메뉴 건너뛰기




Volumn 62, Issue 3, 1999, Pages 125-140

A numerical comparison of different methods for optimizing heating-restart time in intermittently occupied buildings

Author keywords

[No Author keywords available]

Indexed keywords

BUILDINGS; COMPUTER SIMULATION; COMPUTER SOFTWARE; ENERGY UTILIZATION; FUZZY SETS; HEATING EQUIPMENT;

EID: 0032685821     PISSN: 03062619     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0306-2619(99)00005-7     Document Type: Article
Times cited : (22)

References (16)
  • 2
    • 0003670713 scopus 로고
    • Algorithms for predicting recovery time from night setback
    • Seem J.E., Armstrong P.R., Hancock C.E. Algorithms for predicting recovery time from night setback. ASHRAE transactions. 95:(2):1989;439-446.
    • (1989) ASHRAE Transactions , vol.95 , Issue.2 , pp. 439-446
    • Seem, J.E.1    Armstrong, P.R.2    Hancock, C.E.3
  • 3
    • 0041126497 scopus 로고
    • La commande optimale, un outil d'aide à la définition de stratégies de gestion
    • Sophia-Antipolis, Congress RCT'93, 24-25 November
    • Visier JC, Paillassa V, Mark A, Foucard MH. La commande optimale, un outil d'aide à la définition de stratégies de gestion. Journées Régulation Commande Télégestion, Sophia-Antipolis, Congress RCT'93, 24-25 November 1993.
    • (1993) Journées Régulation Commande Télégestion
    • Visier, J.C.1    Paillassa, V.2    Mark, A.3    Foucard, M.H.4
  • 4
    • 33749911068 scopus 로고
    • Modélisation d'un bâtiment par un réseau neuronal
    • Sophia-Antipolis, Congress RCT'93, 24-25 November
    • Glorennec PY. Modélisation d'un bâtiment par un réseau neuronal. Journées Régulation Commande Télégestion, Sophia-Antipolis, Congress RCT'93, 24-25 November 1993.
    • (1993) Journées Régulation Commande Télégestion
    • Glorennec, P.Y.1
  • 8
    • 0031247529 scopus 로고    scopus 로고
    • An analysis of the performance of different intermittent heating controllers and an evaluation of comfort and energy consumption
    • Fraisse G., Virgone J., Brau J. An analysis of the performance of different intermittent heating controllers and an evaluation of comfort and energy consumption. HVAC & R Research. 3:(4):1997;369-386.
    • (1997) HVAC & R Research , vol.3 , Issue.4 , pp. 369-386
    • Fraisse, G.1    Virgone, J.2    Brau, J.3
  • 14
    • 0031249066 scopus 로고    scopus 로고
    • Thermal control of a discontinuously-occupied building using a classical and a fuzzy logic approach
    • Fraisse G., Virgone J., Roux J.J. Thermal control of a discontinuously-occupied building using a classical and a fuzzy logic approach. Energy and Buildings. 26:(3):1997;303-316.
    • (1997) Energy and Buildings , vol.26 , Issue.3 , pp. 303-316
    • Fraisse, G.1    Virgone, J.2    Roux, J.J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.