-
1
-
-
19644382801
-
New optional IVC filter for percutaneous retrievalin vitro evaluation of embolus capturing efficiency
-
R.W. Gnther, J. Neuerburg, A. Mossdorf, J. Pfeffer, A.R. Høj, and A. Mølgaard-Nielsen New optional IVC filter for percutaneous retrievalin vitro evaluation of embolus capturing efficiency Rofo 177 2005 632 636
-
(2005)
Rofo
, vol.177
, pp. 632-636
-
-
Gnther, R.W.1
Neuerburg, J.2
Mossdorf, A.3
Pfeffer, J.4
Høj, A.R.5
Mølgaard-Nielsen, A.6
-
3
-
-
0026782625
-
Experimental embolic capture by asymmetric Greenfield filters
-
L.J. Greenfield, and M.C. Proctor Experimental embolic capture by asymmetric Greenfield filters J Vasc Surg 16 1992 436 443 discussion 443-4
-
(1992)
J Vasc Surg
, vol.16
, pp. 436-443
-
-
Greenfield, L.J.1
Proctor, M.C.2
-
4
-
-
49749142985
-
Factors associated with failed retrieval of the Gnther Tulip inferior vena cava filter
-
J.S. Marquess, C.T. Burke, A.H. Beecham, R.G. Dixon, J.M. Stavas, and A.A. Sag Factors associated with failed retrieval of the Gnther Tulip inferior vena cava filter J Vasc Interv Radiol 19 2008 1321 1327
-
(2008)
J Vasc Interv Radiol
, vol.19
, pp. 1321-1327
-
-
Marquess, J.S.1
Burke, C.T.2
Beecham, A.H.3
Dixon, R.G.4
Stavas, J.M.5
Sag, A.A.6
-
5
-
-
33845430407
-
Gunther Tulip retrievable inferior vena caval filters: Indications, efficacy, retrieval, and complications
-
S. Looby, M.F. Given, T. Geoghegan, A. McErlean, and M.J. Lee Gunther Tulip retrievable inferior vena caval filters: indications, efficacy, retrieval, and complications Cardiovasc Intervent Radiol 30 2007 59 65
-
(2007)
Cardiovasc Intervent Radiol
, vol.30
, pp. 59-65
-
-
Looby, S.1
Given, M.F.2
Geoghegan, T.3
McErlean, A.4
Lee, M.J.5
-
6
-
-
0347995041
-
Clinical experience with retrievable Gnther Tulip vena cava filters
-
S. Wicky, F. Doenz, J.Y. Meuwly, F. Portier, P. Schnyder, and A. Denys Clinical experience with retrievable Gnther Tulip vena cava filters J Endovasc Ther 10 2003 994 1000
-
(2003)
J Endovasc Ther
, vol.10
, pp. 994-1000
-
-
Wicky, S.1
Doenz, F.2
Meuwly, J.Y.3
Portier, F.4
Schnyder, P.5
Denys, A.6
-
7
-
-
69349090618
-
Safety and effectiveness of the Celect inferior vena cava filter: Preliminary results
-
M.J. Sangwaiya, T.C. Marentis, T.G. Walker, M. Stecker, S.T. Wicky, and S.P. Kalva Safety and effectiveness of the Celect inferior vena cava filter: preliminary results J Vasc Interv Radiol 20 2009 1188 1192
-
(2009)
J Vasc Interv Radiol
, vol.20
, pp. 1188-1192
-
-
Sangwaiya, M.J.1
Marentis, T.C.2
Walker, T.G.3
Stecker, M.4
Wicky, S.T.5
Kalva, S.P.6
-
8
-
-
65349109445
-
Initial experience in 115 patients with the retrievable Cook Celect vena cava filter
-
O. Doody, M.F. Given, H. Kavnoudias, M. Street, K.R. Thomson, and S.M. Lyon Initial experience in 115 patients with the retrievable Cook Celect vena cava filter J1 Med Imaging Radiat Oncol 53 2009 64 68
-
(2009)
J1 Med Imaging Radiat Oncol
, vol.53
, pp. 64-68
-
-
Doody, O.1
Given, M.F.2
Kavnoudias, H.3
Street, M.4
Thomson, K.R.5
Lyon, S.M.6
-
9
-
-
55649092214
-
Retrievable Gunther Tulip inferior vena cava filter: Experience in 317 patients
-
M.F. Given, B.C. McDonald, P. Brookfield, L. Niggemeyer, T. Kossmann, and D.K. Varma Retrievable Gunther Tulip inferior vena cava filter: experience in 317 patients J Med Imaging Radiat Oncol 52 2008 452 457
-
(2008)
J Med Imaging Radiat Oncol
, vol.52
, pp. 452-457
-
-
Given, M.F.1
McDonald, B.C.2
Brookfield, P.3
Niggemeyer, L.4
Kossmann, T.5
Varma, D.K.6
-
10
-
-
40949146154
-
The Gnther-Tulip retrievable IVC filter: Clinical experience in 118 consecutive patients
-
S. Ota, N. Yamada, A. Tsuji, K. Ishikura, M. Nakamura, and N. Isaka The Gnther-Tulip retrievable IVC filter: clinical experience in 118 consecutive patients Circ J 72 2008 287 292
-
(2008)
Circ J
, vol.72
, pp. 287-292
-
-
Ota, S.1
Yamada, N.2
Tsuji, A.3
Ishikura, K.4
Nakamura, M.5
Isaka, N.6
-
11
-
-
42649124593
-
Analysis of tilt of the Gnther Tulip filter
-
A.A. Sag, J.M. Stavas, C.T. Burke, R.G. Dixon, J.S. Marquess, and M.A. Mauro Analysis of tilt of the Gnther Tulip filter J Vasc Interv Radiol 19 2008 669 676
-
(2008)
J Vasc Interv Radiol
, vol.19
, pp. 669-676
-
-
Sag, A.A.1
Stavas, J.M.2
Burke, C.T.3
Dixon, R.G.4
Marquess, J.S.5
Mauro, M.A.6
-
12
-
-
0015608691
-
A new intracaval filter permitting continued flow and resolution of emboli
-
L.J. Greenfield, J.R. McCurdy, P.P. Brown, and R.C. Elkins A new intracaval filter permitting continued flow and resolution of emboli Surgery 73 1973 599 606
-
(1973)
Surgery
, vol.73
, pp. 599-606
-
-
Greenfield, L.J.1
McCurdy, J.R.2
Brown, P.P.3
Elkins, R.C.4
-
13
-
-
38449108685
-
Long-term retrieval of modified Gnther Tulip vena cava filters: An animal study
-
A. Buecker, F.F. Behrendt, R. Knchel, S. Kinzel, A. Mølgaard- Nielsen, and J. Neuerburg Long-term retrieval of modified Gnther Tulip vena cava filters: an animal study Invest Radiol 42 2007 692 696
-
(2007)
Invest Radiol
, vol.42
, pp. 692-696
-
-
Buecker, A.1
Behrendt, F.F.2
Knchel, R.3
Kinzel, S.4
Mølgaard-Nielsen, A.5
Neuerburg, J.6
|