메뉴 건너뛰기




Volumn 69, Issue 4, 2010, Pages 870-874

Aortoiliac vascular injuries after misplacement of fixation screws

Author keywords

Pedicle screws; Spinal surgery; Vascular injury

Indexed keywords

ADULT; AORTA WALL; AORTAILIAC VASCULAR INJURY; ARTICLE; BLOOD VESSEL INJURY; BONE SCREW; CLINICAL ARTICLE; FEMALE; HUMAN; INFERIOR CAVA VEIN OBSTRUCTION; LIMB AMPUTATION; LUNG EMBOLISM; MALE; PRIORITY JOURNAL;

EID: 77958184894     PISSN: 00225282     EISSN: 15298809     Source Type: Journal    
DOI: 10.1097/TA.0b013e3181f0bd55     Document Type: Article
Times cited : (25)

References (27)
  • 1
    • 1442360627 scopus 로고    scopus 로고
    • Analysis of screw placement relativeto the aorta and spinal canal following anterior instrumentation forthoracic idiopathic scoliosis
    • Sucato DJ, Kassab F, Dempsey M. Analysis of screw placement relativeto the aorta and spinal canal following anterior instrumentation forthoracic idiopathic scoliosis. Spine. 2004;29: 554-559.
    • (2004) Spine , vol.29 , pp. 554-559
    • Sucato, D.J.1    Kassab, F.2    Dempsey, M.3
  • 2
    • 33745712005 scopus 로고    scopus 로고
    • Screw position after doublerodanterior spinal fusion in idiopathic scoliosis: An evaluation usingcomputerized tomography
    • Huitema GC, van Rhijn LW, van Ooij A. Screw position after doublerodanterior spinal fusion in idiopathic scoliosis: an evaluation usingcomputerized tomography. Spine. 2006;31: 1734-1739.
    • (2006) Spine , vol.31 , pp. 1734-1739
    • Huitema, G.C.1    Van Rhijn, L.W.2    Van Ooij, A.3
  • 3
    • 34548570922 scopus 로고    scopus 로고
    • The anatomical relationshipbetween the aorta and the thoracic vertebral bodies and its importance inthe placement of the screw in thoracoscopic correction of scoliosis
    • Qiu Y, He YX, Wang B, Zhu F, Wang WJ. The anatomical relationshipbetween the aorta and the thoracic vertebral bodies and its importance inthe placement of the screw in thoracoscopic correction of scoliosis. EurSpine J. 2007;16: 1367-1372.
    • (2007) EurSpine J , vol.16 , pp. 1367-1372
    • Qiu, Y.1    He, Y.X.2    Wang, B.3    Zhu, F.4    Wang, W.J.5
  • 4
    • 33745697975 scopus 로고    scopus 로고
    • The position of the aortarelative to the spine before and after anterior instrumentation in rightthoracic scoliosis
    • Bullmann V, Fallenberg EM, Meier N, et al. The position of the aortarelative to the spine before and after anterior instrumentation in rightthoracic scoliosis. Spine. 2006;31: 1706-1713.
    • (2006) Spine , vol.31 , pp. 1706-1713
    • Bullmann, V.1    Fallenberg, E.M.2    Meier, N.3
  • 5
    • 33750321099 scopus 로고    scopus 로고
    • Endovascular graft for late iatrogenicvascular complication after anterior spinal instrumentation: A case report
    • Been HD, Kerkhoffs GM, Balm R. Endovascular graft for late iatrogenicvascular complication after anterior spinal instrumentation: a case report.Spine. 2006;31: 856-858.
    • (2006) Spine , vol.31 , pp. 856-858
    • Been, H.D.1    Kerkhoffs, G.M.2    Balm, R.3
  • 6
    • 0035486958 scopus 로고    scopus 로고
    • Delayed aortic rupture caused by an implanted anterior spinal device.Case report
    • Ohnishi T, Neo M, Matsushita M, Komeda M, Koyama T, Nakamura T.Delayed aortic rupture caused by an implanted anterior spinal device.Case report. J Neurosurg. 2001;95: 253-256.
    • (2001) J Neurosurg , vol.95 , pp. 253-256
    • Ohnishi, T.1    Neo, M.2    Matsushita, M.3    Komeda, M.4    Koyama, T.5    Nakamura, T.6
  • 7
    • 45949096791 scopus 로고    scopus 로고
    • Pseudoaneurysm of the thoracoabdominalaorta caused by a severe migration of an anterior spinaldevice
