Volumn 28, Issue 9, 2010, Pages 1374-1382

Three-dimensional T1, T2 and proton density mapping with inversion recovery balanced SSFP

Author keywords

BSSFP; Inversion recovery; Relaxometry; TrueFISP

Indexed keywords

ANALYTICAL ERROR; ARTICLE; CONTROLLED STUDY; GRAY MATTER; IMAGE ANALYSIS; IMAGE PROCESSING; IMAGING SYSTEM; NEUROIMAGING; NUCLEAR MAGNETIC RESONANCE IMAGING; PHANTOM; PRIORITY JOURNAL; QUANTITATIVE ANALYSIS; RADIOFREQUENCY; SENSITIVITY AND SPECIFICITY; SIGNAL NOISE RATIO; STEADY STATE FREE PRECESSION; WHITE MATTER;

EID: 77958184867     PISSN: 0730725X     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.mri.2010.06.004     Document Type: Article
Times cited : (14)

References (19)
  • 3
    • 0037382249 scopus 로고    scopus 로고
    • On the transient phase of balanced SSFP sequences
    • Scheffler K. On the transient phase of balanced SSFP sequences. Magn Reson Med 2003, 49(4):781-783.
    • (2003) Magn Reson Med , vol.49 , Issue.4 , pp. 781-783
    • Scheffler, K.1
  • 4
    • 0035095928 scopus 로고    scopus 로고
    • T(1) quantification with inversion recovery TrueFISP
    • Scheffler K., Hennig J. T(1) quantification with inversion recovery TrueFISP. Magn Reson Med 2001, 45(4):720-723.
    • (2001) Magn Reson Med , vol.45 , Issue.4 , pp. 720-723
    • Scheffler, K.1    Hennig, J.2
  • 6
    • 9244237599 scopus 로고    scopus 로고
    • Towards a single-sequence neurologic magnetic resonance imaging examination: multiple-contrast images from an IR TrueFISP experiment
    • Gulani V., Schmitt P., Griswold M.A., Webb A.G., Jakob P.M. Towards a single-sequence neurologic magnetic resonance imaging examination: multiple-contrast images from an IR TrueFISP experiment. Invest Radiol 2004, 39(12):767-774.
    • (2004) Invest Radiol , vol.39 , Issue.12 , pp. 767-774
    • Gulani, V.1    Schmitt, P.2    Griswold, M.A.3    Webb, A.G.4    Jakob, P.M.5
  • 7
    • 77958193922 scopus 로고    scopus 로고
    • Simultaneous T1, T2, and spin density quantification in 5 seconds using inversion recovery SSFP
    • Stehning C., Winkelmann W., Dahnke H. Simultaneous T1, T2, and spin density quantification in 5 seconds using inversion recovery SSFP. Proc Intl Soc Magn Reson Med 2007, 15:1719.
    • (2007) Proc Intl Soc Magn Reson Med , vol.15 , pp. 1719
    • Stehning, C.1    Winkelmann, W.2    Dahnke, H.3
  • 8
    • 77958198281 scopus 로고    scopus 로고
    • Volumetric simultaneous T1, T2, T2* and proton density mapping in one minute using interleaved inversion recovery SSFP and multi gradient echo mapping
    • Stehning C., Winkelmann W., Senegas J., Dahnke H. Volumetric simultaneous T1, T2, T2* and proton density mapping in one minute using interleaved inversion recovery SSFP and multi gradient echo mapping. Proc Intl Soc Magn Reson Med 2008, 16:241.
    • (2008) Proc Intl Soc Magn Reson Med , vol.16 , pp. 241
    • Stehning, C.1    Winkelmann, W.2    Senegas, J.3    Dahnke, H.4
  • 9
    • 69449102528 scopus 로고    scopus 로고
    • Modulated repetition time Look-Locker (MORTLL): a method for rapid high resolution three-dimensional T1 mapping
    • Gai N.D., Butman J.A. Modulated repetition time Look-Locker (MORTLL): a method for rapid high resolution three-dimensional T1 mapping. J Magn Reson Imaging 2009, 30:640-648.
    • (2009) J Magn Reson Imaging , vol.30 , pp. 640-648
    • Gai, N.D.1    Butman, J.A.2
  • 10
    • 0042494544 scopus 로고    scopus 로고
    • Simplified model and stabilization of SSFP sequences
    • Le Roux P. Simplified model and stabilization of SSFP sequences. J Magn Reson 2003, 163(1):23-37.
    • (2003) J Magn Reson , vol.163 , Issue.1 , pp. 23-37
    • Le Roux, P.1
  • 11
    • 0000615669 scopus 로고
    • Function minimization by conjugate gradients
    • Fletcher R., Reeves C.M. Function minimization by conjugate gradients. Comput J 1964, 7:149-154.
    • (1964) Comput J , vol.7 , pp. 149-154
    • Fletcher, R.1    Reeves, C.M.2
  • 14
    • 0242385495 scopus 로고    scopus 로고
    • Flow effects in balanced steady state free precession imaging
    • Markl M., Alley M.T., Elkins C.J., Pelc N.J. Flow effects in balanced steady state free precession imaging. Magn Reson Med 2003, 50(5):892-903.
    • (2003) Magn Reson Med , vol.50 , Issue.5 , pp. 892-903
    • Markl, M.1    Alley, M.T.2    Elkins, C.J.3    Pelc, N.J.4
  • 15
    • 42549161505 scopus 로고    scopus 로고
    • Off-resonance-dependent slice profile effects in balanced steady-state free precession imaging
    • Staehle F., Leupold J., Hennig J., Markl M. Off-resonance-dependent slice profile effects in balanced steady-state free precession imaging. Magn Reson Med 2008, 59:1197-1202.
    • (2008) Magn Reson Med , vol.59 , pp. 1197-1202
    • Staehle, F.1    Leupold, J.2    Hennig, J.3    Markl, M.4
  • 16
    • 0036845522 scopus 로고    scopus 로고
    • Single-breathhold 3D-trueFISP cine cardiac imaging
    • Jung B.A., Hennig J., Scheffler K. Single-breathhold 3D-trueFISP cine cardiac imaging. Magn Reson Med 2002, 48(5):921-925.
    • (2002) Magn Reson Med , vol.48 , Issue.5 , pp. 921-925
    • Jung, B.A.1    Hennig, J.2    Scheffler, K.3
  • 17
    • 0347003637 scopus 로고    scopus 로고
    • Flow artifacts in steady-state free precession cine imaging
    • Storey P., Li W., Chen Q., Edelman R.R. Flow artifacts in steady-state free precession cine imaging. Magn Reson Med 2004, 51(1):115-122.
    • (2004) Magn Reson Med , vol.51 , Issue.1 , pp. 115-122
    • Storey, P.1    Li, W.2    Chen, Q.3    Edelman, R.R.4
  • 18
    • 33750633047 scopus 로고    scopus 로고
    • On the origin of apparent low tissue signals in balanced SSFP
    • Bieri O., Scheffler K. On the origin of apparent low tissue signals in balanced SSFP. Magn Reson Med 2006, 56:1067-1074.
    • (2006) Magn Reson Med , vol.56 , pp. 1067-1074
    • Bieri, O.1    Scheffler, K.2
  • 19
    • 0029664366 scopus 로고    scopus 로고
    • Imaging of the active B1 field in vivo
    • Stollberger R., Wach P. Imaging of the active B1 field in vivo. Magn Reson Med 1996, 35:246-251.
    • (1996) Magn Reson Med , vol.35 , pp. 246-251
    • Stollberger, R.1    Wach, P.2