-
1
-
-
85024401456
-
-
Boyer A, Biggs P, Galvin J, et al., for the American Association of Physicists in Medicine (AAPM). Basic applications of multileaf collimators. AAPM report no. 72. Madison (WI): Medical Physics Publishing; 2001. 54 p.
-
Boyer A, Biggs P, Galvin J, et al., for the American Association of Physicists in Medicine (AAPM). Basic applications of multileaf collimators. AAPM report no. 72. Madison (WI): Medical Physics Publishing; 2001. 54 p.
-
-
-
-
2
-
-
0031762329
-
Physical and dosimetric aspects of a multileaf collimation system used in the dynamic mode for implementing intensity modulated radiotherapy
-
LoSasso T, Chui CS, Ling CC. Physical and dosimetric aspects of a multileaf collimation system used in the dynamic mode for implementing intensity modulated radiotherapy. Med Phys. 1998;25(10):1919-1927.
-
(1998)
Med Phys
, vol.25
, Issue.10
, pp. 1919-1927
-
-
LoSasso, T.1
Chui, C.S.2
Ling, C.C.3
-
3
-
-
0035661179
-
A Monte Carlo study of radiation transport through multileaf collimators
-
Kim JO, Siebers JV, Keal PJ, Arnfield MR, Mohan R. A Monte Carlo study of radiation transport through multileaf collimators. Med Phys. 2001;28(12):2497-2505.
-
(2001)
Med Phys
, vol.28
, Issue.12
, pp. 2497-2505
-
-
Kim, J.O.1
Siebers, J.V.2
Keal, P.J.3
Arnfield, M.R.4
Mohan, R.5
-
4
-
-
0033735315
-
A method for determining multileaf collimator transmission and scatter for dynamic intensity modulated radiotherapy
-
Arnfield MR, Siebers JV, Kim JO, Wu Q, Keal PJ, Mohan R. A method for determining multileaf collimator transmission and scatter for dynamic intensity modulated radiotherapy Med Phys. 2000;27(10):2231-2241.
-
(2000)
Med Phys
, vol.27
, Issue.10
, pp. 2231-2241
-
-
Arnfield, M.R.1
Siebers, J.V.2
Kim, J.O.3
Wu, Q.4
Keal, P.J.5
Mohan, R.6
-
6
-
-
0035142023
-
Modeling the extrafocal radiation and monitor chamber backscatter for photon beam dose calculation
-
Jiang S, Boyer A, Ma CM. Modeling the extrafocal radiation and monitor chamber backscatter for photon beam dose calculation Med Phys. 2001;28(1):55-66.
-
(2001)
Med Phys
, vol.28
, Issue.1
, pp. 55-66
-
-
Jiang, S.1
Boyer, A.2
Ma, C.M.3
-
7
-
-
0004018860
-
-
Philadelphia PA, Institute of Physics Publishing;, 435 p
-
Webb S. Intensity-modulated radiation therapy. Philadelphia (PA): Institute of Physics Publishing; 2001. 435 p.
-
(2001)
Intensity-modulated radiation therapy
-
-
Webb, S.1
-
8
-
-
31844434458
-
MCNPX simulation of a multileaf collimator
-
Pönisch F, Titt U, Kry SF, Vassiliev ON, Mohan R. MCNPX simulation of a multileaf collimator. Med Phys. 2006;33(2):402-404.
-
(2006)
Med Phys
, vol.33
, Issue.2
, pp. 402-404
-
-
Pönisch, F.1
Titt, U.2
Kry, S.F.3
Vassiliev, O.N.4
Mohan, R.5
-
9
-
-
33644621832
-
Development and commissioning of a multileaf collimator model in Monte Carlo dose calculations for intensity-modulated radiation therapy
-
Jang SY, Vassiliev ON, Liu HH, Mohan R, Siebers JV. Development and commissioning of a multileaf collimator model in Monte Carlo dose calculations for intensity-modulated radiation therapy. Med Phys. 2006;33(3):770-781.
-
(2006)
Med Phys
, vol.33
, Issue.3
, pp. 770-781
-
-
Jang, S.Y.1
Vassiliev, O.N.2
Liu, H.H.3
Mohan, R.4
Siebers, J.V.5
-
10
-
-
33745657856
-
Dose uncertainty due to aperture effects in dynamic fields
-
Higgins PD, Alaei P. Dose uncertainty due to aperture effects in dynamic fields. Med Phys. 2006;33(7):2418-2425.
