Volumn 31, Issue 2, 2007, Pages 132-139

Air bubbles pass the security system of the dialysis device without alarming

Author keywords

Air chamber; Air trap; Hemodialysis; Microbubbles; Regulations; Safety; Safety risk

Indexed keywords

AIR; HEMODIALYZERS; SAFETY ENGINEERING; ULTRASONICS;

EID: 33846969507     PISSN: 0160564X     EISSN: 15251594     Source Type: Journal    
DOI: 10.1111/j.1525-1594.2007.00352.x     Document Type: Article
Times cited : (37)

References (18)
  • 2
    • 33846957404 scopus 로고    scopus 로고
    • International Electrotechnical Commission (IEC). IEC601-2-16 3.6: The following is not regarded as a single fault condition: air in the extracorporeal circuit. *51.106 air infusion a) The equipment shall include a protective system to protect the patient from air-infusion which may cause a safety hazard. Particular Requirements for the Safety of Haemodialysis, Haemodiafiltration and Haemofiltration Equipment. Geneva, Switzerland: Central Office of the IEC, 1998;8, 15.
    • International Electrotechnical Commission (IEC). IEC601-2-16 3.6: The following is not regarded as a single fault condition: air in the extracorporeal circuit. *51.106 air infusion a) The equipment shall include a protective system to protect the patient from air-infusion which may cause a safety hazard. Particular Requirements for the Safety of Haemodialysis, Haemodiafiltration and Haemofiltration Equipment. Geneva, Switzerland: Central Office of the IEC, 1998;8, 15.
  • 3
    • 33846980833 scopus 로고    scopus 로고
    • Infusion of air contaminated blood through a central dialysis catheter by mistake
    • Report, SOSFS1991:34 19930622 dnr:5287/1993. Socialstyrelsen, Sweden
    • Socialstyrelsen. Infusion of air contaminated blood through a central dialysis catheter by mistake. Report - SOSFS1991:34 19930622 dnr:5287/1993. Socialstyrelsen, Sweden.
    • Socialstyrelsen1
  • 6
    • 0021876957 scopus 로고
    • Gas bubble detection in fluid lines by means of pulsed Doppler ultrasound
    • Hatteland K, Semb BK. Gas bubble detection in fluid lines by means of pulsed Doppler ultrasound. Scand J Thorac Cardiovasc Surg 1985;19:119-23.
    • (1985) Scand J Thorac Cardiovasc Surg , vol.19 , pp. 119-123
    • Hatteland, K.1    Semb, B.K.2
  • 7
    • 24044484898 scopus 로고    scopus 로고
    • Hemodialysis machines and monitors
    • Hörl WH, Koch KM, Lindsay RM, Ronco C, Winchester JF, eds, London, England: Kluwer Academic Publishers
    • Polaschegg H-D, Levin NW. Hemodialysis machines and monitors. In: Hörl WH, Koch KM, Lindsay RM, Ronco C, Winchester JF, eds. Replacement of Renal Function By Dialysis. London, England: Kluwer Academic Publishers, 2004;325-449.
    • (2004) Replacement of Renal Function By Dialysis , pp. 325-449
    • Polaschegg, H.-D.1    Levin, N.W.2
  • 8
    • 33846943374 scopus 로고    scopus 로고
    • International Electrotechnical Commission (IEC). Medical electrical equipment - part 2-24: particular requirements for the safety of infusion pumps and controllers. IEC 60601-2-24. Rationale to 51.104.
    • International Electrotechnical Commission (IEC). Medical electrical equipment - part 2-24: particular requirements for the safety of infusion pumps and controllers. IEC 60601-2-24. Rationale to 51.104.
  • 9
    • 0242351688 scopus 로고    scopus 로고
    • Reduction of circulating microemboli in the subclavian vein of patients undergoing haemodialysis using pre-filled instead of dry dialysers
