1
-
-
74049102570
-
Medical Devices Directive 2007/47/EC of Sept. 5th, 2007, amending Council Directive 93/42/EEC of Jun. 14th, 1993
-
Medical Devices Directive 2007/47/EC of Sept. 5th, 2007, amending Council Directive 93/42/EEC of Jun. 14th, 1993. Official Journal of the European Union 247 (L): 21-55, 2007
-
(2007)
Official Journal of the European Union
, vol.247
, Issue.50
, pp. 21-55
-
-
-
3
-
-
0003702671
-
-
IEC 61025: 2nd Ed., Geneva, International Electrotechnical Commission
-
IEC 61025: Fault Tree Analysis (FTA), 2nd Ed., Geneva, International Electrotechnical Commission, 2006
-
(2006)
Fault Tree Analysis (FTA)
-
-
-
5
-
-
24044484898
-
Hemodialysis machines and monitors
-
5th Ed., edited by Hörl WH, Koch KM, Lindsay RM, Ronco C, Winchester JF, Dordrecht, The Netherlands, Kluwer Academic Publishers
-
Polaschegg HD, Levin NW: Hemodialysis machines and monitors. In: Replacement of Renal Function By Dialysis, 5th Ed., edited by Hörl WH, Koch KM, Lindsay RM, Ronco C, Winchester JF, Dordrecht, The Netherlands, Kluwer Academic Publishers, 2004, pp 325-449
-
(2004)
Replacement of Renal Function by Dialysis
, pp. 325-449
-
-
Polaschegg, H.D.1
Levin, N.W.2
-
7
-
-
0002530314
-
Body temperature, temperature regulation, and fever
-
10th Ed., Philadelphia, WB Saunders
-
Guyton AC, Hall JC: Body temperature, temperature regulation, and fever. In: Textbook of Medical Physiology, 10th Ed., Philadelphia, WB Saunders, 2000, pp 822-834
-
(2000)
Textbook of Medical Physiology
, pp. 822-834
-
-
Guyton, A.C.1
Hall, J.C.2
-
8
-
-
34447624328
-
Using a multi-method, user centred, prospective hazard analysis to assess care quality and patient safety in a care pathway
-
Dean JE, Hutchinson A, Escoto KH, Lawson R: Using a multi-method, user centred, prospective hazard analysis to assess care quality and patient safety in a care pathway. BMC Health Serv Res 7: 89-98, 2007
-
(2007)
BMC Health Serv Res
, vol.7
, pp. 89-98
-
-
Dean, J.E.1
Hutchinson, A.2
Escoto, K.H.3
Lawson, R.4
-
9
-
-
1842628881
-
The three critical issues I've learned in 23 years in clinical engineering
-
Pakaln A: The three critical issues I've learned in 23 years in clinical engineering. Biomed Instrum Technol 38: 119-121, 2004
-
(2004)
Biomed Instrum Technol
, vol.38
, pp. 119-121
-
-
Pakaln, A.1
-
10
-
-
67349151722
-
FMEA: A model for reducing medical errors
-
Chiozza ML, Ponzetti C: FMEA: A model for reducing medical errors. Clin Chim Acta 404: 75-78, 2009
-
(2009)
Clin Chim Acta
, vol.404
, pp. 75-78
-
-
Chiozza, M.L.1
Ponzetti, C.2
-
11
-
-
0035031850
-
Patient safety in end-stage renal disease: How do we create a safe environment?
