메뉴 건너뛰기




Volumn 78, Issue 4, 2010, Pages 1219-1226

Breath-hold target localization with simultaneous kilovoltage/megavoltage cone-beam computed tomography and fast reconstruction

Author keywords

CBCT; cone beam computed tomography; fast tomographic reconstruction; Image guidance; kilovoltage megavoltage imaging; treatment verification

Indexed keywords

CBCT; CONE-BEAM COMPUTED TOMOGRAPHY; FAST TOMOGRAPHIC RECONSTRUCTION; IMAGE GUIDANCES; KILOVOLTAGE/MEGAVOLTAGE IMAGING; TREATMENT VERIFICATION;

EID: 77958485192     PISSN: 03603016     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.ijrobp.2010.01.030     Document Type: Article
Times cited : (23)

References (29)
  • 1
    • 33745488460 scopus 로고    scopus 로고
    • IMRT: A review and preview
    • T. Bortfeld IMRT: A review and preview Phys Med Biol 51 2006 R363 R379
    • (2006) Phys Med Biol , vol.51
    • Bortfeld, T.1
  • 2
    • 0033770394 scopus 로고    scopus 로고
    • Conformal radiotherapy and intensity-modulated radiotherapy
    • M. Tubiana, and F. Eschwge Conformal radiotherapy and intensity-modulated radiotherapy Acta Oncol 39 2000 555 567
    • (2000) Acta Oncol , vol.39 , pp. 555-567
    • Tubiana, M.1    Eschwge, F.2
  • 3
    • 1642576015 scopus 로고    scopus 로고
    • The relationship of increasing radiotherapy dose to reduced distant metastases and mortality in men with prostate cancer
    • R. Jacob, A.L. Hanlon, and E.M. Horwitz The relationship of increasing radiotherapy dose to reduced distant metastases and mortality in men with prostate cancer Cancer 100 2004 538 543
    • (2004) Cancer , vol.100 , pp. 538-543
    • Jacob, R.1    Hanlon, A.L.2    Horwitz, E.M.3
  • 4
    • 34248329093 scopus 로고    scopus 로고
    • Optimization of extracranial stereotactic radiation therapy of small lung lesions using accurate dose calculation algorithms
    • B. Dobler, C. Walter, and A. Knopf Optimization of extracranial stereotactic radiation therapy of small lung lesions using accurate dose calculation algorithms Radiat Oncol 1 2006 45
    • (2006) Radiat Oncol , vol.1 , pp. 45
    • Dobler, B.1    Walter, C.2    Knopf, A.3
  • 5
    • 0035500881 scopus 로고    scopus 로고
    • Computed tomography-guided frameless stereotactic radiotherapy for stage i non-small-cell lung cancer: A 5-year experience
    • M. Uematsu, A. Shioda, and A. Suda Computed tomography-guided frameless stereotactic radiotherapy for stage I non-small-cell lung cancer: A 5-year experience Int J Radiat Oncol Biol Phys 51 2001 666 670
    • (2001) Int J Radiat Oncol Biol Phys , vol.51 , pp. 666-670
    • Uematsu, M.1    Shioda, A.2    Suda, A.3
  • 6
    • 0034212293 scopus 로고    scopus 로고
    • Set-up error in radiotherapy: On-line correction using electronic kilovoltage and megavoltage radiographs
    • L. Pisani, D. Lockman, and D. Jaffray Set-up error in radiotherapy: On-line correction using electronic kilovoltage and megavoltage radiographs Int J Radiat Oncol Biol Phys 47 2000 825 839
    • (2000) Int J Radiat Oncol Biol Phys , vol.47 , pp. 825-839
    • Pisani, L.1    Lockman, D.2    Jaffray, D.3
  • 7
    • 0028230872 scopus 로고
    • Comprehensive QA for radiation oncology: Report of AAPM Radiation Therapy Committee Task Group 40
    • G.J. Kutcher, L. Coia, and M. Gillin Comprehensive QA for radiation oncology: Report of AAPM Radiation Therapy Committee Task Group 40 Med Phys 21 1994 581 618
    • (1994) Med Phys , vol.21 , pp. 581-618
    • Kutcher, G.J.1    Coia, L.2    Gillin, M.3
  • 8
    • 0035018405 scopus 로고    scopus 로고
