A.1    Herbert, H.H.2
  • 27
    • 78149322649 scopus 로고    scopus 로고
    • Explosives detection technology
    • Barringer Instruments GC-IONSCAN, 2000, Interagency Agreement Number DW89937854, Document Number EPA-VS-SCM-45.
    • Dindal AB, Bayne CK, Jenkins RA, Koglin EN. Explosives detection technology. Barringer Instruments GC-IONSCAN, 2000, Interagency Agreement Number DW89937854, Document Number EPA-VS-SCM-45.
    • Dindal, A.B.1    Bayne, C.K.2    Jenkins, R.A.3    Koglin, E.N.4
  • 28
    • 34548570101 scopus 로고    scopus 로고
    • Forensic application of gas chromatography-differential mobility spectrometry with two-way classification of ignitable liquids from fire debris
    • Luo Y, Harrington PB. Forensic application of gas chromatography-differential mobility spectrometry with two-way classification of ignitable liquids from fire debris. Anal Chem 2007;79(17):6752-9.
    • (2007) Anal Chem , vol.79 , Issue.17 , pp. 6752-6759
    • Luo, Y.1    Harrington, P.B.2
  • 29
    • 37149049631 scopus 로고    scopus 로고
    • Ion mobility spectrometry detection for gas chromatography
    • Kanu AB, Hill HH. Ion mobility spectrometry detection for gas chromatography. J Chromatogr A 2008;1177:12-27.
    • (2008) J Chromatogr A , vol.1177 , pp. 12-27
    • Kanu, A.B.1    Hill, H.H.2
  • 30
    • 0344478516 scopus 로고    scopus 로고
    • Guide for the selection of commercial explosives detection systems for law enforcement applications
    • Washington, DC: National Institute of Justice, Sept; Report No.: 100-99, Interagency Agreement No 94-IJ-R-004, Project No 97-028-CTT, Document Number NIH Guide 100-99.
    • Rhykerd CL, Hannum DW, Murray DW, Parmeter JE. Guide for the selection of commercial explosives detection systems for law enforcement applications. Washington, DC: National Institute of Justice, 1999 Sept; Report No.: 100-99, Interagency Agreement No 94-IJ-R-004, Project No 97-028-CTT, Document Number NIH Guide 100-99.
    • (1999)
    • Rhykerd, C.L.1    Hannum, D.W.2    Murray, D.W.3    Parmeter, J.E.4
  • 31
    • 0037677901 scopus 로고    scopus 로고
    • The use of GC-IMS to analyze high volume vapour samples from cargo containers
    • LaFontaine P, Pilon P, Morrison R, Neudorfl P. The use of GC-IMS to analyze high volume vapour samples from cargo containers. Int J Ion Mobil Spectrom 2001;4(1):34-6.
    • (2001) Int J Ion Mobil Spectrom , vol.4 , Issue.1 , pp. 34-36
    • LaFontaine, P.1    Pilon, P.2    Morrison, R.3    Neudorfl, P.4
  • 32
    • 78149356730 scopus 로고
    • Hyphenated techniques; the next generation of field-portable analytical instruments
    • Proceedings of the Ninth International Symposium on Field Screening Methods for Hazardous Wastes and Toxic Chemicals; 1995 Feb 22-24; Las Vegas, NV. Pittsburgh, PA: Air and Waste Management Association
    • Meuzelaar HLC, McClennen WH, Dworzanski JP, Sheya SA, Snyder AP, Harden CS, et al. Hyphenated techniques; the next generation of field-portable analytical instruments. Proceedings of the Ninth International Symposium on Field Screening Methods for Hazardous Wastes and Toxic Chemicals; 1995 Feb 22-24; Las Vegas, NV. Pittsburgh, PA: Air and Waste Management Association, 1995;38-47.
    • (1995) , pp. 38-47
    • Meuzelaar, H.L.C.1    McClennen, W.H.2    Dworzanski, J.P.3    Sheya, S.A.4    Snyder, A.P.5    Harden, C.S.6
  • 33
    • 78149351498 scopus 로고    scopus 로고
    • Proceedings of the 1996 ERDEC Scientific Conference on Chemical and Biological Defense Research; 1996 Nov 19-22
    • In: Berg DA, editor. ; Aberdeen Proving Ground, MD. Springfield, VA: National Technical Information Service
    • Arnold NS, Hall DL, Wilson R, Snyder AP. A new hand-portable gas chromatography/ion mobility spectrometry system for chemical detection applications. In: Berg DA, editor. Proceedings of the 1996 ERDEC Scientific Conference on Chemical and Biological Defense Research; 1996 Nov 19-22; Aberdeen Proving Ground, MD. Springfield, VA: National Technical Information Service, 1996;225-31.
    • (1996) A new hand-portable gas chromatography/ion mobility spectrometry system for chemical detection applications , pp. 225-231
    • Arnold, N.S.1    Hall, D.L.2    Wilson, R.3    Snyder, A.P.4
  • 34
    • 29944433490 scopus 로고    scopus 로고
    • Closed tube sample introduction for gas chromatography-ion mobility spectrometry analysis of water contaminated with a chemical warfare agent surrogate compound
    • Erickson RP, Tripathi A, Maswadeh WM, Snyder AP, Smith PA. Closed tube sample introduction for gas chromatography-ion mobility spectrometry analysis of water contaminated with a chemical warfare agent surrogate compound. Anal Chim Acta Vol 2006;556(2):455-61.
    • (2006) Anal Chim Acta Vol , vol.556 , Issue.2 , pp. 455-461
    • Erickson, R.P.1    Tripathi, A.2    Maswadeh, W.M.3    Snyder, A.P.4    Smith, P.A.5
  • 35
    • 39149126316 scopus 로고    scopus 로고
    • Rapid preseparation of interferences for ion mobility spectrometry
    • Kanu AB, Ching W, Hill HH. Rapid preseparation of interferences for ion mobility spectrometry. Anal Chim Acta 2008;610:125-34.
    • (2008) Anal Chim Acta , vol.610 , pp. 125-134
    • Kanu, A.B.1    Ching, W.2    Hill, H.H.3
  • 36
    • 0038365664 scopus 로고    scopus 로고
    • Development and evaluation of a low thermal mass gas chromatograph for rapid forensic GC-MS analyses
    • Sloan KM, Mustacich RV, Eckenrode BA. Development and evaluation of a low thermal mass gas chromatograph for rapid forensic GC-MS analyses. Field Analyt Chem Technol 2001;5(6):288-301.
    • (2001) Field Analyt Chem Technol , vol.5 , Issue.6 , pp. 288-301
    • Sloan, K.M.1    Mustacich, R.V.2    Eckenrode, B.A.3
  • 37
    • 14944373218 scopus 로고    scopus 로고
    • Towards smaller and faster gas chromatography-mass spectrometry systems for field chemical detection
    • Smith PA, Sng MT, Eckenrode BA, Leow SY, Koch D, Erickson RP, et al. Towards smaller and faster gas chromatography-mass spectrometry systems for field chemical detection. J Chromatogr A 2005;1067:285-94.
    • (2005) J Chromatogr A , vol.1067 , pp. 285-294
    • Smith, P.A.1    Sng, M.T.2    Eckenrode, B.A.3    Leow, S.Y.4    Koch, D.5    Erickson, R.P.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.