메뉴 건너뛰기




Volumn 28, Issue 8, 2010, Pages 1192-1199

Implementation and evaluation of simultaneous video-electroencephalography and functional magnetic resonance imaging

Author keywords

[No Author keywords available]

Indexed keywords

ARTICLE; CONTROLLED STUDY; ELECTROENCEPHALOGRAPHY; FUNCTIONAL MAGNETIC RESONANCE IMAGING; HAND; HUMAN; HUMAN EXPERIMENT; IMAGE ANALYSIS; IMAGE QUALITY; INFORMATION PROCESSING; INFORMATION RETRIEVAL; INTERMETHOD COMPARISON; MOTOR PERFORMANCE; OXYGEN BLOOD LEVEL; PRIORITY JOURNAL; RADIOFREQUENCY; TASK PERFORMANCE; VIDEORECORDING;

EID: 77956871323     PISSN: 0730725X     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.mri.2010.01.001     Document Type: Article
Times cited : (16)

References (40)
  • 2
    • 0036278436 scopus 로고    scopus 로고
    • Video-EEG monitoring in adults
    • Cascino G.D. Video-EEG monitoring in adults. Epilepsia 2002, 43(Suppl 3):80-93.
    • (2002) Epilepsia , vol.43 , Issue.SUPPL. 3 , pp. 80-93
    • Cascino, G.D.1
  • 4
    • 0032189998 scopus 로고    scopus 로고
    • Identification of EEG events in the MR scanner: the problem of pulse artifact and a method for its subtraction
    • Allen P.J., Polizzi G., Krakow K., Fish D.R., Lemieux L. Identification of EEG events in the MR scanner: the problem of pulse artifact and a method for its subtraction. Neuroimage 1998, 8(3):229-239.
    • (1998) Neuroimage , vol.8 , Issue.3 , pp. 229-239
    • Allen, P.J.1    Polizzi, G.2    Krakow, K.3    Fish, D.R.4    Lemieux, L.5
  • 5
    • 0033870442 scopus 로고    scopus 로고
    • A method for removing imaging artifact from continuous EEG recorded during functional MRI
    • Allen P.J., Josephs O., Turner R. A method for removing imaging artifact from continuous EEG recorded during functional MRI. Neuroimage 2000, 12(2):230-239.
    • (2000) Neuroimage , vol.12 , Issue.2 , pp. 230-239
    • Allen, P.J.1    Josephs, O.2    Turner, R.3
  • 8
    • 33646557029 scopus 로고    scopus 로고
    • Hemodynamic correlates of epileptiform discharges: an EEG-fMRI study of 63 patients with focal epilepsy
    • Salek Haddadi A., Diehl B., Hamandi K., Merschhemke M., Liston A., Friston K., et al. Hemodynamic correlates of epileptiform discharges: an EEG-fMRI study of 63 patients with focal epilepsy. Brain Res 2006, 1088(1):148-166.
    • (2006) Brain Res , vol.1088 , Issue.1 , pp. 148-166
    • Salek Haddadi, A.1    Diehl, B.2    Hamandi, K.3    Merschhemke, M.4    Liston, A.5    Friston, K.6
  • 11
    • 0034857509 scopus 로고    scopus 로고
    • Presurgical evaluation of epilepsy
    • Rosenow F., Luders H. Presurgical evaluation of epilepsy. Brain 2001, 124(Pt 9):1683-1700.
    • (2001) Brain , vol.124 , Issue.PART 9 , pp. 1683-1700
    • Rosenow, F.1    Luders, H.2
  • 13
    • 27244450645 scopus 로고    scopus 로고
    • Generalized epileptic discharges show thalamocortical activation and suspension of the default state of the brain
    • Gotman J., Grova C., Bagshaw A., Kobayashi E., Aghakhani Y., Dubeau F. Generalized epileptic discharges show thalamocortical activation and suspension of the default state of the brain. Proc Natl Acad Sci U S A 2005, 102(42):15236-15240.
    • (2005) Proc Natl Acad Sci U S A , vol.102 , Issue.42 , pp. 15236-15240
    • Gotman, J.1    Grova, C.2    Bagshaw, A.3    Kobayashi, E.4    Aghakhani, Y.5    Dubeau, F.6
  • 14
    • 33646104666 scopus 로고    scopus 로고
    • Widespread and intense BOLD changes during brief focal electrographic seizures