    • Higashino K, Katoh S, Sairyo K, et al. Pseudoaneurysm of the thoracoabdominalaorta caused by a severe migration of an anterior spinaldevice. Spine J. 2007;8: 696-699.
    • (2007) Spine J , vol.8 , pp. 696-699
    • Higashino, K.1    Katoh, S.2    Sairyo, K.3
  • 8
    • 0027366735 scopus 로고
    • Penetration ofa screw into the thoracic aorta in anterior spinal instrumentation. A casereport
    • Matsuzaki H, Tokuhashi Y, Wakabayashi K, Kitamura S. Penetration ofa screw into the thoracic aorta in anterior spinal instrumentation. A casereport. Spine. 1993;18: 2327-2331.
    • (1993) Spine , vol.18 , pp. 2327-2331
    • Matsuzaki, H.1    Tokuhashi, Y.2    Wakabayashi, K.3    Kitamura, S.4
  • 9
    • 42749084832 scopus 로고    scopus 로고
    • Delayed presentation of aortic injury bypedicle screws: Report of two cases and review of the literature
    • Kakkos SK, Shepard AD. Delayed presentation of aortic injury bypedicle screws: report of two cases and review of the literature. J VascSurg. 2008;47: 1074-1082.
    • (2008) J VascSurg , vol.47 , pp. 1074-1082
    • Kakkos, S.K.1    Shepard, A.D.2
  • 10
    • 0035153601 scopus 로고    scopus 로고
    • False aneurysm of the thoracic aortaassociated with an aorto-chest wall fistula after spinal instrumentation
    • Choi JB, Han JO, Jeong JW. False aneurysm of the thoracic aortaassociated with an aorto-chest wall fistula after spinal instrumentation.J Trauma. 2001;50: 140-143.
    • (2001) J Trauma , vol.50 , pp. 140-143
    • Choi, J.B.1    Han, J.O.2    Jeong, J.W.3
  • 11
    • 0032891285 scopus 로고    scopus 로고
    • Iatrogenic upper abdominal aorticinjury with pseudoaneurysm during spinal surgery
    • Lim KE, Fan KF, Wong YC, Hsu YY. Iatrogenic upper abdominal aorticinjury with pseudoaneurysm during spinal surgery. J Trauma. 1999;46: 729-731.
    • (1999) J Trauma , vol.46 , pp. 729-731
    • Lim, K.E.1    Fan, K.F.2    Wong, Y.C.3    Hsu, Y.Y.4
  • 13
    • 0029098570 scopus 로고
    • Placement of pediclescrews in the thoracic spine Part II: An Anatomical and Radiographicassessment
    • Vaccaro AR, Rizzolo SJ, Balderston RA, et al. Placement of pediclescrews in the thoracic spine. Part II: an anatomical and radiographicassessment. J Bone Joint Surg. 1995;77: 1200-1206.
    • (1995) J Bone Joint Surg , vol.77 , pp. 1200-1206
    • Vaccaro, A.R.1    Rizzolo, S.J.2    Balderston, R.A.3
  • 14
    • 33750052901 scopus 로고    scopus 로고
    • Miniature robotic guidancefor pedicle screw placement in posterior spinal fusion: Early clinicalexperience with the Spine Assist
    • Sukovich W, Brink-Danan S, Hardenbrook M. Miniature robotic guidancefor pedicle screw placement in posterior spinal fusion: early clinicalexperience with the Spine Assist. Int J Med Robot. 2006;2: 114-122.
    • (2006) Int J Med Robot , vol.2 , pp. 114-122
    • Sukovich, W.1    Brink-Danan, S.2    Hardenbrook, M.3
  • 15
    • 34447526747 scopus 로고    scopus 로고
    • Computed tomography-guidedpercutaneous facet screw fixation in the lumbar spine. Technical note
    • Kang HY, Lee SH, Jeon SH, Shin SW. Computed tomography-guidedpercutaneous facet screw fixation in the lumbar spine. Technical note.J Neurosurg Spine. 2007;7: 95-98.
    • (2007) J Neurosurg Spine , vol.7 , pp. 95-98
    • Kang, H.Y.1    Lee, S.H.2    Jeon, S.H.3    Shin, S.W.4
  • 17
    • 0020631339 scopus 로고
    • Ruptured lumbar arterypseudoaneyrysm: An unusual cause of retroperitoneal haemorrhage
    • Stewart JR, Barth KH, Williams GM. Ruptured lumbar arterypseudoaneyrysm: an unusual cause of retroperitoneal haemorrhage.Surgery. 1983;94: 592-594.
    • (1983) Surgery , vol.94 , pp. 592-594
    • Stewart, J.R.1    Barth, K.H.2    Williams, G.M.3
  • 18
