메뉴 건너뛰기




Volumn 76, Issue 3, 2010, Pages 614-618

What is the role of percutaneous needle core biopsy in diagnosis of renal masses?

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; AGED; ARTICLE; CANCER DIAGNOSIS; CLEAR CELL CARCINOMA; CLINICAL ARTICLE; COMPUTER ASSISTED TOMOGRAPHY; CONTROLLED STUDY; DIAGNOSTIC ACCURACY; ECHOGRAPHY; FEMALE; FOLLOW UP; HISTOPATHOLOGY; HUMAN; HUMAN TISSUE; KIDNEY BIOPSY; KIDNEY CARCINOMA; KIDNEY TUMOR; MALE; PREDICTIVE VALIDITY; PRIORITY JOURNAL; SENSITIVITY AND SPECIFICITY; TUMOR VOLUME; ENDOSCOPIC ECHOGRAPHY; MIDDLE AGED; NEEDLE BIOPSY; PATHOLOGY; PREDICTIVE VALUE; PROCEDURES; PROSPECTIVE STUDY; REPRODUCIBILITY; YOUNG ADULT;

EID: 78049445737     PISSN: 00904295     EISSN: 15279995     Source Type: Journal    
DOI: 10.1016/j.urology.2009.09.089     Document Type: Article
Times cited : (23)

