-
1
-
-
62849125838
-
Assessment of tissue prolapse after balloon-expandable stenting: Influence of stent cell geometry
-
10.1016/j.medengphy.2008.11.002 19109049
-
C Capelli F Gervaso L Petrini G Dubini F Migliavacca 2009 Assessment of tissue prolapse after balloon-expandable stenting: influence of stent cell geometry Med. Eng. Phys. 31 441 447 10.1016/j.medengphy.2008.11.002 19109049
-
(2009)
Med. Eng. Phys.
, vol.31
, pp. 441-447
-
-
Capelli, C.1
Gervaso, F.2
Petrini, L.3
Dubini, G.4
Migliavacca, F.5
-
2
-
-
43449098495
-
Microstructure and mechanical properties of microalloyed and equal channel angular extruded Mg alloys
-
10.1016/j.scriptamat.2008.03.017 1:CAS:528:DC%2BD1cXlvFKktrk%3D
-
FH Dalla Torre AC Hanzi PJ Uggowitzer 2008 Microstructure and mechanical properties of microalloyed and equal channel angular extruded Mg alloys Scripta Mater. 59 207 210 10.1016/j.scriptamat.2008.03.017 1:CAS:528: DC%2BD1cXlvFKktrk%3D
-
(2008)
Scripta Mater.
, vol.59
, pp. 207-210
-
-
Dalla Torre, F.H.1
Hanzi, A.C.2
Uggowitzer, P.J.3
-
3
-
-
38349062270
-
Realistic finite element-based stent design: The impact of balloon folding
-
10.1016/j.jbiomech.2007.08.014 17920068
-
M De Beule P Mortier SG Carlier B Verhegghe R Van Impe P Verdonck 2008 Realistic finite element-based stent design: the impact of balloon folding J. Biomech. 41 383 389 10.1016/j.jbiomech.2007.08.014 17920068
-
(2008)
J. Biomech.
, vol.41
, pp. 383-389
-
-
De Beule, M.1
Mortier, P.2
Carlier, S.G.3
Verhegghe, B.4
Van Impe, R.5
Verdonck, P.6
-
4
-
-
47949113474
-
Finite element comparison of performance related characteristics of balloon expandable stents
-
1:STN:280:DC%2BD1cvnt1Krsw%3D%3D
-
EW Donnelly MS Bruzzi T Connolley PE McHugh 2007 Finite element comparison of performance related characteristics of balloon expandable stents Comput. Methods Biomech. Biomed. Eng. 10 103 110 1:STN:280: DC%2BD1cvnt1Krsw%3D%3D
-
(2007)
Comput. Methods Biomech. Biomed. Eng.
, vol.10
, pp. 103-110
-
-
Donnelly, E.W.1
Bruzzi, M.S.2
Connolley, T.3
McHugh, P.E.4
-
5
-
-
34249655184
-
Temporary scaffolding of coronary arteries with bioabsorbable magnesium stents: A prospective, non-randomised multicentre trial
-
DOI 10.1016/S0140-6736(07)60853-8, PII S0140673607608538
-
R Erbel C Di Mario J Bartunek J Bonnier B de Bruyne FR Eberli P Erne M Haude B Heublein M Horrigan C Ilsley D Bose J Koolen TF Luscher N Weissman R Waksman P-A Investigators 2007 Temporary scaffolding of coronary arteries with bioabsorbable magnesium stents: a prospective, non-randomised multicentre trial Lancet 369 1869 1875 10.1016/S0140-6736(07)60853-8 1:CAS:528: DC%2BD2sXmtVarur0%3D 17544767 (Pubitemid 46829357)
-
(2007)
Lancet
, vol.369
, Issue.9576
, pp. 1869-1875
-
-
Erbel, R.1
Di Mario, C.2
Bartunek, J.3
Bonnier, J.4
De Bruyne, B.5
Eberli, F.R.6
Erne, P.7
Haude, M.8
Heublein, B.9
Horrigan, M.10
Ilsley, C.11
Bose, D.12
Koolen, J.13
Luscher, T.F.14
Weissman, N.15
Waksman, R.16
-
6
-
-
41549127424
-
On the effects of different strategies in modelling balloon-expandable stenting by means of finite element method
-
10.1016/j.jbiomech.2008.01.027 18374340
-
F Gervaso C Capelli L Petrini S Lattanzio L Di Virgilio F Migliavacca 2008 On the effects of different strategies in modelling balloon-expandable stenting by means of finite element method J. Biomech. 41 1206 1212 10.1016/j.jbiomech.2008.01.027 18374340
-
(2008)
