-
1
-
-
33746478730
-
The first human renal transplants
-
Barry J M., Murray J E. The first human renal transplants. J Urol 2006 176 888-890
-
(2006)
J Urol
, vol.176
, pp. 888-890
-
-
Barry, J.M.1
Murray, J.E.2
-
2
-
-
13844267082
-
The first successful organ transplants in man
-
Murray J E. The first successful organ transplants in man. J Am Coll Surg 2005 200 5-9
-
(2005)
J Am Coll Surg
, vol.200
, pp. 5-9
-
-
Murray, J.E.1
-
3
-
-
78049402045
-
-
Eurotransplant International Foundation. Leiden, Netherlands
-
Eurotransplant International Foundation. Leiden, Netherlands. http://www.eurotransplant.nl/files/statistics/year-2009.pdf
-
-
-
-
4
-
-
12344254781
-
European Association of Urology. EAU guidelines on renal transplantation
-
Kälble T, Lucan M, Nicita G et al. European Association of Urology. EAU guidelines on renal transplantation. Eur Urol 2005 47 156-66, Review
-
(2005)
Eur Urol
, vol.47
, pp. 156-66
-
-
Kälble, T.1
Lucan, M.2
Nicita, G.3
-
5
-
-
15944384571
-
A Report of the Amsterdam Forum on the Care of the Live Kidney Donor: Data and Medical Guidelines
-
Council of the Transplantation Society
-
Delmonico F, Council of the Transplantation Society. A Report of the Amsterdam Forum On the Care of the Live Kidney Donor: Data and Medical Guidelines. Transplantation 2005 79 (6 Suppl) S53-S66, Review
-
(2005)
Transplantation
, vol.79
, Issue.6 SUPPL.
-
-
Delmonico, F.1
-
6
-
-
0033854193
-
Assessment of 100 live potential renal donors for laparoscopic nephrectomy the new criterion standard?
-
Sasaki T M., Finelli F, Bugarin E et al. Assessment of 100 live potential renal donors for laparoscopic nephrectomy the new criterion standard? Arch Surg 2000 135 943-947
-
(2000)
Arch Surg
, vol.135
, pp. 943-947
-
-
Sasaki, T.M.1
Finelli, F.2
Bugarin, E.3
-
7
-
-
0034838895
-
Helical CT angiography in evaluation of live kidney donors
-
Patil U D., Ragavan A, Nadaraj et al. Helical CT angiography in evaluation of live kidney donors. Nephrol Dial Transplant 2001 16 1900-1904
-
(2001)
Nephrol Dial Transplant
, vol.16
, pp. 1900-1904
-
-
Patil, U.D.1
Ragavan, A.2
Nadaraj3
-
8
-
-
0022459783
-
Anatomic abnormalities of cadaver kidneys procured for purposes of transplantation
-
Pollak R, Prusak B F., Mozes M F. Anatomic abnormalities of cadaver kidneys procured for purposes of transplantation. Am Aurg 1986 52 233-235
-
(1986)
Am Aurg
, vol.52
, pp. 233-235
-
-
Pollak, R.1
Prusak, B.F.2
Mozes, M.F.3
-
9
-
-
28444464808
-
Preoperative evaluation of living kidney donors using multirow detector computed tomography: Comparison with digital subtraction angiography and intraoperative findings
-
Hänninen E L., Denecke T, Stelter L et al. Preoperative evaluation of living kidney donors using multirow detector computed tomography: comparison with digital subtraction angiography and intraoperative findings. Transpl Int 2005 18 1134-1141
-
(2005)
Transpl Int
, vol.18
, pp. 1134-1141
-
-
Hänninen, E.L.1
Denecke, T.2
Stelter, L.3
-
10
-
-
0038340864
-
Prospective comparison of 3-dimensional volume rendered computerized tomography and conventional renal arteriography for surgical planning in patients undergoing laparoscopic donor nephrectomy
-
