메뉴 건너뛰기




Volumn 26, Issue 9, 2010, Pages 615-622

The use of the vacuum-assisted closure in microsurgical reconstruction revisited: Application in the reconstruction of the posttraumatic lower extremity

Author keywords

free flap surgery; Negative pressure wound therapy; reconstructive surgery

Indexed keywords

ADOLESCENT; ADULT; AGED; ARTICLE; CHILD; CLINICAL ARTICLE; DOPPLER FLOWMETRY; FEMALE; FREE TISSUE GRAFT; GRAFT FAILURE; HUMAN; LEG; MALE; MICROSURGERY; PERIPHERAL VASCULAR DISEASE; POSTOPERATIVE CARE; POSTTRAUMATIC COMPLICATION; PRIORITY JOURNAL; SCHOOL CHILD; SOFT TISSUE DEFECT; VACUUM ASSISTED CLOSURE;

EID: 78049315351     PISSN: 0743684X     EISSN: 10988947     Source Type: Journal    
DOI: 10.1055/s-0030-1267378     Document Type: Article
Times cited : (27)

References (24)
  • 1
    • 56249148216 scopus 로고    scopus 로고
    • Oncosurgical and reconstructive concepts in the treatment of soft tissue sarcomas: A retrospective analysis
    • Bannasch H, Haivas I, Momeni A, Stark G B. Oncosurgical and reconstructive concepts in the treatment of soft tissue sarcomas: a retrospective analysis. Arch Orthop Trauma Surg 2009 129 43-49
    • (2009) Arch Orthop Trauma Surg , vol.129 , pp. 43-49
    • Bannasch, H.1    Haivas, I.2    Momeni, A.3    Stark, G.B.4
  • 2
    • 33750818948 scopus 로고    scopus 로고
    • The thoracodorsal artery perforator flap with a vascularized scapular segment for reconstruction of a composite lower extremity defect
    • Momeni A, Krischak S, Bannasch H. The thoracodorsal artery perforator flap with a vascularized scapular segment for reconstruction of a composite lower extremity defect. Microsurgery 2006 26 515-518
    • (2006) Microsurgery , vol.26 , pp. 515-518
    • Momeni, A.1    Krischak, S.2    Bannasch, H.3
  • 3
    • 58149396463 scopus 로고    scopus 로고
    • The semi-open approach to the gracilis muscle flap: Aesthetic refinements in gracilis muscle harvest
    • Momeni A, Bannasch H. The semi-open approach to the gracilis muscle flap: aesthetic refinements in gracilis muscle harvest. J Reconstr Microsurg 2009 25 63-67
    • (2009) J Reconstr Microsurg , vol.25 , pp. 63-67
    • Momeni, A.1    Bannasch, H.2
  • 4
    • 70349274453 scopus 로고    scopus 로고
    • The free gracilis perforator flap: Is a perforator flap really indicated in the case of the gracilis flap?
    • author reply 1009-1010
    • Momeni A, Bannasch H, Lee G K. The free gracilis perforator flap: is a perforator flap really indicated in the case of the gracilis flap? Plast Reconstr Surg 2009 124 1008-1009 author reply 1009-1010
    • (2009) Plast Reconstr Surg , vol.124 , pp. 1008-1009
    • Momeni, A.1    Bannasch, H.2    Lee, G.K.3
  • 5
    • 0027299338 scopus 로고
    • Monitoring techniques for the detection of flow failure in the postoperative period
    • Neligan P C. Monitoring techniques for the detection of flow failure in the postoperative period. Microsurgery 1993 14 162-164
    • (1993) Microsurgery , vol.14 , pp. 162-164
    • Neligan, P.C.1
  • 6
    • 53049107782 scopus 로고    scopus 로고
    • A critical evaluation of the concomitant use of the implantable Doppler probe and the Vacuum Assisted Closure system in free tissue transfer
    • Bannasch H, Iblher N, Penna V et al. A critical evaluation of the concomitant use of the implantable Doppler probe and the Vacuum Assisted Closure system in free tissue transfer. Microsurgery 2008 28 412-416
    • (2008) Microsurgery , vol.28 , pp. 412-416
    • Bannasch, H.1    Iblher, N.2    Penna, V.3
  • 7
    • 0021241174 scopus 로고
    • Monitors for the cutaneous microcirculation
