메뉴 건너뛰기




Volumn 31, Issue 2-3, 2011, Pages 391-398

Efficiency improvement of a ground coupled heat pump system from energy management

Author keywords

Energy efficiency; Ground coupled heat pump; Numerical simulation

Indexed keywords

AIR FLOW; AIRCONDITIONING SYSTEMS; EFFICIENCY IMPROVEMENT; ELECTRICAL CONSUMPTION; ENERGY SAVING; GROUND COUPLED HEAT PUMP; GROUND-COUPLED HEAT PUMP SYSTEMS; HEAT PUMPS; HEATING DEMAND; HYDRAULIC SYSTEM; INSTALLED CAPACITY; MANAGEMENT STRATEGIES; NUMERICAL SIMULATION; SET-POINT TEMPERATURES; THERMAL DEMANDS; WATER MASS FLOW;

EID: 78049443297     PISSN: 13594311     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.applthermaleng.2010.09.016     Document Type: Article
Times cited : (23)

References (25)
  • 1
    • 0035254450 scopus 로고    scopus 로고
    • Estimates of the energy impact of the ventilation and associated financial experience
    • M. Orme Estimates of the energy impact of the ventilation and associated financial experience Energy and Buildings 33 2001 199 255
    • (2001) Energy and Buildings , vol.33 , pp. 199-255
    • Orme, M.1
  • 2
    • 78049425896 scopus 로고    scopus 로고
    • International Energy Agency (IEA)
    • International Energy Agency (IEA), in: http://www.iea.org.
  • 3
    • 77955677998 scopus 로고    scopus 로고
    • INSEE (Institut de Statistique et des Etudes Economiques) Paris, France
    • P. Champsour Recensement de la Population 1999 - 2000 INSEE (Institut de Statistique et des Etudes Economiques) Paris, France pp. 4 ISSN 0997-3192
    • (2000) Recensement de la Population 1999
    • Champsour, P.1
  • 5
    • 0034745968 scopus 로고    scopus 로고
    • World-wide direct uses of geothermal energy 2000
    • J.W. Lund, and D.H. Freeston World-wide direct uses of geothermal energy 2000 Geothermics 30 2001 29 68
    • (2001) Geothermics , vol.30 , pp. 29-68
    • Lund, J.W.1    Freeston, D.H.2
  • 7
    • 0142182738 scopus 로고    scopus 로고
    • Current status of ground source heat pumps and underground thermal storage in Europe
    • B. Sanner, C. Karytsas, D. Mendrinos, and L. Rybach Current status of ground source heat pumps and underground thermal storage in Europe Geothermics 32 2003 579 588
    • (2003) Geothermics , vol.32 , pp. 579-588
    • Sanner, B.1    Karytsas, C.2    Mendrinos, D.3    Rybach, L.4
  • 8
    • 62949216359 scopus 로고    scopus 로고
    • Experimental comparative analysis of a ground coupled heat pump system versus a conventional air-to-air heat pump in typical conditions of the European Mediterranean coast
    • Climamed 2006, Lyon, France
    • J.F. Urchueguía, M. Zacarés, Á. Montero, J. Martos, Experimental comparative analysis of a ground coupled heat pump system versus a conventional air-to-air heat pump in typical conditions of the European Mediterranean coast, in: Proceedings of the Energy, Climate and Indoor Comfort in Mediterranean Countries, Climamed 2006, Lyon, France, 2006.
    • (2006) Proceedings of the Energy, Climate and Indoor Comfort in Mediterranean Countries
    • Urchueguía, J.F.1
  • 9
    • 36749048841 scopus 로고    scopus 로고
    • Ground-source heat pump systems and applications
    • A.M. Omer Ground-source heat pump systems and applications Renewable and Sustainable Energy Reviews 12 2008 344 371
    • (2008) Renewable and Sustainable Energy Reviews , vol.12 , pp. 344-371
    • Omer, A.M.1
  • 10
    • 0001546031 scopus 로고
    • An optimized ground coupled heat pump systems design for northern climate applications
    • M.A. Catan, and V.D. Baxter An optimized ground coupled heat pump systems design for northern climate applications ASHRAE Transactions 91 2B 1985 1185 1203
    • (1985) ASHRAE Transactions , vol.91 , Issue.2 B , pp. 1185-1203
    • Catan, M.A.1    Baxter, V.D.2
  • 11
    • 0001462353 scopus 로고
    • A design and economic sensitivity study of single pipe horizontal ground coupled heat pump systems
    • P.E. Martin A design and economic sensitivity study of single pipe horizontal ground coupled heat pump systems ASHRAE Transactions 96 1 1990 634 642
    • (1990) ASHRAE Transactions , vol.96 , Issue.1 , pp. 634-642
    • Martin, P.E.1
  • 13
    • 48849105904 scopus 로고    scopus 로고
    • Comparison between the energy performance of a group coupled water to water heat pump system and an air to water heat pump system for heating and cooling in typical conditions of the European Mediterranean Coast