    • Clinical use of electronic portal imaging: Report of AAPM Radiation Therapy Committee Task Group 58
    • M.G. Herman, J.M. Balter, and D.A. Jaffray Clinical use of electronic portal imaging: Report of AAPM Radiation Therapy Committee Task Group 58 Med Phys 28 2001 712 737
    • (2001) Med Phys , vol.28 , pp. 712-737
    • Herman, M.G.1    Balter, J.M.2    Jaffray, D.A.3
  • 9
    • 0037359535 scopus 로고    scopus 로고
    • CT image-guided intensity-modulated therapy for paraspinal tumors using stereotactic immobilization
    • K.M. Yenice, D.M. Lovelock, and M.A. Hunt CT image-guided intensity-modulated therapy for paraspinal tumors using stereotactic immobilization Int J Radiat Oncol Biol Phys 55 2003 583 593
    • (2003) Int J Radiat Oncol Biol Phys , vol.55 , pp. 583-593
    • Yenice, K.M.1    Lovelock, D.M.2    Hunt, M.A.3
  • 10
    • 34547828780 scopus 로고    scopus 로고
    • Four-dimensional treatment planning for stereotactic body radiotherapy
    • M. Guckenberger, J. Wilbert, and T. Krieger Four-dimensional treatment planning for stereotactic body radiotherapy Int J Radiat Oncol Biol Phys 69 2007 276 285
    • (2007) Int J Radiat Oncol Biol Phys , vol.69 , pp. 276-285
    • Guckenberger, M.1    Wilbert, J.2    Krieger, T.3
  • 11
    • 39749101847 scopus 로고    scopus 로고
    • Accuracy of ultrasound-based (BAT) prostate-repositioning: A three-dimensional on-line fiducial-based assessment with cone-beam computed tomography
    • J. Boda-Heggemann, F.M. Koehler, and B. Kuepper Accuracy of ultrasound-based (BAT) prostate-repositioning: A three-dimensional on-line fiducial-based assessment with cone-beam computed tomography Int J Radiat Oncol Biol Phys 70 2008 1247 1255
    • (2008) Int J Radiat Oncol Biol Phys , vol.70 , pp. 1247-1255
    • Boda-Heggemann, J.1    Koehler, F.M.2    Kuepper, B.3
  • 12
    • 33646000817 scopus 로고    scopus 로고
    • Digital tomosynthesis with an on-board kilovoltage imaging device
    • D.J. Godfrey, F.F. Yin, and M. Oldham Digital tomosynthesis with an on-board kilovoltage imaging device Int J Radiat Oncol Biol Phys 65 2006 8 15
    • (2006) Int J Radiat Oncol Biol Phys , vol.65 , pp. 8-15
    • Godfrey, D.J.1    Yin, F.F.2    Oldham, M.3
  • 13
    • 0036680147 scopus 로고    scopus 로고
    • Flat-panel cone-beam computed tomography for image guided radiation therapy
    • D.A. Jaffray, J.H. Siewerdsen, and J.W. Wong Flat-panel cone-beam computed tomography for image guided radiation therapy Int J Radiat Oncol Biol Phys 53 2002 1337 1349
    • (2002) Int J Radiat Oncol Biol Phys , vol.53 , pp. 1337-1349
    • Jaffray, D.A.1    Siewerdsen, J.H.2    Wong, J.W.3
  • 15
    • 0028820553 scopus 로고    scopus 로고
    • Dual-beam imaging for online verification of radiotherapy field placement
    • D.A. Jaffray, K. Chawla, and C. Yu Dual-beam imaging for online verification of radiotherapy field placement Int J Radiat Oncol Biol Phys 33 2002 1273 1280
    • (2002) Int J Radiat Oncol Biol Phys , vol.33 , pp. 1273-1280
    • Jaffray, D.A.1    Chawla, K.2    Yu, C.3
  • 16
    • 0036852441 scopus 로고    scopus 로고
    • Methods for improving limited field-of-view radiotherapy reconstructions using imperfect a priori images
    • K.J. Ruchala, G.H. Olivera, and J.M. Kapatoes Methods for improving limited field-of-view radiotherapy reconstructions using imperfect a priori images Med Phys 29 2002 2590 2605
    • (2002) Med Phys , vol.29 , pp. 2590-2605
    • Ruchala, K.J.1    Olivera, G.H.2    Kapatoes, J.M.3
  • 17
    • 33748319634 scopus 로고    scopus 로고