El Fettouh H A., Herts B R., Nimeh T et al. Prospective comparison of 3-dimensional volume rendered computerized tomography and conventional renal arteriography for surgical planning in patients undergoing laparoscopic donor nephrectomy. J Urol 2003 170 57-60
-
(2003)
J Urol
, vol.170
, pp. 57-60
-
-
El Fettouh, H.A.1
Herts, B.R.2
Nimeh, T.3
-
11
-
-
38149104615
-
Donor-Evaluation vor Lebendnierenspende: Vergleich von CE-MRA und DSA an 78 Patienten
-
Lemke U, Taupitz M, Klüner C et al. Donor-Evaluation vor Lebendnierenspende: Vergleich von CE-MRA und DSA an 78 Patienten. Fortschr Röntgenstr 2008 180 48-54
-
(2008)
Fortschr Röntgenstr
, vol.180
, pp. 48-54
-
-
Lemke, U.1
Taupitz, M.2
Klüner, C.3
-
12
-
-
47649130118
-
Analysis of 64-row multidetector CT images for preoperative angiographic evaluation of potential living kidney donors
-
Blondin D, Andersen K, Kroepil P et al. Analysis of 64-row multidetector CT images for preoperative angiographic evaluation of potential living kidney donors. Der Radiologe 2008 48 673-680
-
(2008)
Der Radiologe
, vol.48
, pp. 673-680
-
-
Blondin, D.1
Andersen, K.2
Kroepil, P.3
-
13
-
-
7244247159
-
Accuracy of computed tomographic angiography and magnetic resonance angiography for diagnosing renal artery stenosis
-
the Renal Artery Diagnostic Imaging Study in Hypertension (RADISH) Study Group
-
Vasbinder G B., Nelemans P J., Kessels A G., the Renal Artery Diagnostic Imaging Study in Hypertension (RADISH) Study Group. Accuracy of computed tomographic angiography and magnetic resonance angiography for diagnosing renal artery stenosis. Ann Intern Med 2004 141 674-682
-
(2004)
Ann Intern Med
, vol.141
, pp. 674-682
-
-
Vasbinder, G.B.1
Nelemans, P.J.2
Kessels, A.G.3
-
14
-
-
0034930477
-
Noninvasive imaging of living related kidney donors: Evaluation with CT angiography and gadolinium-enhanced MR angiography
-
Rankin S C., Jan W, Koffman C G. Noninvasive imaging of living related kidney donors: evaluation with CT angiography and gadolinium-enhanced MR angiography. Am J Roentgenol 2001 177 349-355
-
(2001)
Am J Roentgenol
, vol.177
, pp. 349-355
-
-
Rankin, S.C.1
Jan, W.2
Koffman, C.G.3
-
15
-
-
0031862273
-
Steady-state and dynamic MR angiography with MS-325: Initial experience in humans
-
Grist T M., Korosec F R., Peters D C. et al. Steady-state and dynamic MR angiography with MS-325: initial experience in humans. Radiology 1998 207 539-544
-
(1998)
Radiology
, vol.207
, pp. 539-544
-
-
Grist, T.M.1
Korosec, F.R.2
Peters, D.C.3
-
16
-
-
35348941935
-
MRI of the kidney state of the art
-
Nikken J J., Krestin G P. MRI of the kidney state of the art. Eur Radiol 2007 17 2780-2793
-
(2007)
Eur Radiol
, vol.17
, pp. 2780-2793
-
-
Nikken, J.J.1
Krestin, G.P.2
-
17
-
-
0031836465
-
MS-325: Albumin-targeted contrast agent for MR angiography
-
Lauffer R B., Parmelee D J., Dunham S U. et al. MS-325: albumin-targeted contrast agent for MR angiography. Radiology 1998 207 529-538
-
(1998)
Radiology
, vol.207
, pp. 529-538
-
-
Lauffer, R.B.1
Parmelee, D.J.2
Dunham, S.U.3
-
18
-
-
0031435887
-
Preclinical evaluation of the pharmacokinetics, biodistribution, and elimination of MS-325, a blood pool agent for magnetic resonance imaging
-
Parmelee D J., Wlovitvh R C., Ouellet H S. et al. Preclinical evaluation of the pharmacokinetics, biodistribution, and elimination of MS-325, a blood pool agent for magnetic resonance imaging. Invest Radiol 1997 32 741-747
