-
1
-
-
0034011532
-
The utility of transbronchial needle aspiration in the staging of bronchogenic carcinoma
-
1:STN:280:DC%2BD3c7otVaktw%3D%3D 10673206
-
EM Harrow W Abi-Saleh J Blum T Harkin S Gasparini DJ Addrizzo-Harris AC Arroliga G Wight AC Mehta 2000 The utility of transbronchial needle aspiration in the staging of bronchogenic carcinoma Am J Respir Crit Care Med 161 601 607 1:STN:280:DC%2BD3c7otVaktw%3D%3D 10673206
-
(2000)
Am J Respir Crit Care Med
, vol.161
, pp. 601-607
-
-
Harrow, E.M.1
Abi-Saleh, W.2
Blum, J.3
Harkin, T.4
Gasparini, S.5
Addrizzo-Harris, D.J.6
Arroliga, A.C.7
Wight, G.8
Mehta, A.C.9
-
2
-
-
0346363594
-
Yield of Transbronchial Needle Aspiration in Diagnosis of Mediastinal Lesions
-
DOI 10.1378/chest.124.6.2131
-
A Sharafkhaneh W Baaklini AB Gorin L Green 2003 Yield of transbronchial needle aspiration in diagnosis of mediastinal lesions Chest 124 2131 2135 10.1378/chest.124.6.2131 14665491 (Pubitemid 38010580)
-
(2003)
Chest
, vol.124
, Issue.6
, pp. 2131-2135
-
-
Sharafkhaneh, A.1
Baaklini, W.2
Gorin, A.B.3
Green, L.4
-
3
-
-
33947359470
-
Conventional transbronchial needle aspiration decreases the rate of surgical sampling of intrathoracic lymphadenopathy
-
DOI 10.1378/chest.06-1377
-
NM Patel A Pohlman A Husain I Noth JB Hall JP Kress 2007 Conventional transbronchial needle aspiration decreases the rate if surgical sampling of intrathoracic lymphadenopathy Chest 131 773 778 10.1378/chest.06-1377 17356092 (Pubitemid 46446869)
-
(2007)
Chest
, vol.131
, Issue.3
, pp. 773-778
-
-
Patel, N.M.1
Pohlman, A.2
Husain, A.3
Noth, I.4
Hall, J.B.5
Kress, J.P.6
-
4
-
-
0020563197
-
Comparison of transbronchial fine-needle aspiration biopsy, aspiration of bronchial secretion, bronchial washing, brush biopsy, and forceps biopsy in the diagnosis of lung cancer
-
R Lundgreen F Bligman T Angstrom 1983 Comparison of transbronchial fine-needle aspiration biopsy, aspiration of bronchial secretion, bronchial washing, brush biopsy, and forceps biopsy in the diagnosis of lung cancer Eur J Respir Dis 64 378 385
-
(1983)
Eur J Respir Dis
, vol.64
, pp. 378-385
-
-
Lundgreen, R.1
Bligman, F.2
Angstrom, T.3
-
5
-
-
0017158726
-
Diagnostic accuracy in lung cancer: Comparison of techniques used in association with flexible fiberoptic bronchoscopy
-
1:STN:280:DyaE283gvFGnsg%3D%3D 10.1378/chest.69.6.752 1277894
-
PA Kvale FR Bode S Kini 1976 Diagnostic accuracy in lung cancer: comparison of techniques used in association with flexible fiberoptic bronchoscopy Chest 69 752 757 1:STN:280:DyaE283gvFGnsg%3D%3D 10.1378/chest.69.6.752 1277894
-
(1976)
Chest
, vol.69
, pp. 752-757
-
-
Kvale, P.A.1
Bode, F.R.2
Kini, S.3
-
6
-
-
0021870838
-
Transbronchial needle aspiration in the diagnosis of submucosal and peribronchial bronchogenic carcinoma
-
D Shure PF Fedullo 1985 Transbronchial needle aspiration in the diagnosis of submucosal and peribronchial bronchogenic carcinoma Chest 88 49 51 1:STN:280:DyaL2M3ivFKktw%3D%3D 10.1378/chest.88.1.49 2988863 (Pubitemid 15073574)