    • Jones B M. Monitors for the cutaneous microcirculation. Plast Reconstr Surg 1984 73 843-850
    • (1984) Plast Reconstr Surg , vol.73 , pp. 843-850
    • Jones, B.M.1
  • 8
    • 0028140059 scopus 로고
    • Implantable venous Doppler microvascular monitoring: Laboratory investigation and clinical results
    • Swartz W M., Izquierdo R, Miller M J. Implantable venous Doppler microvascular monitoring: laboratory investigation and clinical results. Plast Reconstr Surg 1994 93 152-163
    • (1994) Plast Reconstr Surg , vol.93 , pp. 152-163
    • Swartz, W.M.1    Izquierdo, R.2    Miller, M.J.3
  • 9
    • 0023835477 scopus 로고
    • Direct monitoring of microvascular anastomoses with the 20-MHz ultrasonic Doppler probe: An experimental and clinical study
    • Swartz W M., Jones N F., Cherup L, Klein A. Direct monitoring of microvascular anastomoses with the 20-MHz ultrasonic Doppler probe: an experimental and clinical study. Plast Reconstr Surg 1988 81 149-161
    • (1988) Plast Reconstr Surg , vol.81 , pp. 149-161
    • Swartz, W.M.1    Jones, N.F.2    Cherup, L.3    Klein, A.4
  • 10
    • 33645054594 scopus 로고    scopus 로고
    • Topical negative pressure (TNP): The evolution of a novel wound therapy
    • Banwell P, Téot L. Topical negative pressure (TNP): the evolution of a novel wound therapy. J Tissue Viability 2006 16 16-24
    • (2006) J Tissue Viability , vol.16 , pp. 16-24
    • Banwell, P.1    Téot, L.2
  • 11
    • 34247500747 scopus 로고    scopus 로고
    • Securing skin grafts to microvascular free flaps using the vacuum-assisted closure (VAC) device
    • Hanasono M M., Skoracki R J. Securing skin grafts to microvascular free flaps using the vacuum-assisted closure (VAC) device. Ann Plast Surg 2007 58 573-576
    • (2007) Ann Plast Surg , vol.58 , pp. 573-576
    • Hanasono, M.M.1    Skoracki, R.J.2
  • 12
    • 0024414879 scopus 로고
    • Reconstruction of the lower extremity with microvascular free flaps: A 10-year experience with 304 consecutive cases
    • Khouri R K., Shaw W W. Reconstruction of the lower extremity with microvascular free flaps: a 10-year experience with 304 consecutive cases. J Trauma 1989 29 1086-1094
    • (1989) J Trauma , vol.29 , pp. 1086-1094
    • Khouri, R.K.1    Shaw, W.W.2
  • 13
    • 0029785296 scopus 로고    scopus 로고
    • The fate of lower extremities with failed free flaps
    • discussion 841-842
    • Benacquista T, Kasabian A K., Karp N S. The fate of lower extremities with failed free flaps. Plast Reconstr Surg 1996 98 834-840 discussion 841-842
    • (1996) Plast Reconstr Surg , vol.98 , pp. 834-840
    • Benacquista, T.1    Kasabian, A.K.2    Karp, N.S.3
  • 16
    • 33750379556 scopus 로고    scopus 로고
    • Effectiveness of negative pressure closure in the integration of split thickness skin grafts: A randomized, double-masked, controlled trial
    • Llanos S, Danilla S, Barraza C et al. Effectiveness of negative pressure closure in the integration of split thickness skin grafts: a randomized, double-masked, controlled trial. Ann Surg 2006 244 700-705
    • (2006) Ann Surg , vol.244 , pp. 700-705
    • Llanos, S.1    Danilla, S.2    Barraza, C.3
  • 17
    • 0030940249 scopus 로고    scopus 로고
    • Vacuum-assisted closure: A new method for wound control and treatment: Clinical experience
    • discussion 577
    • Argenta L C., Morykwas M J. Vacuum-assisted closure: a new method for wound control and treatment: clinical experience. Ann Plast Surg 1997 38 563-576 discussion 577
    • (1997) Ann Plast Surg , vol.38 , pp. 563-576
    • Argenta, L.C.1    Morykwas, M.J.2
  • 18
    • 0031006371 scopus 로고    scopus 로고
