-
1
-
-
1442360627
-
Analysis of screw placement relativeto the aorta and spinal canal following anterior instrumentation forthoracic idiopathic scoliosis
-
Sucato DJ, Kassab F, Dempsey M. Analysis of screw placement relativeto the aorta and spinal canal following anterior instrumentation forthoracic idiopathic scoliosis. Spine. 2004;29: 554-559.
-
(2004)
Spine
, vol.29
, pp. 554-559
-
-
Sucato, D.J.1
Kassab, F.2
Dempsey, M.3
-
2
-
-
33745712005
-
Screw position after doublerodanterior spinal fusion in idiopathic scoliosis: An evaluation usingcomputerized tomography
-
Huitema GC, van Rhijn LW, van Ooij A. Screw position after doublerodanterior spinal fusion in idiopathic scoliosis: an evaluation usingcomputerized tomography. Spine. 2006;31: 1734-1739.
-
(2006)
Spine
, vol.31
, pp. 1734-1739
-
-
Huitema, G.C.1
Van Rhijn, L.W.2
Van Ooij, A.3
-
3
-
-
34548570922
-
The anatomical relationshipbetween the aorta and the thoracic vertebral bodies and its importance inthe placement of the screw in thoracoscopic correction of scoliosis
-
Qiu Y, He YX, Wang B, Zhu F, Wang WJ. The anatomical relationshipbetween the aorta and the thoracic vertebral bodies and its importance inthe placement of the screw in thoracoscopic correction of scoliosis. EurSpine J. 2007;16: 1367-1372.
-
(2007)
EurSpine J
, vol.16
, pp. 1367-1372
-
-
Qiu, Y.1
He, Y.X.2
Wang, B.3
Zhu, F.4
Wang, W.J.5
-
4
-
-
33745697975
-
The position of the aortarelative to the spine before and after anterior instrumentation in rightthoracic scoliosis
-
Bullmann V, Fallenberg EM, Meier N, et al. The position of the aortarelative to the spine before and after anterior instrumentation in rightthoracic scoliosis. Spine. 2006;31: 1706-1713.
-
(2006)
Spine
, vol.31
, pp. 1706-1713
-
-
Bullmann, V.1
Fallenberg, E.M.2
Meier, N.3
-
5
-
-
33750321099
-
Endovascular graft for late iatrogenicvascular complication after anterior spinal instrumentation: A case report
-
Been HD, Kerkhoffs GM, Balm R. Endovascular graft for late iatrogenicvascular complication after anterior spinal instrumentation: a case report.Spine. 2006;31: 856-858.
-
(2006)
Spine
, vol.31
, pp. 856-858
-
-
Been, H.D.1
Kerkhoffs, G.M.2
Balm, R.3
-
6
-
-
0035486958
-
Delayed aortic rupture caused by an implanted anterior spinal device.Case report
-
Ohnishi T, Neo M, Matsushita M, Komeda M, Koyama T, Nakamura T.Delayed aortic rupture caused by an implanted anterior spinal device.Case report. J Neurosurg. 2001;95: 253-256.
-
(2001)
J Neurosurg
, vol.95
, pp. 253-256
-
-
Ohnishi, T.1
Neo, M.2
Matsushita, M.3
Komeda, M.4
Koyama, T.5
Nakamura, T.6
-
7
-
-
45949096791
-
Pseudoaneurysm of the thoracoabdominalaorta caused by a severe migration of an anterior spinaldevice
-
Higashino K, Katoh S, Sairyo K, et al. Pseudoaneurysm of the thoracoabdominalaorta caused by a severe migration of an anterior spinaldevice. Spine J. 2007;8: 696-699.
-
(2007)
Spine J
, vol.8
, pp. 696-699
-
-
Higashino, K.1
Katoh, S.2
Sairyo, K.3
-
8
-
-
0027366735
-
Penetration ofa screw into the thoracic aorta in anterior spinal instrumentation. A casereport
-
Matsuzaki H, Tokuhashi Y, Wakabayashi K, Kitamura S. Penetration ofa screw into the thoracic aorta in anterior spinal instrumentation. A casereport. Spine. 1993;18: 2327-2331.
-
(1993)
Spine
, vol.18
, pp. 2327-2331
-
-
Matsuzaki, H.1
Tokuhashi, Y.2
Wakabayashi, K.3
Kitamura, S.4
-
9
-
-
42749084832
-
Delayed presentation of aortic injury bypedicle screws: Report of two cases and review of the literature
-
Kakkos SK, Shepard AD. Delayed presentation of aortic injury bypedicle screws: report of two cases and review of the literature. J VascSurg. 2008;47: 1074-1082.
-
(2008)
J VascSurg
, vol.47
, pp. 1074-1082
-
-
Kakkos, S.K.1
Shepard, A.D.2
-
10
-
-
0035153601
-
False aneurysm of the thoracic aortaassociated with an aorto-chest wall fistula after spinal instrumentation
-
Choi JB, Han JO, Jeong JW. False aneurysm of the thoracic aortaassociated with an aorto-chest wall fistula after spinal instrumentation.J Trauma. 2001;50: 140-143.
