메뉴 건너뛰기




Volumn 56, Issue 4, 2010, Pages 389-391

Editorial: Noninvasive measurement of carboxyhemoglobin: How accurate is accurate enough?

Author keywords

[No Author keywords available]

Indexed keywords

CARBOXYHEMOGLOBIN;

EID: 77957156897     PISSN: 01960644     EISSN: 10976760     Source Type: Journal    
DOI: 10.1016/j.annemergmed.2010.05.025     Document Type: Editorial
Times cited : (24)

References (17)
  • 1
    • 13744255919 scopus 로고    scopus 로고
    • Unintentional non-fire-related carbon monoxide exposuresUnited States, 2001-2003
    • Centers for Disease Control and Prevention
    • Centers for Disease Control and Prevention Unintentional non-fire-related carbon monoxide exposuresUnited States, 2001-2003 MMWR Morb Mortal Wkly Rep 54 2005 36 39
    • (2005) MMWR Morb Mortal Wkly Rep , vol.54 , pp. 36-39
  • 2
    • 0032569830 scopus 로고    scopus 로고
    • Carbon monoxide poisoning
    • A. Ernst, and J.D. Zibrak Carbon monoxide poisoning N Engl J Med 339 1998 1603 1608
    • (1998) N Engl J Med , vol.339 , pp. 1603-1608
    • Ernst, A.1    Zibrak, J.D.2
  • 3
    • 0032948708 scopus 로고    scopus 로고
    • Carbon monoxide poisoning: A review for clinicians
    • J. Varon, P.E. Marik, and R.E. Fromm Jr Carbon monoxide poisoning: a review for clinicians J Emerg Med 17 1999 87 93
    • (1999) J Emerg Med , vol.17 , pp. 87-93
    • Varon, J.1    Marik, P.E.2
  • 4
    • 77957111247 scopus 로고    scopus 로고
    • Masimo Corporation
    • Masimo Corporation Masimo Rad-57 http://www.masimo.com/rad-57/index.htm Accessed April 28, 2010
    • Masimo Rad-57
  • 6
    • 77957142569 scopus 로고    scopus 로고
    • Masimo Corporation. Carboxyhemoglobin
    • Masimo Corporation. Carboxyhemoglobin http://www.masimo.com/spco/ accuracy.htm Accessed April 28, 2010
  • 7
    • 77957121021 scopus 로고    scopus 로고
    • Performance of the RAD-57 pulse CO-oximeter compared to standard laboratory carboxyhemoglobin measurement
    • M. Touger, A. Birnbaum, and J. Wang Performance of the RAD-57 pulse CO-oximeter compared to standard laboratory carboxyhemoglobin measurement Ann Emerg Med 56 2010 382 388
    • (2010) Ann Emerg Med , vol.56 , pp. 382-388
    • Touger, M.1    Birnbaum, A.2    Wang, J.3
  • 8
    • 45849102755 scopus 로고    scopus 로고
    • Comparison of the Masimo Rad-57 pulse oximeter with SpCO technology against a laboratory CO-oximeter using arterial blood
    • C. Mottram, L.J. Hanson, and P.D. Scanlon Comparison of the Masimo Rad-57 pulse oximeter with SpCO technology against a laboratory CO-oximeter using arterial blood Respir Care 50 2005 1471
    • (2005) Respir Care , vol.50 , pp. 1471
    • Mottram, C.1    Hanson, L.J.2    Scanlon, P.D.3
  • 9
    • 33750446315 scopus 로고    scopus 로고
    • Measurement of carboxyhemoglobin and methemoglobin by pulse oximetry: A human volunteer study
    • S.J. Barker, J. Curry, and D. Redford Measurement of carboxyhemoglobin and methemoglobin by pulse oximetry: a human volunteer study Anesthesiology 105 2006 892 897
    • (2006) Anesthesiology , vol.105 , pp. 892-897
    • Barker, S.J.1    Curry, J.2    Redford, D.3
  • 10
    • 42749085776 scopus 로고    scopus 로고
    • Noninvasive pulse co-oximetry screening in the Emergency Department identifies occult carbon monoxide toxicity
    • S. Suner, R. Partridge, and A. Sucov Noninvasive pulse co-oximetry screening in the Emergency Department identifies occult carbon monoxide toxicity J Emerg Med 34 2009 441 450
    • (2009) J Emerg Med , vol.34 , pp. 441-450
    • Suner, S.1    Partridge, R.2    Sucov, A.3
  • 11
    • 38449099273 scopus 로고    scopus 로고
    • Detecting CO - FDNY studies prehospital assessment of COHb
    • D. Ben-Eli, J. Peruggia, and J. McFarland Detecting CO - FDNY studies prehospital assessment of COHb JEMS 2007 36 37
    • (2007) JEMS , pp. 36-37
    • Ben-Eli, D.1    Peruggia, J.2    McFarland, J.3
  • 12
    • 77957155539 scopus 로고    scopus 로고
    • Siemens Rapidlab 1200 series and Rapidpoint 405 critical care analysers standard operating procedure (version 2.00)
    • Siemens Rapidlab 1200 series and Rapidpoint 405 critical care analysers standard operating procedure (version 2.00) http://217.16.54.49/jps/gas-sop.pdf Accessed April 27, 2010.
  • 13
    • 77950515463 scopus 로고    scopus 로고
    • Modernizing device regulation
    • A.M. Garber Modernizing device regulation N Engl J Med 362 2010 1161 1163
    • (2010) N Engl J Med , vol.362 , pp. 1161-1163
    • Garber, A.M.1
  • 14
    • 73949084847 scopus 로고    scopus 로고
    • Strength of study evidence examined by the FDA in premarket approval of cardiovascular devices
    • S.S. Dhruva, L.A. Bero, and R.F. Redberg Strength of study evidence examined by the FDA in premarket approval of cardiovascular devices JAMA 302 2009 2679 2685
    • (2009) JAMA , vol.302 , pp. 2679-2685
    • Dhruva, S.S.1    Bero, L.A.2    Redberg, R.F.3
  • 15
    • 76149099323 scopus 로고    scopus 로고
    • Premarket clinical evaluation of novel cardiovascular devices: Quality analysis of premarket clinical studies submitted to FDA 2000-2007
    • D.B. Kramer, E. Mallis, and B.D. Zuckerman Premarket clinical evaluation of novel cardiovascular devices: quality analysis of premarket clinical studies submitted to FDA 2000-2007 Am J Ther 17 2010 2 7
    • (2010) Am J Ther , vol.17 , pp. 2-7
    • Kramer, D.B.1    Mallis, E.2    Zuckerman, B.D.3
  • 16
    • 77957168625 scopus 로고    scopus 로고
    • FDA: Institute of Medicine to study premarket clearance process for medical devices
    • FDA: Institute of Medicine to study premarket clearance process for medical devices http://www.fda.gov/NewsEvents/Newsroom/PressAnnouncements/2009/ ucm183497.htm Accessed May 18, 2010


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.