메뉴 건너뛰기




Volumn 19, Issue 8, 2010, Pages 1356-1362

The effect of anterior-posterior shear load on the wear of ProDisc-L TDR

Author keywords

TDR; Total disc replacement; Wear ProDisc L

Indexed keywords

BOVINE SERUM ALBUMIN; POLYETHYLENE;

EID: 77956943425     PISSN: 09406719     EISSN: None     Source Type: Journal    
DOI: 10.1007/s00586-010-1396-8     Document Type: Article
Times cited : (33)

References (33)
  • 3
    • 8644249805 scopus 로고    scopus 로고
    • A review of spinal fusion for degenerative disc disease: Need for alternative treatment approach of disc arthroplasty?
    • Lee CK, Langrana NA (2004) A review of spinal fusion for degenerative disc disease: need for alternative treatment approach of disc arthroplasty? Spine J 4(6 Suppl 1):S173-S176
    • (2004) Spine J , vol.4 , Issue.6 SUPPL. 1
    • Lee, C.K.1    Langrana, N.A.2
  • 4
    • 0035581162 scopus 로고    scopus 로고
    • 2001 Volvo Award winner in clinical studies: Lumbar fusion versus nonsurgical treatment for chronic low back pain: A multicenter randomized controlled trial from the Swedish Lumbar Spine Study Group
    • Fritzell P, Hagg O, Wessberg P, Nordwall A (2001) 2001 Volvo Award winner in clinical studies: Lumbar fusion versus nonsurgical treatment for chronic low back pain: a multicenter randomized controlled trial from the Swedish Lumbar Spine Study Group. Spine 26:2521-2532
    • (2001) Spine , vol.26 , pp. 2521-2532
    • Fritzell, P.1    Hagg, O.2    Wessberg, P.3    Nordwall, A.4
  • 7
    • 0038671838 scopus 로고    scopus 로고
    • Complications in lumbar fusion surgery for chronic low back pain: Comparison of three surgical techniques used in a prospective randomized study. A report from the Swedish Lumbar Spine Study Group
    • Fritzell P, Hagg O, Nordwall A (2003) Complications in lumbar fusion surgery for chronic low back pain: comparison of three surgical techniques used in a prospective randomized study. A report from the Swedish Lumbar Spine Study Group. Eur Spine J 12:178-189
    • (2003) Eur Spine J , vol.12 , pp. 178-189
    • Fritzell, P.1    Hagg, O.2    Nordwall, A.3
  • 8
    • 0031105323 scopus 로고    scopus 로고
    • Polyethylene wear in total hip and knee arthroplasties
    • Lewis G (1997) Polyethylene wear in total hip and knee arthroplasties. J Biomed Mater Res 38(1):55-75
    • (1997) J Biomed Mater Res , vol.38 , Issue.1 , pp. 55-75
    • Lewis, G.1
  • 9
    • 0142089924 scopus 로고    scopus 로고
    • Spinal implant debris-induced osteolysis
    • Hallab NJ, Cunningham BW, Jacobs JJ (2003) Spinal implant debris-induced osteolysis. Spine 28(20):S125-S138
    • (2003) Spine , vol.28 , Issue.20
    • Hallab, N.J.1    Cunningham, B.W.2    Jacobs, J.J.3
  • 11
    • 53549113634 scopus 로고    scopus 로고
    • Chronic failure of a lumbar total disc replacement with osteolysis. Report of a case with nineteen-year follow-up
    • Devin CJ, Myers TG, Kang JD (2008) Chronic failure of a lumbar total disc replacement with osteolysis. Report of a case with nineteen-year follow-up. J Bone Joint Surg Am 90(10):2230-2234
    • (2008) J Bone Joint Surg Am , vol.90 , Issue.10 , pp. 2230-2234
    • Devin, C.J.1    Myers, T.G.2    Kang, J.D.3
  • 13
    • 77956942994 scopus 로고    scopus 로고
    • Standard guide for functional, kinematic, and wear assessment of total disc prostheses
    • (2005) Standard guide for functional, kinematic, and wear assessment of total disc prostheses. In: ASTM F 2423-05
    • (2005) ASTM F 2423-05
  • 16
    • 33748043654 scopus 로고    scopus 로고
    • In vitro wear assessment of the Charite′ Artificial Disc according to ASTM recommendations
    • Serhan H, Dooris A, Parsons ML, Ares PJ, Gabriel SM (2006) In vitro wear assessment of the Charite′ Artificial Disc according to ASTM recommendations. Spine 31(17):1900-1910
    • (2006) Spine , vol.31 , Issue.17 , pp. 1900-1910
    • Serhan, H.1    Dooris, A.2    Parsons, M.L.3    Ares, P.J.4    Gabriel, S.M.5
  • 17
    • 58149459606 scopus 로고    scopus 로고
    • Biotribological evaluation of artificial disc arthroplasty devices: Influence of loading and kinematic patterns during in vitro wear simulation
    • Grupp TM (2009) Biotribological evaluation of artificial disc arthroplasty devices: influence of loading and kinematic patterns during in vitro wear simulation. Eur Spine J 18:98-108