    • Kobayashi E., Hawco C.S., Grova C., Dubeau F., Gotman J. Widespread and intense BOLD changes during brief focal electrographic seizures. Neurology 2006, 66(7):1049-1055.
    • (2006) Neurology , vol.66 , Issue.7 , pp. 1049-1055
    • Kobayashi, E.1    Hawco, C.S.2    Grova, C.3    Dubeau, F.4    Gotman, J.5
  • 15
    • 33845519359 scopus 로고    scopus 로고
    • EEG/fMRI study of ictal and interictal epileptic activity: methodological issues and future perspectives in clinical practice
    • Di Bonaventura C., Vaudano A.E., Carni M., Pantano P., Nucciarelli V., Garreffa G., et al. EEG/fMRI study of ictal and interictal epileptic activity: methodological issues and future perspectives in clinical practice. Epilepsia 2006, 47(Suppl 5):52-58.
    • (2006) Epilepsia , vol.47 , Issue.SUPPL. 5 , pp. 52-58
    • Di Bonaventura, C.1    Vaudano, A.E.2    Carni, M.3    Pantano, P.4    Nucciarelli, V.5    Garreffa, G.6
  • 17
    • 49449113628 scopus 로고    scopus 로고
    • Different structures involved during ictal and interictal epileptic activity in malformations of cortical development: an EEG-fMRI study
    • Tyvaert L., Hawco C., Kobayashi E., LeVan P., Dubeau F., Gotman J. Different structures involved during ictal and interictal epileptic activity in malformations of cortical development: an EEG-fMRI study. Brain 2008, 131(Pt 8):2042-2060.
    • (2008) Brain , vol.131 , Issue.PART 8 , pp. 2042-2060
    • Tyvaert, L.1    Hawco, C.2    Kobayashi, E.3    LeVan, P.4    Dubeau, F.5    Gotman, J.6
  • 18
    • 57449112764 scopus 로고    scopus 로고
    • EEG-fMRI study of the ictal and interictal epileptic activity in patients with eyelid myoclonia with absences
    • Liu Y., Yang T., Liao W., Yang X., Liu I., Yan B., et al. EEG-fMRI study of the ictal and interictal epileptic activity in patients with eyelid myoclonia with absences. Epilepsia 2008.
    • (2008) Epilepsia
    • Liu, Y.1    Yang, T.2    Liao, W.3    Yang, X.4    Liu, I.5    Yan, B.6
  • 19
    • 51249101057 scopus 로고    scopus 로고
    • Simultaneous EEG-fMRI in drug-naive children with newly diagnosed absence epilepsy
    • Moeller F., Siebner H.R., Wolff S., Muhle H., Granert O., Jansen O., et al. Simultaneous EEG-fMRI in drug-naive children with newly diagnosed absence epilepsy. Epilepsia 2008, 49(9):1510-1519.
    • (2008) Epilepsia , vol.49 , Issue.9 , pp. 1510-1519
    • Moeller, F.1    Siebner, H.R.2    Wolff, S.3    Muhle, H.4    Granert, O.5    Jansen, O.6
  • 20
    • 2442605725 scopus 로고    scopus 로고
    • FMRI activation during spike and wave discharges in idiopathic generalized epilepsy
    • Aghakhani Y., Bagshaw A.P., Benar C.G., Hawco C., Andermann F., Dubeau F., et al. fMRI activation during spike and wave discharges in idiopathic generalized epilepsy. Brain 2004, 127(Pt 5):1127-1144.
    • (2004) Brain , vol.127 , Issue.PART 5 , pp. 1127-1144
    • Aghakhani, Y.1    Bagshaw, A.P.2    Benar, C.G.3    Hawco, C.4    Andermann, F.5    Dubeau, F.6
  • 22
    • 36248939759 scopus 로고    scopus 로고
    • BOLD and perfusion changes during epileptic generalised spike wave activity
    • Hamandi K., Laufs H., Noth U., Carmichael D.W., Duncan J.S., Lemieux L. BOLD and perfusion changes during epileptic generalised spike wave activity. Neuroimage 2008, 39(2):608-618.
    • (2008) Neuroimage , vol.39 , Issue.2 , pp. 608-618
    • Hamandi, K.1    Laufs, H.2    Noth, U.3    Carmichael, D.W.4    Duncan, J.S.5    Lemieux, L.6
  • 23
    • 0037177084 scopus 로고    scopus 로고
