메뉴 건너뛰기




Volumn 24, Issue 9, 2010, Pages 2105-2109

A strategy to improve the yield of transbronchial needle aspiration

Author keywords

EBUS; Lung cancer; Lymph node; Staging; TBNA

Indexed keywords

ARTICLE; CANCER DIAGNOSIS; CLINICAL ARTICLE; CONTROLLED STUDY; DIAGNOSTIC ACCURACY; ENDOBRONCHIAL ULTRASONOGRAPHY; HUMAN; HUMAN TISSUE; LUNG CANCER; MEDIASTINUM LYMPH NODE; PRIORITY JOURNAL; TRANSBRONCHIAL ASPIRATION; TUMOR LOCALIZATION;

EID: 77957941119     PISSN: 09302794     EISSN: 14322218     Source Type: Journal    
DOI: 10.1007/s00464-010-0906-4     Document Type: Article
Times cited : (8)

References (26)
  • 2
    • 0346363594 scopus 로고    scopus 로고
    • Yield of Transbronchial Needle Aspiration in Diagnosis of Mediastinal Lesions
    • DOI 10.1378/chest.124.6.2131
    • A Sharafkhaneh W Baaklini AB Gorin L Green 2003 Yield of transbronchial needle aspiration in diagnosis of mediastinal lesions Chest 124 2131 2135 10.1378/chest.124.6.2131 14665491 (Pubitemid 38010580)
    • (2003) Chest , vol.124 , Issue.6 , pp. 2131-2135
    • Sharafkhaneh, A.1    Baaklini, W.2    Gorin, A.B.3    Green, L.4
  • 3
    • 33947359470 scopus 로고    scopus 로고
    • Conventional transbronchial needle aspiration decreases the rate of surgical sampling of intrathoracic lymphadenopathy
    • DOI 10.1378/chest.06-1377
    • NM Patel A Pohlman A Husain I Noth JB Hall JP Kress 2007 Conventional transbronchial needle aspiration decreases the rate if surgical sampling of intrathoracic lymphadenopathy Chest 131 773 778 10.1378/chest.06-1377 17356092 (Pubitemid 46446869)
    • (2007) Chest , vol.131 , Issue.3 , pp. 773-778
    • Patel, N.M.1    Pohlman, A.2    Husain, A.3    Noth, I.4    Hall, J.B.5    Kress, J.P.6
  • 4
    • 0020563197 scopus 로고
    • Comparison of transbronchial fine-needle aspiration biopsy, aspiration of bronchial secretion, bronchial washing, brush biopsy, and forceps biopsy in the diagnosis of lung cancer
    • R Lundgreen F Bligman T Angstrom 1983 Comparison of transbronchial fine-needle aspiration biopsy, aspiration of bronchial secretion, bronchial washing, brush biopsy, and forceps biopsy in the diagnosis of lung cancer Eur J Respir Dis 64 378 385
    • (1983) Eur J Respir Dis , vol.64 , pp. 378-385
    • Lundgreen, R.1    Bligman, F.2    Angstrom, T.3
  • 5
    • 0017158726 scopus 로고
    • Diagnostic accuracy in lung cancer: Comparison of techniques used in association with flexible fiberoptic bronchoscopy
    • 1:STN:280:DyaE283gvFGnsg%3D%3D 10.1378/chest.69.6.752 1277894
    • PA Kvale FR Bode S Kini 1976 Diagnostic accuracy in lung cancer: comparison of techniques used in association with flexible fiberoptic bronchoscopy Chest 69 752 757 1:STN:280:DyaE283gvFGnsg%3D%3D 10.1378/chest.69.6.752 1277894
    • (1976) Chest , vol.69 , pp. 752-757
    • Kvale, P.A.1    Bode, F.R.2    Kini, S.3
  • 6
    • 0021870838 scopus 로고
    • Transbronchial needle aspiration in the diagnosis of submucosal and peribronchial bronchogenic carcinoma
    • D Shure PF Fedullo 1985 Transbronchial needle aspiration in the diagnosis of submucosal and peribronchial bronchogenic carcinoma Chest 88 49 51 1:STN:280:DyaL2M3ivFKktw%3D%3D 10.1378/chest.88.1.49 2988863 (Pubitemid 15073574)
