메뉴 건너뛰기




Volumn 38, Issue 6, 1997, Pages 943-952

Recording of EEG during fMRI experiments: Patient safety

Author keywords

Electronencephalography; Field measurements; Funcional MRI; Safety

Indexed keywords

ACCIDENT PREVENTION; BIOELECTRIC PHENOMENA; ELECTRODES; ELECTROMAGNETIC FIELDS; MAGNETIC FIELDS; MAGNETIC RESONANCE IMAGING;

EID: 0030702136     PISSN: 07403194     EISSN: None     Source Type: Journal    
DOI: 10.1002/mrm.1910380614     Document Type: Article
Times cited : (269)

References (32)
  • 2
    • 0001906218 scopus 로고
    • Techniques for monitoring the EEG and triggering functional magnetic resonance imaging scans time-locked to the patient's focal or generalized epileptic discharges
    • J. R. Ives, S. Warach, M. R. Patel, G. Schlaug, R. R. Edelman, D. L. Schomer, Techniques for monitoring the EEG and triggering functional magnetic resonance imaging scans time-locked to the patient's focal or generalized epileptic discharges. Epilepsia 36, S95 (1995).
    • (1995) Epilepsia , vol.36
    • Ives, J.R.1    Warach, S.2    Patel, M.R.3    Schlaug, G.4    Edelman, R.R.5    Schomer, D.L.6
  • 6
    • 0022773329 scopus 로고
    • Monitoring during MRI
    • F. G. Shellock, Monitoring during MRI. Med. Electron. 93-97 (1986).
    • (1986) Med. Electron. , pp. 93-97
    • Shellock, F.G.1
  • 7
    • 0027603223 scopus 로고
    • Sedation, anaesthesia, and physiologic monitoring during MR imaging: Evaluation of procedures and equipment
    • B. A. Holshouser, D. B. Hinshaw Jr, F. G. Shellock, Sedation, anaesthesia, and physiologic monitoring during MR imaging: evaluation of procedures and equipment. J. Magn. Reson. Imaging 3, 553-558 (1993).
    • (1993) J. Magn. Reson. Imaging , vol.3 , pp. 553-558
    • Holshouser, B.A.1    Hinshaw Jr., D.B.2    Shellock, F.G.3
  • 8
  • 9
    • 0242476911 scopus 로고
    • Severe burn of the finger caused by using a pulse oximeter during MR imaging
    • F. G. Shellock, G. L. Slimp, Severe burn of the finger caused by using a pulse oximeter during MR imaging [letter]. Am. J. Roentgenol. 153, 1105 (1989).
    • (1989) Am. J. Roentgenol. , vol.153 , pp. 1105
    • Shellock, F.G.1    Slimp, G.L.2
  • 10
    • 0027173563 scopus 로고
    • Severe burns resulting from magnetic resonance imaging with cardiopulmonary monitoring. Risks and relevant safety precautions
    • T. R. Brown, B. Goldstein, J. Little, Severe burns resulting from magnetic resonance imaging with cardiopulmonary monitoring. Risks and relevant safety precautions. Am. J. Phys. Med. Rehabil. 72, 166-167 (1993).
    • (1993) Am. J. Phys. Med. Rehabil. , vol.72 , pp. 166-167
    • Brown, T.R.1    Goldstein, B.2    Little, J.3
  • 14
    • 0023848727 scopus 로고
    • Monitoring of acutely ill patients during nuclear magnetic resonance imaging: Use of a time-varying filter electrocardiographic gating device to reduce gradient artifacts
    • R. Rokey, R. E. Wendt, D. L. Johnston, Monitoring of acutely ill patients during nuclear magnetic resonance imaging: use of a time-varying filter electrocardiographic gating device to reduce gradient artifacts. Magn. Reson. Med. 6, 240-245 (1988).
    • (1988) Magn. Reson. Med. , vol.6 , pp. 240-245
    • Rokey, R.1    Wendt, R.E.2    Johnston, D.L.3
  • 19
    • 0038302832 scopus 로고
    • Bioeffects of MRI and Patient Safety
    • (M. J. Bronskill, P. Sprawls, Eds.), AAPM, Woodbury, New York
    • D. J. Schaefer, Bioeffects of MRI and Patient Safety, in "The Physics of MRI - 1992 AAPM Summer School Proceedings" (M. J. Bronskill, P. Sprawls, Eds.), AAPM, Woodbury, New York, 1993.
    • (1993) The Physics of MRI - 1992 AAPM Summer School Proceedings
    • Schaefer, D.J.1
  • 20
    • 46549092488 scopus 로고
    • An efficient, highly homogeneous radiofrequency coil for whole-body NMR imaging at 1.5T
    • C. E. Hayes, W. A. Edelstein, J. F. Schenck, O. M. Mueller, M Ash, An efficient, highly homogeneous radiofrequency coil for whole-body NMR imaging at 1.5T. J. Magn. Reson. 63, 622-628 (1985).
    • (1985) J. Magn. Reson. , vol.63 , pp. 622-628
    • Hayes, C.E.1    Edelstein, W.A.2    Schenck, J.F.3    Mueller, O.M.4    Ash, M.5
  • 24
  • 25
    • 85036683364 scopus 로고    scopus 로고
    • Patient safety during EEG recording in the MRI scanner: Measurement of induced potentials
    • P. J. Allen, L. Lemieux, M. R. Symms, F. Franconi, D. R. Fish, Patient safety during EEG recording in the MRI scanner: measurement of induced potentials. Epilepsia 37, (1996).
    • (1996) Epilepsia , vol.37
    • Allen, P.J.1    Lemieux, L.2    Symms, M.R.3    Franconi, F.4    Fish, D.R.5
  • 26
    • 0027379107 scopus 로고
    • MR procedures and biomedical implants, materials, and devices: 1993 update
    • F. G. Shellock, S. Morisoli, E. Kanal, MR procedures and biomedical implants, materials, and devices: 1993 update. Radiology 189, 587-599 (1993).
    • (1993) Radiology , vol.189 , pp. 587-599
    • Shellock, F.G.1    Morisoli, S.2    Kanal, E.3
  • 32
    • 0017537223 scopus 로고
    • Burns thresholds to radiofrequency leakage currents from surgical diathermy equipment
    • B. H. Brown, S. G. Johnson, R. P. Betts, L. Henry, Burns thresholds to radiofrequency leakage currents from surgical diathermy equipment. J. Med. Eng. Technol. 1, 277-281 (1977).
    • (1977) J. Med. Eng. Technol. , vol.1 , pp. 277-281
    • Brown, B.H.1    Johnson, S.G.2    Betts, R.P.3    Henry, L.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.