    • 0037291592 scopus 로고    scopus 로고
    • Arterial complications following anterior lumbar interbody fusion: Reportof eight cases
    • Kulkarni SS, Lowery GL, Ross RE, Ravi Sankar K, Lykomitros V.Arterial complications following anterior lumbar interbody fusion: reportof eight cases. Eur Spine J. 2003;12: 48-54.
    • (2003) Eur Spine J , vol.12 , pp. 48-54
    • Kulkarni, S.S.1    Lowery, G.L.2    Ross, R.E.3    Ravi Sankar, K.4    Lykomitros, V.5
  • 19
    • 0029160923 scopus 로고
    • Thesurgical and medical perioperative complications of anterior spinalfusion surgery in the thoracic and lumbar spine in adults. A review of1223 procedures
    • Faciszewski T, Winter RB, Lonstein JE, Denis F, Johnson L. Thesurgical and medical perioperative complications of anterior spinalfusion surgery in the thoracic and lumbar spine in adults. A review of1223 procedures. Spine. 1995;20: 1592-1599.
    • (1995) Spine , vol.20 , pp. 1592-1599
    • Faciszewski, T.1    Winter, R.B.2    Lonstein, J.E.3    Denis, F.4    Johnson, L.5
  • 20
    • 39049095754 scopus 로고    scopus 로고
    • Strategies for prevention andoperative treatment of aortic lesions related to spinal interventions
    • Kopp R, Beisse R, Weidenhagen R, et al. Strategies for prevention andoperative treatment of aortic lesions related to spinal interventions.Spine. 2007;32: 753-760.
    • (2007) Spine , vol.32 , pp. 753-760
    • Kopp, R.1    Beisse, R.2    Weidenhagen, R.3
  • 21
    • 34548854531 scopus 로고    scopus 로고
    • Pseudoaneurysm of thesuperior gluteal artery during iliosacral screw fixation
    • Maled I, Velez R, Lopez R, Batalla L, Caja VL. Pseudoaneurysm of thesuperior gluteal artery during iliosacral screw fixation. Acta OrthopBelg. 2007;73: 544-547.
    • (2007) Acta OrthopBelg , vol.73 , pp. 544-547
    • Maled, I.1    Velez, R.2    Lopez, R.3    Batalla, L.4    Caja, V.L.5
  • 23
    • 1642505540 scopus 로고    scopus 로고
    • Endovascular treatment of aniatrogenic thoracic aortic injury after spinal instrumentation: Case report
    • Minor ME, Morrissey NJ, Peress R, et al. Endovascular treatment of aniatrogenic thoracic aortic injury after spinal instrumentation: case report.J Vasc Surg. 2004;39: 893-896.
    • (2004) J Vasc Surg , vol.39 , pp. 893-896
    • Minor, M.E.1    Morrissey, N.J.2    Peress, R.3
  • 24
    • 0028314202 scopus 로고
    • Thromboticocclusion of the left common iliac artery after an anterior retroperitonealapproach to the lumbar spine
    • Marsicano J, Mirovsky Y, Remer S, Bloom N, Neuwirth M. Thromboticocclusion of the left common iliac artery after an anterior retroperitonealapproach to the lumbar spine. Spine. 1994;19: 357-359.
    • (1994) Spine , vol.19 , pp. 357-359
    • Marsicano, J.1    Mirovsky, Y.2    Remer, S.3    Bloom, N.4    Neuwirth, M.5
  • 26
    • 27644543217 scopus 로고    scopus 로고
    • Thoracic vertebral screwimpingement on the aorta in an in vivo bovine model
    • Faro FD, Farnsworth CL, Shapiro GS, et al. Thoracic vertebral screwimpingement on the aorta in an in vivo bovine model. Spine. 2005;30: 2406-2413.
    • (2005) Spine , vol.30 , pp. 2406-2413
    • Faro, F.D.1    Farnsworth, C.L.2    Shapiro, G.S.3
  • 27
    • 70449711692 scopus 로고    scopus 로고
    • Delayediatrogenicinjury of the thoracic aorta by an anterior spinal instrumentation
    • Lavigne F, Mascard E, Laurian C, Dubousset J, Wicart P. Delayediatrogenicinjury of the thoracic aorta by an anterior spinal instrumentation.Eur Spine J. 2009;18: 265-268.
    • (2009) Eur Spine J , vol.18 , pp. 265-268
    • Lavigne, F.1    Mascard, E.2    Laurian, C.3    Dubousset, J.4    Wicart, P.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.