J. Biomech.
, vol.41
, pp. 1206-1212
-
-
Gervaso, F.1
Capelli, C.2
Petrini, L.3
Lattanzio, S.4
Di Virgilio, L.5
Migliavacca, F.6
-
7
-
-
56549090894
-
In vitro corrosion and biocompatibility of binary magnesium alloys
-
10.1016/j.biomaterials.2008.10.021 1:CAS:528:DC%2BD1cXhsVegu7fI 19000636
-
XN Gu YF Zheng Y Cheng SP Zhong TF Xi 2009 In vitro corrosion and biocompatibility of binary magnesium alloys Biomaterials 30 484 498 10.1016/j.biomaterials.2008.10.021 1:CAS:528:DC%2BD1cXhsVegu7fI 19000636
-
(2009)
Biomaterials
, vol.30
, pp. 484-498
-
-
Gu, X.N.1
Zheng, Y.F.2
Cheng, Y.3
Zhong, S.P.4
Xi, T.F.5
-
8
-
-
0035849543
-
Intracoronary stenting and angiographic results: Strut thickness effect on restenosis outcome (ISAR-STEREO) trail
-
1:STN:280:DC%2BD3MzjsVSksQ%3D%3D 11401938
-
A Kastrati J Mehilli J Dirschinger F Dotzer H Schühlen FJ Neumann M Fleckenstein C Pfafferott M Seyfarth A Schömig 2001 Intracoronary stenting and angiographic results: strut thickness effect on restenosis outcome (ISAR-STEREO) trail Circulation 103 2816 2821 1:STN:280:DC%2BD3MzjsVSksQ%3D%3D 11401938
-
(2001)
Circulation
, vol.103
, pp. 2816-2821
-
-
Kastrati, A.1
Mehilli, J.2
Dirschinger, J.3
Dotzer, F.4
Schühlen, H.5
Neumann, F.J.6
Fleckenstein, M.7
Pfafferott, C.8
Seyfarth, M.9
Schömig, A.10
-
9
-
-
58549120749
-
Experimental studies and numerical analysis of the inflation and interaction of vascular balloon catheter-stent systems
-
10.1007/s10439-008-9606-9 19048377
-
D Kiousis A Wulff G Holzapfel 2009 Experimental studies and numerical analysis of the inflation and interaction of vascular balloon catheter-stent systems Ann. Biomed. Eng. 37 315 330 10.1007/s10439-008-9606-9 19048377
-
(2009)
Ann. Biomed. Eng.
, vol.37
, pp. 315-330
-
-
Kiousis, D.1
Wulff, A.2
Holzapfel, G.3
-
10
-
-
20444475661
-
Cardiovascular stent design and vessel stresses: A finite element analysis
-
DOI 10.1016/j.jbiomech.2004.07.022, PII S0021929004003756
-
C Lally F Dolan PJ Prendergast 2005 Cardiovascular stent design and vessel stresses: a finite element analysis J. Biomech. 38 1574 1581 10.1016/j.jbiomech.2004.07.022 1:STN:280:DC%2BD2MzhtFentg%3D%3D 15958213 (Pubitemid 40813479)
-
(2005)
Journal of Biomechanics
, vol.38
, Issue.8
, pp. 1574-1581
-
-
Lally, C.1
Dolan, F.2
Prendergast, P.J.3
-
11
-
-
62949118408
-
Shape optimization of coronary artery stent based on a parametric model
-
10.1016/j.finel.2009.01.001
-
N Li HW Zhang HJ Ouyang 2009 Shape optimization of coronary artery stent based on a parametric model Finite Elem. Anal. Des. 45 468 475 10.1016/j.finel.2009.01.001
-
(2009)
Finite Elem. Anal. Des.
