메뉴 건너뛰기




Volumn 109, Issue 4, 2010, Pages 1159-1168

Detection limit of negative staining electron microscopy for the diagnosis of bioterrorism-related micro-organisms

Author keywords

airfuge; bioterrorism; detection limit; diagnosis; negative staining; particle enrichment; poxvirus; spore

Indexed keywords

BACTERIOLOGY; BIOTECHNOLOGY; CENTRIFUGATION; DIAGNOSIS; ELECTRON MICROSCOPES; ELECTRONS; VIRUSES;

EID: 77956901475     PISSN: 13645072     EISSN: 13652672     Source Type: Journal    
DOI: 10.1111/j.1365-2672.2010.04737.x     Document Type: Article
Times cited : (28)

References (41)
  • 1
    • 0023188012 scopus 로고
    • Rapid virus subunit visualization by direct sedimentation of samples on electron microscope grids
    • Alain, R., Nadon, F., Séguin, C., Payment, P. Trudel, M. (1987) Rapid virus subunit visualization by direct sedimentation of samples on electron microscope grids. J Virol Methods 16, 209 216.
    • (1987) J Virol Methods , vol.16 , pp. 209-216
    • Alain, R.1    Nadon, F.2    Séguin, C.3    Payment, P.4    Trudel, M.5
  • 2
    • 0033025337 scopus 로고    scopus 로고
    • Diagnostic electron microscopy is still a timely and rewarding method
    • Biel, S.S. Gelderblom, H.R. (1999a) Diagnostic electron microscopy is still a timely and rewarding method. J Clin Virol 13, 105 119.
    • (1999) J Clin Virol , vol.13 , pp. 105-119
    • Biel, S.S.1    Gelderblom, H.R.2
  • 3
    • 0002550426 scopus 로고    scopus 로고
    • Electron microscopy of viruses
    • In. ed. . Cann, A
    • Biel, S.S. Gelderblom, H.R. (1999b) Electron microscopy of viruses. In Virus Cell Culture ed. Cann, A. pp. 111 147.
    • (1999) Virus Cell Culture , pp. 111-147
    • Biel, S.S.1    Gelderblom, H.R.2
  • 4
    • 0742304263 scopus 로고    scopus 로고
    • Detection of human polyomaviruses in urine from bone marrow transplant patients: Comparison of electron microscopy with PCR
    • Biel, S.S., Nitsche, A., Kurth, A., Siegert, W., Özel, M. Gelderblom, H.R. (2004) Detection of human polyomaviruses in urine from bone marrow transplant patients: comparison of electron microscopy with PCR. Clin Chem 50, 306 312.
    • (2004) Clin Chem , vol.50 , pp. 306-312
    • Biel, S.S.1    Nitsche, A.2    Kurth, A.3    Siegert, W.4    Özel, M.5    Gelderblom, H.R.6
  • 5
    • 33646835810 scopus 로고
    • A negative staining method for high resolution electron microscopy of viruses
    • Brenner, S. Horne, R.W. (1959) A negative staining method for high resolution electron microscopy of viruses. Biochim Biophys Acta 34, 103 110.
    • (1959) Biochim Biophys Acta , vol.34 , pp. 103-110
    • Brenner, S.1    Horne, R.W.2
  • 6
    • 30144436798 scopus 로고    scopus 로고
    • Application of transmission electron microscopy to the clinical study of viral and bacterial infections: Present and future
    • Curry, A., Appleton, H. Dowsett, B. (2006) Application of transmission electron microscopy to the clinical study of viral and bacterial infections: present and future. Micron 37, 91 106.
    • (2006) Micron , vol.37 , pp. 91-106
    • Curry, A.1    Appleton, H.2    Dowsett, B.3
  • 7
    • 0028038385 scopus 로고
    • Particle-surface interaction in thin vitrified films for cryo-electron microscopy
    • Cyrklaff, M., Roos, N., Gross, H. Dubochet, J. (1994) Particle-surface interaction in thin vitrified films for cryo-electron microscopy. J Microsc-Oxford 175, 135 142.
    • (1994) J Microsc-Oxford , vol.175 , pp. 135-142
    • Cyrklaff, M.1    Roos, N.2    Gross, H.3    Dubochet, J.4