References (30)
  • 1
    • 0031946395 scopus 로고    scopus 로고
    • Evaluation and management of solid and cystic renal masses
    • J.S. Wolf Evaluation and management of solid and cystic renal masses J Urol. 159 1998 1120 1133
    • (1998) J Urol. , vol.159 , pp. 1120-1133
    • Wolf, J.S.1
  • 2
    • 0034957267 scopus 로고    scopus 로고
    • Sonographically guided renal mass biopsy: Indications and efficacy
    • P.T. Johnson, L.N. Nazarian, and R.I. Feld Sonographically guided renal mass biopsy: indications and efficacy J Ultrasound Med. 20 2001 749 753
    • (2001) J Ultrasound Med. , vol.20 , pp. 749-753
    • Johnson, P.T.1    Nazarian, L.N.2    Feld, R.I.3
  • 3
    • 0028657011 scopus 로고
    • Clinicopathological characteristics of small renal carcinomas
    • M. Takashi, Y. Takagi, and T. Sakata Clinicopathological characteristics of small renal carcinomas Int Urol Nephrol. 26 1994 621 629
    • (1994) Int Urol Nephrol. , vol.26 , pp. 621-629
    • Takashi, M.1    Takagi, Y.2    Sakata, T.3
  • 4
    • 0030757179 scopus 로고    scopus 로고
    • Prospective evaluation of fine needle aspiration of small, solid renal masses: Accuracy and morbidity
    • DOI 10.1016/S0090-4295(97)00111-8, PII S0090429597001118
    • S.C. Campbell, A.C. Novick, and B. Herts Prospective evaluation of fine needle aspiration of small, solid renal masses: accuracy and morbidity Urology 50 1997 25 29 (Pubitemid 27300360)
    • (1997) Urology , vol.50 , Issue.1 , pp. 25-29
    • Campbell, S.C.1    Novick, A.C.2    Herts, B.3    Fischler, D.F.4    Meyer, J.5    Levin, H.S.6    Chen, R.N.7
  • 5
    • 0033980427 scopus 로고    scopus 로고
    • Evaluation of fine-needle aspiration cytology for renal masses
    • R.D. Brierly, P.J. Thomas, and N.W. Harrison Evaluation of fine-needle aspiration cytology for renal masses BJU Int. 85 2000 14 18
    • (2000) BJU Int. , vol.85 , pp. 14-18
    • Brierly, R.D.1    Thomas, P.J.2    Harrison, N.W.3
  • 6
    • 0035742831 scopus 로고    scopus 로고
    • Role of percutaneous image-guided biopsy in the evaluation of renal masses
    • I. Hara, H. Miyake, and S. Hara Role of percutaneous image-guided biopsy in the evaluation of renal masses Urol Int. 67 2001 199 202
    • (2001) Urol Int. , vol.67 , pp. 199-202
    • Hara, I.1    Miyake, H.2    Hara, S.3
  • 7
    • 0036062144 scopus 로고    scopus 로고
    • Evaluation of sonographically guided percutaneous core biopsy of renal masses
    • E.M. Caoili, R.O. Bude, and E.J. Higgins Evaluation of sonographically guided percutaneous core biopsy of renal masses AJR Am J Roentgenol. 179 2002 373 378
    • (2002) AJR Am J Roentgenol. , vol.179 , pp. 373-378
    • Caoili, E.M.1    Bude, R.O.2    Higgins, E.J.3
  • 8
    • 4644251853 scopus 로고    scopus 로고
    • Accuracy and clinical role of fine needle percutaneous biopsy with computerized tomography guidance of small (less than 4.0 cm) renal masses
    • Y. Neuzillet, E. Lechevallier, and M. Andre Accuracy and clinical role of fine needle percutaneous biopsy with computerized tomography guidance of small (less than 4.0 cm) renal masses J Urol. 171 2004 1802 1805
    • (2004) J Urol. , vol.171 , pp. 1802-1805
    • Neuzillet, Y.1    Lechevallier, E.2    Andre, M.3
  • 9
    • 0020376310 scopus 로고
    • Prognostic significance of morphologic parameters in renal cell carcinoma
    • S.A. Fuhrman, L.C. Lasky, and C. Limas Prognostic significance of morphologic parameters in renal cell carcinoma Am J Surg Pathol. 6 1982 655 663
    • (1982) Am J Surg Pathol. , vol.6 , pp. 655-663
    • Fuhrman, S.A.1    Lasky, L.C.2    Limas, C.3
  • 10
    • 0023706060 scopus 로고    scopus 로고
    • Improvement in survival of patients with renal cell carcinoma: The role of the serendipitously detected tumour
    • I.M. Thompson, and M. Peek Improvement in survival of patients with renal cell carcinoma: the role of the serendipitously detected tumour J Urol. 140 1998 487 490
    • (1998) J Urol. , vol.140 , pp. 487-490
    • Thompson, I.M.1    Peek, M.2
  • 11
    • 0032844163 scopus 로고    scopus 로고
    • Imaging guided biopsy of renal masses: Indications, accuracy and impact on clinical management
    • B.J. Wood, M.A. Khan, and F. McGovern Imaging guided biopsy of renal masses: indications, accuracy and impact on clinical management J Urol. 161 1999 1470 1474
    • (1999) J Urol. , vol.161 , pp. 1470-1474
    • Wood, B.J.1    Khan, M.A.2    McGovern, F.3
  • 12
    • 0033963021 scopus 로고    scopus 로고
    • Accuracy of diagnosis by guided biopsy of renal mass lesions classified indeterminate by imaging studies
    • F. Richter, N.G. Kasabian, and R.J. Irwin Jr Accuracy of diagnosis by guided biopsy of renal mass lesions classified indeterminate by imaging studies Urology 3 2000 348 352
    • (2000) Urology , vol.3 , pp. 348-352
    • Richter, F.1    Kasabian, N.G.2    Irwin Jr., R.J.3
  • 13
    • 0033790459 scopus 로고    scopus 로고
    • Radiofrequency ablation of the kidney: Acute and chronic histology in porcine model
    • T.H. Hsu, M.E. Fidler, and I.S. Gill Radiofrequency ablation of the kidney: acute and chronic histology in porcine model Urology 56 2000 872 875
    • (2000) Urology , vol.56 , pp. 872-875
    • Hsu, T.H.1    Fidler, M.E.2    Gill, I.S.3
  • 14
    • 0141496432 scopus 로고    scopus 로고
    • Interventional magnetic resonance image-guided percutaneous cryoablation or renal tumors
    • P.E. Sewell, J.C. Howard, and W.B. Shingleton Interventional magnetic resonance image-guided percutaneous cryoablation or renal tumors South Med J. 96 2003 708 710