-
(2006)
Med Phys
, vol.33
, Issue.7
, pp. 2418-2425
-
-
Higgins, P.D.1
Alaei, P.2
-
11
-
-
0035185056
-
Method of identifying dynamic multileaf collimator irradiation that is highly sensitive to a systematic MLC calibration error
-
Zygmanski P, Kung JH. Method of identifying dynamic multileaf collimator irradiation that is highly sensitive to a systematic MLC calibration error. Med Phys. 2001;28(11):2220-2226.
-
(2001)
Med Phys
, vol.28
, Issue.11
, pp. 2220-2226
-
-
Zygmanski, P.1
Kung, J.H.2
-
12
-
-
85024959308
-
Maximum MLC opening effect in dynamic delivery of IMRT: Leaf-positional analysis
-
Zygmanski P, Hacker F, Friesen S, Rodenbush R, Lu HM, Chin L. Maximum MLC opening effect in dynamic delivery of IMRT: leaf-positional analysis. J Clin Med Phys. 2005;6:33-43
-
(2005)
J Clin Med Phys
, vol.6
, pp. 33-43
-
-
Zygmanski, P.1
Hacker, F.2
Friesen, S.3
Rodenbush, R.4
Lu, H.M.5
Chin, L.6
-
13
-
-
0031830588
-
A pencil-beam photon dose algorithm for stereotactic radiosurgery using a miniature multileaf collimator
-
Dong L, Shiu A, Tung S, Hogstrom K. A pencil-beam photon dose algorithm for stereotactic radiosurgery using a miniature multileaf collimator. Med Phys. 1998;25(6):841-850.
-
(1998)
Med Phys
, vol.25
, Issue.6
, pp. 841-850
-
-
Dong, L.1
Shiu, A.2
Tung, S.3
Hogstrom, K.4
-
14
-
-
0030770288
-
Quality control of measured X-ray beam data
-
Bjärngard BE, Vadash P, Ceberg CP. Quality control of measured X-ray beam data. Med Phys. 1997;24(9):1441-1444.
-
(1997)
Med Phys
, vol.24
, Issue.9
, pp. 1441-1444
-
-
Bjärngard, B.E.1
Vadash, P.2
Ceberg, C.P.3
-
15
-
-
0034977515
-
Modeling the output ratio in air for megavoltage photon beams
-
Zhu TC, Bjärngard BE, Xiao Y, Yang CJ. Modeling the output ratio in air for megavoltage photon beams. Med Phys. 2001;28(6):925-937.
-
(2001)
Med Phys
, vol.28
, Issue.6
, pp. 925-937
-
-
Zhu, T.C.1
Bjärngard, B.E.2
Xiao, Y.3
Yang, C.J.4
-
16
-
-
0344950539
-
Head scatter off-axis for megavoltage X rays
-
Zhu T, Bjärngard BE. Head scatter off-axis for megavoltage X rays. Med Phys. 2003;30(4):533-543.
-
(2003)
Med Phys
, vol.30
, Issue.4
, pp. 533-543
-
-
Zhu, T.1
Bjärngard, B.E.2
-
17
-
-
4644253384
-
Output ratio in air for MLC shaped irregular fields
-
Zhu TC, Bjärngard BE, Xiao Y, Bieda M. Output ratio in air for MLC shaped irregular fields. Med Phys. 2004;31(9):2480-2490.
-
(2004)
Med Phys
, vol.31
, Issue.9
, pp. 2480-2490
-
-
Zhu, T.C.1
Bjärngard, B.E.2
Xiao, Y.3
Bieda, M.4
-
19
-
-
85024398540
-
-
Eclipse Manual. Palo Alto (CA): Varian Medical Systems; 2004. 45 p.
-
Eclipse Manual. Palo Alto (CA): Varian Medical Systems; 2004. 45 p.
-
-
-
-
20
-
-
1142275406
-
Tongue-and-groove effect in intensity modulated radiotherapy with static multileaf collimator fields
-
Que W, Kung J, Dai J. "Tongue-and-groove" effect in intensity modulated radiotherapy with static multileaf collimator fields. Phys Med Biol. 2004;49(3):399-405.
-
(2004)
Phys Med Biol
, vol.49
, Issue.3
, pp. 399-405
-
-
Que, W.1
Kung, J.2
Dai, J.3
|