-
(1997)
Invest Radiol
, vol.32
, pp. 741-747
-
-
Parmelee, D.J.1
Wlovitvh, R.C.2
Ouellet, H.S.3
-
19
-
-
36248932721
-
Noise Measurement and estimation in MR imaging experiments
-
Heverhagen J T. Noise Measurement and estimation in MR imaging experiments. Radiology 2007 245 638-639
-
(2007)
Radiology
, vol.245
, pp. 638-639
-
-
Heverhagen, J.T.1
-
20
-
-
33846470999
-
High-spatial-resolution multistation MR angiography with parallel imaging and blood pool contrast agent: Initial experience
-
Nikolaou K, Kramer H, Grosse C et al. High-spatial-resolution multistation MR angiography with parallel imaging and blood pool contrast agent: initial experience. Radiology 2006 241 861-872
-
(2006)
Radiology
, vol.241
, pp. 861-872
-
-
Nikolaou, K.1
Kramer, H.2
Grosse, C.3
-
21
-
-
66149146677
-
Gadofosveset-enhanced MR angiography of carotid arteries: Does steady-state imaging improve accuracy of first-pass imaging? Comparison with selective digital subtraction angiography
-
Anzidei M, Napoli A, Marincola B C. et al. Gadofosveset-enhanced MR angiography of carotid arteries: does steady-state imaging improve accuracy of first-pass imaging? Comparison with selective digital subtraction angiography. Radiology 2009 251 457-466
-
(2009)
Radiology
, vol.251
, pp. 457-466
-
-
Anzidei, M.1
Napoli, A.2
Marincola, B.C.3
-
22
-
-
56149116587
-
Peripheral MR angiography with blood pool contrast agent: Prospective intraindividual comparative study of high-spatial-resolution steady-state MR angiography versus standard-resolution first-pass MR angiography and DSA
-
Hadizadeh D R., Gieseke J, Lohmaier S H. et al. Peripheral MR angiography with blood pool contrast agent: prospective intraindividual comparative study of high-spatial-resolution steady-state MR angiography versus standard-resolution first-pass MR angiography and DSA. Radiology 2008 249 701-711
-
(2008)
Radiology
, vol.249
, pp. 701-711
-
-
Hadizadeh, D.R.1
Gieseke, J.2
Lohmaier, S.H.3
-
23
-
-
0036774628
-
Comparison of MS-325- and gadodiamide-enhanced MR venography of iliocaval veins
-
Sharafuddin M J., Stolpen A H., Dang Y M. et al. Comparison of MS-325- and gadodiamide-enhanced MR venography of iliocaval veins. J VascInterv Radiol 2002 13 1021-1027
-
(2002)
J VascInterv Radiol
, vol.13
, pp. 1021-1027
-
-
Sharafuddin, M.J.1
Stolpen, A.H.2
Dang, Y.M.3
-
24
-
-
34247590911
-
Molecular MRI of cerebral venous sinus thrombosis using a new finbrin-specific MR contrast-agent
-
Stracke C P., Katoh M, Wiethoff et al. Molecular MRI of cerebral venous sinus thrombosis using a new finbrin-specific MR contrast-agent. Stroke 2007 38 1476-1481
-
(2007)
Stroke
, vol.38
, pp. 1476-1481
-
-
Stracke, C.P.1
Katoh, M.2
Wiethoff3
-
25
-
-
33644998467
-
Magnetic resonance renal angiography and venography: An analysis of 111 consecutive scans before donor nephrectomy
-
Hodgson D J., Jan W, Rankin S et al. Magnetic resonance renal angiography and venography: an analysis of 111 consecutive scans before donor nephrectomy. BJU Int 2006 97 584-586
-
(2006)
BJU Int
, vol.97
, pp. 584-586
-
-
Hodgson, D.J.1
Jan, W.2
Rankin, S.3
-
26
-
-
0036828527
-
