Volumn 20, Issue 3, 2010, Pages 166-174

Artifact free T2*-weighted imaging at high spatial resolution using segmented EPI sequences;Artefakt-freie hochaufgelöste T2*-gewichtete Bildgebung mit segmentierten EPI-Sequenzen

Author keywords

Echo train shifting; High resolution fMRI; Multi shot EPI; Reversed gradient method; T2* weighted imaging

Indexed keywords

ARTICLE; ARTIFACT REDUCTION; CONTRAST ENHANCEMENT; ECHO PLANAR IMAGING; FEASIBILITY STUDY; FUNCTIONAL MAGNETIC RESONANCE IMAGING; IMAGE DISPLAY; IMAGE ENHANCEMENT; IMAGE PROCESSING; IMAGE QUALITY; MEASUREMENT; PHANTOM; RADIOLOGICAL PARAMETERS; SIGNAL NOISE RATIO; SIMULATION;

EID: 77956619473     PISSN: 09393889     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.zemedi.2010.02.005     Document Type: Article
Times cited : (6)

References (22)
  • 1
    • 36749049768 scopus 로고    scopus 로고
    • Funktionelle MR-Bildgebung für die neurochirurgische Operationsplanung
    • Erb M., Saur R. Funktionelle MR-Bildgebung für die neurochirurgische Operationsplanung. Z Med Phys 2007, 17:242-249.
    • (2007) Z Med Phys , vol.17 , pp. 242-249
    • Erb, M.1    Saur, R.2
  • 3
    • 0025336246 scopus 로고
    • Oxygenation-Sensitive Contrast in Magnetic Resonance Image of Rodent Brain at High Magnetic Fields
    • Ogawa S., Lee T.M., Nayak A.S., Glynn P. Oxygenation-Sensitive Contrast in Magnetic Resonance Image of Rodent Brain at High Magnetic Fields. Magn Reson Med 1990, 14:68-78.
    • (1990) Magn Reson Med , vol.14 , pp. 68-78
    • Ogawa, S.1    Lee, T.M.2    Nayak, A.S.3    Glynn, P.4
  • 4
    • 0025630001 scopus 로고
    • Brain magnetic resonance imaging with contrast dependent on blood oxygenation
    • Ogawa S., Lee T.M., Kay A.R., Tank D.W. Brain magnetic resonance imaging with contrast dependent on blood oxygenation. Proc Natl Acad Sci USA 1990, 87:9868-9872.
    • (1990) Proc Natl Acad Sci USA , vol.87 , pp. 9868-9872
    • Ogawa, S.1    Lee, T.M.2    Kay, A.R.3    Tank, D.W.4
  • 5
    • 36149042452 scopus 로고
    • Multi-planar image formation using NMR spin echoes
    • Mansfield P. Multi-planar image formation using NMR spin echoes. J Phys C 1977, 10:L55-L58.
    • (1977) J Phys C , vol.10
    • Mansfield, P.1
  • 6
    • 51849090200 scopus 로고
    • Echo planar imaging on a standard 1.5 Tesla imager
    • Schad L.R., Bock M., Müller E., Lorenz W.J. Echo planar imaging on a standard 1.5 Tesla imager. Z Med Phys 1995, 5:205-207.
    • (1995) Z Med Phys , vol.5 , pp. 205-207
    • Schad, L.R.1    Bock, M.2    Müller, E.3    Lorenz, W.J.4
  • 7
    • 0033005698 scopus 로고    scopus 로고
    • Submillimeter functional localization in human striate cortex using BOLD contrast at 4 tesla: implications for the vascular point spread function
    • Menon R.S., Goodyear B.G. Submillimeter functional localization in human striate cortex using BOLD contrast at 4 tesla: implications for the vascular point spread function. Magn Reson Med 1999, 41:230-235.
    • (1999) Magn Reson Med , vol.41 , pp. 230-235
    • Menon, R.S.1    Goodyear, B.G.2
  • 8
    • 0035206358 scopus 로고    scopus 로고
    • Brief visual stimulation allows mapping of ocular dominance in visual cortex using fMRI
    • Goodyear B.G., Menon R.S. Brief visual stimulation allows mapping of ocular dominance in visual cortex using fMRI. Hum Brain Mapp 2001, 14:210-217.
    • (2001) Hum Brain Mapp , vol.14 , pp. 210-217
    • Goodyear, B.G.1    Menon, R.S.2
  • 9
    • 0035950239 scopus 로고    scopus 로고
    • Human ocular dominance columns as revealed in high-field functional magnetic resonance imaging
    • Cheng K., Waggoner R.A., Tanaka K. Human ocular dominance columns as revealed in high-field functional magnetic resonance imaging. Neuron 2001, 32:359-374.
    • (2001) Neuron , vol.32 , pp. 359-374
    • Cheng, K.1    Waggoner, R.A.2    Tanaka, K.3
  • 10
    • 34548534644 scopus 로고    scopus 로고
    • Robust detection of ocular dominance columns in humans using Hahn Spin Echo BOLD functional MRI at 7 Tesla
    • Yacoub E., Shmuel A., Logothetis N., Ugurbil K. Robust detection of ocular dominance columns in humans using Hahn Spin Echo BOLD functional MRI at 7 Tesla. Neuroimage 2007, 37:1161-1177.
    • (2007) Neuroimage , vol.37 , pp. 1161-1177
    • Yacoub, E.1    Shmuel, A.2    Logothetis, N.3    Ugurbil, K.4
  • 11
    • 0028867770 scopus 로고
    • Event-related functional MR imaging of visual cortex stimulation at high temporal resolution using a standard 1.5T imager
    • Schad L.R., Wiener E., Baudendistel K.T., Müller E., Lorenz W.J. Event-related functional MR imaging of visual cortex stimulation at high temporal resolution using a standard 1.5T imager. Mag Res Imag 1995, 13:899-901.
