메뉴 건너뛰기




Volumn 48, Issue 10, 2010, Pages 1381-1387

Laboratory diagnostics in acute poisoning: Critical overview

Author keywords

chromatography; immunoassay; mass spectrometry; poisoning

Indexed keywords

ALCOHOL; AMANITIN; AMPHETAMINE DERIVATIVE; ARSENIC; BARBITURIC ACID DERIVATIVE; BENZODIAZEPINE DERIVATIVE; CANNABINOID DERIVATIVE; COLCHICINE; CYANIDE; DIGOXIN; ETHYLENE GLYCOL; HYDROXYBUTYRIC ACID; IRON; LITHIUM; LYSERGIDE; MERCURY; METAL DERIVATIVE; METHADONE; METHANOL; OPIATE DERIVATIVE; PARACETAMOL; PHENCYCLIDINE; POISON; THALLIUM;

EID: 77958160926     PISSN: 14346621     EISSN: 14374331     Source Type: Journal    
DOI: 10.1515/CCLM.2010.295     Document Type: Review
Times cited : (16)

References (31)
  • 1
    • 7944228547 scopus 로고    scopus 로고
    • Chemistry, pharmacology, toxicology, and hepatic metabolism of designer drugs of the amphetamine (ecstasy), piperazine, and pyrrolidinophenone types: A synopsis
    • Maurer HH, Kraemer T, Springer D, Staack RF. Chemistry, pharmacology, toxicology, and hepatic metabolism of designer drugs of the amphetamine (ecstasy), piperazine, and pyrrolidinophenone types: a synopsis. Ther Drug Monit 2004;26:127-31.
    • (2004) Ther. Drug Monit. , vol.26 , pp. 127-131
    • Maurer, H.H.1    Kraemer, T.2    Springer, D.3    Staack, R.F.4
  • 2
    • 0026733756 scopus 로고
    • Systematic toxicological analysis of drugs and their metabolites by gas chromatography-mass spectrometry
    • Maurer HH. Systematic toxicological analysis of drugs and their metabolites by gas chromatography-mass spectrometry. J Chromatogr 1992;580:3-41.
    • (1992) J. Chromatogr. , vol.580 , pp. 3-41
    • Maurer, H.H.1
  • 3
    • 33748316481 scopus 로고    scopus 로고
    • Screening of drugs and toxic compounds with liquid chromatography-linear ion trap tandem mass spectrometry
    • Sauvage FL, Sain-Marcoux F, Duretz B, Deporte D, Lachatre G, Marquet P. Screening of drugs and toxic compounds with liquid chromatography-linear ion trap tandem mass spectrometry. Clin Chem 2006;52:1735-42.
    • (2006) Clin. Chem. , vol.52 , pp. 1735-1742
    • Sauvage, F.L.1    Sain-Marcoux, F.2    Duretz, B.3    Deporte, D.4    Lachatre, G.5    Marquet, P.6
  • 4
    • 68049135677 scopus 로고    scopus 로고
    • Development of a broad toxicological screening technique for urine using ultra-performance liquid chromatography and time-offlight mass spectrometry
    • Lee HK, Ho CS, Io YP, Lai PS, Shek CC, Lo AC, et al. Development of a broad toxicological screening technique for urine using ultra-performance liquid chromatography and time-offlight mass spectrometry. Anal Chim Acta 2009;649:80-90.
    • (2009) Anal. Chim. Acta , vol.649 , pp. 80-90
    • Lee, H.K.1    Ho, C.S.2    Io, Y.P.3    Lai, P.S.4    Shek, C.C.5    Lo, A.C.6
  • 5
    • 73249117667 scopus 로고    scopus 로고
    • Rapid screening and confirmation of drugs and toxic compounds in biological specimens using liquid chromatography/ion trap tandem mass spectrometry and automated library search
    • Liu HC, Liu RH, Lin DL, Ho HO. Rapid screening and confirmation of drugs and toxic compounds in biological specimens using liquid chromatography/ion trap tandem mass spectrometry and automated library search. Rapid Commun Mass Spectrom 2010;24:75-84.
    • (2010) Rapid Commun. Mass Spectrom. , vol.24 , pp. 75-84
    • Liu, H.C.1    Liu, R.H.2    Lin, D.L.3    Ho, H.O.4
  • 6
    • 77951258597 scopus 로고    scopus 로고
    • Detection and identification of 700 drugs by multi-target screening with a 3200 Q TRAP LC-MS/MS system and library searching
    • Dresen S, Ferreiros N, Gnann H, Zimmermann R, Weinmann W. Detection and identification of 700 drugs by multi-target screening with a 3200 Q TRAP LC-MS/MS system and library searching. Anal Bioanal Chem 2010;396:2425-34.
    • (2010) Anal. Bioanal Chem. , vol.396 , pp. 2425-2434
    • Dresen, S.1    Ferreiros, N.2    Gnann, H.3    Zimmermann, R.4    Weinmann, W.5
  • 7
    • 0002521898 scopus 로고
    • Urine colour test for the detection of phenothiazine compounds
    • Forrest IS, Forrest FM. Urine colour test for the detection of phenothiazine compounds. Clin Chem 1960;6:11-5.
    • (1960) Clin. Chem. , vol.6 , pp. 11-15
    • Forrest, I.S.1    Forrest, F.M.2