    • (1985) Chest , vol.88 , Issue.1 , pp. 49-51
    • Shure, D.1    Fedullo, P.F.2
  • 7
    • 0030812094 scopus 로고    scopus 로고
    • Underutilization of transbronchial needle aspiration: Experiences of current pulmonary fellows
    • 10.1378/chest.112.1.251
    • EF Haponik D Shure 1997 Underutilization of transbronchial needle aspiration: experiences of current pulmonary fellows Chest 113 251 253 10.1378/chest.112.1.251
    • (1997) Chest , vol.113 , pp. 251-253
    • Haponik, E.F.1    Shure, D.2
  • 8
    • 0033929302 scopus 로고    scopus 로고
    • Bronchoscopy in North America: Survey by the American Association for Bronchology
    • 10.1097/00128594-200007010-00004
    • HG Colt UBS Prakash KP Offord 1999 Bronchoscopy in North America: survey by the American Association for Bronchology J Bronchol 7 8 25 10.1097/00128594-200007010-00004
    • (1999) J Bronchol , vol.7 , pp. 8-25
    • Colt, H.G.1    Prakash, U.B.S.2    Offord, K.P.3
  • 10
    • 0035119119 scopus 로고    scopus 로고
    • CT fluoroscopy guidance for transbronchial needle aspiration: An experience in 35 patients
    • DOI 10.1378/chest.119.2.329
    • E Garpestad S Goldberg F Herth R Garland J LoCicero III R Thurer A Ernst 2001 CT fluoroscopy guidance for transbronchial needle aspiration: an experience in 35 patients Chest 119 329 332 1:STN:280:DC%2BD3M7psVKgtQ%3D%3D 10.1378/chest.119.2.329 11171705 (Pubitemid 32163739)
    • (2001) Chest , vol.119 , Issue.2 , pp. 329-332
    • Garpestad, E.1    Goldberg, S.N.2    Herth, F.3    Garland, R.4    LoCicero III, J.5    Thurer, R.6    Ernst, A.7
  • 11
    • 1642575308 scopus 로고    scopus 로고
    • Conventional vs Endobronchial Ultrasound-Guided Transbronchial Needle Aspiration: A Randomized Trial
    • DOI 10.1378/chest.125.1.322
    • F Herth HD Becker A Ernst 2004 Conventional versus endobronchial ultrasound-guided transbronchial needle aspiration: a randomised trial Chest 125 322 325 10.1378/chest.125.1.322 14718460 (Pubitemid 38114601)
    • (2004) Chest , vol.125 , Issue.1 , pp. 322-325
    • Herth, F.1    Becker, H.D.2    Ernst, A.3
  • 12
    • 14744298715 scopus 로고    scopus 로고
    • Endobronchial and endoscopic ultrasound-guided real-time fine-needle aspiration for mediastinal staging
    • 10.1183/09031936.05.00095404
    • RC Rintoul KM Skwarski JT Murchison WA Wallace WS Walker ID Penman 2006 Endobronchial and endoscopic ultrasound-guided real-time fine-needle aspiration for mediastinal staging Eur Respir J 25 416 421 10.1183/09031936.05.00095404
    • (2006) Eur Respir J , vol.25 , pp. 416-421
    • Rintoul, R.C.1    Skwarski, K.M.2    Murchison, J.T.3    Wallace, W.A.4    Walker, W.S.5    Penman, I.D.6
  • 14
    • 0030926263 scopus 로고    scopus 로고
    • Regional lymph node classification for lung cancer staging
    • 1:STN:280:DyaK2szjtVOnsg%3D%3D 10.1378/chest.111.6.1718 9187199
    • CF Mountain CM Dresler 1997 Regional lymph node classification for lung cancer staging Chest 111 1718 1723 1:STN:280:DyaK2szjtVOnsg%3D%3D 10.1378/chest.111.6.1718 9187199
    • (1997) Chest , vol.111 , pp. 1718-1723
    • Mountain, C.F.1    Dresler, C.M.2
  • 15
    • 0036180283 scopus 로고    scopus 로고
    • ERS/ATS statement on interventional pulmonology