    • FMRI/EEG in paroxysmal activity elicited by elimination of central vision and fixation
    • Iannetti G.D., Di B.C., Pantano P., Giallonardo A.T., Romanelli P.L., Bozzao L., et al. fMRI/EEG in paroxysmal activity elicited by elimination of central vision and fixation. Neurology 2002, 58(6):976-979.
    • (2002) Neurology , vol.58 , Issue.6 , pp. 976-979
    • Iannetti, G.D.1    Di, B.C.2    Pantano, P.3    Giallonardo, A.T.4    Romanelli, P.L.5    Bozzao, L.6
  • 24
    • 33645278981 scopus 로고    scopus 로고
    • Linking generalized spike-and-wave discharges and resting state brain activity by using EEG/fMRI in a patient with absence seizures
    • Laufs H., Lengler U., Hamandi K., Kleinschmidt A., Krakow K. Linking generalized spike-and-wave discharges and resting state brain activity by using EEG/fMRI in a patient with absence seizures. Epilepsia 2006, 47(2):444-448.
    • (2006) Epilepsia , vol.47 , Issue.2 , pp. 444-448
    • Laufs, H.1    Lengler, U.2    Hamandi, K.3    Kleinschmidt, A.4    Krakow, K.5
  • 25
    • 77956883893 scopus 로고    scopus 로고
    • Independent component analysis reveals dynamic ictal BOLD responses in EEG-fMRI data from focal epilepsy patients
    • LeVan P., Tyvaert L., Moeller F., Gotman J. Independent component analysis reveals dynamic ictal BOLD responses in EEG-fMRI data from focal epilepsy patients. Neuroimage 2009.
    • (2009) Neuroimage
    • LeVan, P.1    Tyvaert, L.2    Moeller, F.3    Gotman, J.4
  • 28
    • 0033833774 scopus 로고    scopus 로고
    • Fixation-off sensitivity as a model of continuous epileptiform discharges: electroencephalographic, neuropsychological and functional MRI findings
    • Krakow K., Baxendale S.A., Maguire E.A., Krishnamoorthy E.S., Lemieux L., Scott C.A., et al. Fixation-off sensitivity as a model of continuous epileptiform discharges: electroencephalographic, neuropsychological and functional MRI findings. Epilepsy Res 2000, 42(1):1-6.
    • (2000) Epilepsy Res , vol.42 , Issue.1 , pp. 1-6
    • Krakow, K.1    Baxendale, S.A.2    Maguire, E.A.3    Krishnamoorthy, E.S.4    Lemieux, L.5    Scott, C.A.6
  • 29
    • 33748678165 scopus 로고    scopus 로고
    • Event-related fMRI of myoclonic jerks arising from dysplastic cortex
    • Archer J.S., Waites A.B., Abbott D.F., Federico P., Jackson G.D. Event-related fMRI of myoclonic jerks arising from dysplastic cortex. Epilepsia 2006, 47(9):1487-1492.
    • (2006) Epilepsia , vol.47 , Issue.9 , pp. 1487-1492
    • Archer, J.S.1    Waites, A.B.2    Abbott, D.F.3    Federico, P.4    Jackson, G.D.5
  • 31
    • 0343340069 scopus 로고    scopus 로고
    • Hemodynamic changes in simple partial epilepsy: a functional MRI study
    • Krings T., Topper R., Reinges M.H., Foltys H., Spetzger U., Chiappa K.H., et al. Hemodynamic changes in simple partial epilepsy: a functional MRI study. Neurology 2000, 54(2):524-527.
    • (2000) Neurology , vol.54 , Issue.2 , pp. 524-527
    • Krings, T.1    Topper, R.2    Reinges, M.H.3    Foltys, H.4    Spetzger, U.5    Chiappa, K.H.6
  • 32
  • 33
    • 33747804274 scopus 로고    scopus 로고
    • Synchronization facilitates removal of MRI artefacts from concurrent EEG recordings and increases usable bandwidth
    • Mandelkow H., Halder P., Boesiger P., Brandeis D. Synchronization facilitates removal of MRI artefacts from concurrent EEG recordings and increases usable bandwidth. Neuroimage 2006, 32(3):1120-1126.
    • (2006) Neuroimage , vol.32 , Issue.3 , pp. 1120-1126