  • 8
    • 34547380878 scopus 로고    scopus 로고
    • Bioanalytical procedures for determination of drugs of abuse in blood
    • Kraemer T, Paul LD. Bioanalytical procedures for determination of drugs of abuse in blood. Anal Bioanal Chem 2007;388:1415-35.
    • (2007) Anal. Bioanal Chem. , vol.388 , pp. 1415-1435
    • Kraemer, T.1    Paul, L.D.2
  • 9
    • 0018069442 scopus 로고
    • Acetaminophen overdose: Incidence, diagnosis, and management in 416 patients
    • Rumack BH, Peterson RG. Acetaminophen overdose: incidence, diagnosis, and management in 416 patients. Pediatrics 1978;62:898-903.
    • (1978) Pediatrics , vol.62 , pp. 898-903
    • Rumack, B.H.1    Peterson, R.G.2
  • 10
    • 0018383771 scopus 로고
    • Acetaminophen kinetics in acutely poisoned patients
    • Slattery JT, Levy G. Acetaminophen kinetics in acutely poisoned patients. Clin Pharm Ther 1979;25:185-95.
    • (1979) Clin. Pharm. Ther. , vol.25 , pp. 185-195
    • Slattery, J.T.1    Levy, G.2
  • 13
    • 0036306328 scopus 로고    scopus 로고
    • Endogenous and exogenous digoxin-like immunoreactive substances: Impact on therapeutic drug monitoring of digoxin
    • Dasgupta A. Endogenous and exogenous digoxin-like immunoreactive substances: impact on therapeutic drug monitoring of digoxin. Am J Clin Pathol 2002;118:132-40.
    • (2002) Am. J. Clin. Pathol. , vol.118 , pp. 132-140
    • Dasgupta, A.1
  • 14
    • 0034306511 scopus 로고    scopus 로고
    • Validated electrospray liquid chromatographic-mass spectrometric assay for the determination of the mushroom toxins alpha-and beta-amanitin in urine after immunoaffinity extraction
    • Maurer HH, Schmitt CJ, Weber AA, Kraemer T. Validated electrospray liquid chromatographic-mass spectrometric assay for the determination of the mushroom toxins alpha-and beta-amanitin in urine after immunoaffinity extraction. J Chromatogr B Biomed Sci Appl 2000;748:125-35.
    • (2000) J. Chromatogr. B. Biomed. Sci. Appl. , vol.748 , pp. 125-135
    • Maurer, H.H.1    Schmitt, C.J.2    Weber, A.A.3    Kraemer, T.4
  • 16
    • 0030904814 scopus 로고    scopus 로고
    • Recommendations for the reliable detection of illicit drugs in urine, with special attention to the workplace, in the European Union (December 1996). The Toxicology Experts' Working Group
    • Killander J, de la Torre R, Segura J, de Zeeuw R, Williams J. Recommendations for the reliable detection of illicit drugs in urine, with special attention to the workplace, in the European Union (December 1996). The Toxicology Experts' Working Group. Scand J Clin Lab Invest 1997;57:97-103.
    • (1997) Scand. J. Clin. Lab. Invest. , vol.57 , pp. 97-103
    • Killander, J.1    De La Torre, R.2    Segura, J.3    De Zeeuw, R.4    Williams, J.5
  • 17
    • 0141794322 scopus 로고    scopus 로고
    • Performance characteristics of selected immunoassays for preliminary test of 3, 4-methylenedioxymethamphetamine, methamphetamine, and related drugs in urine specimens
    • Hsu J, Liu C, Liu CP, Tsay WI, Li JH, Lin DL, et al. Performance characteristics of selected immunoassays for preliminary test of 3, 4-methylenedioxymethamphetamine, methamphetamine, and related drugs in urine specimens. J Anal Toxicol 2003;27:471-8.
    • (2003) J. Anal. Toxicol. , vol.27 , pp. 471-478
    • Hsu, J.1    Liu, C.2    Liu, C.P.3    Tsay, W.I.4    Li, J.H.5    Lin, D.L.6
  • 18
    • 33745893810 scopus 로고    scopus 로고
    • Reliability of the cloned-enzyme donor immunoassay (CEDIA) for cocaine in human serum in the range between the detection limit and the cut-off
    • Schutz H, Auch J, Erdmann F, Weiler G, Verhoff MA. Reliability of the cloned-enzyme donor immunoassay (CEDIA) for cocaine in human serum in the range between the detection limit and the cut-off. Arzneimittelforschung 2006;56:414-20.
    • (2006) Arzneimittelforschung , vol.56 , pp. 414-420
    • Schutz, H.1    Auch, J.2    Erdmann, F.3    Weiler, G.4    Verhoff, M.A.5
  • 21
    • 14844312890 scopus 로고    scopus 로고
    • LC-MS/MS systematic toxicological analysis: Comparison of MS/MS spectra obtained with different instruments and settings
    • Jansen R, Lachatre G, Marquet P. LC-MS/MS systematic toxicological analysis: comparison of MS/MS spectra obtained with different instruments and settings. Clin Biochem 2005;38:362-72.