Comprehensive MR imaging in the preoperative evaluation of living donor candidates for laparoscopic nephrectomy: Initial experience
-
Israel G M., Lee V S., Edye M et al. Comprehensive MR imaging in the preoperative evaluation of living donor candidates for laparoscopic nephrectomy: initial experience. Radiology 2002 225 427-432
-
(2002)
Radiology
, vol.225
, pp. 427-432
-
-
Israel, G.M.1
Lee, V.S.2
Edye, M.3
-
27
-
-
0032905724
-
Sinlge-dose reath-hold gadolinium-enhanced three-dimensional MR angiography of the renal arteries
-
Lee V S., Rofsky N M., Krinsky G A. et al. Sinlge-dose reath-hold gadolinium-enhanced three-dimensional MR angiography of the renal arteries. Radiology 1999 211 69-78
-
(1999)
Radiology
, vol.211
, pp. 69-78
-
-
Lee, V.S.1
Rofsky, N.M.2
Krinsky, G.A.3
-
28
-
-
27444435487
-
Prospective study comparing three-dimensional computed tomography and magnetic resonance imaging for evaluating the renal vascular anatomy in potential living renal donors
-
Bhatti A A., Chugtai A, Haslam P et al. Prospective study comparing three-dimensional computed tomography and magnetic resonance imaging for evaluating the renal vascular anatomy in potential living renal donors. BJU Int 2005 96 1105-1108
-
(2005)
BJU Int
, vol.96
, pp. 1105-1108
-
-
Bhatti, A.A.1
Chugtai, A.2
Haslam, P.3
-
29
-
-
33646373940
-
High-resolution magnetic resonance angiography of the renal arteries using parallel imaging acquisition techniques at 3.0 T: Initial experience
-
DOI 10.1097/01.rli.0000195838.94440.20, PII 0000442420060200000010
-
Fenchel M, Nael K, Deshpande V S. et al. Renal magnetic resonance angiography at 3.0 Tesla using a 32-element phased-array coil systsem and parallel imaging in 2 directions. Invest Radiol 2006 41 125-132 (Pubitemid 44406209)
-
(2006)
Investigative Radiology
, vol.41
, Issue.2
, pp. 125-132
-
-
Kramer, U.1
Nael, K.2
Laub, G.3
Nyborg, G.K.4
Fenchel, M.5
Miller, S.6
Claussen, C.D.7
Finn, J.P.8
-
30
-
-
0028102830
-
Leistungsfähigkeit der CT-Angiographie beim Nachweis Nierenarterienstenosen
-
Galanski M, Prokop M, Chavan A et al. Leistungsfähigkeit der CT-Angiographie beim Nachweis Nierenarterienstenosen. Fortschr Röntgenstr 1994 161 519-525
-
(1994)
Fortschr Röntgenstr
, vol.161
, pp. 519-525
-
-
Galanski, M.1
Prokop, M.2
Chavan, A.3
-
31
-
-
0030805663
-
Evaluation of renal artery stenosis with dynamic gadolinium-enhanced MR angiography
-
Rieumont M J., Kaufman J A., Geller S C. et al. Evaluation of renal artery stenosis with dynamic gadolinium-enhanced MR angiography. Am J Roentgenol 1997 169 39-44
-
(1997)
Am J Roentgenol
, vol.169
, pp. 39-44
-
-
Rieumont, M.J.1
Kaufman, J.A.2
Geller, S.C.3
-
32
-
-
0029918113
-
Spiral computed tomographic angiography of the renal arteries: A prospective comparison with intravenous and intraarterial digital subtraction angiography
-
Farres M T., Lammer J, Schima W et al. Spiral computed tomographic angiography of the renal arteries: a prospective comparison with intravenous and intraarterial digital subtraction angiography. Cardiovasc Intervent Radiol 1996 19 101-106
-
(1996)
Cardiovasc Intervent Radiol
, vol.19
, pp. 101-106
-
-
Farres, M.T.1
Lammer, J.2
Schima, W.3
-
33
-
-
0344936717
-
Renal artery evaluation: Comparison of spiral CT angiography to intra-arterial DSA
-