-
(1985)
Chest
, vol.88
, Issue.1
, pp. 49-51
-
-
Shure, D.1
Fedullo, P.F.2
-
7
-
-
0030812094
-
Underutilization of transbronchial needle aspiration: Experiences of current pulmonary fellows
-
10.1378/chest.112.1.251
-
EF Haponik D Shure 1997 Underutilization of transbronchial needle aspiration: experiences of current pulmonary fellows Chest 113 251 253 10.1378/chest.112.1.251
-
(1997)
Chest
, vol.113
, pp. 251-253
-
-
Haponik, E.F.1
Shure, D.2
-
8
-
-
0033929302
-
Bronchoscopy in North America: Survey by the American Association for Bronchology
-
10.1097/00128594-200007010-00004
-
HG Colt UBS Prakash KP Offord 1999 Bronchoscopy in North America: survey by the American Association for Bronchology J Bronchol 7 8 25 10.1097/00128594-200007010-00004
-
(1999)
J Bronchol
, vol.7
, pp. 8-25
-
-
Colt, H.G.1
Prakash, U.B.S.2
Offord, K.P.3
-
10
-
-
0035119119
-
CT fluoroscopy guidance for transbronchial needle aspiration: An experience in 35 patients
-
DOI 10.1378/chest.119.2.329
-
E Garpestad S Goldberg F Herth R Garland J LoCicero III R Thurer A Ernst 2001 CT fluoroscopy guidance for transbronchial needle aspiration: an experience in 35 patients Chest 119 329 332 1:STN:280:DC%2BD3M7psVKgtQ%3D%3D 10.1378/chest.119.2.329 11171705 (Pubitemid 32163739)
-
(2001)
Chest
, vol.119
, Issue.2
, pp. 329-332
-
-
Garpestad, E.1
Goldberg, S.N.2
Herth, F.3
Garland, R.4
LoCicero III, J.5
Thurer, R.6
Ernst, A.7
-
11
-
-
1642575308
-
Conventional vs Endobronchial Ultrasound-Guided Transbronchial Needle Aspiration: A Randomized Trial
-
DOI 10.1378/chest.125.1.322
-
F Herth HD Becker A Ernst 2004 Conventional versus endobronchial ultrasound-guided transbronchial needle aspiration: a randomised trial Chest 125 322 325 10.1378/chest.125.1.322 14718460 (Pubitemid 38114601)
-
(2004)
Chest
, vol.125
, Issue.1
, pp. 322-325
-
-
Herth, F.1
Becker, H.D.2
Ernst, A.3
-
12
-
-
14744298715
-
Endobronchial and endoscopic ultrasound-guided real-time fine-needle aspiration for mediastinal staging
-
10.1183/09031936.05.00095404
-
RC Rintoul KM Skwarski JT Murchison WA Wallace WS Walker ID Penman 2006 Endobronchial and endoscopic ultrasound-guided real-time fine-needle aspiration for mediastinal staging Eur Respir J 25 416 421 10.1183/09031936.05.00095404
-
(2006)
Eur Respir J
, vol.25
, pp. 416-421
-
-
Rintoul, R.C.1
Skwarski, K.M.2
Murchison, J.T.3
Wallace, W.A.4
Walker, W.S.5
Penman, I.D.6
-
14
-
-
0030926263
-
Regional lymph node classification for lung cancer staging
-
1:STN:280:DyaK2szjtVOnsg%3D%3D 10.1378/chest.111.6.1718 9187199
-
CF Mountain CM Dresler 1997 Regional lymph node classification for lung cancer staging Chest 111 1718 1723 1:STN:280:DyaK2szjtVOnsg%3D%3D 10.1378/chest.111.6.1718 9187199
-
(1997)
Chest
, vol.111
, pp. 1718-1723
-
-
Mountain, C.F.1
Dresler, C.M.2
-
15
-
-
0036180283
-
ERS/ATS statement on interventional pulmonology
-
DOI 10.1183/09031936.02.00204602
-
