메뉴 건너뛰기




Volumn 41, Issue 2, 2008, Pages 383-389

Realistic finite element-based stent design: The impact of balloon folding

Author keywords

(Folded) Balloon; Design; Finite element method; Stent

Indexed keywords

COATINGS; DATA REDUCTION; FINITE ELEMENT METHOD; NUMERICAL METHODS; OPTIMIZATION;

EID: 38349062270     PISSN: 00219290     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.jbiomech.2007.08.014     Document Type: Article
Times cited : (174)

References (21)
  • 1
    • 2442674610 scopus 로고    scopus 로고
    • American Heart Association, American Heart Association, Dallas, Tx
    • American Heart Association. Heart Disease and Stroke Statistics-2006 Updated (2006), American Heart Association, Dallas, Tx
    • (2006) Heart Disease and Stroke Statistics-2006 Updated
  • 3
    • 33750378236 scopus 로고    scopus 로고
    • Effects of stent design parameters on normal artery wall mechanics
    • Bedoya J., Meyer C., Timmins L., et al. Effects of stent design parameters on normal artery wall mechanics. Journal of Biomechanical Engineering 5 (2006) 757-765
    • (2006) Journal of Biomechanical Engineering , vol.5 , pp. 757-765
    • Bedoya, J.1    Meyer, C.2    Timmins, L.3
  • 4
    • 20844456925 scopus 로고    scopus 로고
    • Intravascular ultrasonic assessment of stent diameters derived from manufacturer's compliance charts
    • de Ribamar Costa J., Mintz G., Carlier S.G., et al. Intravascular ultrasonic assessment of stent diameters derived from manufacturer's compliance charts. American Journal of Cardiology 96 (2005) 74-78
    • (2005) American Journal of Cardiology , vol.96 , pp. 74-78
    • de Ribamar Costa, J.1    Mintz, G.2    Carlier, S.G.3
  • 5
    • 18044372225 scopus 로고    scopus 로고
    • Finite element analysis of covered microstents
    • Gu L., Santra S., Mericle R.A., et al. Finite element analysis of covered microstents. Journal of Biomechanics 38 (2005) 1221-1227
    • (2005) Journal of Biomechanics , vol.38 , pp. 1221-1227
    • Gu, L.1    Santra, S.2    Mericle, R.A.3
  • 6
    • 33749260906 scopus 로고    scopus 로고
    • Towards a computational methodology for optimizing angioplasty treatments with stenting
    • Holzapfel G.A., and Ogden R.W. (Eds), Springer, Heidelberg
    • Holzapfel G.A., Stadler M., and Gasser T.C. Towards a computational methodology for optimizing angioplasty treatments with stenting. In: Holzapfel G.A., and Ogden R.W. (Eds). Mechanics of Biological Tissue (2005), Springer, Heidelberg 207-220
    • (2005) Mechanics of Biological Tissue , pp. 207-220
    • Holzapfel, G.A.1    Stadler, M.2    Gasser, T.C.3
  • 7
    • 24644523719 scopus 로고    scopus 로고
    • Incremental cost-effectiveness of drug-eluting stents compared with a third-generation bare-metal stent in a real-world setting: randomised basel stent kosten effektivitäts trial (BASKET)
    • Kaiser C., Brunner H.P., Buser P.T., et al. Incremental cost-effectiveness of drug-eluting stents compared with a third-generation bare-metal stent in a real-world setting: randomised basel stent kosten effektivitäts trial (BASKET). Lancet 366 (2005) 921-929
    • (2005) Lancet , vol.366 , pp. 921-929
    • Kaiser, C.1    Brunner, H.P.2    Buser, P.T.3
  • 10
    • 20444475661 scopus 로고    scopus 로고
    • Cardiovascular stent design and vessel stresses: a finite element analysis
    • Lally C., Dolan F., and Prendergast P.J. Cardiovascular stent design and vessel stresses: a finite element analysis. Journal of Biomechanics 38 (2005) 1574-1581
    • (2005) Journal of Biomechanics , vol.38 , pp. 1574-1581
    • Lally, C.1    Dolan, F.2    Prendergast, P.J.3
  • 11
    • 25444471259 scopus 로고    scopus 로고
    • Finite element analysis of the implantation of a balloon-expandable stent in a stenosed artery
    • Liang D.K., Yang D.Z., Qi M., et al. Finite element analysis of the implantation of a balloon-expandable stent in a stenosed artery. International Journal of Cardiology 104 (2005) 314-318
    • (2005) International Journal of Cardiology , vol.104 , pp. 314-318