    • DOI 10.1183/09031936.02.00204602
    • CT Bolliger PN Mathur 2002 ERS/ATS statement on interventional pulmonology Eur Respir J 19 356 373 1:STN:280:DC%2BD387jtVOqsA%3D%3D 10.1183/09031936.02.00204602 11866017 (Pubitemid 34162840)
    • (2002) European Respiratory Journal , vol.19 , Issue.2 , pp. 356-373
    • Bolliger, C.T.1    Mathur, P.N.2
  • 17
    • 0002009697 scopus 로고    scopus 로고
    • Transbronchial needle aspiration
    • J.F. Beamis P.N. Mathur (eds). McGraw-Hill New York
    • Mehta AC, Dasgupta A, Wang KP (1999) Transbronchial needle aspiration. In: Beamis JF, Mathur PN (eds) Interventional pulmonology. McGraw-Hill, New York, pp 241-254
    • (1999) Interventional Pulmonology , pp. 241-254
    • Mehta, A.C.1    Dasgupta, A.2    Wang, K.P.3
  • 18
    • 25444440096 scopus 로고    scopus 로고
    • Accuracy of transbronchial needle aspiration for mediastinal staging of non-small cell lung cancer: A meta-analysis
    • DOI 10.1136/thx.2005.041525
    • JE Holty WG Kuschner MK Gould 2005 Accuracy of transbronchial needle aspiration for mediastinal staging of non-small cell lung cancer: a meta-analysis Thorax 60 949 955 10.1136/thx.2005.041525 15994251 (Pubitemid 41598211)
    • (2005) Thorax , vol.60 , Issue.11 , pp. 949-955
    • Holty, J.-E.C.1    Kuschner, W.G.2    Gould, M.K.3
  • 20
    • 0034104259 scopus 로고    scopus 로고
    • Utility of on-site cytopathology assessment for bronchoscopic evaluation of lung masses and adeopathy
    • 1:STN:280:DC%2BD3c3jtFKisw%3D%3D 10.1378/chest.117.4.1186 10767258
    • GB Diette P White P Terry M Jenckes D Rosenthal HR Rubin 2000 Utility of on-site cytopathology assessment for bronchoscopic evaluation of lung masses and adeopathy Chest 117 1186 1190 1:STN:280:DC%2BD3c3jtFKisw%3D%3D 10.1378/chest.117.4.1186 10767258
    • (2000) Chest , vol.117 , pp. 1186-1190
    • Diette, G.B.1    White, P.2    Terry, P.3    Jenckes, M.4    Rosenthal, D.5    Rubin, H.R.6
  • 23
    • 21844458949 scopus 로고    scopus 로고
    • Transbronchial needle aspirates: Comparison of two preparation methods
    • 10.1378/chest.127.6.2015 15947314
    • AH Diacon MM Schuurmans J Theron K Brundyn M Louw CA Wright CT Bolliger 2005 Transbronchial needle aspirates: comparison of two preparation methods Chest 127 2015 2018 10.1378/chest.127.6.2015 15947314
    • (2005) Chest , vol.127 , pp. 2015-2018
    • Diacon, A.H.1    Schuurmans, M.M.2    Theron, J.3    Brundyn, K.4    Louw, M.5    Wright, C.A.6    Bolliger, C.T.7
  • 25
    • 34250880220 scopus 로고    scopus 로고
    • Can mediastinal nodal mobility explain the low yield rates for transbronchial needle aspiration without real-time imaging?
    • DOI 10.1378/chest.06-2964
    • AH Piet FJ Lagerwaard PW Kunst JR de Koste BJ Slotman S Senan 2007 Can mediastinal nodal mobility explain the low yield rates for transbronchial needle aspiration without real-time imaging? Chest 131 1783 1787 10.1378/chest.06-2964 17565020 (Pubitemid 46981634)
    • (2007) Chest , vol.131 , Issue.6 , pp. 1783-1787
    • Piet, A.H.M.1    Lagerwaard, F.J.2    Kunst, P.W.A.3    Van Sornsen De Koste, J.R.4    Slotman, B.J.5    Senan, S.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.