CT Bolliger PN Mathur 2002 ERS/ATS statement on interventional pulmonology Eur Respir J 19 356 373 1:STN:280:DC%2BD387jtVOqsA%3D%3D 10.1183/09031936.02.00204602 11866017 (Pubitemid 34162840)
-
(2002)
European Respiratory Journal
, vol.19
, Issue.2
, pp. 356-373
-
-
Bolliger, C.T.1
Mathur, P.N.2
-
16
-
-
0032754230
-
The current role of mediastinoscopy in the evaluation of thoracic disease
-
DOI 10.1016/S0022-5223(99)70059-0
-
ZT Hammoud RC Anderson BF Meyers TJ Guthrie CL Roper JD Cooper GA Patterson 1999 The current role of mediastinoscopy in the evaluation of thoracic disease J Thorax Cardiovasc Surg 118 894 899 1:STN:280:DC%2BD3c%2Fgs1Smtw%3D%3D 10.1016/S0022-5223(99)70059-0 (Pubitemid 29511073)
-
(1999)
Journal of Thoracic and Cardiovascular Surgery
, vol.118
, Issue.5
, pp. 894-899
-
-
Hammoud, Z.T.1
Anderson, R.C.2
Meyers, B.E.3
Guthrie, T.J.4
Roper, C.L.5
Cooper, J.D.6
Patterson, G.A.7
Wood, D.E.8
Daly, B.D.T.9
Mentzer, S.J.10
Todd, T.R.J.11
-
17
-
-
0002009697
-
Transbronchial needle aspiration
-
J.F. Beamis P.N. Mathur (eds). McGraw-Hill New York
-
Mehta AC, Dasgupta A, Wang KP (1999) Transbronchial needle aspiration. In: Beamis JF, Mathur PN (eds) Interventional pulmonology. McGraw-Hill, New York, pp 241-254
-
(1999)
Interventional Pulmonology
, pp. 241-254
-
-
Mehta, A.C.1
Dasgupta, A.2
Wang, K.P.3
-
18
-
-
25444440096
-
Accuracy of transbronchial needle aspiration for mediastinal staging of non-small cell lung cancer: A meta-analysis
-
DOI 10.1136/thx.2005.041525
-
JE Holty WG Kuschner MK Gould 2005 Accuracy of transbronchial needle aspiration for mediastinal staging of non-small cell lung cancer: a meta-analysis Thorax 60 949 955 10.1136/thx.2005.041525 15994251 (Pubitemid 41598211)
-
(2005)
Thorax
, vol.60
, Issue.11
, pp. 949-955
-
-
Holty, J.-E.C.1
Kuschner, W.G.2
Gould, M.K.3
-
19
-
-
0036683644
-
Transbronchial needle aspiration in diagnosing and staging lung cancer: How many aspirates are needed?
-
DOI 10.1164/rccm.2106153
-
R Chin TW McCain MA Lucia JO Cappellari NE Adair JF Lovato DP Dunagan MA Brooks HP Clark EF Haponik 2002 Transbronchial needle aspiration in diagnosing and staging lung cancer: how many aspirates are needed? Am J Respir Crit Care Med 166 377 381 10.1164/rccm.2106153 12153974 (Pubitemid 34864430)
-
(2002)
American Journal of Respiratory and Critical Care Medicine
, vol.166
, Issue.3
, pp. 377-381
-
-
Chin Jr., R.1
McCain, T.W.2
Lucia, M.A.3
Cappellari, J.O.4
Adair, N.E.5
Lovato, J.F.6
Dunagan, D.P.7
Brooks, M.A.8
Clark, H.P.9
Haponik, E.F.10
-
20
-
-
0034104259
-
Utility of on-site cytopathology assessment for bronchoscopic evaluation of lung masses and adeopathy
-
1:STN:280:DC%2BD3c3jtFKisw%3D%3D 10.1378/chest.117.4.1186 10767258
-
GB Diette P White P Terry M Jenckes D Rosenthal HR Rubin 2000 Utility of on-site cytopathology assessment for bronchoscopic evaluation of lung masses and adeopathy Chest 117 1186 1190 1:STN:280:DC%2BD3c3jtFKisw%3D%3D 10.1378/chest.117.4.1186 10767258
-