-
Kliger AS, Diamond LH: Patient safety in end-stage renal disease: How do we create a safe environment? Adv Ren Replace Ther 8: 131-137, 2001
-
(2001)
Adv Ren Replace Ther
, vol.8
, pp. 131-137
-
-
Kliger, A.S.1
Diamond, L.H.2
-
12
-
-
77249107598
-
Clinical risk analysis with failure mode and effect analysis (FMEA) model in a dialysis unit
-
Bonfant G, Belfanti P, Paternoster G, Gabrielli D, Gaiter AM, Manes M, Molino A, Pellu V, Ponzetti C, Farina M, Nebiolo PE: Clinical risk analysis with failure mode and effect analysis (FMEA) model in a dialysis unit. J Nephrol 23: 111-118, 2010
-
(2010)
J Nephrol
, vol.23
, pp. 111-118
-
-
Bonfant, G.1
Belfanti, P.2
Paternoster, G.3
Gabrielli, D.4
Gaiter, A.M.5
Manes, M.6
Molino, A.7
Pellu, V.8
Ponzetti, C.9
Farina, M.10
Nebiolo, P.E.11
-
13
-
-
58849140431
-
Improvements in technology: A path to safer and more effective hemodialysis
-
Ward RA, Ronco C: Improvements in technology: A path to safer and more effective hemodialysis. Blood Purif 27: 6-10, 2009
-
(2009)
Blood Purif
, vol.27
, pp. 6-10
-
-
Ward, R.A.1
Ronco, C.2
-
14
-
-
78149311064
-
Practical matters: Neglected safety aspects in hemodialysis machines and their related problems
-
Available at
-
Polaschegg HD: Practical matters: Neglected safety aspects in hemodialysis machines and their related problems. Hemodialysis Horizons 65-68. Available at: http://www.aami. org/publications/hh/Neglected.Polaschegg.pdf
-
Hemodialysis Horizons
, pp. 65-68
-
-
Polaschegg, H.D.1
-
15
-
-
0035164667
-
Patients' safety and haemodialysis devices
-
Roy T: Patients' safety and haemodialysis devices. Nephrol Dial Transplant 16: 2138-2142, 2001
-
(2001)
Nephrol Dial Transplant
, vol.16
, pp. 2138-2142
-
-
Roy, T.1
-
16
-
-
33645313451
-
Intradialytic complications during hemodialysis
-
Davenport A: Intradialytic complications during hemodialysis. Hemodial Int 10: 162-167, 2006
-
(2006)
Hemodial Int
, vol.10
, pp. 162-167
-
-
Davenport, A.1
-
17
-
-
0242351688
-
Reduction of circulating microemboli in the subclavian vein of patients undergoing haemodialysis using pre-filled instead of dry dialysers
-
DOI 10.1093/ndt/gfg352
-
Droste DW, Beyna T, Frye B, Schulte V, Ringelstein EB, Schaefer RM: Reduction of circulating microemboli in the subclavian vein of patients undergoing haemodialysis using pre-filled instead of dry dialysers. Nephrol Dial Transplant 18: 2377-2381, 2003 (Pubitemid 37336828)
-
(2003)
Nephrology Dialysis Transplantation
, vol.18
, Issue.11
, pp. 2377-2381
-
-
Droste, D.W.1
Beyna, T.2
Frye, B.3
Schulte, V.4
Ringelstein, E.B.5
Schaefer, R.M.6
-
18
-
-
44649124363
-
Pathophysiology and clinical implications of microbubbles during hemodialysis
-
Barak M, Nakhoul F, Katz Y: Pathophysiology and clinical implications of microbubbles during hemodialysis. Semin Dial 21: 232-238, 2008
-
(2008)
Semin Dial
, vol.21
, pp. 232-238
-
-
Barak, M.1
Nakhoul, F.2
Katz, Y.3
-
19
-
-
33846969507
-
Air bubbles pass the security system of the dialysis device without alarming
-
Jonsson P, Karlsson L, Forsberg U, Gref M, Stegmayr C, Stegmayr B: Air bubbles pass the security system of the dialysis device without alarming. Artif Organs 31: 132-139, 2007
-
(2007)
Artif Organs
, vol.31
, pp. 132-139
-
-
Jonsson, P.1
Karlsson, L.2
Forsberg, U.3
Gref, M.4
Stegmayr, C.5
Stegmayr, B.6
-
20
-
-
34249310577
-
Development of air micro bubbles in the venous outlet line: An in vitro analysis of various air traps used for hemodialysis
-
Stegmayr CJ, Jonsson P, Forsberg U, Stegmayr BG: Development of air micro bubbles in the venous outlet line: An in vitro analysis of various air traps used for hemodialysis. Artif Organs 31: 483-488, 2007
-
(2007)
Artif Organs
, vol.31
, pp. 483-488
-
-
Stegmayr, C.J.1
Jonsson, P.2
Forsberg, U.3
Stegmayr, B.G.4
-
21
-
-
36448954295
-
Hemodialysis machine air detectors need not detect microbubbles
