메뉴 건너뛰기




Volumn 36, Issue 3, 2009, Pages 816-820

Static and rotational output variation of a tomotherapy unit

Author keywords

Calibration; Output variation; Tomotherapy

Indexed keywords

CALIBRATION;

EID: 61349101735     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.3075898     Document Type: Article
Times cited : (8)

References (9)
  • 1
    • 0038038964 scopus 로고    scopus 로고
    • Benchmarking beam alignment for a clinical helical tomotherapy device
    • 0094-2405 10.1118/1.1576395.
    • J. Balog, T. R. Mackie, D. Pearson, S. Hui, B. Paliwal, and R. Jeraj, " Benchmarking beam alignment for a clinical helical tomotherapy device.," Med. Phys. 0094-2405 10.1118/1.1576395 30, 1118-1127 (2003).
    • (2003) Med. Phys. , vol.30 , pp. 1118-1127
    • Balog, J.1    MacKie, T.R.2    Pearson, D.3    Hui, S.4    Paliwal, B.5    Jeraj, R.6
  • 2
    • 14644424546 scopus 로고    scopus 로고
    • Dose calibration of non conventional treatment systems applied to helical tomotherapy
    • 0094-2405 10.1118/1.1855015.
    • R. Jeraj, T. R. Mackie, J. Balog, and G. Olivera, " Dose calibration of non conventional treatment systems applied to helical tomotherapy.," Med. Phys. 0094-2405 10.1118/1.1855015 32, 570-577 (2005).
    • (2005) Med. Phys. , vol.32 , pp. 570-577
    • Jeraj, R.1    MacKie, T.R.2    Balog, J.3    Olivera, G.4
  • 3
    • 33749390554 scopus 로고    scopus 로고
    • Helical tomotherapy dynamic quality assurance
    • 0094-2405 10.1118/1.2351952.
    • J. Balog, T. Holmes, and R. Vaden, " Helical tomotherapy dynamic quality assurance.," Med. Phys. 0094-2405 10.1118/1.2351952 33, 3939-3950 (2006).
    • (2006) Med. Phys. , vol.33 , pp. 3939-3950
    • Balog, J.1    Holmes, T.2    Vaden, R.3
  • 4
    • 0032874911 scopus 로고    scopus 로고
    • AAPM American Association of Physicists in Medicine, Task Group 51: Protocol for clinical reference dosimetry of high-energy photon and electron beams
    • 0094-2405 10.1118/1.598691.
    • P. R. Almond, P. J. Biggs, B. M. Coursey, W. F. Hanson, M. S. Huq, R. Nath, and D. W. Rogers, " AAPM American Association of Physicists in Medicine, Task Group 51: Protocol for clinical reference dosimetry of high-energy photon and electron beams.," Med. Phys. 0094-2405 10.1118/1.598691 26, 1847-1870 (1999).
    • (1999) Med. Phys. , vol.26 , pp. 1847-1870
    • Almond, P.R.1    Biggs, P.J.2    Coursey, B.M.3    Hanson, W.F.4    Huq, M.S.5    Nath, R.6    Rogers, D.W.7
  • 6
    • 3142667537 scopus 로고    scopus 로고
    • Technical Note: Output and energy fluctuations of the tomotherapy Hi-Art helical tomotherapy system
    • 0094-2405 10.1118/1.1763007.
    • S. L. Mahan, D. J. Chase, and C. R. Ramsey, " Technical Note: Output and energy fluctuations of the tomotherapy Hi-Art helical tomotherapy system.," Med. Phys. 0094-2405 10.1118/1.1763007 31, 2119-2120 (2004).
    • (2004) Med. Phys. , vol.31 , pp. 2119-2120
    • Mahan, S.L.1    Chase, D.J.2    Ramsey, C.R.3
  • 7
    • 3442881436 scopus 로고    scopus 로고
    • Quality assurance of a helical tomotherapy machine
    • 0031-9155 10.1088/0031-9155/49/13/012.
    • J. D. Fenwick, " Quality assurance of a helical tomotherapy machine.," Phys. Med. Biol. 0031-9155 10.1088/0031-9155/49/13/012 49, 2933-2953 (2004).
    • (2004) Phys. Med. Biol. , vol.49 , pp. 2933-2953
    • Fenwick, J.D.1
  • 8
    • 17144376449 scopus 로고    scopus 로고
    • Modelling simple helically delivered dose distributions
    • 0031-9155 10.1088/0031-9155/50/7/013.
    • J. D. Fenwick, " Modelling simple helically delivered dose distributions.," Phys. Med. Biol. 0031-9155 10.1088/0031-9155/50/7/013 50, 1505-1517 (2005).
    • (2005) Phys. Med. Biol. , vol.50 , pp. 1505-1517
    • Fenwick, J.D.1
  • 9
    • 0011074428 scopus 로고    scopus 로고
    • Central axis depth dose data for use in radiotherapy
    • Joint Working Party of the British Institute of Radiology and the Institution of Physics and Engineering in Medicine and Biology, ","
    • Joint Working Party of the British Institute of Radiology and the Institution of Physics and Engineering in Medicine and Biology, " Central axis depth dose data for use in radiotherapy.," BJR Suppl. 25 (1996).
    • (1996) BJR Suppl. , vol.25


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.