메뉴 건너뛰기




Volumn 17, Issue 5, 2010, Pages 1461-1469

PDC measurements to assess machine insulation

Author keywords

dielectric response; Machine insulation; polarization and depolarization currents

Indexed keywords

CHARGE AND DISCHARGE; COMMERCIAL AVAILABILITY; COMMONLY USED; DIAGNOSTIC TESTS; DIELECTRIC RESPONSE; INSULATION SYSTEM; MACHINE INSULATION; ON-MACHINES; POLARIZATION AND DEPOLARIZATION CURRENTS; POLARIZATION/DEPOLARIZATION CURRENT; STATOR INSULATION SYSTEMS; STEP VOLTAGES; WINDING INSULATION;

EID: 77957902073     PISSN: 10709878     EISSN: None     Source Type: Journal    
DOI: 10.1109/TDEI.2010.5595547     Document Type: Article
Times cited : (42)

References (20)
  • 6
    • 33845901496 scopus 로고    scopus 로고
    • Modeling of the low-frequency dielectric response of rotating machine stator insulation system
    • DOI 10.1109/CEIDP.2005.1560670, 1560670, 2005 Annual Report Conference on Electrical Insulation and Dielectric Phenomena, CEIDP '05
    • E. David and L. Lamarre, "Modeling of the low-frequency dielectric response of rotating machine stator insulation system", IEEE Conf. Electr. Insul. Dielectr. Phenomena (CEIDP), pp. 257-260, 2005. (Pubitemid 46016186)
    • (2005) Annual Report - Conference on Electrical Insulation and Dielectric Phenomena, CEIDP , vol.2005 , pp. 257-260
    • David, E.1    Lamarre, L.2
  • 7
    • 33846238200 scopus 로고    scopus 로고
    • The use of transient current for the evaluation of the condition of rotor and stator insulation systems of large synchronous rotating machines
    • DOI 10.1109/EEIC.2005.1566262, 1566262, Proceedings - Electrical Insulation Conference and Electrical Manufacturing Expo, 2005
    • C. Paynot, L. Lamarre, E. David and R. Taghizad, "The use of transient current for the evaluation of the condition of rotoric and statoric insulation systems of large synchronous rotating machines", IEEE Electr. Insul. Conf. (EIC), pp. 78-81, 2005. (Pubitemid 46090918)
    • (2005) Proceedings - Electrical Insulation Conference and Electrical Manufacturing Expo, 2005 , vol.2005 , pp. 78-81
    • Paynot, C.1    Lamarre, L.2    David, E.3    Taghizad, R.4
  • 8
    • 34249715253 scopus 로고    scopus 로고
    • Condition assessment of rotating machine winding insulation by analysis of charging and discharging currents
    • 1665326, Conference Record of the 2006 IEEE International Symposium on Electrical Insulation
    • G. R. Soltani and E. David, "Condition Assessment of Rotating Machine Winding Insulation by Analysis of Charging and Discharging Currents" IEEE Intern. Sympos. Electr. Insul. (ISEI), pp. 336-339, 2006. (Pubitemid 46823287)
    • (2007) Conference Record of IEEE International Symposium on Electrical Insulation , vol.2007 , pp. 336-339
    • Soltani, G.R.1    David, E.2
  • 10
    • 33847727416 scopus 로고    scopus 로고
    • Low-frequency dielectric response of epoxy-mica insulated generator bars during multi-stress aging
    • DOI 10.1109/TDEI.2007.302890
    • E. David and L. Lamarre, "Low-Frequency Dielectric response of Epoxy-Mica Insulated Generator Bars During Multi-Stress Aging", IEEE Trans. Dielectr. Electr. Insul., Vol. 14, pp. 212-226, 2007. (Pubitemid 46375899)
    • (2007) IEEE Transactions on Dielectrics and Electrical Insulation , vol.14 , Issue.1 , pp. 212-226
    • David, E.1    Lamarre, L.2
  • 11
    • 77950691160 scopus 로고    scopus 로고
    • Progress in DC testing of generator stator windings: Theoretical considerations and laboratory tests
    • E. David and L. Lamarre, "Progress in DC Testing of Generator Stator Windings: Theoretical Considerations and Laboratory Tests", IEEE Trans. Energy Conversion, Vol. 25, pp. 49-58, 2010.
    • (2010) IEEE Trans. Energy Conversion , vol.25 , pp. 49-58
    • David, E.1    Lamarre, L.2
  • 12
    • 51849106131 scopus 로고    scopus 로고
    • Measurements of polarization/depolarization currents for modern epoxy-mica bars in different conditions
    • Nashville, USA
    • E. David, L. Lamarre and D. N. Nguyen, "Measurements of polarization/depolarization currents for modern epoxy-mica bars in different conditions", IEEE Electr. Insul. Conf. (EIC), Nashville, USA, pp. 202-206, 2007.
    • (2007) IEEE Electr. Insul. Conf. (EIC) , pp. 202-206
    • David, E.1    Lamarre, L.2    Nguyen, D.N.3
  • 13
    • 33646398368 scopus 로고    scopus 로고
    • Dielectric response studies on insulation system of high voltage rotating machines
    • M. Farahani, H. Borsi and E. Gockenbach, "Dielectric Response Studies on Insulation System of High Voltage Rotating Machines", IEEE Trans. Dielectr. Electr. Insul., 13, pp. 383-393, 2006.
    • (2006) IEEE Trans. Dielectr. Electr. Insul. , vol.13 , pp. 383-393
    • Farahani, M.1    Borsi, H.2    Gockenbach, E.3
  • 14
    • 70449640303 scopus 로고    scopus 로고
    • Field experience in insulation diagnosis of industrial high voltage motors using dielectric response technique
    • S. A. Bhumiwat, "Field Experience in Insulation Diagnosis of Industrial High Voltage Motors using Dielectric Response Technique", IEEE Electr. Insul. Conf. (EIC), pp. 454-457, 2009.
    • (2009) IEEE Electr. Insul. Conf. (EIC) , pp. 454-457
    • Bhumiwat, S.A.1
  • 15
    • 84876759637 scopus 로고    scopus 로고
    • Practical experiences on condition assessment of stator insulation using polarisation/depolarisation current technique
    • Paris, France
    • S. A. Bhumiwat and S. Bhumiwat, "Practical experiences on condition assessment of Stator insulation using Polarisation/Depolarisation Current technique", CIGRE 2008 Session, Paris, France, pp. D1-210, 2008.
    • (2008) CIGRE 2008 Session
    • Bhumiwat, S.A.1    Bhumiwat, S.2
  • 19
    • 77957927439 scopus 로고    scopus 로고
    • Impact of humidity on the dielectric response of rotating machine insulation system
    • this issue
    • R. Soltani, E. David and L. Lamarre, "Impact of Humidity on the Dielectric Response of Rotating Machine Insulation System", IEEE Trans. on Dielectr. and Electr. Insul., Vol. 17, 2010 (this issue).
    • (2010) IEEE Trans. on Dielectr. and Electr. Insul. , vol.17
    • Soltani, R.1    David, E.2    Lamarre, L.3
  • 20
    • 0000855110 scopus 로고
    • An approximate method for deducing dielectric loss factor from direct-current measurements
    • B. V. Hamon, "An Approximate Method for Deducing Dielectric Loss Factor from Direct-Current Measurements", Proc. IEE, Vol. 99, pp. 151-155, 1952.
    • (1952) Proc. IEE , vol.99 , pp. 151-155
    • Hamon, B.V.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.