Volumn 10, Issue 8, 2010, Pages 7789-7802

Acute response in vivo of a fiber-optic sensor for continuous glucose monitoring from canine studies on point accuracy

Author keywords

Calibration; Clarke error grid analysis; Fiber optic sensor; In vivo glucose monitoring; Point accuracy

Indexed keywords

CONTINUOUS GLUCOSE MONITORING; CONVENTIONAL SYSTEMS; ERROR GRID ANALYSIS; GLUCOSE CONCENTRATION; GLUCOSE MONITORING; LINEAR CORRELATION; PEARSON CORRELATION COEFFICIENTS; POINT ACCURACY;

EID: 77957238796     PISSN: 14248220     EISSN: None     Source Type: Journal    
DOI: 10.3390/s100807789     Document Type: Article
Times cited : (11)

References (26)
  • 1
    • 0027411735 scopus 로고
    • In vivo glucose monitoring: Sense and sensorobility
    • Pickup, J.C. In vivo glucose monitoring: Sense and sensorobility. Diabetes Care 1993, 16, 535-539.
    • (1993) Diabetes Care , vol.16 , pp. 535-539
    • Pickup, J.C.1
  • 2
    • 4243577388 scopus 로고
    • Diabetes and glucose sensors
    • Wilson, G.S.; Reach, G. Diabetes and glucose sensors. Anal. Chem. 1992, 64, 381A-384A.
    • (1992) Anal. Chem , vol.64
    • Wilson, G.S.1    Reach, G.2
  • 3
    • 0027370108 scopus 로고
    • The effect of intensive treatment of diabetes on the development and progression of long-term complications in insulin-dependent diabetes mellitus
    • Diabetes Control and Complication Trials Research Group
    • Diabetes Control and Complication Trials Research Group. The effect of intensive treatment of diabetes on the development and progression of long-term complications in insulin-dependent diabetes mellitus. N. Engl. J. Med. 1993, 329, 977-986.
    • (1993) N. Engl. J. Med , vol.329 , pp. 977-986
  • 4
    • 0032511583 scopus 로고    scopus 로고
    • Intensive blood-glucose control with sulphonylureas or insulin compared with conventional treatment and risk of complications in patients with type 2 diabetes
    • UK Prospective Diabetes Study Group(UKPDS 33)
    • UK Prospective Diabetes Study Group(UKPDS 33). Intensive blood-glucose control with sulphonylureas or insulin compared with conventional treatment and risk of complications in patients with type 2 diabetes. Lancet 1998, 352, 837-853.
    • (1998) Lancet , vol.352 , pp. 837-853
  • 5
    • 33746629303 scopus 로고    scopus 로고
    • A critical appraisal of the continuous error grid analysis
    • Wentholt, I.; Hoekstra, J.; DeVries, J. A critical appraisal of the continuous error grid analysis. Diabetes Care 2006, 29, 1805-1811.
    • (2006) Diabetes Care , vol.29 , pp. 1805-1811
    • Wentholt, I.1    Hoekstra, J.2    DeVries, J.3
  • 6
    • 1642452596 scopus 로고    scopus 로고
    • Close-loop insulin delivery-The path to physiological glucose control
    • Steil, G.M.; Panteleon, A.E.; Rebrin, K. Close-loop insulin delivery-The path to physiological glucose control. Advan. Drug Delivery Rev. 2004, 56, 125-144.
    • (2004) Advan. Drug Delivery Rev , vol.56 , pp. 125-144
    • Steil, G.M.1    Panteleon, A.E.2    Rebrin, K.3
  • 7
    • 27644587693 scopus 로고    scopus 로고
    • The original Clarke error grid analysis (EGA)
    • Clarke, W.L. The original Clarke error grid analysis (EGA). Diabetes Technol. Ther. 2005, 7, 776-779.
    • (2005) Diabetes Technol. Ther , vol.7 , pp. 776-779
    • Clarke, W.L.1
  • 9
    • 0347624612 scopus 로고    scopus 로고
