메뉴 건너뛰기




Volumn 56, Issue 4, 2010, Pages 382-388

Performance of the RAD-57 pulse Co-oximeter compared with standard laboratory carboxyhemoglobin measurement

Author keywords

[No Author keywords available]

Indexed keywords

CARBOXYHEMOGLOBIN;

EID: 77957121021     PISSN: 01960644     EISSN: 10976760     Source Type: Journal    
DOI: 10.1016/j.annemergmed.2010.03.041     Document Type: Article
Times cited : (69)

References (15)
  • 1
    • 77957118184 scopus 로고    scopus 로고
    • Carbon monoxide
    • C. Tomaszewski Carbon monoxide L.R. Goldfrank, N.E. Flomenbaum, N.A. Lewin, Goldfrank's Toxicologic Emergencies 8th ed. 2006 McGraw-Hill Co New York, NY 1689 1704
    • (2006) Goldfrank's Toxicologic Emergencies , pp. 1689-1704
    • Tomaszewski, C.1
  • 2
    • 0028956245 scopus 로고
    • Relationship between venous and arterial carboxyhemoglobin levels in patients with suspected carbon monoxide poisoning
    • M. Touger, E.J. Gallagher, and J. Tyrell Relationship between venous and arterial carboxyhemoglobin levels in patients with suspected carbon monoxide poisoning Ann Emerg Med. 25 1995 481 483
    • (1995) Ann Emerg Med. , vol.25 , pp. 481-483
    • Touger, M.1    Gallagher, E.J.2    Tyrell, J.3
  • 3
    • 67449108639 scopus 로고    scopus 로고
    • Masimo Rad-57 pulse co-oximeter for noninvasive carboxyhemoglobin measurement
    • S. Suner, and J. McMurdy Masimo Rad-57 pulse co-oximeter for noninvasive carboxyhemoglobin measurement Expert Rev Med Devices 6 2009 125 130
    • (2009) Expert Rev Med Devices , vol.6 , pp. 125-130
    • Suner, S.1    McMurdy, J.2
  • 6
    • 79958768914 scopus 로고    scopus 로고
    • Victim of carbon monoxide poisoning identified by carbon monoxide oximetry
    • doi: 10.1016/jemermed.2009.05.017
    • Roth D, Hubmann N, Navel C, et al. Victim of carbon monoxide poisoning identified by carbon monoxide oximetry. J Emerg Med. doi: 10.1016/jemermed.2009. 05.017.
    • J Emerg Med
    • Roth, D.1    Hubmann, N.2    Navel, C.3
  • 7
    • 45849084667 scopus 로고    scopus 로고
    • Finding needles in a haystack: A case series of carbon monoxide poisoning detected using new technology in the emergency department
    • K.J. Chee, D. Nilson, and R. Partridge Finding needles in a haystack: a case series of carbon monoxide poisoning detected using new technology in the emergency department Clin Toxicol. 46 2008 461 469
    • (2008) Clin Toxicol. , vol.46 , pp. 461-469
    • Chee, K.J.1    Nilson, D.2    Partridge, R.3
  • 8
    • 42749085776 scopus 로고    scopus 로고
    • Non-invasive pulse CO-oximetry screening in the emergency department identifies occult carbon monoxide toxicity
    • S. Suner, R. Partridge, and A. Sucov Non-invasive pulse CO-oximetry screening in the emergency department identifies occult carbon monoxide toxicity J Emerg Med. 34 2008 441 450
    • (2008) J Emerg Med. , vol.34 , pp. 441-450
    • Suner, S.1    Partridge, R.2    Sucov, A.3
  • 9
    • 33748772801 scopus 로고    scopus 로고
    • Non-invasive carbon monoxide measurement is not accurate
    • G.F. O'Malley Non-invasive carbon monoxide measurement is not accurate Ann Emerg Med. 48 2006 477
    • (2006) Ann Emerg Med. , vol.48 , pp. 477
    • O'Malley, G.F.1
  • 10
    • 33750446315 scopus 로고    scopus 로고
    • Measurement of carboxyhemoglobin and methemoglobin by pulse oximetry
    • S.J. Barker, J. Curry, and D. Redford Measurement of carboxyhemoglobin and methemoglobin by pulse oximetry Anesthesiology 105 2006 892 897
    • (2006) Anesthesiology , vol.105 , pp. 892-897
    • Barker, S.J.1    Curry, J.2    Redford, D.3
  • 11
    • 44949184535 scopus 로고    scopus 로고
    • Reliability of new pulse CO-oximeter in victims of carbon monoxide poisoning
    • M. Coulange, A. Barthelemy, and F. Hug Reliability of new pulse CO-oximeter in victims of carbon monoxide poisoning Undersea Hyperb Med. 35 2008 107 111
    • (2008) Undersea Hyperb Med. , vol.35 , pp. 107-111
    • Coulange, M.1    Barthelemy, A.2    Hug, F.3
  • 12
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • J.M. Bland, and D.G. Altman Statistical methods for assessing agreement between two methods of clinical measurement Lancet 1 1986 307 310
    • (1986) Lancet , vol.1 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 13
    • 38449099273 scopus 로고    scopus 로고
    • Detecting CO. FDNY studies prehospital assessment of COHb
    • D. Ben-Eli, J. Peruggia, and J. McFarland Detecting CO. FDNY studies prehospital assessment of COHb JEMS 32 2007 S36 S37
    • (2007) JEMS , vol.32
    • Ben-Eli, D.1    Peruggia, J.2    McFarland, J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.