메뉴 건너뛰기




Volumn 6, Issue SUPPL. G, 2010, Pages

Imaging decision-making for transfemoral or transapical approach of transcatheter aortic valve implantation

Author keywords

Aortic annulus; Aortic root; Aorto iliac angiography; Calcification; Complications; CT angiography; Imaging; Preprocedural evaluation; Tortuosity; Transapical; Transcatheter aortic valve implantation; Transfemoral

Indexed keywords

ANGIOGRAPHY; AORTA ROOT; AORTA STENOSIS; AORTA VALVE REPLACEMENT; ARTERY CALCIFICATION; ARTERY DIAMETER; CLINICAL DECISION MAKING; COMPUTER ASSISTED TOMOGRAPHY; FEMORAL ARTERY; HUMAN; IMAGE RECONSTRUCTION; INVASIVE PROCEDURE; NUCLEAR MAGNETIC RESONANCE IMAGING; PATIENT SELECTION; PROGNOSIS; QUALITY OF LIFE; REVIEW; TRANSAPICAL APPROACH; TRANSCATHETER AORTIC VALVE IMPLANTATION; TRANSESOPHAGEAL ECHOCARDIOGRAPHY; TRANSFEMORAL APPROACH; TRANSTHORACIC ECHOCARDIOGRAPHY; VASCULAR ACCESS; AORTA VALVE; DIAGNOSTIC IMAGING; ECHOGRAPHY; HEART CATHETERIZATION; HEART VALVE PROSTHESIS; HEART VALVE REPLACEMENT; INSTRUMENTATION; METHODOLOGY; PREDICTION AND FORECASTING; RADIAL ARTERY; RADIOGRAPHY; TREATMENT OUTCOME; VALVULAR HEART DISEASE;

EID: 77957056605     PISSN: 1774024X     EISSN: 19696213     Source Type: Journal    
DOI: None     Document Type: Review
Times cited : (15)