    • Modeling β-cell secretion-Implications for closed-loop glucose homeostasis
    • Steil, G.M.; Rebrin, K.; Janowski, R.; Darwin, C.; Saad, M.F. Modeling β-cell secretion-Implications for closed-loop glucose homeostasis. Diabetes Technol. Ther. 2003, 5, 953-964.
    • (2003) Diabetes Technol. Ther , vol.5 , pp. 953-964
    • Steil, G.M.1    Rebrin, K.2    Janowski, R.3    Darwin, C.4    Saad, M.F.5
  • 12
    • 33644875792 scopus 로고    scopus 로고
    • Improvement in glycemic excursions with a transcutaneous, real-time continuous glucose sensor: A randomized controlled trial
    • Garg, S.; Zisser, H.; Schwartz, S.; Bailey, T.; Kaplan, R.; Ellis, S.; Jovanovic, L. Improvement in glycemic excursions with a transcutaneous, real-time continuous glucose sensor: A randomized controlled trial. Diabetes Care 2006, 29, 44-50.
    • (2006) Diabetes Care , vol.29 , pp. 44-50
    • Garg, S.1    Zisser, H.2    Schwartz, S.3    Bailey, T.4    Kaplan, R.5    Ellis, S.6    Jovanovic, L.7
  • 13
    • 0032882086 scopus 로고    scopus 로고
    • Correlation of fingerstick blood glucose measurements with GlucoWatch biographer glucose result in young subjects with type 1 diabetes
    • Garg, S.K.; Potts, R.O.; Ackerman, N.R.; Fermi, S.J.; Tamada, J.A.; Chase, H.P. Correlation of fingerstick blood glucose measurements with GlucoWatch biographer glucose result in young subjects with type 1 diabetes. Diabetes Care 1999, 130, 1708-1714.
    • (1999) Diabetes Care , vol.130 , pp. 1708-1714
    • Garg, S.K.1    Potts, R.O.2    Ackerman, N.R.3    Fermi, S.J.4    Tamada, J.A.5    Chase, H.P.6
  • 14
    • 0031914389 scopus 로고    scopus 로고
    • Enhanced, simplified glucose sensors: Long-term clinical application of wearable artificial endocrine pancreas
    • Shichri, M.; Sakakida, M.; Nishida, K.; Shioda, S. Enhanced, simplified glucose sensors: Long-term clinical application of wearable artificial endocrine pancreas. Artific. Organ. 1998, 22, 32-42.
    • (1998) Artific. Organ , vol.22 , pp. 32-42
    • Shichri, M.1    Sakakida, M.2    Nishida, K.3    Shioda, S.4
  • 16
    • 0242300559 scopus 로고    scopus 로고
    • Timing of changes in interstitial and venous blood glucose measured with a continuous subcutaneous glucose sensor
    • Boyne, M.S.; Silver, D.M.; Kaplan, J.; Saudek, C.D. Timing of changes in interstitial and venous blood glucose measured with a continuous subcutaneous glucose sensor. Diabetes 2003, 52, 2790-2794.
    • (2003) Diabetes , vol.52 , pp. 2790-2794
    • Boyne, M.S.1    Silver, D.M.2    Kaplan, J.3    Saudek, C.D.4
  • 17
    • 0034004142 scopus 로고    scopus 로고
    • Interstitial glucose concentration and glycemia: Implications for continuous subcutaneous glucose monitoring
    • Aussedat, B.; Dupire-Angel, M.; Gifford, R.; Klein, J.C.; Wilson, G.S.; Reach, G. Interstitial glucose concentration and glycemia: Implications for continuous subcutaneous glucose monitoring. Amer. J. Physiol-Endocr. Metab. 2000, 278, E716-728.
    • (2000) Amer J. Physiol-Endocr. Metab , vol.278 , pp. 716-728
    • Aussedat, B.1    Dupire-Angel, M.2    Gifford, R.3    Klein, J.C.4    Wilson, G.S.5    Reach, G.6
  • 18
    • 0043025558 scopus 로고    scopus 로고
    • Physiological differences between interstitial glucose and blood glucose measured in human subjects
