메뉴 건너뛰기




Volumn 30, Issue SUPPL. 1, 2007, Pages

Incidence and characteristics of appropriate and inappropriate therapies in recipients of ICD implanted for primary prevention of sudden cardiac death

Author keywords

Implantable cardioverter defibrillator; Primary prevention; Sudden cardiac death; Ventricular tachyarrhythmia

Indexed keywords

ADULT; AGED; ARTICLE; CONTROLLED STUDY; DEFIBRILLATOR; FEMALE; FOLLOW UP; HEART VENTRICLE TACHYCARDIA; HUMAN; IMPLANTATION; MAJOR CLINICAL STUDY; MALE; PRIMARY PREVENTION; SUDDEN DEATH; TREATMENT INDICATION; TREATMENT OUTCOME;

EID: 33846296628     PISSN: 01478389     EISSN: 15408159     Source Type: Journal    
DOI: 10.1111/j.1540-8159.2007.00621.x     Document Type: Article
Times cited : (9)

References (7)
  • 1
    • 0037149716 scopus 로고    scopus 로고
    • Prophylactic implantation of a defibrillator in patients with myocardial infarction and reduced ejection fraction
    • Moss AJ, Zareba W, Hall WJ, Klein H, Wilber DJ, Cannom DS, Daubert JP, et al. Prophylactic implantation of a defibrillator in patients with myocardial infarction and reduced ejection fraction. N Engl J Med 2002; 346:877-883.
    • (2002) N Engl J Med , vol.346 , pp. 877-883
    • Moss, A.J.1    Zareba, W.2    Hall, W.J.3    Klein, H.4    Wilber, D.J.5    Cannom, D.S.6    Daubert, J.P.7
  • 3
    • 0242382791 scopus 로고    scopus 로고
    • Implantable cardioverter defibrillator recipients: Quality of life in recipients with and without ICD shock delivery: A prospective study
    • Kamphuis HC, de Leeuw JR, Derksen R, Hauer RN, Winnubst JA. Implantable cardioverter defibrillator recipients: Quality of life in recipients with and without ICD shock delivery: A prospective study. Europace 2003; 5:381-389.
    • (2003) Europace , vol.5 , pp. 381-389
    • Kamphuis, H.C.1    de Leeuw, J.R.2    Derksen, R.3    Hauer, R.N.4    Winnubst, J.A.5
  • 4
    • 20944440946 scopus 로고    scopus 로고
    • Long-term incidence of malignant ventricular arrhythmia and shock therapy in patients with primary defibrillator implantation does not differ from event rates in patients treated for survived cardiac arrest
    • Backenkohler U, Erdogan A, Steen-Mueller MK, Kuhlmann C, Most A, Schaefer C, Stertmann W, et al. Long-term incidence of malignant ventricular arrhythmia and shock therapy in patients with primary defibrillator implantation does not differ from event rates in patients treated for survived cardiac arrest. J Cardiovasc Electrophysiol 2005; 16:478-482
    • (2005) J Cardiovasc Electrophysiol , vol.16 , pp. 478-482
    • Backenkohler, U.1    Erdogan, A.2    Steen-Mueller, M.K.3    Kuhlmann, C.4    Most, A.5    Schaefer, C.6    Stertmann, W.7
  • 5
    • 30444439243 scopus 로고    scopus 로고
    • Comparison of beta-blockers, amiodarone plus beta-blockers, or sotalol for prevention of shocks from implantable cardioverter defibrillators: The OPTIC Study: A randomized trial
    • Connolly SJ, Dorian P, Roberts RS, Gent M, Bailin S, Fain ES, Thorpe K, et al. Comparison of beta-blockers, amiodarone plus beta-blockers, or sotalol for prevention of shocks from implantable cardioverter defibrillators: The OPTIC Study: A randomized trial. JAMA 2006; 295:165-171.
    • (2006) JAMA , vol.295 , pp. 165-171
    • Connolly, S.J.1    Dorian, P.2    Roberts, R.S.3    Gent, M.4    Bailin, S.5    Fain, E.S.6    Thorpe, K.7
  • 7
    • 33846313995 scopus 로고    scopus 로고
    • Can a standardized ICD-programming approach match physician tailored programming in preventing shocks post-ICD implantation (abstract)
    • Sterns LD, Wilkoff BL, Morgan JM, Ousdigian KT, Wang ZJ, Peterson BJ, Wilson RD. Can a standardized ICD-programming approach match physician tailored programming in preventing shocks post-ICD implantation (abstract). Heart Rhythm 2005;2:S126.
    • (2005) Heart Rhythm , vol.2
    • Sterns, L.D.1    Wilkoff, B.L.2    Morgan, J.M.3    Ousdigian, K.T.4    Wang, Z.J.5    Peterson, B.J.6    Wilson, R.D.7


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.