-
(2001)
J Trauma
, vol.50
, pp. 140-143
-
-
Choi, J.B.1
Han, J.O.2
Jeong, J.W.3
-
11
-
-
0032891285
-
Iatrogenic upper abdominal aorticinjury with pseudoaneurysm during spinal surgery
-
Lim KE, Fan KF, Wong YC, Hsu YY. Iatrogenic upper abdominal aorticinjury with pseudoaneurysm during spinal surgery. J Trauma. 1999;46: 729-731.
-
(1999)
J Trauma
, vol.46
, pp. 729-731
-
-
Lim, K.E.1
Fan, K.F.2
Wong, Y.C.3
Hsu, Y.Y.4
-
12
-
-
50649111378
-
Delayedperforation of the aorta by a thoracic pedicle screw
-
Wegener B, Birkenmaier C, Fottner A, Jansson V, Dürr HR. Delayedperforation of the aorta by a thoracic pedicle screw. Eur Spine J.2008;17: S351-SS.
-
(2008)
Eur Spine J
, vol.17
-
-
Wegener, B.1
Birkenmaier, C.2
Fottner, A.3
Jansson, V.4
Dürr, H.R.5
-
13
-
-
0029098570
-
Placement of pediclescrews in the thoracic spine Part II: An Anatomical and Radiographicassessment
-
Vaccaro AR, Rizzolo SJ, Balderston RA, et al. Placement of pediclescrews in the thoracic spine. Part II: an anatomical and radiographicassessment. J Bone Joint Surg. 1995;77: 1200-1206.
-
(1995)
J Bone Joint Surg
, vol.77
, pp. 1200-1206
-
-
Vaccaro, A.R.1
Rizzolo, S.J.2
Balderston, R.A.3
-
14
-
-
33750052901
-
Miniature robotic guidancefor pedicle screw placement in posterior spinal fusion: Early clinicalexperience with the Spine Assist
-
Sukovich W, Brink-Danan S, Hardenbrook M. Miniature robotic guidancefor pedicle screw placement in posterior spinal fusion: early clinicalexperience with the Spine Assist. Int J Med Robot. 2006;2: 114-122.
-
(2006)
Int J Med Robot
, vol.2
, pp. 114-122
-
-
Sukovich, W.1
Brink-Danan, S.2
Hardenbrook, M.3
-
15
-
-
34447526747
-
Computed tomography-guidedpercutaneous facet screw fixation in the lumbar spine. Technical note
-
Kang HY, Lee SH, Jeon SH, Shin SW. Computed tomography-guidedpercutaneous facet screw fixation in the lumbar spine. Technical note.J Neurosurg Spine. 2007;7: 95-98.
-
(2007)
J Neurosurg Spine
, vol.7
, pp. 95-98
-
-
Kang, H.Y.1
Lee, S.H.2
Jeon, S.H.3
Shin, S.W.4
-
16
-
-
0036719371
-
Vascular injury complicating lumbar disc surgery
-
Papadoulas S, Konstantinou D, Kourea HP, Kritikos N, Haftouras N,Tsolakis JA. Vascular injury complicating lumbar disc surgery. Asystematic review. Eur J Vasc Endovasc Surg. 2002;24: 189-195.
-
(2002)
Asystematic Review Eur J Vasc Endovasc Surg
, vol.24
, pp. 189-195
-
-
Papadoulas, S.1
Konstantinou, D.2
Kourea, H.P.3
Kritikos, N.4
Haftouras Ntsolakis, J.A.5
-
17
-
-
0020631339
-
Ruptured lumbar arterypseudoaneyrysm: An unusual cause of retroperitoneal haemorrhage
-
Stewart JR, Barth KH, Williams GM. Ruptured lumbar arterypseudoaneyrysm: an unusual cause of retroperitoneal haemorrhage.Surgery. 1983;94: 592-594.
-
(1983)
Surgery
, vol.94
, pp. 592-594
-
-
Stewart, J.R.1
Barth, K.H.2
Williams, G.M.3
-
18
-
-
0037291592
-
Arterial complications following anterior lumbar interbody fusion: Reportof eight cases
-
Kulkarni SS, Lowery GL, Ross RE, Ravi Sankar K, Lykomitros V.Arterial complications following anterior lumbar interbody fusion: reportof eight cases. Eur Spine J. 2003;12: 48-54.
