메뉴 건너뛰기




Volumn 52, Issue 3, 2010, Pages 15-27

Antenna proximity effects for talk and data modes in mobile phones

Author keywords

antenna measurements; Antenna proximity factors; body loss; efficiency; FDTD methods; hand phantom; land mobile radio cellular systems; land mobile radio equipment; mobile antennas

Indexed keywords

ANTENNA MEASUREMENT; ANTENNA PROXIMITY FACTORS; BODY LOSS; FDTD METHOD; HAND PHANTOM; LAND MOBILE RADIO CELLULAR SYSTEMS; LAND MOBILE RADIO EQUIPMENT;

EID: 77957550134     PISSN: 10459243     EISSN: None     Source Type: Journal    
DOI: 10.1109/MAP.2010.5586570     Document Type: Article
Times cited : (68)

References (27)
  • 2
    • 0029207527 scopus 로고
    • EM interaction of handset Antennas and a human in personal communications
    • January
    • M. A. Jensen and Y. Rahmat-Samii, "EM Interaction of Handset Antennas and a Human in Personal Communications," Proceedings of the IEEE, 83, 1, January 1995, pp. 7- 17.
    • (1995) Proceedings of the IEEE , vol.83 , Issue.1 , pp. 7-17
    • Jensen, M.A.1    Rahmat-Samii, Y.2
  • 3
    • 37249069379 scopus 로고    scopus 로고
    • Effect of the human body on total radiated power and the 3-d radiation pattern of mobile handsets
    • December
    • J. Krogerus, J. Toivanen, C. Icheln, and P. Vainikainen, "Effect of the Human Body on Total Radiated Power and the 3-D Radiation Pattern of Mobile Handsets," IEEE Transactions on Instrumentation and Measurement, IMS-56, 6, December 2007, pp. 2375-2385.
    • (2007) IEEE Transactions on Instrumentation and Measurement , vol.IMS-56 , Issue.6 , pp. 2375-2385
    • Krogerus, J.1    Toivanen, J.2    Icheln, C.3    Vainikainen, P.4
  • 4
    • 85060741709 scopus 로고    scopus 로고
    • Instrumen tation, and ProcedureS- Part I: Procedure to Determine the Specific Absorption Rate (SAR) for Hand-Held DeviceSUsed in Close Proximity to the Ear (Frequency Range of 300 MHz to 3 GHz), IEC
    • Human Exposure to Radio Frequency FieldSfrom Hand-Held and Body-Mounted WirelesSCommunication DeviceS- Human Models, Instrumen tation, and ProcedureS- Part I: Procedure to Determine the Specific Absorption Rate (SAR) for Hand-Held DeviceSUsed in Close Proximity to the Ear (Frequency Range of 300 MHz to 3 GHz), I EC 62209-62211, 2005.
    • (2005) Human Exposure to Radio Frequency FieldSfrom Hand-Held and Body-Mounted WirelesSCommunication DeviceS- Human Models , pp. 62209-62211
  • 5
    • 0031141699 scopus 로고    scopus 로고
    • Dosimetric evaluation of handheld mobile communicationSequipment with known precision
    • May
    • N. Kuster, R. Kastle, and T. Schmid, "Dosimetric Evaluation of Handheld Mobile CommunicationSEquipment with Known Precision," IEICE Transactions on Communications, 80-B, 5, May 1997, pp. 645-652.
    • (1997) IEICE Transactions on Communications , vol.80 B , Issue.5 , pp. 645-652
    • Kuster, N.1    Kastle, R.2    Schmid, T.3
  • 6
  • 7
    • 0029183655 scopus 로고
    • Some numerical methodsfor dosimetry: Extremely low frequenciesto microwave frequencies
    • O. P. Gandhi, "Some Numerical MethodSfor Dosimetry: Extremely Low FrequencieSto Microwave Frequencies," Radio Science, 30, 199 5, pp. 161-177.
    • (1995) Radio Science , vol.30 , pp. 161-177
    • Gandhi, O.P.1
  • 8
    • 0030257469 scopus 로고    scopus 로고