    • Droste DW, Beyna T, Frye B, Schulte V, Ringelstein EB, Schaefer RM. Reduction of circulating microemboli in the subclavian vein of patients undergoing haemodialysis using pre-filled instead of dry dialysers. Nephrol Dial Transplant 2003;18:2377-81.
    • (2003) Nephrol Dial Transplant , vol.18 , pp. 2377-2381
    • Droste, D.W.1    Beyna, T.2    Frye, B.3    Schulte, V.4    Ringelstein, E.B.5    Schaefer, R.M.6
  • 10
    • 0036200670 scopus 로고    scopus 로고
    • Detection of microemboli in the subclavian vein of patients undergoing haemodialysis and haemodiafiltration using pulsed Doppler ultrasound
    • Droste DW, Kuhne K, Schaefer RM, Ringelstein EB. Detection of microemboli in the subclavian vein of patients undergoing haemodialysis and haemodiafiltration using pulsed Doppler ultrasound. Nephrol Dial Transplant 2002;17:462-6.
    • (2002) Nephrol Dial Transplant , vol.17 , pp. 462-466
    • Droste, D.W.1    Kuhne, K.2    Schaefer, R.M.3    Ringelstein, E.B.4
  • 12
    • 0021235308 scopus 로고
    • Doppler ultrasonic detection of particulate release during hemodialysis with cellulose hollow-fiber and sorbent suspension reciprocating dialyzers
    • Badylak SF, Ash SR, Thornhill JA, Carr DJ. Doppler ultrasonic detection of particulate release during hemodialysis with cellulose hollow-fiber and sorbent suspension reciprocating dialyzers. Artif Organs 1984;8:220-3.
    • (1984) Artif Organs , vol.8 , pp. 220-223
    • Badylak, S.F.1    Ash, S.R.2    Thornhill, J.A.3    Carr, D.J.4
  • 13
    • 33847000176 scopus 로고    scopus 로고
    • The sensor in the venous chamber does not prevent passage of air bubbles during hemodialysis
    • Stegmayr B, Forsberg U, Jonsson P, Stegmayr C. The sensor in the venous chamber does not prevent passage of air bubbles during hemodialysis. Artif Organs 2007;31:162-5.
    • (2007) Artif Organs , vol.31 , pp. 162-165
    • Stegmayr, B.1    Forsberg, U.2    Jonsson, P.3    Stegmayr, C.4
  • 15
    • 0026585294 scopus 로고
    • Granulocyte elastase, beta-thromboglobulin, and C3d during acetate or bicarbonate hemodialysis with Hemophan compared to a cellulose acetate membrane
    • Stegmayr BG, Esbensen K, Gutierrez A, Lundberg L, Nielsen B, Stroemsaeter CE, Wehle B. Granulocyte elastase, beta-thromboglobulin, and C3d during acetate or bicarbonate hemodialysis with Hemophan compared to a cellulose acetate membrane. Int J Artif Organs 1992;15:10-8.
    • (1992) Int J Artif Organs , vol.15 , pp. 10-18
    • Stegmayr, B.G.1    Esbensen, K.2    Gutierrez, A.3    Lundberg, L.4    Nielsen, B.5    Stroemsaeter, C.E.6    Wehle, B.7
  • 17
    • 27144506167 scopus 로고    scopus 로고
    • Microbubbles: Pathophysiology and clinical implications
    • Barak M, Katz Y. Microbubbles: pathophysiology and clinical implications. Chest 2005;128:2918-32.
    • (2005) Chest , vol.128 , pp. 2918-2932
    • Barak, M.1    Katz, Y.2
  • 18
    • 21644431566 scopus 로고    scopus 로고
    • Overproduction of reactive oxygen species in end-stage renal disease patients: A potential component of hemodialysis-associated inflammation
    • Morena M, Delbosc S, Dupuy AM, Canaud B, Cristol JP.. Overproduction of reactive oxygen species in end-stage renal disease patients: a potential component of hemodialysis-associated inflammation. Hemodial Int 2005;9:37-46.
    • (2005) Hemodial Int , vol.9 , pp. 37-46
    • Morena, M.1    Delbosc, S.2    Dupuy, A.M.3    Canaud, B.4    Cristol, J.P.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.