    • Vacuum-assisted closure: A new method for wound control and treatment: Animal studies and basic foundation
    • Morykwas M J., Argenta L C., Shelton-Brown E I., McGuirt W. Vacuum-assisted closure: a new method for wound control and treatment: animal studies and basic foundation. Ann Plast Surg 1997 38 553-562
    • (1997) Ann Plast Surg , vol.38 , pp. 553-562
    • Morykwas, M.J.1    Argenta, L.C.2    Shelton-Brown, E.I.3    McGuirt, W.4
  • 19
    • 0031900329 scopus 로고    scopus 로고
    • The effect of an implantable Doppler probe on the salvage of microvascular tissue transplants
    • discussion 1274-1275
    • Kind G M., Buntic R F., Buncke G M., Cooper T M., Siko P P., Buncke H J. Jr. The effect of an implantable Doppler probe on the salvage of microvascular tissue transplants. Plast Reconstr Surg 1998 101 1268-1273 discussion 1274-1275
    • (1998) Plast Reconstr Surg , vol.101 , pp. 1268-1273
    • Kind, G.M.1    Buntic, R.F.2    Buncke, G.M.3    Cooper, T.M.4    Siko, P.P.5    Buncke Jr., H.J.6
  • 20
    • 33746824687 scopus 로고    scopus 로고
    • Monitoring buried free flaps: Limitations of the implantable Doppler and use of color duplex sonography as a confirmatory test
    • discussion 114-115
    • Rosenberg J J., Fornage B D., Chevray P M. Monitoring buried free flaps: limitations of the implantable Doppler and use of color duplex sonography as a confirmatory test. Plast Reconstr Surg 2006 118 109-113 discussion 114-115
    • (2006) Plast Reconstr Surg , vol.118 , pp. 109-113
    • Rosenberg, J.J.1    Fornage, B.D.2    Chevray, P.M.3
  • 21
    • 0030770246 scopus 로고    scopus 로고
    • The functional outcome of lower-extremity fractures with vascular injury
    • Lin C H., Wei F C., Levin L S., Su J I., Yeh W L. The functional outcome of lower-extremity fractures with vascular injury. J Trauma 1997 43 480-485
    • (1997) J Trauma , vol.43 , pp. 480-485
    • Lin, C.H.1    Wei, F.C.2    Levin, L.S.3    Su, J.I.4    Yeh, W.L.5
  • 22
    • 68049112204 scopus 로고    scopus 로고
    • Dissociation of pentameric to monomeric C-reactive protein on activated platelets localizes inflammation to atherosclerotic plaques
    • Eisenhardt S U., Habersberger J, Murphy A et al. Dissociation of pentameric to monomeric C-reactive protein on activated platelets localizes inflammation to atherosclerotic plaques. Circ Res 2009 105 128-137
    • (2009) Circ Res , vol.105 , pp. 128-137
    • Eisenhardt, S.U.1    Habersberger, J.2    Murphy, A.3
  • 23
    • 38849132141 scopus 로고    scopus 로고
    • Subtractive single-chain antibody (scFv) phage-display: Tailoring phage-display for high specificity against function-specific conformations of cell membrane molecules
    • Eisenhardt S U., Schwarz M, Bassler N, Peter K. Subtractive single-chain antibody (scFv) phage-display: tailoring phage-display for high specificity against function-specific conformations of cell membrane molecules. Nat Protocols 2007 2 3063-3073
    • (2007) Nat Protocols , vol.2 , pp. 3063-3073
    • Eisenhardt, S.U.1    Schwarz, M.2    Bassler, N.3    Peter, K.4
  • 24
    • 34147152321 scopus 로고    scopus 로고
    • Generation of activation-specific human anti-alphaMbeta2 single-chain antibodies as potential diagnostic tools and therapeutic agents
    • Eisenhardt S U., Schwarz M, Schallner N et al. Generation of activation-specific human anti-alphaMbeta2 single-chain antibodies as potential diagnostic tools and therapeutic agents. Blood 2007 109 3521-3528
    • (2007) Blood , vol.109 , pp. 3521-3528
    • Eisenhardt, S.U.1    Schwarz, M.2    Schallner, N.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.