  • 9
    • 77956905581 scopus 로고    scopus 로고
    • Virus enrichment using the Airfuge for rapid diagnostic em in infectious diseases
    • Gelderblom, H.R. (2006) Virus enrichment using the Airfuge for rapid diagnostic EM in infectious diseases. Rotor 4, 4 5.
    • (2006) Rotor , vol.4 , pp. 4-5
    • Gelderblom, H.R.1
  • 11
    • 33846958462 scopus 로고    scopus 로고
    • Arguments pro disinfection in diagnostic electron microscopy: A response to Madeley and Biel
    • Gelderblom, H., Bannert, N. Pauli, G. (2007) Arguments pro disinfection in diagnostic electron microscopy: a response to Madeley and Biel. J Infect 54, 307 308.
    • (2007) J Infect , vol.54 , pp. 307-308
    • Gelderblom, H.1    Bannert, N.2    Pauli, G.3
  • 12
    • 0019433230 scopus 로고
    • Improved detection of viruses by electron microscopy after direct ultracentrifuge preparation of specimens
    • Hammond, G.W., Hazelton, P.R., Chuang, I. Klisko, B. (1981) Improved detection of viruses by electron microscopy after direct ultracentrifuge preparation of specimens. J Clin Microbiol 14, 210 221.
    • (1981) J Clin Microbiol , vol.14 , pp. 210-221
    • Hammond, G.W.1    Hazelton, P.R.2    Chuang, I.3    Klisko, B.4
  • 13
    • 0003597312 scopus 로고    scopus 로고
    • Negative staining and cryoelectron microscopy: The thin film techniques
    • Harris, J.R. (1997) Negative staining and cryoelectron microscopy: the thin film techniques. Royal Society Handbooks, Vol. 35.
    • (1997) Royal Society Handbooks , vol.35
    • Harris, J.R.1
  • 15
    • 0037341428 scopus 로고    scopus 로고
    • Electron microscopy for rapid diagnosis of infectious agents in emergent situations
    • Hazelton, P.R. Gelderblom, H.R. (2003) Electron microscopy for rapid diagnosis of infectious agents in emergent situations. Emerg Infect Dis 9, 294 303.
    • (2003) Emerg Infect Dis , vol.9 , pp. 294-303
    • Hazelton, P.R.1    Gelderblom, H.R.2
  • 17
    • 33646136882 scopus 로고    scopus 로고
    • Confirmation of electron microscopy results by direct testing of viruses adhered to grids using nucleic acid amplification techniques
    • Johnsen, C.K., Böttiger, B. Blom, J. (2006) Confirmation of electron microscopy results by direct testing of viruses adhered to grids using nucleic acid amplification techniques. J Virol Methods 134, 92 98.
    • (2006) J Virol Methods , vol.134 , pp. 92-98
    • Johnsen, C.K.1    Böttiger, B.2    Blom, J.3
  • 18
    • 0027166044 scopus 로고
    • Viruses accumulate spontaneously near droplet surfaces: A method to concentrate viruses for electron microscopy
    • Johnson, R.P.C. Gregory, D.W. (1993) Viruses accumulate spontaneously near droplet surfaces: a method to concentrate viruses for electron microscopy. J Microsc-Oxford 171, 125 136.
    • (1993) J Microsc-Oxford , vol.171 , pp. 125-136
    • Johnson, R.P.C.1    Gregory, D.W.2
  • 19
    • 0021671887 scopus 로고
    • A simplified microwell pseudoreplica for the detection of viruses by electron microscopy and immunoelectron microscopy
    • Katz, D., Straussman, Y. Shahar, A. (1984) A simplified microwell pseudoreplica for the detection of viruses by electron microscopy and immunoelectron microscopy. J Virol Methods 9, 185 192.
    • (1984) J Virol Methods , vol.9 , pp. 185-192
    • Katz, D.1    Straussman, Y.2    Shahar, A.3
  • 20
    • 37849011175 scopus 로고    scopus 로고
    • Orthopoxvirus detection in environmental specimens during suspected bioterror attacks: Inhibitory influences of common household products