, vol.45
, pp. 468-475
-
-
Li, N.1
Zhang, H.W.2
Ouyang, H.J.3
-
12
-
-
28844502833
-
Fatigue and life prediction for cobalt-chromium stents: A fracture mechanics analysis
-
DOI 10.1016/j.biomaterials.2005.10.012, PII S0142961205009233
-
VR Marry R Burgermeister RB Grishaber RO Ritchie 2006 Fatigue and life prediction for cobalt-chromium stents: a fracture mechanics analysis Biomaterials 27 1988 2000 10.1016/j.biomaterials.2005.10.012 (Pubitemid 41760438)
-
(2006)
Biomaterials
, vol.27
, Issue.9
, pp. 1988-2000
-
-
Marrey, R.V.1
Burgermeister, R.2
Grishaber, R.B.3
Ritchie, R.O.4
-
13
-
-
7544232441
-
Analysis of the mechanical performance of a cardiovascular stent design based on micromechanical modelling
-
JP McGarry BP O'Donnell PE McHugh JG McGarry 2004 Analysis of the mechanical performance of a cardiovascular stent design based on micromechanical modelling Comp. Mater. Sci. 31 421 438
-
(2004)
Comp. Mater. Sci.
, vol.31
, pp. 421-438
-
-
McGarry, J.P.1
O'Donnell, B.P.2
McHugh, P.E.3
McGarry, J.G.4
-
14
-
-
21144448039
-
Effects of stent structure on stent flexibility measurements
-
DOI 10.1007/s10439-005-2807-6
-
K Mori T Saito 2005 Effects of stent structure on stent flexibility measurements Ann. Biomed. Eng. 33 733 742 10.1007/s10439-005-2807-6 16078613 (Pubitemid 40878481)
-
(2005)
Annals of Biomedical Engineering
, vol.33
, Issue.6
, pp. 733-742
-
-
Mori, K.1
Saito, T.2
-
16
-
-
12144250767
-
Preliminary results after application of absorbable metal stents in patients with critical limb ischemia
-
DOI 10.1583/04-1349R.1
-
P Peeters M Bosiers J Verbist K Deloose B Heublein 2005 Preliminary results after application of absorbable metal stents in patients with critical limb ischemia J. Endovasc. Ther. 12 1 5 10.1583/04-1349R.1 15683259 (Pubitemid 40229382)
-
(2005)
Journal of Endovascular Therapy
, vol.12
, Issue.1
, pp. 1-5
-
-
Peeters, P.1
Bosiers, M.2
Verbist, J.3
Deloose, K.4
Heublein, B.5
-
17
-
-
38849159075
-
Fatigue and durability of Nitinol stents
-
DOI 10.1016/j.jmbbm.2007.08.001, PII S1751616107000161
-
AR Pelton V Schroeder MR Mitchell XY Gong M Barney SW Robertson 2008 Fatigue and durability of Nitinol stents J. Mech. Behav. Biomed. Mater. 1 153 164 10.1016/j.jmbbm.2007.08.001 1:STN:280:DC%2BD1MrgsVGmtQ%3D%3D 19627780 (Pubitemid 351200079)
-
(2008)
Journal of the Mechanical Behavior of Biomedical Materials
, vol.1
, Issue.2
, pp. 153-164
-
-
Pelton, A.R.1
Schroeder, V.2
Mitchell, M.R.3
Gong, X.-Y.4
Barney, M.5
Robertson, S.W.6
-
18
-
-
62849122420
-
The influence of plaque composition on underlying arterial wall stress during stent expansion: The case for lesion-specific stents
-
10.1016/j.medengphy.2008.11.005 19129001
-
I Pericevic C Lally D Toner DJ Kelly 2009 The influence of plaque composition on underlying arterial wall stress during stent expansion: the case for lesion-specific stents Med. Eng. Phys. 31 428 433 10.1016/j.medengphy.2008. 11.005 19129001
-
(2009)
Med. Eng. Phys.
