1
-
-
0036604074
-
Heat pumps-status and trends in Asia and the Pacific
-
T. Nishimura Heat pumps-status and trends in Asia and the Pacific Int. J. Refrigeration 25 4 2002 405 413
-
(2002)
Int. J. Refrigeration
, vol.25
, Issue.4
, pp. 405-413
-
-
Nishimura, T.1
-
2
-
-
1642618953
-
Applying grey forecasting to predicting the operating energy performance of air cooled water chillers
-
Y.Q. Jiang, Y. Yang, S.M. Deng, and Z.L. Ma Applying grey forecasting to predicting the operating energy performance of air cooled water chillers Int. J. Refrigeration 27 4 2004 385 392
-
(2004)
Int. J. Refrigeration
, vol.27
, Issue.4
, pp. 385-392
-
-
Jiang, Y.Q.1
Yang, Y.2
Deng, S.M.3
Ma, Z.L.4
-
3
-
-
40249090612
-
Defrost cycle performance for a circular shape evaporator air source heat pump
-
N. Hewitt, and M.J. Huang Defrost cycle performance for a circular shape evaporator air source heat pump Int. J. Refrigeration 31 3 2008 444 452
-
(2008)
Int. J. Refrigeration
, vol.31
, Issue.3
, pp. 444-452
-
-
Hewitt, N.1
Huang, M.J.2
-
4
-
-
0025840669
-
Effect of short-tube orifice size on the performance of an air source heat pump during the reverse-cycle defrost
-
D.L. O'Neal, K. Peterson, and N.K. Anand Effect of short-tube orifice size on the performance of an air source heat pump during the reverse-cycle defrost Int. J. Refrigeration 14 1 1991 52 57
-
(1991)
Int. J. Refrigeration
, vol.14
, Issue.1
, pp. 52-57
-
-
O'Neal, D.L.1
Peterson, K.2
Anand, N.K.3
-
5
-
-
4344566422
-
Experiment investigation of reverse-cycle defrosting methods on air source heat pump with TXV as the throttle regulator
-
Y.J. Ding, G.Y. Ma, Q.H. Chai, and Y. Jiang Experiment investigation of reverse-cycle defrosting methods on air source heat pump with TXV as the throttle regulator Int. J. Refrigeration 27 6 2004 671 678
-
(2004)
Int. J. Refrigeration
, vol.27
, Issue.6
, pp. 671-678
-
-
Ding, Y.J.1
Ma, G.Y.2
Chai, Q.H.3
Jiang, Y.4
-
6
-
-
33244463052
-
The application of photo-coupler for frost detecting in an air-source heat pump
-
J.S. Byun, C.D. Jeon, J.H. Jung, and J.H. Lee The application of photo-coupler for frost detecting in an air-source heat pump Int. J. Refrigeration 29 2 2006 191 198
-
(2006)
Int. J. Refrigeration
, vol.29
, Issue.2
, pp. 191-198
-
-
Byun, J.S.1
Jeon, C.D.2
Jung, J.H.3
Lee, J.H.4
-
7
-
-
2942749983
-
A study on the performance of the airside heat exchanger under frosting in air source heat pump water heater/chiller unit
-
Y. Yao, Y.Q. Jiang, S.M. Deng, and Z.L. Ma A study on the performance of the airside heat exchanger under frosting in air source heat pump water heater/chiller unit Int. J. Heat Mass Transfer 47 17-18 2004 3745 3756
-
(2004)
Int. J. Heat Mass Transfer
, vol.47
, Issue.1718
, pp. 3745-3756
-
-
Yao, Y.1
Jiang, Y.Q.2
Deng, S.M.3
Ma, Z.L.4
-
8
-
-
0027883588
-
An idealized model of reversed-cycle hot gas defrosting of evaporators - Part 1: Theory
-
K.I. Krakow, L. Yan, and S. Lin An idealized model of reversed-cycle hot gas defrosting of evaporators - part 1: theory ASHRAE Trans. 99 2 1993 317 338
-
(1993)
ASHRAE Trans.
, vol.99
, Issue.2
, pp. 317-338
-
-
Krakow, K.I.1
Yan, L.2
Lin, S.3
-
9
-
-
0037400198
-
Dynamic simulation of air source heat pump during hot-gas defrost
-
Z.Q. Liu, G.F. Tang, and F.Y. Zhao Dynamic simulation of air source heat pump during hot-gas defrost Appl. Therm. Eng. 23 6 2003 675 685
-
(2003)
Appl. Therm. Eng.
, vol.23
, Issue.6
, pp. 675-685
-
-
Liu, Z.Q.1
Tang, G.F.2
Zhao, F.Y.3
-
10
-
-
0000209811
-
Refrigeration system dynamics during the reverse-cycle defrost
-
D.L. O'Neal, K. Peterson, N.K. Anand, and J.S. Schliesing Refrigeration system dynamics during the reverse-cycle defrost ASHRAE Trans. 95 1 1989 689 698
-
(1989)
ASHRAE Trans.
, vol.95
, Issue.1
, pp. 689-698
-
-
O'Neal, D.L.1
Peterson, K.2
Anand, N.K.3
Schliesing, J.S.4
-
11
-
-
0029250487
-
Defrost cycle performance for an air source heat pump with a scroll and a reciprocating compressor
-
V. Payne, and D.L. O'Neal Defrost cycle performance for an air source heat pump with a scroll and a reciprocating compressor Int. J. Refrigeration 18 5 1995 107 112
-
(1995)
Int. J. Refrigeration
, vol.18
, Issue.5
, pp. 107-112
-
-
Payne, V.1
O'Neal, D.L.2
-
12
-
-
10044231379
-
Effects of fan-starting methods on the reverse-cycle defrost performance of an air-to-water heat pump
-
D. Huang, X.L. Yuan, and X.Q. Zhang Effects of fan-starting methods on the reverse-cycle defrost performance of an air-to-water heat pump Int. J. Refrigeration 27 8 2004 869 875
-
(2004)
Int. J. Refrigeration
, vol.27
, Issue.8
, pp. 869-875
-
-
Huang, D.1
Yuan, X.L.2
Zhang, X.Q.3
-
13
-
-
78049433943
-
-
Code for Design of Heating, Ventilation, and Air Conditioning, GB50019-2003, National Standard of the People's Republic of China
-
Code for Design of Heating, Ventilation, and Air Conditioning, GB50019-2003, National Standard of the People's Republic of China.
-
-
-
-
15
-
-
44149087090
-
Thermal cycle testing of calcium chloride hexahydrate as a possible PCM for latent heat storage
-
V.V. Tyagi, and D. Buddhi Thermal cycle testing of calcium chloride hexahydrate as a possible PCM for latent heat storage Sol. Energy Mater. Sol. Cells 92 2008 891 899
-
(2008)
Sol. Energy Mater. Sol. Cells
, vol.92
, pp. 891-899
-
-
Tyagi, V.V.1
Buddhi, D.2
|