    • (2003) South Med J. , vol.96 , pp. 708-710
    • Sewell, P.E.1    Howard, J.C.2    Shingleton, W.B.3
  • 15
    • 39149126300 scopus 로고    scopus 로고
    • Accuracy of imaging guided fine needle percutaneous biopsy of renal mases
    • D. Garcia, A. Prera, and M.A. Cabezuelo Accuracy of imaging guided fine needle percutaneous biopsy of renal mases Eur Urol Suppl. 6 2007 132
    • (2007) Eur Urol Suppl. , vol.6 , pp. 132
    • Garcia, D.1    Prera, A.2    Cabezuelo, M.A.3
  • 16
    • 0029990973 scopus 로고    scopus 로고
    • The case against fine-needle aspiration cytology for small solid kidney tumors
    • H. Goethuys, H. Van Poppel, and R. Oyen The case against fine-needle aspiration cytology for small solid kidney tumors Eur Urol. 29 1996 284 287
    • (1996) Eur Urol. , vol.29 , pp. 284-287
    • Goethuys, H.1    Van Poppel, H.2    Oyen, R.3
  • 17
    • 0022376496 scopus 로고
    • Renal cell carcinoma as an incidental finding
    • J.W. Konnak, and H.B. Grossman Renal cell carcinoma as an incidental finding J Urol. 134 1985 1094 1096
    • (1985) J Urol. , vol.134 , pp. 1094-1096
    • Konnak, J.W.1    Grossman, H.B.2
  • 18
    • 0028314250 scopus 로고
    • Cytologic study of renal angiomyolipoma by fine needle aspiration biopsy: Report of four cases
    • N. Tallada, S. Martinez, and A. Raventos Cytologic study of renal angiomyolipoma by fine needle aspiration biopsy: report of four cases Diagn Cytopathol. 10 1994 37 40
    • (1994) Diagn Cytopathol. , vol.10 , pp. 37-40
    • Tallada, N.1    Martinez, S.2    Raventos, A.3
  • 19
    • 0021914438 scopus 로고
    • Ultrasonically guided fine needle aspiration biopsy of renal masses
    • N. Juul, S. Torp-Peterson, and F. Gronvall Ultrasonically guided fine needle aspiration biopsy of renal masses J Urol. 133 1985 579 581
    • (1985) J Urol. , vol.133 , pp. 579-581
    • Juul, N.1    Torp-Peterson, S.2    Gronvall, F.3
  • 20
    • 0026083459 scopus 로고
    • Role of fine-needle aspiration biopsy in the assessment of renal masses
    • E.G. Cristallini, C. Paganelli, and G.B. Bolis Role of fine-needle aspiration biopsy in the assessment of renal masses Diagn Cytopathol. 7 1991 32 35
    • (1991) Diagn Cytopathol. , vol.7 , pp. 32-35
    • Cristallini, E.G.1    Paganelli, C.2    Bolis, G.B.3
  • 21
    • 24144481548 scopus 로고    scopus 로고
    • An update of the Bosniak renal cyst classification system
    • G.M. Israel, and M.A. Bosniak An update of the Bosniak renal cyst classification system Urology 66 2005 484 488
    • (2005) Urology , vol.66 , pp. 484-488
    • Israel, G.M.1    Bosniak, M.A.2
  • 22
    • 0027146282 scopus 로고
    • Diagnosis of renal cell carcinoma: Value of fine-needle aspiration cytology in patients with metastasis or contraindications to nephrectomy
    • J.R. Nicefero, and B.R. Coughlin Diagnosis of renal cell carcinoma: value of fine-needle aspiration cytology in patients with metastasis or contraindications to nephrectomy AJR Am J Roentgenol. 161 1993 1303 1305
    • (1993) AJR Am J Roentgenol. , vol.161 , pp. 1303-1305
    • Nicefero, J.R.1    Coughlin, B.R.2
  • 23
    • 0025930614 scopus 로고
    • US-guided fine needle biopsy of solid renal massescomparison of histology and cytology
    • S. Torp-Pedersen, N. Juul, and T. Larsen US-guided fine needle biopsy of solid renal massescomparison of histology and cytology Scand J Urol Nephrol Suppl. 137 1991 41 43
    • (1991) Scand J Urol Nephrol Suppl. , vol.137 , pp. 41-43
    • Torp-Pedersen, S.1    Juul, N.2    Larsen, T.3
  • 24
    • 33846547997 scopus 로고    scopus 로고
    • Renal mass core biopsy: Accuracy and impact on clinical management
    • K.E. Maturen, H.V. Nghiem, and E.M. Caoili Renal mass core biopsy: accuracy and impact on clinical management AJR Am J Roentgenol. 188 2007 563 570
    • (2007) AJR Am J Roentgenol. , vol.188 , pp. 563-570
    • Maturen, K.E.1    Nghiem, H.V.2    Caoili, E.M.3
  • 25
    • 0032822242 scopus 로고    scopus 로고
    • Prospective analysis of intraoperative frozen needle biopsy of solid renal masses in adults
    • C.B. Dechet, T. Sebo, and G. Farrow Prospective analysis of intraoperative frozen needle biopsy of solid renal masses in adults J Urol. 162 1999 1282 1284
    • (1999) J Urol. , vol.162 , pp. 1282-1284
    • Dechet, C.B.1    Sebo, T.2    Farrow, G.3
  • 26
    • 20444458672 scopus 로고    scopus 로고
    • The accuracy of 250 fine needle biopsies of renal tumors
    • H. Wunderlich, W. Hindermann, and A.M. Al Mustafa The accuracy of 250 fine needle biopsies of renal tumors J Urol. 174 2005 44 46
    • (2005) J Urol. , vol.174 , pp. 44-46
    • Wunderlich, H.1    Hindermann, W.2    Al Mustafa, A.M.3
  • 28
    • 55649083090 scopus 로고    scopus 로고
    • Contemporary results of percutaneous biopsy of 100 small renal masses: A single center experience
    • A. Volpe, K. Mattar, and A. Finelli Contemporary results of percutaneous biopsy of 100 small renal masses: a single center experience J Urol. 180 2008 2333 2337
    • (2008) J Urol. , vol.180 , pp. 2333-2337
    • Volpe, A.1    Mattar, K.2    Finelli, A.3
  • 29
    • 33750338171 scopus 로고    scopus 로고
    • Diagnosis of renal tumors on needle biopsy specimens by histological and molecular analysis
    • D.A. Barocas, S.M. Rohan, and J. Kao Diagnosis of renal tumors on needle biopsy specimens by histological and molecular analysis J Urol. 176 2006 1957 1962
    • (2006) J Urol. , vol.176 , pp. 1957-1962
    • Barocas, D.A.1    Rohan, S.M.2    Kao, J.3
  • 30


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.