메뉴 건너뛰기




Volumn 31, Issue 3, 2008, Pages 444-452

Defrost cycle performance for a circular shape evaporator air source heat pump

Author keywords

Air water; Frosting; Heat pump; House; Performance; Survey

Indexed keywords

AIR; ATMOSPHERIC HUMIDITY; HEAT PUMP SYSTEMS;

EID: 40249090612     PISSN: 01407007     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.ijrefrig.2007.07.010     Document Type: Article
Times cited : (68)

References (12)
  • 1
    • 2142800708 scopus 로고
    • Effects of outdoor coil fan pre-start on pressure transients during the reverse cycle defrost of heat pump
    • Anand N.K., Schliesing J.S., O'Neal D.L., and Peterson K.T. Effects of outdoor coil fan pre-start on pressure transients during the reverse cycle defrost of heat pump. ASHRAE Trans. 95 2 (1989) 699-704
    • (1989) ASHRAE Trans. , vol.95 , Issue.2 , pp. 699-704
    • Anand, N.K.1    Schliesing, J.S.2    O'Neal, D.L.3    Peterson, K.T.4
  • 2
    • 40249086206 scopus 로고    scopus 로고
    • Anon., 2004. EN14511: air conditioners, liquid chilling packages and heat pumps with electrically driven compressors for space heating and cooling (Parts 1-4).
    • Anon., 2004. EN14511: air conditioners, liquid chilling packages and heat pumps with electrically driven compressors for space heating and cooling (Parts 1-4).
  • 3
    • 33244463052 scopus 로고    scopus 로고
    • The application of photo-coupler for frost detecting in an air-source heat pump
    • Byun J.-S., Jeon C.-D., Jung J.-H., and Lee J. The application of photo-coupler for frost detecting in an air-source heat pump. Int. J. Refrigeration 29 (2006) 191-198
    • (2006) Int. J. Refrigeration , vol.29 , pp. 191-198
    • Byun, J.-S.1    Jeon, C.-D.2    Jung, J.-H.3    Lee, J.4
  • 4
    • 40249115950 scopus 로고    scopus 로고
    • DTI & National Statistics, 2001. Energy-Consumption in the UK.
    • DTI & National Statistics, 2001. Energy-Consumption in the UK.
  • 5
    • 10044231379 scopus 로고    scopus 로고
    • Effects of fan-starting methods on the reverse-cycle defrost performance of an air-to-water heat pump
    • Huang D., Yuan X., and Zhang X. Effects of fan-starting methods on the reverse-cycle defrost performance of an air-to-water heat pump. Int. J. Refrigeration 27 (2004) 869-875
    • (2004) Int. J. Refrigeration , vol.27 , pp. 869-875
    • Huang, D.1    Yuan, X.2    Zhang, X.3
  • 7
    • 0029698127 scopus 로고    scopus 로고
    • Impact of the suction line accumulator on the frost/defrost performance of an air-source heat pump with a scroll compressor
    • Nutter D.W., O'Neal D.L., and Payne W.V. Impact of the suction line accumulator on the frost/defrost performance of an air-source heat pump with a scroll compressor. ASHRAE Trans. 102 (1996) 689-698
    • (1996) ASHRAE Trans. , vol.102 , pp. 689-698
    • Nutter, D.W.1    O'Neal, D.L.2    Payne, W.V.3
  • 8
    • 0025840669 scopus 로고
    • Effect of short-tube orifice size on the performance of an air source heat pump during the reverse-cycle defrost
    • O'Neal D.L., Peterson K., and Anand N.K. Effect of short-tube orifice size on the performance of an air source heat pump during the reverse-cycle defrost. Int. J. Refrigeration 14 (1991) 52-57
    • (1991) Int. J. Refrigeration , vol.14 , pp. 52-57
    • O'Neal, D.L.1    Peterson, K.2    Anand, N.K.3
  • 9
    • 0027874629 scopus 로고    scopus 로고
    • Payne, W.V., O'Neal, D.L., 1993. The effects of outdoor fan airflow on the frost/defrost performance of an air source heat pump. In: Heat Pump and Refrigeration Systems Design, Analysis and Applications, AES-vol. 29. ASME Winter Annual Meeting, New Orleans, Louisiana, November, 1993.
    • Payne, W.V., O'Neal, D.L., 1993. The effects of outdoor fan airflow on the frost/defrost performance of an air source heat pump. In: Heat Pump and Refrigeration Systems Design, Analysis and Applications, AES-vol. 29. ASME Winter Annual Meeting, New Orleans, Louisiana, November, 1993.
  • 10
    • 0029250487 scopus 로고
    • Defrost cycle performance for an air-source heat pump with a scroll and a reciprocating compressor
    • Payne V., and O'Neal D.L. Defrost cycle performance for an air-source heat pump with a scroll and a reciprocating compressor. Int. J. Refrigeration 18 (1995) 107-112
    • (1995) Int. J. Refrigeration , vol.18 , pp. 107-112
    • Payne, V.1    O'Neal, D.L.2
  • 11
    • 0021464104 scopus 로고
    • Selecting the size of pipes carrying hot gas to defrost evaporators
    • Stoecker W.F. Selecting the size of pipes carrying hot gas to defrost evaporators. Int. J. Refrigeration 7 4 (July 1984) 225-228
    • (1984) Int. J. Refrigeration , vol.7 , Issue.4 , pp. 225-228
    • Stoecker, W.F.1
  • 12
    • 0000722159 scopus 로고
    • Heat pump performance under frosting conditions: part II - simulation of heat pump cycle characteristics under frosting conditions
    • Yasuda Y., Senshu T., Kuroda S., Atsumi T., and Oguni K. Heat pump performance under frosting conditions: part II - simulation of heat pump cycle characteristics under frosting conditions. ASHRAE Trans. 96 1 (1990) 330-336
    • (1990) ASHRAE Trans. , vol.96 , Issue.1 , pp. 330-336
    • Yasuda, Y.1    Senshu, T.2    Kuroda, S.3    Atsumi, T.4    Oguni, K.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.