    • Kurth, A., Achenbach, J., Miller, L., Mackay, I.M., Pauli, G. Nitsche, A. (2008) Orthopoxvirus detection in environmental specimens during suspected bioterror attacks: inhibitory influences of common household products. Appl Environ Microbiol 1, 32 37.
    • (2008) Appl Environ Microbiol , vol.1 , pp. 32-37
    • Kurth, A.1    Achenbach, J.2    Miller, L.3    MacKay, I.M.4    Pauli, G.5    Nitsche, A.6
  • 21
    • 0035664569 scopus 로고    scopus 로고
    • Bioterrorism: A clear and present danger
    • Lane, H.C., Montagne, J.L. Fauci, A.S. (2001) Bioterrorism: a clear and present danger. Nat Med 7, 1271 1273.
    • (2001) Nat Med , vol.7 , pp. 1271-1273
    • Lane, H.C.1    Montagne, J.L.2    Fauci, A.S.3
  • 22
    • 0019731246 scopus 로고
    • Ultrastructure of sheep erythrocyte plasma membrane and cytoskeletons bound to solid supports
    • Lang, R.D.A., Nermut, M.V. Williams, L.D. (1981) Ultrastructure of sheep erythrocyte plasma membrane and cytoskeletons bound to solid supports. J Cell Sci 49, 383 399.
    • (1981) J Cell Sci , vol.49 , pp. 383-399
    • Lang, R.D.A.1    Nermut, M.V.2    Williams, L.D.3
  • 23
    • 34250765537 scopus 로고    scopus 로고
    • Rapid diagnostic thin section electron microscopy of bacterial endospores
    • Laue, M., Niederwöhrmeier, B. Bannert, N. (2007) Rapid diagnostic thin section electron microscopy of bacterial endospores. J Microbiol Meth 70, 45 54.
    • (2007) J Microbiol Meth , vol.70 , pp. 45-54
    • Laue, M.1    Niederwöhrmeier, B.2    Bannert, N.3
  • 24
    • 0018143499 scopus 로고
    • Die Ultrazentrifugation in der Virusdiagnostik
    • Liebermann, H. (1978) Die Ultrazentrifugation in der Virusdiagnostik. Arch Exp Vet 32, 427 434.
    • (1978) Arch Exp Vet , vol.32 , pp. 427-434
    • Liebermann, H.1
  • 25
    • 33745657904 scopus 로고    scopus 로고
    • For debate: Is disinfection of specimens, which may contain unknown or bio-terrorist organisms, essential before electron microscopic examination
    • Madeley, C.R. Biel, S.S. (2006) For debate: is disinfection of specimens, which may contain unknown or bio-terrorist organisms, essential before electron microscopic examination. J Infect 53, 70 74.
    • (2006) J Infect , vol.53 , pp. 70-74
    • Madeley, C.R.1    Biel, S.S.2
  • 26
    • 0014788428 scopus 로고
    • Centrifugal sedimentation of virus particles for electron microscopic counting
    • Mathews, J. Buthala, D.A. (1970) Centrifugal sedimentation of virus particles for electron microscopic counting. J Virol 5, 598 603.
    • (1970) J Virol , vol.5 , pp. 598-603
    • Mathews, J.1    Buthala, D.A.2
  • 27
    • 84986464732 scopus 로고
    • Detection and identification of viruses by electron microscopy
    • Miller, S.E. (1986) Detection and identification of viruses by electron microscopy. J Electron Microsc Tech 4, 265 301.
    • (1986) J Electron Microsc Tech , vol.4 , pp. 265-301
    • Miller, S.E.1
  • 28
    • 0043172525 scopus 로고    scopus 로고
    • Bioterrorism and electron microscopy differentiation of poxviruses from herpesviruses: Does and don′ts
    • Miller, S.E. (2003) Bioterrorism and electron microscopy differentiation of poxviruses from herpesviruses: does and don′ts. Ultrastruct Pathol 27, 133 140.
    • (2003) Ultrastruct Pathol , vol.27 , pp. 133-140
    • Miller, S.E.1
  • 29
    • 33646125305 scopus 로고    scopus 로고
    • Surveillance of bioterrorism agents: Considerations for em laboratories
    • Miller, S.E. (2004) Surveillance of bioterrorism agents: considerations for EM laboratories. Micros Today 4, 56 59.
