메뉴 건너뛰기




Volumn 40, Issue 6, 2011, Pages 640-642

Victim of carbon monoxide poisoning identified by carbon monoxide oximetry

Author keywords

blood gas monitoring; carbon monoxide poisoning; pulse oximetry; transcutaneous; triage

Indexed keywords

CARBOXYHEMOGLOBIN;

EID: 79958768914     PISSN: 07364679     EISSN: 07364679     Source Type: Journal    
DOI: 10.1016/j.jemermed.2009.05.017     Document Type: Article
Times cited : (13)

References (6)
  • 1
    • 13744255919 scopus 로고    scopus 로고
    • Unintentional non-fire-related carbon monoxide exposures - United States, 2001-2003
    • Centers for Disease Control and Prevention (CDC)
    • Centers for Disease Control and Prevention (CDC). Unintentional non-fire-related carbon monoxide exposures - United States, 2001-2003. MMWR Morb Mortal Wkly Rep 2005;54:36-9.
    • (2005) MMWR Morb Mortal Wkly Rep , vol.54 , pp. 36-39
  • 2
    • 33750446315 scopus 로고    scopus 로고
    • Measurement of carboxyhemoglobin and methemoglobin by pulse oximetry: A human volunteer study
    • DOI 10.1097/00000542-200611000-00008, PII 0000054220061100000008
    • Barker SJ, Curry J, Redford D, Morgan S. Measurement of carboxyhemoglobin and methemoglobin by pulse oximetry: a human volunteer study. Anesthesiology 2006;105:892-7. (Pubitemid 44655498)
    • (2006) Anesthesiology , vol.105 , Issue.5 , pp. 892-897
    • Barker, S.J.1    Curry, J.2    Redford, D.3    Morgan, S.4
  • 3
    • 33750880122 scopus 로고    scopus 로고
    • Use of a noninvasive pulse CO-oximeter to measure blood carboxyhemoglobin levels in bingo players
    • Hampson NB, Scott KL. Use of a noninvasive pulse CO-oximeter to measure blood carboxyhemoglobin levels in bingo players. Respir Care 2006;51:758-60. (Pubitemid 47109298)
    • (2006) Respiratory Care , vol.51 , Issue.7 , pp. 758-760
    • Hampson, N.B.1    Ecker, E.D.2    Scott, K.L.3
  • 5
    • 43149099218 scopus 로고    scopus 로고
    • Carbon monoxide poisoning: How many patients do we miss?
    • Keles A, Demircan A, Kurtoglu G. Carbon monoxide poisoning: how many patients do we miss? Eur J Emerg Med 2008;15:154-7.
    • (2008) Eur J Emerg Med , vol.15 , pp. 154-157
    • Keles, A.1    Demircan, A.2    Kurtoglu, G.3
  • 6
    • 56849093676 scopus 로고    scopus 로고
    • The measurement of dyshemoglobins and total hemoglobin by pulse oximetry
    • Barker SJ, Badal JJ. The measurement of dyshemoglobins and total hemoglobin by pulse oximetry. Curr Opin Anaesthesiol 2008;21: 805-10.
    • (2008) Curr Opin Anaesthesiol , vol.21 , pp. 805-810
    • Barker, S.J.1    Badal, J.J.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.