-
(2003)
Eur Spine J
, vol.12
, pp. 48-54
-
-
Kulkarni, S.S.1
Lowery, G.L.2
Ross, R.E.3
Ravi Sankar, K.4
Lykomitros, V.5
-
19
-
-
0029160923
-
Thesurgical and medical perioperative complications of anterior spinalfusion surgery in the thoracic and lumbar spine in adults. A review of1223 procedures
-
Faciszewski T, Winter RB, Lonstein JE, Denis F, Johnson L. Thesurgical and medical perioperative complications of anterior spinalfusion surgery in the thoracic and lumbar spine in adults. A review of1223 procedures. Spine. 1995;20: 1592-1599.
-
(1995)
Spine
, vol.20
, pp. 1592-1599
-
-
Faciszewski, T.1
Winter, R.B.2
Lonstein, J.E.3
Denis, F.4
Johnson, L.5
-
20
-
-
39049095754
-
Strategies for prevention andoperative treatment of aortic lesions related to spinal interventions
-
Kopp R, Beisse R, Weidenhagen R, et al. Strategies for prevention andoperative treatment of aortic lesions related to spinal interventions.Spine. 2007;32: 753-760.
-
(2007)
Spine
, vol.32
, pp. 753-760
-
-
Kopp, R.1
Beisse, R.2
Weidenhagen, R.3
-
21
-
-
34548854531
-
Pseudoaneurysm of thesuperior gluteal artery during iliosacral screw fixation
-
Maled I, Velez R, Lopez R, Batalla L, Caja VL. Pseudoaneurysm of thesuperior gluteal artery during iliosacral screw fixation. Acta OrthopBelg. 2007;73: 544-547.
-
(2007)
Acta OrthopBelg
, vol.73
, pp. 544-547
-
-
Maled, I.1
Velez, R.2
Lopez, R.3
Batalla, L.4
Caja, V.L.5
-
22
-
-
0025783912
-
Extrinsic erosion of the descending aorta by a vertebral fixator
-
Sokolic J, Sosa T, Ugljen R, Biocina B, Simunic S, Slobodnjak Z.Extrinsic erosion of the descending aorta by a vertebral fixator. TexHeart Inst J. 1991;18: 136-139.
-
(1991)
TexHeart Inst J
, vol.18
, pp. 136-139
-
-
Sokolic, J.1
Sosa, T.2
Ugljen, R.3
Biocina, B.4
Simunic, S.5
Slobodnjak, Z.6
-
23
-
-
1642505540
-
Endovascular treatment of aniatrogenic thoracic aortic injury after spinal instrumentation: Case report
-
Minor ME, Morrissey NJ, Peress R, et al. Endovascular treatment of aniatrogenic thoracic aortic injury after spinal instrumentation: case report.J Vasc Surg. 2004;39: 893-896.
-
(2004)
J Vasc Surg
, vol.39
, pp. 893-896
-
-
Minor, M.E.1
Morrissey, N.J.2
Peress, R.3
-
24
-
-
0028314202
-
Thromboticocclusion of the left common iliac artery after an anterior retroperitonealapproach to the lumbar spine
-
Marsicano J, Mirovsky Y, Remer S, Bloom N, Neuwirth M. Thromboticocclusion of the left common iliac artery after an anterior retroperitonealapproach to the lumbar spine. Spine. 1994;19: 357-359.
-
(1994)
Spine
, vol.19
, pp. 357-359
-
-
Marsicano, J.1
Mirovsky, Y.2
Remer, S.3
Bloom, N.4
Neuwirth, M.5
-
25
-
-
33745051358
-
Endovascular treatment of arterial injury as an uncommon complicationafter orthopedic surgery
-
Kickuth R, Anderson S, Kocovic L, Ludwig K, Siebenrock K, Triller J.Endovascular treatment of arterial injury as an uncommon complicationafter orthopedic surgery. J Vasc Interv Radiol. 2006;17: 791-799.
-
(2006)
J Vasc Interv Radiol
, vol.17
, pp. 791-799
-
-
Kickuth, R.1
Anderson, S.2
Kocovic, L.3
Ludwig, K.4
Siebenrock, K.5
Triller, J.6
-
26
-
-
27644543217
-
Thoracic vertebral screwimpingement on the aorta in an in vivo bovine model
-
Faro FD, Farnsworth CL, Shapiro GS, et al. Thoracic vertebral screwimpingement on the aorta in an in vivo bovine model. Spine. 2005;30: 2406-2413.
-
(2005)
Spine
, vol.30
, pp. 2406-2413
-
-
Faro, F.D.1
Farnsworth, C.L.2
Shapiro, G.S.3
-
27
-
-
70449711692
-
Delayediatrogenicinjury of the thoracic aorta by an anterior spinal instrumentation
-
Lavigne F, Mascard E, Laurian C, Dubousset J, Wicart P. Delayediatrogenicinjury of the thoracic aorta by an anterior spinal instrumentation.Eur Spine J. 2009;18: 265-268.
-
(2009)
Eur Spine J
, vol.18
, pp. 265-268
-
-
Lavigne, F.1
Mascard, E.2
Laurian, C.3
Dubousset, J.4
Wicart, P.5
|