    • (2004) Micros Today , vol.4 , pp. 56-59
    • Miller, S.E.1
  • 30
    • 17144439323 scopus 로고
    • Elektronenmikroskopische Partikelzählung in der Virologie. I. Zentrifugierröhrchen zur direkten Sedimentation von Viren auf Netzträger
    • Müller, G. (1969) Elektronenmikroskopische Partikelzählung in der Virologie. I. Zentrifugierröhrchen zur direkten Sedimentation von Viren auf Netzträger. Arch Gesamte Virusforsch 27, 339 351.
    • (1969) Arch Gesamte Virusforsch , vol.27 , pp. 339-351
    • Müller, G.1
  • 31
    • 0019190160 scopus 로고
    • Electron microscopical particle counting in virology. III. Parameters governing the efficiency of sedimentation techniques and its improvement with the application of poly-L-lysine
    • Müller, G., Nielsen, G. Baigent, C.L. (1980) Electron microscopical particle counting in virology. III. Parameters governing the efficiency of sedimentation techniques and its improvement with the application of poly-L-lysine. Arch Virol 64, 311 318.
    • (1980) Arch Virol , vol.64 , pp. 311-318
    • Müller, G.1    Nielsen, G.2    Baigent, C.L.3
  • 32
    • 77956912779 scopus 로고
    • Zur Effektivität von Airfuge und Poly-L-Lysin in der elektronenmikroskopischen Präparation von Virussuspensionen
    • Müller, G., Gelderblom, H. Nielsen, G. (1981) Zur Effektivität von Airfuge und Poly-L-Lysin in der elektronenmikroskopischen Präparation von Virussuspensionen. GIT Fachzeitschrift Labor Suppl 25, 7 11.
    • (1981) GIT Fachzeitschrift Labor Suppl , vol.25 , pp. 7-11
    • Müller, G.1    Gelderblom, H.2    Nielsen, G.3
  • 35
    • 0032845432 scopus 로고    scopus 로고
    • Aum Shinrikyo: Once and future threat?
    • Olson, K.B. (1999) Aum Shinrikyo: once and future threat? Emerg Infect Dis 5, 513 516.
    • (1999) Emerg Infect Dis , vol.5 , pp. 513-516
    • Olson, K.B.1
  • 36
    • 0014824510 scopus 로고
    • A technique for the electron microscopy of protein-free particle suspensions by the negative staining method
    • Reissig, M. Orrell, S.A. (1970) A technique for the electron microscopy of protein-free particle suspensions by the negative staining method. J Ultrastr Res 32, 107 117.
    • (1970) J Ultrastr Res , vol.32 , pp. 107-117
    • Reissig, M.1    Orrell, S.A.2
  • 39
    • 0036892638 scopus 로고    scopus 로고
    • Anode glow discharge plasma treatment enhances calcium phosphate adsorption plates
    • Shibata, Y. Miyazaki, T. (2002) Anode glow discharge plasma treatment enhances calcium phosphate adsorption plates. J Dent Res 81, 841 844.
    • (2002) J Dent Res , vol.81 , pp. 841-844
    • Shibata, Y.1    Miyazaki, T.2
  • 40
    • 0014533169 scopus 로고
    • Commitment to sporulation in Bacillus subtilis and its relationship to development of Actinomycin resistance
    • Sterlini, J.M. Mandelstam, J. (1969) Commitment to sporulation in Bacillus subtilis and its relationship to development of Actinomycin resistance. Biochem J 113, 29 37.
    • (1969) Biochem J , vol.113 , pp. 29-37
    • Sterlini, J.M.1    Mandelstam, J.2
  • 41
    • 0037509844 scopus 로고    scopus 로고
    • A multicentre collaboration to investigate the cause of severe acute respiratory syndrome
    • World Health Organisation
    • World Health Organisation (2003) A multicentre collaboration to investigate the cause of severe acute respiratory syndrome. Lancet 361, 1730 1733.
    • (2003) Lancet , vol.361 , pp. 1730-1733


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.