메뉴 건너뛰기




Volumn 97, Issue 12, 2010, Pages

Nanomechanical biosensing with immunomagnetic separation

Author keywords

[No Author keywords available]

Indexed keywords

BIOSENSING; CANTILEVER DEFLECTION; CANTILEVER STRUCTURES; CANTILEVER SYSTEMS; COMPLEX MIXTURE; FUNCTIONALIZED; IMMUNOMAGNETIC SEPARATION; MAGNETIC BEADS; MAGNETIC FORCE; OSCILLATING MAGNETIC FIELDS; SENSING ARM; STREPTAVIDIN;

EID: 77957105545     PISSN: 00036951     EISSN: None     Source Type: Journal    
DOI: 10.1063/1.3489356     Document Type: Article
Times cited : (17)

References (16)
  • 4
    • 2642579896 scopus 로고    scopus 로고
    • Micromechanical detection of proteins using aptamer-based receptor molecules
    • DOI 10.1021/ac049859f
    • C. A. Savran, S. M. Knudsen, A. D. Ellington, and S. R. Manalis, Anal. Chem. ANCHAM 0003-2700 76, 3194 (2004). 10.1021/ac049859f (Pubitemid 38715714)
    • (2004) Analytical Chemistry , vol.76 , Issue.11 , pp. 3194-3198
    • Savran, C.A.1    Knudsen, S.M.2    Ellington, A.D.3    Manalis, S.R.4
  • 6
    • 1842788500 scopus 로고    scopus 로고
    • APPLAB 0003-6951,. 10.1063/1.1667011
    • A. Gupta, D. Akin, and R. Bashir, Appl. Phys. Lett. APPLAB 0003-6951 84, 1976 (2004). 10.1063/1.1667011
    • (2004) Appl. Phys. Lett. , vol.84 , pp. 1976
    • Gupta, A.1    Akin, D.2    Bashir, R.3
  • 8
    • 67650672138 scopus 로고    scopus 로고
    • TRBIDM 0167-7799,. 10.1016/j.tibtech.2009.04.003
    • J. Corchero and A. Villaverde, Trends Biotechnol. TRBIDM 0167-7799 27, 468 (2009). 10.1016/j.tibtech.2009.04.003
    • (2009) Trends Biotechnol. , vol.27 , pp. 468
    • Corchero, J.1    Villaverde, A.2
  • 11
    • 32044455323 scopus 로고    scopus 로고
    • A fluorophore-based bio-barcode amplification assay for proteins
    • DOI 10.1002/smll.200500260
    • B. K. Oh, J. M. Nam, S. W. Lee, and C. A. Mirkin, Small SMALBC 1613-6810 2, 103 (2006). 10.1002/smll.200500260 (Pubitemid 43198003)
    • (2006) Small , vol.2 , Issue.1 , pp. 103-108
    • Oh, B.-K.1    Nam, J.-M.2    Lee, S.W.3    Mirkin, C.A.4
  • 14
    • 77957113007 scopus 로고    scopus 로고
    • See supplementary material at E-APPLAB-97-067037 for an analytical expression of the minimum number of detectable beads and for the details of the microfabrication process.
    • See supplementary material at http://dx.doi.org/10.1063/1.3489356 E-APPLAB-97-067037 for an analytical expression of the minimum number of detectable beads and for the details of the microfabrication process.
  • 15
    • 34250730234 scopus 로고    scopus 로고
    • In situ assembled diffraction grating for biomolecular detection
    • DOI 10.1063/1.2746409
    • C. L. Chang, G. Acharya, and C. A. Savran, Appl. Phys. Lett. APPLAB 0003-6951 90, 233901 (2007). 10.1063/1.2746409 (Pubitemid 46960342)
    • (2007) Applied Physics Letters , vol.90 , Issue.23 , pp. 233901
    • Chang, C.-L.1    Acharya, G.2    Savran, C.A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.