    • J.F. Urchueguía, M. Zacarés, J.M. Corberán, Á Montero, J. Martos, and H. Witte Comparison between the energy performance of a group coupled water to water heat pump system and an air to water heat pump system for heating and cooling in typical conditions of the European Mediterranean Coast Energy Conversion and Management 49 2008 2917 2923
    • (2008) Energy Conversion and Management , vol.49 , pp. 2917-2923
    • Urchueguía, J.F.1    Zacarés, M.2    Corberán, J.M.3    Montero, Á.4    Martos, J.5    Witte, H.6
  • 14
    • 78049417380 scopus 로고    scopus 로고
    • Energy Star Program from US Environment Protection Agency
    • Energy Star Program from US Environment Protection Agency, in: http://www.energystar.gov.
  • 15
    • 18944387882 scopus 로고    scopus 로고
    • Ground-source heat pump system research - Past, present and future
    • J.D. Spitler Ground-source heat pump system research - past, present and future HVAC & Research 11 2 2005
    • (2005) HVAC & Research , vol.11 , Issue.2
    • Spitler, J.D.1
  • 16
    • 0031247529 scopus 로고    scopus 로고
    • An analysis of the performance of different intermittent heating controllers and an evaluation of comfort and energy consumption
    • G. Fraisse, J. Virgone, and J. Brau An analysis of the performance of different intermittent heating controllers and an evaluation of comfort and energy consumption HVAC & R Research 3 4 1997
    • (1997) HVAC & R Research , vol.3 , Issue.4
    • Fraisse, G.1    Virgone, J.2    Brau, J.3
  • 17
    • 4944229278 scopus 로고    scopus 로고
    • An experimental study on an inferential control scheme for optimising the control of boiler in multi-zone heating system
    • Z. Liao, and A.L. Dexter An experimental study on an inferential control scheme for optimising the control of boiler in multi-zone heating system Energy and Buildings 37 2005 55 63
    • (2005) Energy and Buildings , vol.37 , pp. 55-63
    • Liao, Z.1    Dexter, A.L.2
  • 18
    • 29144439156 scopus 로고    scopus 로고
    • HVAC system optimization for energy management by evolutionary programming
    • K.F. Fong, V.I. Hanby, and T.T. Chow HVAC system optimization for energy management by evolutionary programming Energy and Buildings 38 2005 220 231
    • (2005) Energy and Buildings , vol.38 , pp. 220-231
    • Fong, K.F.1    Hanby, V.I.2    Chow, T.T.3
  • 19
    • 0032685821 scopus 로고    scopus 로고
    • A numerical comparison of different methods for optimizing heating-restart time in intermittently occupied buildings
    • G. Fraisse, J. Virgone, and R. Yezoy A numerical comparison of different methods for optimizing heating-restart time in intermittently occupied buildings Applied Energy 62 1999 125 140
    • (1999) Applied Energy , vol.62 , pp. 125-140
    • Fraisse, G.1    Virgone, J.2    Yezoy, R.3
  • 20
    • 77649269867 scopus 로고    scopus 로고
    • Optimization of hybrid -ground coupled and air source - Heat pump systems in combination with thermal storage
    • N. Pardo, Á Montero, J. Martos, and J.F. Urchueguía Optimization of hybrid -ground coupled and air source - heat pump systems in combination with thermal storage Applied Thermal Engineering 30 2010 1073 1077
    • (2010) Applied Thermal Engineering , vol.30 , pp. 1073-1077
    • Pardo, N.1    Montero, Á.2    Martos, J.3    Urchueguía, J.F.4
  • 22
    • 78049414857 scopus 로고    scopus 로고
    • TRNSYS 16.1: Transient System Simulation Program. University of Wisconsin, Madison (USA): Solar Energy Laboratory, 2006
    • TRNSYS 16.1: Transient System Simulation Program. University of Wisconsin, Madison (USA): Solar Energy Laboratory, 2006.
  • 23
    • 0003944039 scopus 로고
    • Department of Mathematical Physics, University of Lund Sweden
    • G. Hellström Duct Ground Heat Storage Model 1989 Department of Mathematical Physics, University of Lund Sweden
    • (1989) Duct Ground Heat Storage Model
    • Hellström, G.1
  • 24
    • 77955669040 scopus 로고    scopus 로고
    • Ground-source heat pump project analysis
    • CANMET Energy Technology Centre - Varennes (CTEC), Minister of Natural Resource Canada
    • Ground-source heat pump project analysis Clean Energy Project Analysis 2001-2005 CANMET Energy Technology Centre - Varennes (CTEC), Minister of Natural Resource Canada
    • (2001) Clean Energy Project Analysis
  • 25
    • 77954276894 scopus 로고    scopus 로고
    • Development and validation of a fan performance model for typical packaged HVAC systems
    • K. Zheng, and H. Li Development and validation of a fan performance model for typical packaged HVAC systems ASHRAE Transactions 2010 Report 3505
    • (2010) ASHRAE Transactions
    • Zheng, K.1    Li, H.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.