    • Kulcu, E.; Potts, R.O.; Tamada, J.A.; Lesho, M.J.; Reach, G. Physiological differences between interstitial glucose and blood glucose measured in human subjects. Diabetes Care 2003, 26, 2405-2409.
    • (2003) Diabetes Care , vol.26
    • Kulcu, E.1    Potts, R.O.2    Tamada, J.A.3    Lesho, M.J.4    Reach, G.5
  • 19
    • 0033759474 scopus 로고    scopus 로고
    • Can interstitial glucose assessment replace blood glucose measurement?
    • Rebrin, K.; Steil, G.M. Can interstitial glucose assessment replace blood glucose measurement? Diabetes Technol. Ther. 2000, 2, 461-471.
    • (2000) Diabetes Technol. Ther , vol.2 , pp. 461-471
    • Rebrin, K.1    Steil, G.M.2
  • 20
    • 0032836714 scopus 로고    scopus 로고
    • Subcutaneous glucose predicts plasma glucose independent of insulin: Implications for continuous monitoring
    • Rebrin, K.; Steil, G.M.; van Antwerp, W.P.; Mastrototaro, J.J. Subcutaneous glucose predicts plasma glucose independent of insulin: Implications for continuous monitoring. Am. J. Physiol-Endocrinol. Metab. 1999, 277, E561-E571.
    • (1999) Am. J. Physiol-Endocrinol. Metab , vol.277
    • Rebrin, K.1    Steil, G.M.2    van Antwerp, W.P.3    Mastrototaro, J.J.4
  • 21
    • 0037712895 scopus 로고    scopus 로고
    • The role of the independent variable to glucose sensor calibration
    • Panteleon, A.E.; Rebrin, K.; Steil, G.M. The role of the independent variable to glucose sensor calibration. Diabetes Technol. Ther. 2003, 5, 401-410.
    • (2003) Diabetes Technol. Ther , vol.5 , pp. 401-410
    • Panteleon, A.E.1    Rebrin, K.2    Steil, G.M.3
  • 22
    • 77957227058 scopus 로고    scopus 로고
    • The propagation of light
    • 4th ed.; Addison Wesley: San Francisco, CA, USA
    • Hecht, E. The propagation of light. In Optics, 4th ed.; Addison Wesley: San Francisco, CA, USA, 2002; pp. 86-148.
    • (2002) Optics , pp. 86-148
    • Hecht, E.1
  • 23
    • 0028835619 scopus 로고
    • Neutrophil-mediated degradation of segmented polyurethanes
    • Labow, R.S.; Erfle, D.J.; Santerre, J.P. Neutrophil-mediated degradation of segmented polyurethanes. Biomaterials 1995, 16, 51-59.
    • (1995) Biomaterials , vol.16 , pp. 51-59
    • Labow, R.S.1    Erfle, D.J.2    Santerre, J.P.3
  • 25
    • 77950026778 scopus 로고    scopus 로고
    • Critical role of tissue mast cells in controlling long-term glucose sensor function in vivo
    • Klueh, U.; Kaur, M.; Qiao, Y.; Kreutzer, D.L. Critical role of tissue mast cells in controlling long-term glucose sensor function in vivo. Biomaterials 2010, 31, 4540-4551.
    • (2010) Biomaterials , vol.31 , pp. 4540-4551
    • Klueh, U.1    Kaur, M.2    Qiao, Y.3    Kreutzer, D.L.4
  • 26
    • 0041666413 scopus 로고    scopus 로고
    • Clinical performance of CGMS in type 1 diabetic patients treated by continuous subcutaneous insulin infusion using insulin analog
    • Guerci, B.; Benichu, M.; Floriot, M.; Jellimann, S.; Bohme, P.; Drouin, P.; Durain, D. Clinical performance of CGMS in type 1 diabetic patients treated by continuous subcutaneous insulin infusion using insulin analog. Diabetes Care 2003, 26, 582-589.
    • (2003) Diabetes Care , vol.26 , pp. 582-589
    • Guerci, B.1    Benichu, M.2    Floriot, M.3    Jellimann, S.4    Bohme, P.5    Drouin, P.6    Durain, D.7


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.