메뉴 건너뛰기




Volumn 55, Issue 17, 2010, Pages 5029-5044

An oscillating sweeping gap test for VMAT quality assurance

Author keywords

[No Author keywords available]

Indexed keywords

ALGORITHM; ARTICLE; COMPUTER ASSISTED RADIOTHERAPY; EVALUATION; FILM DOSIMETER; HEALTH CARE QUALITY; INSTRUMENTATION; METHODOLOGY; RADIATION DOSE; RADIOMETRY; REPRODUCIBILITY; SENSITIVITY AND SPECIFICITY;

EID: 78149289968     PISSN: 00319155     EISSN: 13616560     Source Type: Journal    
DOI: 10.1088/0031-9155/55/17/010     Document Type: Article
Times cited : (16)

References (13)
  • 1
    • 78149348307 scopus 로고    scopus 로고
    • A novel approach to machine specific QA for volumetric modulated arc therapy
    • Cao D, Rao M, Chen F, Ye J, Luan S and Shepard D 2009 A novel approach to machine specific QA for volumetric modulated arc therapy Med. Phys. 36 2571
    • (2009) Med. Phys. , vol.36 , pp. 2571
    • Cao, D.1    Rao, M.2    Chen, F.3    Ye, J.4    Luan, S.5    Shepard, D.6
  • 2
    • 0029931223 scopus 로고    scopus 로고
    • Testing of dynamic multileaf collimation
    • Chui C S, Spirou S and LoSasso T 1996 Testing of dynamic multileaf collimation Med. Phys. 23 635-41
    • (1996) Med. Phys. , vol.23 , pp. 635-641
    • Chui, C.S.1    Spirou, S.2    LoSasso, T.3
  • 4
    • 41849145210 scopus 로고    scopus 로고
    • An independent dose calculation algorithm for MLC-based radiotherapy including the spatial dependence of MLC transmission
    • Lorenz F, Nalichowski A, Rosca F, Killoran J, Wenz F and Zygmanski P 2008 An independent dose calculation algorithm for MLC-based radiotherapy including the spatial dependence of MLC transmission Phys. Med. Biol. 53 557-73
    • (2008) Phys. Med. Biol. , vol.53 , pp. 557-573
    • Lorenz, F.1    Nalichowski, A.2    Rosca, F.3    Killoran, J.4    Wenz, F.5    Zygmanski, P.6
  • 5
    • 54949156104 scopus 로고    scopus 로고
    • Evaluation of a new IR-guided system for mechanical QA of linear accelerators
    • Lyatskaya Y, Kadam D, Levitsky G, Hacker F and Chin L 2008 Evaluation of a new IR-guided system for mechanical QA of linear accelerators Med. Phys. 35 4816-23
    • (2008) Med. Phys. , vol.35 , pp. 4816-4823
    • Lyatskaya, Y.1    Kadam, D.2    Levitsky, G.3    Hacker, F.4    Chin, L.5
  • 6
    • 0031049653 scopus 로고    scopus 로고
    • A quality assurance procedure for the Varian multi-leaf collimator
    • Mubata C D, Childs P and Bidmead A M 1997 A quality assurance procedure for the Varian multi-leaf collimator Phys. Med. Biol. 42 423-31
    • (1997) Phys. Med. Biol. , vol.42 , pp. 423-431
    • Mubata, C.D.1    Childs, P.2    Bidmead, A.M.3
  • 7
    • 33744808579 scopus 로고    scopus 로고
    • An MLC-based linac QA procedure for the characterization of radiation isocenter and room lasers position
    • Rosca F, Lorentz F, Hacker F, Chin L and Zygmanski P 2006 An MLC-based linac QA procedure for the characterization of radiation isocenter and room lasers position Med. Phys. 33 1780-7
    • (2006) Med. Phys. , vol.33 , pp. 1780-1787
    • Rosca, F.1    Lorentz, F.2    Hacker, F.3    Chin, L.4    Zygmanski, P.5
  • 8
    • 44449088459 scopus 로고    scopus 로고
    • An EPID response calculation algorithm using spatial beam characteristics of primary, head-scattered and MLC-transmitted radiation
    • Rosca F and Zygmanski P 2008 An EPID response calculation algorithm using spatial beam characteristics of primary, head-scattered and MLC-transmitted radiation Med. Phys. 35 2224-34
    • (2008) Med. Phys. , vol.35 , pp. 2224-2234
    • Rosca, F.1    Zygmanski, P.2
  • 10
    • 58149236918 scopus 로고    scopus 로고
    • A volumetric-modulated arc therapy using sub-conformal dynamic arc with a monotonic dynamic multileaf collimator modulation
    • Zygmanski P, Hoegele W, Cormack R, Chin L and Loeschel R 2008 A volumetric-modulated arc therapy using sub-conformal dynamic arc with a monotonic dynamic multileaf collimator modulation Phys. Med. Biol. 53 6395-417
    • (2008) Phys. Med. Biol. , vol.53 , pp. 6395-6417
    • Zygmanski, P.1    Hoegele, W.2    Cormack, R.3    Chin, L.4    Loeschel, R.5
  • 11
    • 0035185056 scopus 로고    scopus 로고
    • Method of identifying dynamic multileaf collimator irradiation that is highly sensitive to a systematic MLC calibration error
    • Zygmanski P and Kung J H 2001 Method of identifying dynamic multileaf collimator irradiation that is highly sensitive to a systematic MLC calibration error Med. Phys. 28 2220-6
    • (2001) Med. Phys. , vol.28 , pp. 2220-2226
    • Zygmanski, P.1    Kung, J.H.2
  • 12
    • 0142057574 scopus 로고    scopus 로고
    • Dependence of fluence errors in dynamic IMRT on leaf-positional errors varying with time and leaf number
    • Zygmanski P, Kung J H, Jiang S B and Chin L 2003 Dependence of fluence errors in dynamic IMRT on leaf-positional errors varying with time and leaf number Med. Phys. 30 2736-49
    • (2003) Med. Phys. , vol.30 , pp. 2736-2749
    • Zygmanski, P.1    Kung, J.H.2    Jiang, S.B.3    Chin, L.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.