    • CharacteristicSof the SAR distributionsin a head exposed to electromagnetic fieldsradiated by a hand-held portable radio
    • October
    • S. I. Watanabe, H. Taki, T. Nojima, and O. Fujiwara, " CharacteristicSof the SAR DistributionSin a Head Exposed to Electromagnetic FieldSRadiated by a Hand-Held Portable Radio," IEEE Transactions on Microwave Theory and Techniques, MTT- 44, 10, October 1996, pp. 1874- 1883.
    • (1996) IEEE Transactions on Microwave Theory and Techniques , vol.MTT-44 , Issue.10 , pp. 1874-1883
    • Watanabe, S.I.1    Taki, H.2    Nojima, T.3    Fujiwara, O.4
  • 10
    • 33947393177 scopus 로고    scopus 로고
    • Analysis of mobile phone antenna impedance variationswith user proximity
    • February
    • K. R. Boyle, Y. Yuan, and L. P. Ligthart, "Analysis of Mobile Phone Antenna Impedance VariationSWith User Proximity, " IEEE Transactions on Antennas and Propagation, AP-55, 2, February 2007,pp. 364-372.
    • (2007) IEEE Transactions on Antennas and Propagation , vol.AP-55 , Issue.2 , pp. 364-372
    • Boyle, K.R.1    Yuan, Y.2    Ligthart, L.P.3
  • 16
    • 0035328791 scopus 로고    scopus 로고
    • An Analysis of the performance of a handset diversity antenna influenced by head, hand, and shoulder effectsat 900 MHz I. effective gain characteristics
    • May
    • K. Ogawa and T. Matsuyoshi, "An Analysis of the Performance of a Handset Diversity Antenna Influenced by Head, Hand, and Shoulder EffectSat 900 MHz I. Effective Gain Characteristics," IEEE Transactions on Vehicular Technology, 50, 3, May 2001, pp. 830-844.
    • (2001) IEEE Transactions on Vehicular Technology , vol.50 , Issue.3 , pp. 830-844
    • Ogawa, K.1    Matsuyoshi, T.2
  • 17
    • 0035328428 scopus 로고    scopus 로고
    • An analysis of the performance of a handset diversity antenna influenced by head, hand, and shoulder effectsat 900 MHz II. Correlation characteristics
    • May
    • K. Ogawa, T. Matsuyoshi, and K. Monma, "An Analysis of the Performance of a Handset Diversity Antenna Influenced by Head, Hand, and Shoulder EffectSat 900 MHz II. Correlation Characteristics," IEEE Transactions on Vehicular Technology, 50, 3, May 2001 ,p p. 845-853.
    • (2001) IEEE Transactions on Vehicular Technology , vol.50 , Issue.3 , pp. 845-853
    • Ogawa, K.1    Matsuyoshi, T.2    Monma, K.3
  • 24
    • 77957577897 scopus 로고    scopus 로고
    • http://www.3gpp.orgiftp/tsgJan/WG4-RadioITSGR4-45/Report/
  • 26
    • 34547323517 scopus 로고    scopus 로고
    • Tissue equivalent material for H and phantoms
    • C. Gabriel, "Tissue Equivalent Material for H and Phantoms," Phys. Med. Bioi., 52, 2007, pp. 4205-4210.
    • (2007) Phys. Med. Bioi. , vol.52 , pp. 4205-4210
    • Gabriel, C.1
  • 27
    • 39049118635 scopus 로고    scopus 로고
    • Recommended practice for determining the peak spatial-average specific absorption rate (SAR) in the human body due to wireless communications devices: Experimental techniques
    • IEEE
    • IEEE, "Recommended Practice for Determining the Peak Spatial-Average Specific Absorption Rate (SAR) in the Human Body Due to WirelesS CommunicationS DeviceS: Experimental Techniques," IEEE Standard 1528, 2003.
    • (2003) IEEE Standard , vol.1528


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.