Kim T S., Chung J W., Park J H. et al. Renal artery evaluation: comparison of spiral CT angiography to intra-arterial DSA. J Vasc Interv Radiol 1998 9 553-559
-
(1998)
J Vasc Interv Radiol
, vol.9
, pp. 553-559
-
-
Kim, T.S.1
Chung, J.W.2
Park, J.H.3
-
34
-
-
0036137599
-
Morphologic and functional magnetic resonance imaging of renal artery stenosis: A multireader tricenter study
-
Schoenberg S O., Knopp M V., Londy F et al. Morphologic and functional magnetic resonance imaging of renal artery stenosis: a multireader tricenter study. J Am Soc Nephrol 2002 13 158-169
-
(2002)
J Am Soc Nephrol
, vol.13
, pp. 158-169
-
-
Schoenberg, S.O.1
Knopp, M.V.2
Londy, F.3
-
35
-
-
0036890799
-
Motion of the distal renal artery during three-dimensional contrast-enhanced breath-hold MRA
-
Vasbinder G B., Maki J H., Nijenhuis R J. et al. Motion of the distal renal artery during three-dimensional contrast-enhanced breath-hold MRA. J Magn Reson Imaging 2002 16 685-696
-
(2002)
J Magn Reson Imaging
, vol.16
, pp. 685-696
-
-
Vasbinder, G.B.1
Maki, J.H.2
Nijenhuis, R.J.3
-
36
-
-
33645130692
-
Renal arteries: Comparison of steady-state free precession MR angiography and contrast-enhanced MR angiography
-
Herborn C U., Watkins D M., Runge V M. et al. Renal arteries: comparison of steady-state free precession MR angiography and contrast-enhanced MR angiography. Radiology 2006 239 263-268
-
(2006)
Radiology
, vol.239
, pp. 263-268
-
-
Herborn, C.U.1
Watkins, D.M.2
Runge, V.M.3
-
37
-
-
34548682585
-
Renal artery assessment with nonenhanced steady-state free precession versus contrast-enhanced MR angiography
-
Wyttenbach R, Braghetti A, Wyss M et al. Renal artery assessment with nonenhanced steady-state free precession versus contrast-enhanced MR angiography. Radiology 2007 245 186-195
-
(2007)
Radiology
, vol.245
, pp. 186-195
-
-
Wyttenbach, R.1
Braghetti, A.2
Wyss, M.3
-
38
-
-
70349287706
-
ECG-gated nonenhanced 3D steady-state free precession (SSFP) MR angiography (MRA) in assessment of transplant renal arteries: Comparison with digital substraction angiography (DSA)
-
Lanzman R S., Voiculescu A, Walther C et al. ECG-gated nonenhanced 3D steady-state free precession (SSFP) MR angiography (MRA) in assessment of transplant renal arteries: comparison with digital substraction angiography (DSA). Radiology 2009 252 914-921
-
(2009)
Radiology
, vol.252
, pp. 914-921
-
-
Lanzman, R.S.1
Voiculescu, A.2
Walther, C.3
-
39
-
-
4344580445
-
Free-breathing renal MR angiography with steady-state free-precession (SSFP) and slab-selective spin inversion: Initial results
-
Katoh M, Buecker A, Stuber M et al. Free-breathing renal MR angiography with steady-state free-precession (SSFP) and slab-selective spin inversion: Initial results. Kidney International 2004 66 1272-1278
-
(2004)
Kidney International
, vol.66
, pp. 1272-1278
-
-
Katoh, M.1
Buecker, A.2
Stuber, M.3
-
40
-
-
77749252444
-
Nonenhanced free-breathing ECG-gated steady-state free precession 3D MR angiography of the renal arteries: Comparison between 1.5T and 3T
-
Lanzman R S., Kröpil P, Schmitt P et al. Nonenhanced free-breathing ECG-gated steady-state free precession 3D MR angiography of the renal arteries: comparison between 1.5T and 3T. Am J Roentgenol 2010 194 794-798
-
(2010)
Am J Roentgenol
, vol.194