(2000)
Chest
, vol.117
, pp. 1186-1190
-
-
Diette, G.B.1
White, P.2
Terry, P.3
Jenckes, M.4
Rosenthal, D.5
Rubin, H.R.6
-
21
-
-
17844409094
-
Utility of rapid on-site evaluation of transbronchial needle aspirates
-
DOI 10.1159/000084050
-
AH Diacon MM Schuurmans J Theron M Louw CA Wright K Brundyn CT Bolliger 2005 Utility of rapid on-site evaluation of transbronchial needle aspirates Respiration 72 182 188 10.1159/000084050 15824529 (Pubitemid 40591532)
-
(2005)
Respiration
, vol.72
, Issue.2
, pp. 182-188
-
-
Diacon, A.H.1
Schuurmans, M.M.2
Theron, J.3
Louw, M.4
Wright, C.A.5
Brundyn, K.6
Bolliger, C.T.7
-
22
-
-
0027176074
-
Comparison of the Wang 19-gauge and 22-gauge needles in the mediastinal staging of lung cancer
-
1:STN:280:DyaK3s3kvFWqug%3D%3D 8484639
-
DA Schenk SL Chambers S Derdak KH Komadina JS Pickard PJ Strollo RE Lewis AJ Patfield JH Henderson SM Tomski 1993 Comparison of the Wang 19-gauge and 22-gauge needles in the mediastinal staging of lung cancer Am Rev Respir Dis 147 1251 1258 1:STN:280:DyaK3s3kvFWqug%3D%3D 8484639
-
(1993)
Am Rev Respir Dis
, vol.147
, pp. 1251-1258
-
-
Schenk, D.A.1
Chambers, S.L.2
Derdak, S.3
Komadina, K.H.4
Pickard, J.S.5
Strollo, P.J.6
Lewis, R.E.7
Patfield, A.J.8
Henderson, J.H.9
Tomski, S.M.10
-
24
-
-
0029916357
-
Endobronchial ultrasound-guided needle aspiration of mediastinal adenopathy
-
1:STN:280:DyaK287pslaruw%3D%3D 8616576
-
JJ Shannon RO Bude JB Orens FS Becker RI Whyte JM Rubin LE Quint FJ Martinez 1996 Endobronchial ultrasound-guided needle aspiration of mediastinal adenopathy Am J Respir Crit Care Med 153 1424 1430 1:STN:280: DyaK287pslaruw%3D%3D 8616576
-
(1996)
Am J Respir Crit Care Med
, vol.153
, pp. 1424-1430
-
-
Shannon, J.J.1
Bude, R.O.2
Orens, J.B.3
Becker, F.S.4
Whyte, R.I.5
Rubin, J.M.6
Quint, L.E.7
Martinez, F.J.8
-
25
-
-
34250880220
-
Can mediastinal nodal mobility explain the low yield rates for transbronchial needle aspiration without real-time imaging?
-
DOI 10.1378/chest.06-2964
-
AH Piet FJ Lagerwaard PW Kunst JR de Koste BJ Slotman S Senan 2007 Can mediastinal nodal mobility explain the low yield rates for transbronchial needle aspiration without real-time imaging? Chest 131 1783 1787 10.1378/chest.06-2964 17565020 (Pubitemid 46981634)
-
(2007)
Chest
, vol.131
, Issue.6
, pp. 1783-1787
-
-
Piet, A.H.M.1
Lagerwaard, F.J.2
Kunst, P.W.A.3
Van Sornsen De Koste, J.R.4
Slotman, B.J.5
Senan, S.6
-
26
-
-
33846262994
-
Transbronchial needle aspirates: How many passes per target site?
-
DOI 10.1183/09031936.00055506
-
AH Diacon MM Schuurmans J Theron K Brundyn M Louw CA Wright CT Bolliger 2007 Transbronchial needle aspirates: how many passes per target site? Eur Respir J 29 112 116 1:STN:280:DC%2BD2s%2FgtFCksQ%3D%3D 10.1183/09031936.00055506 17005579 (Pubitemid 46092006)
-
(2007)
European Respiratory Journal
, vol.29
, Issue.1
, pp. 112-116
-
-
Diacon, A.H.1
Schuurmans, M.M.2
Theron, J.3
Brundyn, K.4
Louw, M.5
Wright, C.A.6
Bolliger, C.T.7
|