, vol.31
, pp. 428-433
-
-
Pericevic, I.1
Lally, C.2
Toner, D.3
Kelly, D.J.4
-
19
-
-
1442299848
-
Numerical investigation of the intravascular coronary stent flexibility
-
DOI 10.1016/j.jbiomech.2003.09.002, PII S0021929003003397
-
L Petrini F Migliavacca F Auricchio G Dubini 2004 Numerical investigation of the intravascular coronary stent flexibility J. Biomech. 37 495 501 10.1016/j.jbiomech.2003.09.002 14996561 (Pubitemid 38292988)
-
(2004)
Journal of Biomechanics
, vol.37
, Issue.4
, pp. 495-501
-
-
Petrini, L.1
Migliavacca, F.2
Auricchio, F.3
Dubini, G.4
-
20
-
-
2342501392
-
Femtosecond laser micromachining: Current status and applications
-
NH Rizvi 2003 Femtosecond laser micromachining: current status and applications RIKEN Rev. 50 107 112
-
(2003)
RIKEN Rev.
, vol.50
, pp. 107-112
-
-
Rizvi, N.H.1
-
21
-
-
33646265009
-
Bioabsorbable metal stents for percutaneous treatment of critical recoarctation of the aorta in a newborn
-
10.1002/ccd.20756
-
D Schranz P Zartner I Michel-Behnke H Akinturk 2006 Bioabsorbable metal stents for percutaneous treatment of critical recoarctation of the aorta in a newborn Catheter. Cardio. Inte. 67 671 673 10.1002/ccd.20756
-
(2006)
Catheter. Cardio. Inte.
, vol.67
, pp. 671-673
-
-
Schranz, D.1
Zartner, P.2
Michel-Behnke, I.3
Akinturk, H.4
-
22
-
-
38849191742
-
Serial imaging and histology illustrating the degradation of a bioabsorbable magnesium stent in a porcine coronary artery
-
DOI 10.1093/eurheartj/ehm365
-
TLP Slottow R Pakala R Waksman 2008 Serial imaging and histology illustrating the degradation of a bioabsorbable magnesium stent in a porcine coronary artery Eur. Heart J. 29 314 10.1093/eurheartj/ehm365 (Pubitemid 351197742)
-
(2008)
European Heart Journal
, vol.29
, Issue.3
, pp. 314
-
-
Pinto Slottow, T.L.1
Pakala, R.2
Waksman, R.3
-
24
-
-
33646229771
-
Drug-eluting stents and late adverse clinical outcomes-lessons learned, lessons awaited
-
10.1016/j.jacc.2006.03.019 1:CAS:528:DC%2BD28XksFalsbY%3D 16697332
-
S Tsimikas 2006 Drug-eluting stents and late adverse clinical outcomes-lessons learned, lessons awaited J. Am. Coll. Cardiol. 47 2112 2115 10.1016/j.jacc.2006.03.019 1:CAS:528:DC%2BD28XksFalsbY%3D 16697332
-
(2006)