    • Liang, D.K.1    Yang, D.Z.2    Qi, M.3
  • 12
    • 28844502833 scopus 로고    scopus 로고
    • Fatigue and life prediction for cobalt-chromium stents: a fracture mechanics analysis
    • Marrey R.V., Burgermeister R., Grishaber R.B., et al. Fatigue and life prediction for cobalt-chromium stents: a fracture mechanics analysis. Biomaterials 27 (2006) 1988-2000
    • (2006) Biomaterials , vol.27 , pp. 1988-2000
    • Marrey, R.V.1    Burgermeister, R.2    Grishaber, R.B.3
  • 13
    • 10444258936 scopus 로고    scopus 로고
    • A predictive study of the mechanical behaviour of coronary stents by computer modelling
    • Migliavacca F., Petrini L., Montanari V., et al. A predictive study of the mechanical behaviour of coronary stents by computer modelling. Medical Engineering and Physics 27 (2005) 13-18
    • (2005) Medical Engineering and Physics , vol.27 , pp. 13-18
    • Migliavacca, F.1    Petrini, L.2    Montanari, V.3
  • 14
    • 0037030658 scopus 로고    scopus 로고
    • A randomized comparison of a sirolimus-eluting stent with a standard stent for coronary revascularization
    • Morice J.C., Serruys P.W., Sousa J.E., et al. A randomized comparison of a sirolimus-eluting stent with a standard stent for coronary revascularization. New England Journal of Medicine 346 (2002) 1773-1780
    • (2002) New England Journal of Medicine , vol.346 , pp. 1773-1780
    • Morice, J.C.1    Serruys, P.W.2    Sousa, J.E.3
  • 15
    • 0038610567 scopus 로고    scopus 로고
    • The stress-strain behavior of coronary stent struts is size dependent
    • Murphy B.P., Savage P., McHugh P.E., et al. The stress-strain behavior of coronary stent struts is size dependent. Annals of Biomedical Engineering 31 (2003) 686-691
    • (2003) Annals of Biomedical Engineering , vol.31 , pp. 686-691
    • Murphy, B.P.1    Savage, P.2    McHugh, P.E.3
  • 16
    • 0033525544 scopus 로고    scopus 로고
    • Balloon-artery interactions during stent placement. A finite element analysis approach to pressure, compliance, and stent design as contributors to vascular injury
    • Rogers C., Tseng D.Y., Squire J.C., et al. Balloon-artery interactions during stent placement. A finite element analysis approach to pressure, compliance, and stent design as contributors to vascular injury. Circulation Research 84 (1999) 378-383
    • (1999) Circulation Research , vol.84 , pp. 378-383
    • Rogers, C.1    Tseng, D.Y.2    Squire, J.C.3
  • 18
    • 20844442291 scopus 로고    scopus 로고
    • Four-year angiographic and intravascular ultrasound follow-up of patients treated with sirolimus-eluting stents
    • Sousa J.E., Costa M.A., Abizaid A., et al. Four-year angiographic and intravascular ultrasound follow-up of patients treated with sirolimus-eluting stents. Circulation 111 (2005) 2326-2329
    • (2005) Circulation , vol.111 , pp. 2326-2329
    • Sousa, J.E.1    Costa, M.A.2    Abizaid, A.3
  • 19
    • 38349007835 scopus 로고    scopus 로고
    • Timoshenko, S., 1955. Strength of Materials - Part I Elementary Theory and Problems, third ed.
  • 20
    • 10744229988 scopus 로고    scopus 로고
    • Localized hypersensitivity and late coronary thrombosis secondary to a sirolimus-eluting stent: should we be cautious?
    • Virmani R., Guagliumi G., Farb A., et al. Localized hypersensitivity and late coronary thrombosis secondary to a sirolimus-eluting stent: should we be cautious?. Circulation 109 (2004) 701-705
    • (2004) Circulation , vol.109 , pp. 701-705
    • Virmani, R.1    Guagliumi, G.2    Farb, A.3
  • 21
    • 27744557004 scopus 로고    scopus 로고
    • Analysis of the transient expansion behavior and design optimization of coronary stents by finite element method
    • Wang W.-Q., Liang D.-K., Yang D.-Z., et al. Analysis of the transient expansion behavior and design optimization of coronary stents by finite element method. Journal of Biomechanics 39 (2006) 21-32
    • (2006) Journal of Biomechanics , vol.39 , pp. 21-32
    • Wang, W.-Q.1    Liang, D.-K.2    Yang, D.-Z.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.