    • Mandelkow, H.1    Halder, P.2    Boesiger, P.3    Brandeis, D.4
  • 34
    • 0033776453 scopus 로고    scopus 로고
    • Video camera and light system for application in magnetic resonance scanners
    • Wild B., Erb M., Lemke N., Scholz P., Bartels M., Grodd W. Video camera and light system for application in magnetic resonance scanners. Magn Reson Imaging 2000, 18(7):893-896.
    • (2000) Magn Reson Imaging , vol.18 , Issue.7 , pp. 893-896
    • Wild, B.1    Erb, M.2    Lemke, N.3    Scholz, P.4    Bartels, M.5    Grodd, W.6
  • 35
    • 0034839919 scopus 로고    scopus 로고
    • Spiral-in/out BOLD fMRI for increased SNR and reduced susceptibility artifacts
    • Glover G.H., Law C.S. Spiral-in/out BOLD fMRI for increased SNR and reduced susceptibility artifacts. Magn Reson Med 2001, 46(3):515-522.
    • (2001) Magn Reson Med , vol.46 , Issue.3 , pp. 515-522
    • Glover, G.H.1    Law, C.S.2
  • 36
    • 33749250701 scopus 로고    scopus 로고
    • Reducing interscanner variability of activation in a multicenter fMRI study: controlling for signal-to-fluctuation-noise-ratio (SFNR) differences
    • Friedman L., Glover G.H. Reducing interscanner variability of activation in a multicenter fMRI study: controlling for signal-to-fluctuation-noise-ratio (SFNR) differences. Neuroimage 2006, 33(2):471-481.
    • (2006) Neuroimage , vol.33 , Issue.2 , pp. 471-481
    • Friedman, L.1    Glover, G.H.2
  • 37
    • 0031932352 scopus 로고    scopus 로고
    • Self-navigated spiral fMRI: interleaved versus single-shot
    • Glover G.H., Lai S. Self-navigated spiral fMRI: interleaved versus single-shot. Magn Reson Med 1998, 39(3):361-368.
    • (1998) Magn Reson Med , vol.39 , Issue.3 , pp. 361-368
    • Glover, G.H.1    Lai, S.2
  • 38
    • 0028586154 scopus 로고
    • Functional cooperativity of human cortical motor areas during self-paced simple finger movements. A high-resolution MRI study
    • Boecker H., Kleinschmidt A., Requardt M., Hanicke W., Merboldt K.D., Frahm J. Functional cooperativity of human cortical motor areas during self-paced simple finger movements. A high-resolution MRI study. Brain 1994, 117(Pt 6):1231-1239.
    • (1994) Brain , vol.117 , Issue.PART 6 , pp. 1231-1239
    • Boecker, H.1    Kleinschmidt, A.2    Requardt, M.3    Hanicke, W.4    Merboldt, K.D.5    Frahm, J.6
  • 39
    • 0033847090 scopus 로고    scopus 로고
    • Functional MR imaging activation after finger tapping has a shorter duration in the basal ganglia than in the sensorimotor cortex
    • Moritz C.H., Meyerand M.E., Cordes D., Haughton V.M. Functional MR imaging activation after finger tapping has a shorter duration in the basal ganglia than in the sensorimotor cortex. AJNR Am J Neuroradiol 2000, 21(7):1228-1234.
    • (2000) AJNR Am J Neuroradiol , vol.21 , Issue.7 , pp. 1228-1234
    • Moritz, C.H.1    Meyerand, M.E.2    Cordes, D.3    Haughton, V.M.4
  • 40
    • 0033776460 scopus 로고    scopus 로고
    • Whole-brain functional MR imaging activation from a finger-tapping task examined with independent component analysis
    • Moritz C.H., Haughton V.M., Cordes D., Quigley M., Meyerand M.E. Whole-brain functional MR imaging activation from a finger-tapping task examined with independent component analysis. AJNR Am J Neuroradiol 2000, 21(9):1629-1635.
    • (2000) AJNR Am J Neuroradiol , vol.21 , Issue.9 , pp. 1629-1635
    • Moritz, C.H.1    Haughton, V.M.2    Cordes, D.3    Quigley, M.4    Meyerand, M.E.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.