    • Low-dose megavoltage cone-beam computed tomography for lung tumors using a high-efficiency image receptor
    • J. Sillanpaa, J. Chang, and G. Mageras Low-dose megavoltage cone-beam computed tomography for lung tumors using a high-efficiency image receptor Med Phys 33 2006 3489 3497
    • (2006) Med Phys , vol.33 , pp. 3489-3497
    • Sillanpaa, J.1    Chang, J.2    Mageras, G.3
  • 19
    • 34247565210 scopus 로고    scopus 로고
    • Patient dose considerations for routine megavoltage cone-beam CT imaging
    • O. Morin, A. Gillis, and M. Descovich Patient dose considerations for routine megavoltage cone-beam CT imaging Med Phys 34 2007 1819 1827
    • (2007) Med Phys , vol.34 , pp. 1819-1827
    • Morin, O.1    Gillis, A.2    Descovich, M.3
  • 20
    • 33644932630 scopus 로고    scopus 로고
    • Megavoltage cone-beam CT: System description and clinical applications
    • O. Morin, A. Gillis, and J. Chen Megavoltage cone-beam CT: System description and clinical applications Med Dosim 31 2006 51 61
    • (2006) Med Dosim , vol.31 , pp. 51-61
    • Morin, O.1    Gillis, A.2    Chen, J.3
  • 21
    • 25644448237 scopus 로고    scopus 로고
    • A technique for on-board CT reconstruction using both kilovoltage and megavoltage beam projections for 3D treatment verification
    • F.F. Yin, H. Guan, and W. Lu A technique for on-board CT reconstruction using both kilovoltage and megavoltage beam projections for 3D treatment verification Med Phys 32 2005 2819 2826
    • (2005) Med Phys , vol.32 , pp. 2819-2826
    • Yin, F.F.1    Guan, H.2    Lu, W.3
  • 23
    • 33744823315 scopus 로고    scopus 로고
    • Patient dose from kilovoltage cone beam computed tomography imaging in radiation therapy
    • M.K. Islam, T.G. Purdie, and B.D. Norrlinger Patient dose from kilovoltage cone beam computed tomography imaging in radiation therapy Med Phys 33 2006 1573 1582
    • (2006) Med Phys , vol.33 , pp. 1573-1582
    • Islam, M.K.1    Purdie, T.G.2    Norrlinger, B.D.3
  • 25
    • 34748901307 scopus 로고    scopus 로고
    • GPU-based streaming architectures for fast cone-beam CT image reconstruction and demons deformable registration
    • G.C. Sharp, N. Kandasamy, and H. Singh GPU-based streaming architectures for fast cone-beam CT image reconstruction and demons deformable registration Phys Med Biol 52 2007 771 783
    • (2007) Phys Med Biol , vol.52 , pp. 771-783
    • Sharp, G.C.1    Kandasamy, N.2    Singh, H.3
  • 27
    • 34548363876 scopus 로고    scopus 로고
    • Minimizing image noise in on-board CT reconstruction using both kilovoltage and megavoltage beam projections
    • J. Zhang, and F.F. Yin Minimizing image noise in on-board CT reconstruction using both kilovoltage and megavoltage beam projections Med Phys 34 2007 3665 3673
    • (2007) Med Phys , vol.34 , pp. 3665-3673
    • Zhang, J.1    Yin, F.F.2
  • 28
    • 0035989949 scopus 로고    scopus 로고
    • A performance comparison of flat-panel imager-based MV and kV cone-beam CT
    • B.A. Groh, J.H. Siewerdsen, and D.G. Drake A performance comparison of flat-panel imager-based MV and kV cone-beam CT Med Phys 29 2001 967 975
    • (2001) Med Phys , vol.29 , pp. 967-975
    • Groh, B.A.1    Siewerdsen, J.H.2    Drake, D.G.3
  • 29
    • 17844379967 scopus 로고    scopus 로고
    • Respiratory correlated cone beam CT
    • J.J. Sonke, L. Zijp, and P. Remeijer Respiratory correlated cone beam CT Med Phys 32 2005 176 186
    • (2005) Med Phys , vol.32 , pp. 176-186
    • Sonke, J.J.1    Zijp, L.2    Remeijer, P.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.