    • (2009) Eur Spine J , vol.18 , pp. 98-108
    • Grupp, T.M.1
  • 19
    • 0033104976 scopus 로고    scopus 로고
    • Low back three-dimensional joint forces, kinematics, and kinetics during walking
    • Callaghan JP, Patla AE, McGill SM (1999) Low back three-dimensional joint forces, kinematics, and kinetics during walking. Clin Biomech 14(3):203-216
    • (1999) Clin Biomech , vol.14 , Issue.3 , pp. 203-216
    • Callaghan, J.P.1    Patla, A.E.2    McGill, S.M.3
  • 20
    • 33751002631 scopus 로고    scopus 로고
    • Trunk muscle activation and associated lumbar spine joint shear force under different levels of external forward force applied to the trunk
    • Kingma I, Staudenmann D, van Dienne JH (2007) Trunk muscle activation and associated lumbar spine joint shear force under different levels of external forward force applied to the trunk. J Electromyogr Kinesiol 17:14-24
    • (2007) J Electromyogr Kinesiol , vol.17 , pp. 14-24
    • Kingma, I.1    Staudenmann, D.2    Van Dienne, J.H.3
  • 21
    • 77956928156 scopus 로고    scopus 로고
    • First generation TDR devices do not adequately resist shear in the lumbosacral spine
    • The International Society for the Advancement of Spinal Surgery London
    • Metzger MF, Bradford D, Lotz JC (2009) First generation TDR devices do not adequately resist shear in the lumbosacral spine. In: SAS09: Nineth annual global symposium on Motion preservation technology, The International Society for the Advancement of Spinal Surgery, London
    • (2009) SAS09: Nineth Annual Global Symposium on Motion Preservation Technology
    • Metzger, M.F.1    Bradford, D.2    Lotz, J.C.3
  • 26
    • 0032893674 scopus 로고    scopus 로고
    • Kinematics and movement sequencing during flexion of the lumbar spine
    • Gatton ML, Pearcy MJ (1999) Kinematics and movement sequencing during flexion of the lumbar spine. Clin Biomech 14(6):376-383
    • (1999) Clin Biomech , vol.14 , Issue.6 , pp. 376-383
    • Gatton, M.L.1    Pearcy, M.J.2
  • 27
    • 0032893675 scopus 로고    scopus 로고
    • Segmental movements of the spine during treadmill walking with normal speed
    • Syczewska M, Oberg T, Karlsson D (1999) Segmental movements of the spine during treadmill walking with normal speed. Clin Biomech 14:384-388
    • (1999) Clin Biomech , vol.14 , pp. 384-388
    • Syczewska, M.1    Oberg, T.2    Karlsson, D.3
  • 28
    • 34547657581 scopus 로고    scopus 로고
    • Wear simulation of the ProDisc-L disc replacement using adaptive finite element analysis
    • Rawlinson JJ, Punga KP, Gunsallus KL, Bartel DL, Wright TM (2007) Wear simulation of the ProDisc-L disc replacement using adaptive finite element analysis. J Neurosurg Spine 7(2):165-173
    • (2007) J Neurosurg Spine , vol.7 , Issue.2 , pp. 165-173
    • Rawlinson, J.J.1    Punga, K.P.2    Gunsallus, K.L.3    Bartel, D.L.4    Wright, T.M.5
  • 29
    • 13344270633 scopus 로고
    • Contact and rubbing of flat surfaces
    • Archard JF (1953) Contact and rubbing of flat surfaces. J Appl Phys 24:981-988
    • (1953) J Appl Phys , vol.24 , pp. 981-988
    • Archard, J.F.1
  • 30
    • 58149295463 scopus 로고    scopus 로고
    • Wear simulation of ultra-high molecular weight polyethylene hip implants by incorporating the effects of cross-shear and contact pressure
    • Kang L, Galvin AL, Brown TD, Fisher J, Jin ZM (2008) Wear simulation of ultra-high molecular weight polyethylene hip implants by incorporating the effects of cross-shear and contact pressure. Proc Inst Mech Eng Part H J Eng Med 222(7):1049-1064
    • (2008) Proc Inst Mech Eng Part H J Eng Med , vol.222 , Issue.7 , pp. 1049-1064
    • Kang, L.1    Galvin, A.L.2    Brown, T.D.3    Fisher, J.4    Jin, Z.M.5
  • 31
    • 0029725748 scopus 로고    scopus 로고
    • Mechanistic and morphological origins of ultra-high weight molecular polyethylene wear debris in total joint replacement
    • Wang A, Stark C, Dumbleton JH (1996) Mechanistic and morphological origins of ultra-high weight molecular polyethylene wear debris in total joint replacement. Proc Inst Mech Eng Part H J Eng Med 210:141-155
    • (1996) Proc Inst Mech Eng Part H J Eng Med , vol.210 , pp. 141-155
    • Wang, A.1    Stark, C.2    Dumbleton, J.H.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.