메뉴 건너뛰기




Volumn 12, Issue 10, 2010, Pages 1439-1445

An impaired renal function and advanced heart failure represent independent predictors of the incidence of malignant ventricular arrhythmias in patients with an implantable cardioverter/defibrillator for primary prevention

Author keywords

Advanced heart failure; Appropriate and inappropriate therapy; Implantable cardioverter defibrillator; Primary prevention; Risk stratification; Sudden cardiac death

Indexed keywords

CREATININE;

EID: 77957735444     PISSN: 10995129     EISSN: 15322092     Source Type: Journal    
DOI: 10.1093/europace/euq283     Document Type: Article
Times cited : (12)

References (18)
  • 1
    • 0037149716 scopus 로고    scopus 로고
    • Prophylactic implantation of a defibrillator in patients with myocardial infarction and reduced ejection fraction
    • Moss AJ, Zareba W, Hall WJ, Klein H, Wilber DJ, Cannom DS et al. Prophylactic implantation of a defibrillator in patients with myocardial infarction and reduced ejection fraction. N Engl J Med 2002;346:877-83.
    • (2002) N. Engl. J. Med. , vol.346 , pp. 877-883
    • Moss, A.J.1    Zareba, W.2    Hall, W.J.3    Klein, H.4    Wilber, D.J.5    Cannom, D.S.6
  • 2
    • 1542724422 scopus 로고    scopus 로고
    • Time dependence of mortality risk and defibrillator benefit after myocardial infarction
    • Wilber DJ, Zareba W, Hall WJ, Brown MW, Lin AC, Andrews ML et al. Time dependence of mortality risk and defibrillator benefit after myocardial infarction. Circulation 2004;109:1082-4.
    • (2004) Circulation , vol.109 , pp. 1082-1084
    • Wilber, D.J.1    Zareba, W.2    Hall, W.J.3    Brown, M.W.4    Lin, A.C.5    Andrews, M.L.6
  • 3
    • 33646186913 scopus 로고    scopus 로고
    • Time dependence of defibrillator benefit after coronary revascularization in the multicenter automatic defibrillator implantation trial (MADIT)-II
    • Goldenberg I, Moss AJ, McNitt S, Zareba W, Hall WJ, Andrews ML et al. Time dependence of defibrillator benefit after coronary revascularization in the Multicenter Automatic Defibrillator Implantation Trial (MADIT)-II. J Am Coll Cardiol 2006;47:1811-7.
    • (2006) J. Am. Coll. Cardiol. , vol.47 , pp. 1811-1817
    • Goldenberg, I.1    Moss, A.J.2    McNitt, S.3    Zareba, W.4    Hall, W.J.5    Andrews, M.L.6
  • 4
    • 0033576804 scopus 로고    scopus 로고
    • A randomized study of the prevention of sudden death in patients with coronary artery disease. Multicenter unsustained tachycardia trial investigators
    • Buxton AE, Lee KL, Fisher JD, Josephson ME, Prystowsky EN, Hafley G. A randomized study of the prevention of sudden death in patients with coronary artery disease. Multicenter Unsustained Tachycardia Trial Investigators. N Engl J Med 1999;341:1882-90.
    • (1999) N. Engl. J. Med. , vol.341 , pp. 1882-1890
    • Buxton, A.E.1    Lee, K.L.2    Fisher, J.D.3    Josephson, M.E.4    Prystowsky, E.N.5    Hafley, G.6
  • 6
    • 2442572117 scopus 로고    scopus 로고
    • Prophylactic defibrillator implantation in patients with nonischemic dilated cardiomyopathy
    • Kadish A, Dyer A, Daubert JP, Quigg R, Estes NA, Anderson KP et al. Prophylactic defibrillator implantation in patients with nonischemic dilated cardiomyopathy. N Engl J Med 2004;350:2151-8.
    • (2004) N. Engl. J. Med. , vol.350 , pp. 2151-2158
    • Kadish, A.1    Dyer, A.2    Daubert, J.P.3    Quigg, R.4    Estes, N.A.5    Anderson, K.P.6
  • 8
    • 33846296628 scopus 로고    scopus 로고
    • Incidence and characteristics of appropriate and inappropriate therapies in recipients of ICD implanted for primary prevention of sudden cardiac death
    • Kreuz J, Balta O, Liliegren N, Mellert F, Esmailzadeh B, Nickenig G et al. Incidence and Characteristics of Appropriate and Inappropriate Therapies in Recipients of ICD Implanted for Primary Prevention of Sudden Cardiac Death. PACE 2007;30: S1-S3.
    • (2007) PACE , vol.30
    • Kreuz, J.1    Balta, O.2    Liliegren, N.3    Mellert, F.4    Esmailzadeh, B.5    Nickenig, G.6
  • 9
    • 20944440946 scopus 로고    scopus 로고
    • Long-term incidence of malignant ventricular arrhythmia and shock therapy in patients with primary defibrillator implantation does not differ from event rates in patients treated for survived cardiac arrest
    • Backenkohler U, Erdogan A, Steen-Mueller MK, Kuhlmann C, Most A, Schaefer C et al. Long-term incidence of malignant ventricular arrhythmia and shock therapy in patients with primary defibrillator implantation does not differ from event rates in patients treated for survived cardiac arrest. J Cardiovasc Electrophysiol 2005;16:478-82.
    • (2005) J. Cardiovasc. Electrophysiol , vol.16 , pp. 478-482