References (33)
  • 1
    • 0037058854 scopus 로고    scopus 로고
    • Percutaneous transcatheter implantation of an aortic valve prosthesis for calcific aortic stenosis: First human case description
    • DOI 10.1161/01.CIR.0000047200.36165.B8
    • Cribier A, Eltchaninoff H, Bash A, Borenstein N, Tron C, Bauer F, Derumeaux G, Anselme F, Laborde F, Leon MB. Percutaneous transcatheter implantation of an aortic valve prosthesis for calcific aortic stenosis: first human case description. Circulation. 2002;106:3006-3008. (Pubitemid 35440280)
    • (2002) Circulation , vol.106 , Issue.24 , pp. 3006-3008
    • Cribier, A.1    Eltchaninoff, H.2    Bash, A.3    Borenstein, N.4    Tron, C.5    Bauer, F.6    Derumeaux, G.7    Anselme, F.8    Laborde, F.9    Leon, M.B.10
  • 2
    • 55849132881 scopus 로고    scopus 로고
    • Procedural and 30-day outcomes following transcatheter aortic valve implantation using the third generation (18 Fr) corevalve revalving system: Results from the multicentre, expanded evaluation registry 1-year following CE mark approval
    • Piazza N, Grube E, Gerckens U, den Heijer P, Linke A, Luha O, Ramondo A, Ussia G, Wenaweser P, Windecker S, et al. Procedural and 30-day outcomes following transcatheter aortic valve implantation using the third generation (18 Fr) corevalve revalving system: results from the multicentre, expanded evaluation registry 1-year following CE mark approval. EuroIntervention. 2008;4:242-249.
    • (2008) EuroIntervention , vol.4 , pp. 242-249
    • Piazza, N.1    Grube, E.2    Gerckens, U.3    Den Heijer, P.4    Linke, A.5    Luha, O.6    Ramondo, A.7    Ussia, G.8    Wenaweser, P.9    Windecker, S.10
  • 5
    • 65149095001 scopus 로고    scopus 로고
    • Outcomes and safety of percutaneous aortic valve replacement
    • Zajarias A, Cribier AG. Outcomes and safety of percutaneous aortic valve replacement. J Am Coll Cardiol. 2009;53:1829-1836.
    • (2009) J Am Coll Cardiol , vol.53 , pp. 1829-1836
    • Zajarias, A.1    Cribier, A.G.2
  • 9
    • 21044456170 scopus 로고    scopus 로고
    • The clinical development of percutaneous heart valve technology: A position statement of the Society of Thoracic Surgeons (STS), the American Association for Thoracic Surgery (AATS), and the Society for Cardiovascular Angiography and Interventions (SCAI) Endorsed by the American College of Cardiology Foundation (ACCF) and the American Heart Association (AHA)
    • Vassiliades TA, Jr., Block PC, Cohn LH, Adams DH, Borer JS, Feldman T, Holmes DR, Laskey WK, Lytle BW, Mack MJ, et al. The clinical development of percutaneous heart valve technology: a position statement of the Society of Thoracic Surgeons (STS), the American Association for Thoracic Surgery (AATS), and the Society for Cardiovascular Angiography and Interventions (SCAI) Endorsed by the American College of Cardiology Foundation (ACCF) and the American Heart Association (AHA). J Am Coll Cardiol. 2005;45:1554-1560.
    • (2005) J Am Coll Cardiol , vol.45 , pp. 1554-1560
    • Vassiliades Jr., T.A.1    Block, P.C.2    Cohn, L.H.3    Adams, D.H.4    Borer, J.S.5    Feldman, T.6    Holmes, D.R.7    Laskey, W.K.8    Lytle, B.W.9    Mack, M.J.10
  • 11
    • 75349102866 scopus 로고    scopus 로고
    • Adherence to patient selection criteria in patients undergoing transcatheter aortic valve implantation with the 18F CoreValve ReValving System
    • Piazza N, Otten A, Schultz C, Onuma Y, Garcia-Garcia HM, Boersma E, de Jaegere P, Serruys PW. Adherence to patient selection criteria in patients undergoing transcatheter aortic valve implantation with the 18F CoreValve ReValving System. Heart. 2010;96:19-26.
    • (2010) Heart , vol.96 , pp. 19-26
    • Piazza, N.1    Otten, A.2    Schultz, C.3    Onuma, Y.4    Garcia-Garcia, H.M.5    Boersma, E.6    De Jaegere, P.7    Serruys, P.W.8
  • 12
    • 0027465472 scopus 로고
    • Ultrasonic-pathological comparison of the human arterial wall. Verification of intima-media thickness
    • Wong M, Edelstein J, Wollman J, Bond MG. Ultrasonic-pathological comparison of the human arterial wall. Verification of intima-media thickness. Arterioscler Thromb. 1993;13:482-486.
    • (1993) Arterioscler Thromb , vol.13 , pp. 482-486
    • Wong, M.1    Edelstein, J.2    Wollman, J.3    Bond, M.G.4
  • 13
    • 34247369842 scopus 로고    scopus 로고
    • Analysis of agreement between Duplex ultrasound scanning and arteriography in patients with lower limb artery disease
    • DOI 10.2459/01.JCM.0000268124.51543.b2, PII 0124466520070500000006
    • Favaretto E, Pili C, Amato A, Conti E, Losinno F, Rossi C, Faccioli L, Palareti G. Analysis of agreement between Duplex ultrasound scanning and arteriography in patients with lower limb artery disease. J Cardiovasc Med (Hagerstown). 2007;8:337-341. (Pubitemid 46634073)
    • (2007) Journal of Cardiovascular Medicine , vol.8 , Issue.5 , pp. 337-341
    • Favaretto, E.1    Pili, C.2    Amato, A.3    Conti, E.4    Losinno, F.5    Rossi, C.6    Faccioli, L.7    Palareti, G.8
  • 14
    • 77950503224 scopus 로고    scopus 로고
    • Aorto-iliac angiography as a screening tool in selecting patients for transfemoral aortic valve implantation with the Edwards SAPIEN bioprosthesis