    • (1995) Mag Res Imag , vol.13 , pp. 899-901
    • Schad, L.R.1    Wiener, E.2    Baudendistel, K.T.3    Müller, E.4    Lorenz, W.J.5
  • 12
    • 0029791198 scopus 로고    scopus 로고
    • Functional MR imaging of visual and motor cortex stimulation at high temporal resolution using a FLASH technique on a standard 1.5 Tesla scanner
    • Wiener E., Schad L.R., Baudendistel K., Essig M., Müller E., Lorenz W.J. Functional MR imaging of visual and motor cortex stimulation at high temporal resolution using a FLASH technique on a standard 1.5 Tesla scanner. Mag Res Imag 1996, 14:447-483.
    • (1996) Mag Res Imag , vol.14 , pp. 447-483
    • Wiener, E.1    Schad, L.R.2    Baudendistel, K.3    Essig, M.4    Müller, E.5    Lorenz, W.J.6
  • 13
    • 29544442876 scopus 로고    scopus 로고
    • Echo train shifted multi-echo FLASH for functional MRI of the human brain at ultra-high spatial resolution
    • Voit D., Frahm J. Echo train shifted multi-echo FLASH for functional MRI of the human brain at ultra-high spatial resolution. NMR Biomed 2005, 18:481-488.
    • (2005) NMR Biomed , vol.18 , pp. 481-488
    • Voit, D.1    Frahm, J.2
  • 14
    • 0025256879 scopus 로고
    • Echo Planar Imaging with Asymmetric Gradient Modulation and Inner-Volume Excitation
    • Feinberg D.A., Turner R., Jakab P.D., von Kienlin M. Echo Planar Imaging with Asymmetric Gradient Modulation and Inner-Volume Excitation. Magn Reson Med 1989, 13:162-169.
    • (1989) Magn Reson Med , vol.13 , pp. 162-169
    • Feinberg, D.A.1    Turner, R.2    Jakab, P.D.3    von Kienlin, M.4
  • 15
    • 0000114910 scopus 로고
    • Gradient-echo shifting in fast MRI techniques (GRASE Imaging) for correction of field inhomogeneity errors and chemical shift
    • Feinberg D.A., Oshio K. Gradient-echo shifting in fast MRI techniques (GRASE Imaging) for correction of field inhomogeneity errors and chemical shift. J Magn Reson 1992, 97:177-183.
    • (1992) J Magn Reson , vol.97 , pp. 177-183
    • Feinberg, D.A.1    Oshio, K.2
  • 17
    • 0026925939 scopus 로고
    • A Technique for Accurate Magnetic Resonance Imaging in the Presence of Field Inhomogeneities
    • Chang H., Fitzpatrick J.M. A Technique for Accurate Magnetic Resonance Imaging in the Presence of Field Inhomogeneities. IEEE Trans Med Imag 1992, 11:319-329.
    • (1992) IEEE Trans Med Imag , vol.11 , pp. 319-329
    • Chang, H.1    Fitzpatrick, J.M.2
  • 18
    • 77956614495 scopus 로고
    • Correction of Geometric Distortion in Echo Planar Images. Proceedings of the 2nd meeting of the SMR
    • Bowtell R, McIntyre DJO, Commandre M-J, Glover PM, Mansfield P. Correction of Geometric Distortion in Echo Planar Images. Proceedings of the 2nd meeting of the SMR 1994; p. 411.
    • (1994) , pp. 411
    • Bowtell, R.1    McIntyre, D.J.O.2    Commandre, M.-J.3    Glover, P.M.4    Mansfield, P.5
  • 19
    • 1842590302 scopus 로고    scopus 로고
    • Correction of Spatial Distortions in EPI due to Inhomogeneous Static Magnetic Fields Using the Reversed Gradient Method
    • Morgan P.S., Bowtell R.W., McIntyre D.J.O., Worthington B.S. Correction of Spatial Distortions in EPI due to Inhomogeneous Static Magnetic Fields Using the Reversed Gradient Method. J Magn Reson Imaging 2004, 19:499-507.
    • (2004) J Magn Reson Imaging , vol.19 , pp. 499-507
    • Morgan, P.S.1    Bowtell, R.W.2    McIntyre, D.J.O.3    Worthington, B.S.4
  • 20
    • 0142074685 scopus 로고    scopus 로고
    • How to correct susceptibility distortions in spin-echo echo-planar images: application to diffusion tensor imaging
    • Andersson J.L.R., Skare S., Ashburner J. How to correct susceptibility distortions in spin-echo echo-planar images: application to diffusion tensor imaging. Neuroimage 2003, 20:870-888.
    • (2003) Neuroimage , vol.20 , pp. 870-888
    • Andersson, J.L.R.1    Skare, S.2    Ashburner, J.3
  • 21
    • 45149145242 scopus 로고
    • A k-space analysis of small-tip-angle excitation
    • Pauly J., Nishimura D., Macovski A. A k-space analysis of small-tip-angle excitation. J Magn Reson 1989, 81:43-56.
    • (1989) J Magn Reson , vol.81 , pp. 43-56
    • Pauly, J.1    Nishimura, D.2    Macovski, A.3
  • 22
    • 77956612457 scopus 로고    scopus 로고
    • Inner volume BOLD-fMRI at ultra-high spatial resolution. Proceedings of the 17th meeting of the ISMRM
    • Heiler PM, Konstandin S, Schad LR. Inner volume BOLD-fMRI at ultra-high spatial resolution. Proceedings of the 17th meeting of the ISMRM 2009; p. 1551.
    • (2009) , pp. 1551
    • Heiler, P.M.1    Konstandin, S.2    Schad, L.R.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.