J. Am. Coll. Cardiol.
, vol.47
, pp. 2112-2115
-
-
Tsimikas, S.1
-
25
-
-
35848967011
-
Promise and challenges of bioabsorbable stents
-
DOI 10.1002/ccd.21176
-
R Waksman 2007 Promise and challenges of bioabsorbable stents Catheter. Cardio. Inte. 70 407 414 10.1002/ccd.21176 (Pubitemid 350194989)
-
(2007)
Catheterization and Cardiovascular Interventions
, vol.70
, Issue.3
, pp. 407-414
-
-
Waksman, R.1
-
26
-
-
33749640689
-
Safety and efficacy of bioabsorbable magnesium alloy stents in porcine coronary arteries
-
DOI 10.1002/ccd.20727
-
R Waksman R Pakala PK Kuchulakanti R Baffour D Hellinga R Seabron FO Tio E Wittchow S Hartwig C Harder R Rohde B Heublein A Andreae KH Waldmann A Haverich 2006 Safety and efficacy of bioabsorbable magnesium alloy stents in porcine coronary arteries Catheter. Cardio. Inte. 68 607 617 10.1002/ccd.20727 (Pubitemid 44546055)
-
(2006)
Catheterization and Cardiovascular Interventions
, vol.68
, Issue.4
, pp. 607-617
-
-
Waksman, R.1
Pakala, R.2
Kuchulakanti, P.K.3
Baffour, R.4
Hellinga, D.5
Seabron, R.6
Tio, F.O.7
Wittchow, E.8
Hartwig, S.9
Harder, C.10
Rohde, R.11
Heublein, B.12
Andreae, A.13
Waldmann, K.-H.14
Haverich, A.15
-
27
-
-
0012981186
-
Adaptive response surface method - A global optimization scheme for approximation-based design problems
-
10.1080/03052150108940940
-
GG Wang ZM Dong P Aitchison 2001 Adaptive response surface method-a global optimization scheme for approximation-based design problems Eng. Optimiz. 33 707 733 10.1080/03052150108940940
-
(2001)
Eng. Optimiz.
, vol.33
, pp. 707-733
-
-
Wang, G.G.1
Dong, Z.M.2
Aitchison, P.3
-
28
-
-
47049099949
-
Stress corrosion cracking in magnesium alloys: Characterization and prevention
-
10.1007/s11837-007-0104-6 1:CAS:528:DC%2BD2sXhtVWgtb7L
-
N Winzer A Atrens W Dietzel G Song KU Kainer 2007 Stress corrosion cracking in magnesium alloys: characterization and prevention JOM 59 49 53 10.1007/s11837-007-0104-6 1:CAS:528:DC%2BD2sXhtVWgtb7L
-
(2007)
JOM
, vol.59
, pp. 49-53
-
-
Winzer, N.1
Atrens, A.2
Dietzel, W.3
Song, G.4
Kainer, K.U.5
-
29
-
-
34548593681
-
Delivery and release of nitinol stent in carotid artery and their interactions: A finite element analysis
-
DOI 10.1016/j.jbiomech.2007.02.024, PII S0021929007001145
-
W Wu M Qi XP Liu DZ Yang WQ Wang 2007 Delivery and release of nitinol stent in carotid artery and their interactions: a finite element analysis J. Biomech. 40 3034 3040 10.1016/j.jbiomech.2007.02.024 17511995 (Pubitemid 47385815)
-
(2007)
Journal of Biomechanics
, vol.40
, Issue.13
, pp. 3034-3040
-
-
Wu, W.1
Qi, M.2
Liu, X.-P.3
Yang, D.-Z.4
Wang, W.-Q.5
-
30
-
-
56149106942
-
Topology optimization of a novel stent platform with drug reservoirs
-
10.1016/j.medengphy.2008.02.010 18407779
-
W Wu DZ Yang YY Huang M Qi WQ Wang 2008 Topology optimization of a novel stent platform with drug reservoirs Med. Eng. Phys. 30 1177 1185 10.1016/j.medengphy.2008.02.010 18407779
-
(2008)
Med. Eng. Phys.
, vol.30
, pp. 1177-1185
-
-
Wu, W.1
Yang, D.Z.2
Huang, Y.Y.3
Qi, M.4
Wang, W.Q.5
|