    • Eltchaninoff H, Kerkeni M, Zajarias A, Tron C, Godin M, Sanchez Giron C, Baala B, Cribier A. Aorto-iliac angiography as a screening tool in selecting patients for transfemoral aortic valve implantation with the Edwards SAPIEN bioprosthesis. EuroIntervention. 2009;5:438-442.
    • (2009) EuroIntervention , vol.5 , pp. 438-442
    • Eltchaninoff, H.1    Kerkeni, M.2    Zajarias, A.3    Tron, C.4    Godin, M.5    Sanchez Giron, C.6    Baala, B.7    Cribier, A.8
  • 16
    • 35348961526 scopus 로고    scopus 로고
    • Lower extremity arterial disease: Multidetector CT angiography - Meta-analysis
    • DOI 10.1148/radiol.2451061280
    • Heijenbrok-Kal MH, Kock MC, Hunink MG. Lower extremity arterial disease: multidetector CT angiography meta-analysis. Radiology. 2007;245:433-439. (Pubitemid 47612524)
    • (2007) Radiology , vol.245 , Issue.2 , pp. 433-439
    • Heijenbrok-Kal, M.H.1    Kock, M.C.J.M.2    Hunink, M.G.M.3
  • 17
    • 59249106834 scopus 로고    scopus 로고
    • Diagnostic performance of computed tomography angiography in peripheral arterial disease: A systematic review and meta-analysis
    • Met R, Bipat S, Legemate DA, Reekers JA, Koelemay MJ. Diagnostic performance of computed tomography angiography in peripheral arterial disease: a systematic review and meta-analysis. JAMA. 2009;301:415-424.
    • (2009) JAMA , vol.301 , pp. 415-424
    • Met, R.1    Bipat, S.2    Legemate, D.A.3    Reekers, J.A.4    Koelemay, M.J.5
  • 18
    • 33847612005 scopus 로고    scopus 로고
    • Diagnostic accuracy of multislice CT angiography in peripheral arterial disease
    • DOI 10.1097/01.RVI.0000248830.17550.50, PII 0000251820061200000009
    • Sun Z. Diagnostic accuracy of multislice CT angiography in peripheral arterial disease. J Vasc Interv Radiol. 2006;17:1915-1921. (Pubitemid 46360672)
    • (2006) Journal of Vascular and Interventional Radiology , vol.17 , Issue.12 , pp. 1915-1921
    • Sun, Z.1
  • 22
    • 77950501005 scopus 로고    scopus 로고
    • Three dimensional evaluation of the aortic annulus using multislice computer tomography: Are manufacturer's guidelines for sizing for percutaneous aortic valve replacement helpful?
    • Schultz CJ, Moelker A, Piazza N, Tzikas A, Otten A, Nuis RJ, Neefjes LA, van Geuns RJ, de Feyter P, Krestin G, et al. Three dimensional evaluation of the aortic annulus using multislice computer tomography: are manufacturer's guidelines for sizing for percutaneous aortic valve replacement helpful? Eur Heart J. 2009.
    • (2009) Eur Heart J
    • Schultz, C.J.1    Moelker, A.2    Piazza, N.3    Tzikas, A.4    Otten, A.5    Nuis, R.J.6    Neefjes, L.A.7    Van Geuns, R.J.8    De Feyter, P.9    Krestin, G.10
  • 23
    • 8544278000 scopus 로고    scopus 로고
    • Prediction of homograft aortic valve size by transthoracic and transesophageal two dimensional echocardiography
    • Fan CM, Liu X, Panidis JP, Wiener DH, Pollack PS, Addonizio VP. Prediction of Homograft Aortic Valve Size by Transthoracic and Transesophageal Two-Dimensional Echocardiography. Echocardiography. 1997;14:345-348. (Pubitemid 27329745)
    • (1997) Echocardiography , vol.14 , Issue.4 , pp. 345-348
    • Fan, C.M.1    Liu, X.2    Panidis, J.P.3    Wiener, D.H.4    Pollack, P.S.5    Addonizio, V.P.6
  • 25
  • 26
    • 37249075389 scopus 로고    scopus 로고
    • Calcific bicuspid aortic stenosis: A questionable indication for endovascular valve implantation?
    • Zegdi R, Khabbaz Z, Ciobotaru V, Noghin M, Deloche A, Fabiani JN. Calcific bicuspid aortic stenosis: a questionable indication for endovascular valve implantation? Ann Thorac Surg. 2008;85:342.
    • (2008) Ann Thorac Surg , vol.85 , pp. 342
    • Zegdi, R.1    Khabbaz, Z.2    Ciobotaru, V.3    Noghin, M.4    Deloche, A.5    Fabiani, J.N.6
  • 27
    • 76749129375 scopus 로고    scopus 로고
    • Increased radial force improves stent deployment in tricuspid but not in bicuspid stenotic native aortic valves
    • Zegdi R, Lecuyer L, Achouh P, Didier B, Lafont A, Latremouille C, Fabiani JN. Increased radial force improves stent deployment in tricuspid but not in bicuspid stenotic native aortic valves. Ann Thorac Surg. 2010;89:768-772.
    • (2010) Ann Thorac Surg , vol.89 , pp. 768-772
    • Zegdi, R.1    Lecuyer, L.2    Achouh, P.3    Didier, B.4    Lafont, A.5    Latremouille, C.6    Fabiani, J.N.7
  • 29
    • 0141567472 scopus 로고    scopus 로고
    • Three dimensional volume quantification of aortic valve calcification using multislice computed tomography
    • Morgan-Hughes GJ, Owens PE, Roobottom CA, Marshall AJ. Three dimensional volume quantification of aortic valve calcification using multislice computed tomography. Heart. 2003;89:1191-1194. (Pubitemid 37164011)
    • (2003) Heart , vol.89 , Issue.10 , pp. 1191-1194
    • Morgan-Hughes, G.J.1    Owens, P.E.2    Roobottom, C.A.3    Marshall, A.J.4
  • 32
    • 60649119615 scopus 로고    scopus 로고
    • Successful percutaneous coronary intervention after implantation of a CoreValve percutaneous aortic valve
    • Geist V, Sherif MA, Khattab AA. Successful percutaneous coronary intervention after implantation of a CoreValve percutaneous aortic valve. Catheter Cardiovasc Interv. 2009;73:61-67.
    • (2009) Catheter Cardiovasc Interv , vol.73 , pp. 61-67
    • Geist, V.1    Sherif, M.A.2    Khattab, A.A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.