    • (2005) Clin. Biochem. , vol.38 , pp. 362-372
    • Jansen, R.1    Lachatre, G.2    Marquet, P.3
  • 22
    • 33645510278 scopus 로고    scopus 로고
    • Isotopic pattern and accurate mass determination in urine drug screening by liquid chromatography/time-of-flight mass spectrometry
    • Ojanpera S, Pelander A, Pelzing M, Krebs I, Vuori E, Ojanpera I. Isotopic pattern and accurate mass determination in urine drug screening by liquid chromatography/time-of-flight mass spectrometry. Rapid Commun Mass Spectrom 2006;20:1161-7.
    • (2006) Rapid Commun. Mass Spectrom. , vol.20 , pp. 1161-1167
    • Ojanpera, S.1    Pelander, A.2    Pelzing, M.3    Krebs, I.4    Vuori, E.5    Ojanpera, I.6
  • 24
    • 71449093416 scopus 로고    scopus 로고
    • ESI-MS/MS library of 1253 compounds for application in forensic and clinical toxicology
    • Dresen S, Gergov M, Politi L, Halter C, Weinmann W. ESI-MS/MS library of 1253 compounds for application in forensic and clinical toxicology. Anal Bioanal Chem 2009;395:2521-6.
    • (2009) Anal. Bioanal Chem. , vol.395 , pp. 2521-2526
    • Dresen, S.1    Gergov, M.2    Politi, L.3    Halter, C.4    Weinmann, W.5
  • 27
    • 0037097026 scopus 로고    scopus 로고
    • Screening, library-assisted identification and validated quantification of oral antidiabetics of the sulfonylurea-type in plasma by atmospheric pressure chemical ionization liquid chromatography-mass spectrometry
    • Maurer HH, Kratzsch C, Kraemer T, Peters FT, Weber AA. Screening, library-assisted identification and validated quantification of oral antidiabetics of the sulfonylurea-type in plasma by atmospheric pressure chemical ionization liquid chromatography-mass spectrometry. J Chromatogr B Analyt Technol Biomed Life Sci 2002;773:63-73.
    • (2002) J. Chromatogr. B. Analyt Technol. Biomed. Life Sci. , vol.773 , pp. 63-73
    • Maurer, H.H.1    Kratzsch, C.2    Kraemer, T.3    Peters, F.T.4    Weber, A.A.5
  • 28
    • 51349162644 scopus 로고    scopus 로고
    • Pitfalls and prevention strategies for liquid chromatography-tandem mass spectrometry in the selected reaction-monitoring mode for drug analysis
    • Sauvage FL, Gaulier JM, Lachatre G, Marquet P. Pitfalls and prevention strategies for liquid chromatography-tandem mass spectrometry in the selected reaction-monitoring mode for drug analysis. Clin Chem 2008;54:1519-27.
    • (2008) Clin. Chem. , vol.54 , pp. 1519-1527
    • Sauvage, F.L.1    Gaulier, J.M.2    Lachatre, G.3    Marquet, P.4
  • 29
    • 0037350735 scopus 로고    scopus 로고
    • Screening, library-assisted identification and validated quantification of fifteen neuroleptics and three of their metabolites in plasma by liquid chromatography/mass spectrometry with atmospheric pressure chemical ionization
    • Kratzsch C, Weber AA, Peter FT, Kraemer T, Maurer HH. Screening, library-assisted identification and validated quantification of fifteen neuroleptics and three of their metabolites in plasma by liquid chromatography/mass spectrometry with atmospheric pressure chemical ionization. J Mass Spectrom 2003;38:283-95.
    • (2003) J. Mass Spectrom. , vol.38 , pp. 283-295
    • Kratzsch, C.1    Weber, A.A.2    Peter, F.T.3    Kraemer, T.4    Maurer, H.H.5
  • 30
    • 0030770985 scopus 로고    scopus 로고
    • A sudden awakening from a near coma after combined intake of gamma-hydroxybutyric acid (GHB) and ethanol
    • Louagie HK, Verstraete AG, De Soete CJ, Baetens D, Calle PA. A sudden awakening from a near coma after combined intake of gamma-hydroxybutyric acid (GHB) and ethanol. Clin Toxicol 1997;35:591-4.
    • (1997) Clin. Toxicol. , vol.35 , pp. 591-594
    • Louagie, H.K.1    Verstraete, A.G.2    De Soete, C.J.3    Baetens, D.4    Calle, P.A.5
  • 31
    • 0032737376 scopus 로고    scopus 로고
    • A simple, rapid and sensitive semimicro method for the measurement of cyanide in blood
    • Vesey CJ, McAllister H, Langford RM. A simple, rapid and sensitive semimicro method for the measurement of cyanide in blood. Ann Clin Biochem 1999;36:755-8.
    • (1999) Ann. Clin. Biochem. , vol.36 , pp. 755-758
    • Vesey, C.J.1    McAllister, H.2    Langford, R.M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.