-
Polaschegg HD: Hemodialysis machine air detectors need not detect microbubbles. Artif Organs 31: 911-912, 2007
-
(2007)
Artif Organs
, vol.31
, pp. 911-912
-
-
Polaschegg, H.D.1
-
22
-
-
27144506167
-
Microbubbles: Pathophysiology and clinical implications
-
Barak M, Katz Y: Microbubbles: Pathophysiology and clinical implications. Chest 128: 2918-2932, 2005
-
(2005)
Chest
, vol.128
, pp. 2918-2932
-
-
Barak, M.1
Katz, Y.2
-
23
-
-
39049184426
-
A descriptive report of errors and adverse events in chronic hemodialysis units
-
Holley JL: A descriptive report of errors and adverse events in chronic hemodialysis units. Nephrol News Issues 20: 57-67, 2006
-
(2006)
Nephrol News Issues
, vol.20
, pp. 57-67
-
-
Holley, J.L.1
-
24
-
-
0025074420
-
Impact of high blood flows on vascular stability in haemodialysis
-
Ronco C, Feriani M, Chiaramonte S, Conz P, Brendolan A, Bragantini L, Milan M, Fabris A, Dell'Aquila R, Dissegna D, Crepaldi C, Agazia B, Finocchi G, De Dominicas E, La Greca G: Impact of high blood flows on vascular stability in haemodialysis. Nephrol Dial Transplant 5[Suppl 1]: 109-114, 1990
-
(1990)
Nephrol Dial Transplant
, vol.5
, Issue.SUPPL. 1
, pp. 109-114
-
-
Ronco, C.1
Feriani, M.2
Chiaramonte, S.3
Conz, P.4
Brendolan, A.5
Bragantini, L.6
Milan, M.7
Fabris, A.8
Dell'Aquila, R.9
Dissegna, D.10
Crepaldi, C.11
Agazia, B.12
Finocchi, G.13
De Dominicas, E.14
La Greca, G.15
-
27
-
-
72449197127
-
Hemostatic changes in patients with end stage renal disease undergoing hemodialysis
-
Rios DR, Carvalho MG, Lwaleed BA, Simões e Silva AC, Borges KB, Dusse LM: Hemostatic changes in patients with end stage renal disease undergoing hemodialysis. Clin Chim Acta 411: 135-139, 2010
-
(2010)
Clin Chim Acta
, vol.411
, pp. 135-139
-
-
Rios, D.R.1
Carvalho, M.G.2
Lwaleed, B.A.3
Simões E Silva, A.C.4
Borges, K.B.5
Dusse, L.M.6
-
30
-
-
0033886518
-
Red blood cell osmotic fragility confidence intervals: A definition by application of a mathematical model
-
Fernàndez-Alberti A, Fink NE: Red blood cell osmotic fragility confidence intervals: A definition by application of a mathematical model. Clin Chem Lab Med 38: 433-436, 2000 (Pubitemid 30599368)
-
(2000)
Clinical Chemistry and Laboratory Medicine
, vol.38
, Issue.5
, pp. 433-436
-
-
Fernandez-Alberti, A.1
Fink, N.E.2
-
31
-
-
0002191012
-
Water treatment for contemporary hemodialysis
-
4th Ed., edited by Jacobs C, Kjellstrand CM, Koch KM, Winchester JF, Dordrecht, The Netherlands, Kluwer Academic Publishers
-
Canaud BJ, Mion CM: Water treatment for contemporary hemodialysis. In: Replacement of Renal Function by Dialysis, 4th Ed., edited by Jacobs C, Kjellstrand CM, Koch KM, Winchester JF, Dordrecht, The Netherlands, Kluwer Academic Publishers, 1996, pp 231-255
-
(1996)
Replacement of Renal Function by Dialysis
, pp. 231-255
-
-
Canaud, B.J.1
Mion, C.M.2
-
32
-
-
77749317226
-
Water for haemodialysis and related therapies: Recent standards and emerging issues
-
Hoenich NA, Levin R, Ronco C: Water for haemodialysis and related therapies: Recent standards and emerging issues. Blood Purif 29: 81-85, 2010
-
(2010)
Blood Purif
, vol.29
, pp. 81-85
-
-
Hoenich, N.A.1
Levin, R.2
Ronco, C.3
-
33
-
-
84973892657
-
-
ANSI/AAMI RD 62: Arlington, VA, Association for the Advancement of Medical Instrumentation
-
ANSI/AAMI RD 62: Water Treatment Equipment for Hemodialysis Applications, Arlington, VA, Association for the Advancement of Medical Instrumentation, 2006
-
(2006)
Water Treatment Equipment for Hemodialysis Applications
-
-
-
34
-
-
77951625251
-
Disinfection of the hospital water supply: A hidden risk to dialysis patients
-
Hoenich NA: Disinfection of the hospital water supply: A hidden risk to dialysis patients. Crit Care 13: 1007, 2009
-
(2009)
Crit Care
, vol.13
, pp. 1007
-
-
Hoenich, N.A.1
-
35
-
-
0035147483
-