    • Backenkohler, U.1    Erdogan, A.2    Steen-Mueller, M.K.3    Kuhlmann, C.4    Most, A.5    Schaefer, C.6
  • 10
  • 11
    • 56749164951 scopus 로고    scopus 로고
    • Benefit of primary prevention implantable cardioverter-defibrillators in the setting of chronic kidney disease: A decision model analysis
    • Amin MS, Fox AD, Kalahasty G, Shepard RK, Wood MA, Ellenbogen KA. Benefit of primary prevention implantable cardioverter-defibrillators in the setting of chronic kidney disease: a decision model analysis. J Cardiovasc Electrophysiol 2008;19:1275-80.
    • (2008) J. Cardiovasc. Electrophysiol , vol.19 , pp. 1275-1280
    • Amin, M.S.1    Fox, A.D.2    Kalahasty, G.3    Shepard, R.K.4    Wood, M.A.5    Ellenbogen, K.A.6
  • 12
    • 33847403128 scopus 로고    scopus 로고
    • Poor prognosis for patients with chronic kidney disease despite ICD therapy for the primary prevention of sudden death
    • Cuculich PS, Sánchez JM, Kerzner R, Greenberg SL, Sengupta J, Chen J et al. Poor prognosis for patients with chronic kidney disease despite ICD therapy for the primary prevention of sudden death. Pacing Clin Electrophysiol 2007;30:207-13.
    • (2007) Pacing Clin. Electrophysiol , vol.30 , pp. 207-213
    • Cuculich, P.S.1    Sánchez, J.M.2    Kerzner, R.3    Greenberg, S.L.4    Sengupta, J.5    Chen, J.6
  • 14
    • 33745685677 scopus 로고    scopus 로고
    • A comparison of empiric to physician-tailored programming of implantable cardioverterdefibrillators: Results from the prospective randomized multicenter EMPIRIC trial
    • Wilkoff BL, Ousdigian KT, Sterns LD, Wang ZJ, Wilson RD, Morgan JM. A comparison of empiric to physician-tailored programming of implantable cardioverterdefibrillators: results from the prospective randomized multicenter EMPIRIC trial. J Am Coll Cardiol 2006;48:330-9.
    • (2006) J. Am. Coll. Cardiol. , vol.48 , pp. 330-339
    • Wilkoff, B.L.1    Ousdigian, K.T.2    Sterns, L.D.3    Wang, Z.J.4    Wilson, R.D.5    Morgan, J.M.6
  • 15
    • 30444439243 scopus 로고    scopus 로고
    • Comparison of beta-blockers, amiodarone plus beta-blockers, or sotalol for prevention of shocks from implantable cardioverter defibrillators: The OPTIC Study: A randomized trial
    • Connolly SJ, Dorian P, Roberts RS, Gent M, Bailin S, Fain ES et al. Comparison of beta-blockers, amiodarone plus beta-blockers, or sotalol for prevention of shocks from implantable cardioverter defibrillators: the OPTIC Study: a randomized trial. JAMA 2006;295:165-71.
    • (2006) JAMA , vol.295 , pp. 165-171
    • Connolly, S.J.1    Dorian, P.2    Roberts, R.S.3    Gent, M.4    Bailin, S.5    Fain, E.S.6
  • 16
    • 33746614024 scopus 로고    scopus 로고
    • Design of the primary prevention parameters evaluation (PREPARE) trial of implantable cardioverter defibrillators to reduce patients morbidity
    • Wilkoff BL, Stern R, Williamson B, Wathen M, Holloman K, Fieberg A et al. Design of the primary prevention parameters evaluation (PREPARE) trial of implantable cardioverter defibrillators to reduce patients morbidity. Trials 2006;7:18.
    • (2006) Trials , vol.7 , pp. 18
    • Wilkoff, B.L.1    Stern, R.2    Williamson, B.3    Wathen, M.4    Holloman, K.5    Fieberg, A.6
  • 17
    • 48449088263 scopus 로고    scopus 로고
    • Strategic programming of detection and therapy parameters in implantable cardioverter-defibrillators reduces shocks in primary prevention patients: Results from the PREPARE (primary prevention parameters evaluation) study
    • Wilkoff BL, Williamson BD, Stern RS, Moore SL, Lu F, Lee SW, Birgersdotter-Green UM et al. Strategic programming of detection and therapy parameters in implantable cardioverter-defibrillators reduces shocks in primary prevention patients: results from the PREPARE (Primary Prevention Parameters Evaluation) study. J Am Coll Cardiol 2008;52:541-50.
    • (2008) J. Am. Coll. Cardiol. , vol.52 , pp. 541-550
    • Wilkoff, B.L.1    Williamson, B.D.2    Stern, R.S.3    Moore, S.L.4    Lu, F.5    Lee, S.W.6    Birgersdotter-Green, U.M.7
  • 18
    • 66649134745 scopus 로고    scopus 로고
    • Avoid delivering therapies for nonsustained fast ventricular tachyarrhythmia in patients with implantable cardioverter/defibrillator: The ADVANCE III Trial
    • Schwab JO, Gasparini M, Lunati M, Proclemer A, Kaup B, Santi E et al. Avoid delivering therapies for nonsustained fast ventricular tachyarrhythmia in patients with implantable cardioverter/defibrillator: the ADVANCE III Trial. J Cardiovasc Electrophysiol 2009;20:663-6.
    • (2009) J. Cardiovasc. Electrophysiol , vol.20 , pp. 663-666
    • Schwab, J.O.1    Gasparini, M.2    Lunati, M.3    Proclemer, A.4    Kaup, B.5    Santi, E.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.