, pp. 794-798
-
-
Lanzman, R.S.1
Kröpil, P.2
Schmitt, P.3
-
41
-
-
35348941935
-
MRI of the kidney-state of the art
-
Nikken J J., Krestin G P. MRI of the kidney-state of the art. Eur Radiol 2007 17 2780-2793, Review
-
(2007)
Eur Radiol
, vol.17
, pp. 2780-2793
-
-
Nikken, J.J.1
Krestin, G.P.2
-
42
-
-
0031980987
-
Potential renal transplant donors: Evaluation with gadolinium-enhanced MR angiography and MR urography
-
Low R N., Martinez A G., Steinberg S M. et al. Potential renal transplant donors: evaluation with gadolinium-enhanced MR angiography and MR urography. Radiology 1998 207 165-172
-
(1998)
Radiology
, vol.207
, pp. 165-172
-
-
Low, R.N.1
Martinez, A.G.2
Steinberg, S.M.3
-
43
-
-
77955603511
-
Contrast-enhanced MRA of the renal and aorto-iliac-femoral arteries: Comparison of gadobenate dimeglumine and gadofosveset trisodium
-
Aug 2010 [epub ahead of print]
-
Iezzi R, Soulez G, Thurnher S et al. Contrast-enhanced MRA of the renal and aorto-iliac-femoral arteries: Comparison of gadobenate dimeglumine and gadofosveset trisodium. Eur J Radiology 2009 Aug 2010 [epub ahead of print]
-
(2009)
Eur J Radiology
-
-
Iezzi, R.1
Soulez, G.2
Thurnher, S.3
-
44
-
-
73349126747
-
High-resolution steady-state magnetic resonance angiography of the carotid artery: Are intravascular agents necessary?
-
Anzidei M, Napoli A, Marincola B C. et al. High-resolution steady-state magnetic resonance angiography of the carotid artery: Are intravascular agents necessary? Invest Radiol 2009 44 784-792
-
(2009)
Invest Radiol
, vol.44
, pp. 784-792
-
-
Anzidei, M.1
Napoli, A.2
Marincola, B.C.3
-
45
-
-
69949136812
-
Liver vessel enhancement by Gd-BOPTA and Gd-EOB-DTPA: A comparison in healthy volunteers
-
Brismar T B., Dahlstrom N, Edsborg N et al. Liver vessel enhancement by Gd-BOPTA and Gd-EOB-DTPA: a comparison in healthy volunteers. Acta Radiol 2009 50 709-715
-
(2009)
Acta Radiol
, vol.50
, pp. 709-715
-
-
Brismar, T.B.1
Dahlstrom, N.2
Edsborg, N.3
-
46
-
-
53849106487
-
Intraindividual comparison of image quality in MR urography at 1.5 and 3 tesla in an animal model
-
Regier M, Nolte-Ernsting C, Adam G et al. Intraindividual comparison of image quality in MR urography at 1.5 and 3 tesla in an animal model. Fortschr Röntgenstr 2008 180 915-921
-
(2008)
Fortschr Röntgenstr
, vol.180
, pp. 915-921
-
-
Regier, M.1
Nolte-Ernsting, C.2
Adam, G.3
-
47
-
-
36248964851
-
Preoperative Evaluation of Potential Living Related Kidney Donors with High-Spatial -Resolution Magnetic Resonance (MR) Angiography at 3 Tesla
-
Kramer U, Thiel C, Seeger A et al. Preoperative Evaluation of Potential Living Related Kidney Donors with High-Spatial -Resolution Magnetic Resonance (MR) Angiography at 3 Tesla. Invest Radiol 2007 42 747-755
-
(2007)
Invest Radiol
, vol.42
, pp. 747-755
-
-
Kramer, U.1
Thiel, C.2
Seeger, A.3
-
48
-
-
21044442108
-
The feasibility of spatial high-resolution magnetic resonance angiography (MRA) of the renal arteries at 3.0T
-
Michaely H J., Nael K, Schoenberg S O. et al. The feasibility of spatial high-resolution magnetic resonance angiography (MRA) of the renal arteries at 3.0T. Fortschr Röntgenstr 2005 177 800-804
-
(2005)
Fortschr Röntgenstr
, vol.177
, pp. 800-804
-
-
Michaely, H.J.1
Nael, K.2
Schoenberg, S.O.3
|