Mortality risk by hemodialyzer reuse practice and dialyzer membrane characteristics: Results from the USRDS Dialysis Morbidity and Mortality Study
-
Port FK, Wolfe RA, Hulbert-Shearon TE, Daugirdas JT, Agodoa LY, Jones C, Orzol SM, Held PJ: Mortality risk by hemodialyzer reuse practice and dialyzer membrane characteristics: Results from the USRDS Dialysis Morbidity and Mortality Study. Am J Kidney Dis 37: 276-286, 2001
-
(2001)
Am J Kidney Dis
, vol.37
, pp. 276-286
-
-
Port, F.K.1
Wolfe, R.A.2
Hulbert-Shearon, T.E.3
Daugirdas, J.T.4
Agodoa, L.Y.5
Jones, C.6
Orzol, S.M.7
Held, P.J.8
-
36
-
-
78149322562
-
-
ANSI/AAMI RD 47: Arlington, Association for the Advancement of Medical Instrumentation
-
ANSI/AAMI RD 47: Reprocessing of Hemodialyzers, Arlington, Association for the Advancement of Medical Instrumentation, 2008
-
(2008)
Reprocessing of Hemodialyzers
-
-
-
37
-
-
70350033551
-
Red blood cell damage from extracorporeal circulation in hemodialysis
-
Polaschegg HD: Red blood cell damage from extracorporeal circulation in hemodialysis. Semin Dial 22: 524-531, 2009
-
(2009)
Semin Dial
, vol.22
, pp. 524-531
-
-
Polaschegg, H.D.1
-
38
-
-
0035957964
-
Recommendations for preventing transmission of infections among chronic hemodialysis patients
-
Recommendations for preventing transmission of infections among chronic hemodialysis patients. MMWR Recomm Rep 50: 1-43, 2001
-
(2001)
MMWR Recomm Rep
, vol.50
, pp. 1-43
-
-
-
39
-
-
42149100485
-
The microbial world and fluids in dialysis
-
Nystrand R: The microbial world and fluids in dialysis. Biomed Instrum Technol 42: 150-159, 2008
-
(2008)
Biomed Instrum Technol
, vol.42
, pp. 150-159
-
-
Nystrand, R.1
-
41
-
-
33144472463
-
-
ANSI/AAMI RD 52: Arlington, Association for the Advancement of Medical Instrumentation
-
ANSI/AAMI RD 52: Dialysate for Hemodialysis, Arlington, Association for the Advancement of Medical Instrumentation, 2004
-
(2004)
Dialysate for Hemodialysis
-
-
-
42
-
-
84900438733
-
Complications of bioincompatibility of hemodialysis membranes
-
edited by Lameire N, Mehta RL, New York, Marcel Dekker
-
Pereira BJ, Cheung AK: Complications of bioincompatibility of hemodialysis membranes. In: Complications in Dialysis, edited by Lameire N, Mehta RL, New York, Marcel Dekker, 2000, pp 41-68
-
(2000)
Complications in Dialysis
, pp. 41-68
-
-
Pereira, B.J.1
Cheung, A.K.2
-
43
-
-
0032908307
-
Defining the microbiological quality of dialysis fluid
-
Ledebo I, Nystrand R: Defining the microbiological quality of dialysis fluid. Artif Organs 23: 37-43, 1999
-
(1999)
Artif Organs
, vol.23
, pp. 37-43
-
-
Ledebo, I.1
Nystrand, R.2
-
44
-
-
0034839085
-
Effects of ultra-pure dialysis fluid on nutritional status and inflammatory parameters
-
Schiffl H, Lang SM, Stratakis D, Fischer R: Effects of ultra-pure dialysis fluid on nutritional status and inflammatory parameters. Nephrol Dial Transplant 16: 1863-1869, 2001
-
(2001)
Nephrol Dial Transplant
, vol.16
, pp. 1863-1869
-
-
Schiffl, H.1
Lang, S.M.2
Stratakis, D.3
Fischer, R.4
-
45
-
-
0001871846
-
Hemodialysis fluid composition
-
4th Ed., edited by Jacobs C, Kjellstrand CM, Koch KM, Winchester JF, Dordrecht, The Netherlands, Kluwer Academic Publishers
-
Ronco C, Fabris A, Feriani M: Hemodialysis fluid composition. In: Replacement of Renal Function by Dialysis, 4th Ed., edited by Jacobs C, Kjellstrand CM, Koch KM, Winchester JF, Dordrecht, The Netherlands, Kluwer Academic Publishers, 1996, pp 256-276
-
(1996)
Replacement of Renal Function by Dialysis
, pp. 256-276
-
-
Ronco, C.1
Fabris, A.2
Feriani, M.3
-
46
-
-
33745285983
-
Clinical practice guidelines for hemodialysis adequacy: Update 2006
-
Hemodialysis Adequacy 2006 Work Group: Clinical practice guidelines for hemodialysis adequacy: Update 2006. Am J Kidney Dis 48[Suppl 1]: S2-S90, 2006
-
(2006)
Am J Kidney Dis
, vol.48
, Issue.SUPPL. 1
-
-
|